Records from 1981 to 1995. Most recent: inspection, 11 August 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 45
11 August 1995
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 884388
2 June 1995
Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 874684
16 May 1995
Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1232094
4 May 1995
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 135014
27 February 1995
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1165360
24 February 1995
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 1160003
7 February 1995
Type not recorded
No type recorded · Activities Far East · USCG Oceania District (CGD-O) · Activity 145878
29 November 1994
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 871715
16 September 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 868457
15 September 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1429963
10 June 1994
Hull Examination · Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1359686
13 January 1994
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 853867
4 January 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 665861
19 December 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 850332
25 October 1993
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 845169
27 January 1993
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1138092
1 December 1992
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1133140
27 January 1992
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1443312
22 October 1991
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1248680
1 February 1991
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 930836
27 December 1990
Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 917584
30 November 1990
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1228862
31 August 1990
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 922078
5 June 1990
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1240941
4 June 1990
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 926302
15 December 1989
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 980784
16 December 1988
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1044839
23 November 1988
Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 894567
17 December 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1312118
19 November 1987
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1308531
5 June 1987
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1027855
30 March 1987
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1020822
20 January 1987
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1315064
19 December 1986
Examination of Repairs
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1028365
4 December 1986
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1025247
4 September 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1013630
13 December 1985
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 991886
5 December 1985
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 987840
1 April 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 981984
15 January 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283935
8 September 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1282393
16 December 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 971261
16 December 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 971923
8 April 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 967066
22 December 1981
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281546
Fire Fighting
Issued 29 November 1994
Resolved
SUBMIT REVISED FIRE CONTROL/GENERAL ARRANGEMENT PLAN TO USCG MIDET SINGAPORE FOR APPROVAL.
Condition: Unknown
Due 29 November 1994
Resolved 29 November 1994
Deck/Cargo
Issued 29 November 1994
Resolved
RENEW/REPLACE BRAKE BAND LININGS FOR ALL ANCHOR WINDLASS._x001C_ _x001C_
Condition: Unknown
Due 29 November 1994
Resolved 29 November 1994
Construction/Loadline
Issued 10 June 1994
Resolved
PROVIDE NARRATED SEILOD VIDEO IN US FORMAT.
Condition: Unknown
Due 31 August 1994
Resolved 29 July 1994
Deck/Cargo
Issued 10 June 1994
Resolved
REPAIR HELO DECK SAFETY WIRE GUARD IN WAY OF CENTERLINE BOW.
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Documentation
Issued 10 June 1994
Resolved
PROVIDE COPY OF ANNOTATED SET OF PLANS SHOWING ALL INSERTS & REPAIRS COMPLETED IN ALL TANKS.
Condition: Unknown
Due 3 October 1994
Resolved 3 October 1994
Fire Fighting
Issued 10 June 1994
Resolved
SUBMIT REVISED FIRE CONTROL PLAN SHOWING THE NEW FIRE STATION #20.
Condition: Unknown
Due 31 August 1994
Resolved 16 September 1994
Construction/Loadline
Issued 19 December 1993
Resolved
MAKE AVAILABLE FOR EXAMINATION AT CREDIT HULL EXAMINATION/SEILOD THE FOLLOWING INTERNAL SPACES: 1-C, 4 P/C/S - DRILLWATER TANKS, 5 P/C/S - FUEL TANKS, 9 C - FUEL TANK, AND 9 P/S - SETL SEP TANKS.
Condition: Unknown
Due 19 December 1993
Resolved 19 December 1993
Fire Fighting
Issued 19 December 1993
Resolved
HYDROSTATICALLY TEST ALL FIXED CO2 CYLINDERS AT A DOT APPROVED FACILITY NO LATER THAN NEXT CREDIT HULL EXAMINATION.
Condition: Unknown
Due 19 December 1993
Resolved 19 December 1993
Fire Fighting
Issued 19 December 1993
Resolved
HYDROSTATICALLY TEST AND/OR REFILL ALL PORTABLE FIRE EXTINGUISHERS TO THE ATTENDING MARINE INSPECTOR'S SATISFACTION AT THE CREDIT HULL EXAMINATION. ALL HYDROSTATIC TESTING TO BE DONE AT A DOT APPROVED FACILITY.
Condition: Unknown
Due 19 December 1993
Resolved 19 December 1993
Lifesaving
Issued 19 December 1993
Resolved
MAKE PORT AND STBD LIFEBOATS AVAILABLE FOR COMPLETE STRUCTURAL INSPECTION AT HULL EXAMINATION. BOTH PORT AND STBD LIFEBOATS SHOW SIGNS OF STRESS IN FRP IN WAY OF FORE AND AFT RELEASING GEAR ATTACHMENT POINTS AND NEED FURTHER INSPECTION.
Condition: Unknown
Due 19 December 1993
Resolved 19 December 1993
Fire Fighting
Issued 19 December 1993
Resolved
ALL INTERIOR ACCOMODATION SPACE A-O STRUCTURAL FIRE PROTECTION DOORS MUST BE REPAIRED/RENEWED AND DEMONSTRATED TO THE ATTENDING MARINE INSPECTORS SATISFACTION AT NEXT HULL EXAMINATION. (REMOVE ANY HOLDBACK DEVICES, REINSTALL ANY MISSING DOOR KNOBS, LATCHES, AND AUTO-CLOSER DEVICES.)
Condition: Unknown
Due 19 December 1993
Resolved 19 December 1993
Construction/Loadline
Issued 19 December 1993
Resolved
PROVIDE A DETAILED INTERNAL HULL SURVEY REPORT FOR PRELOAD TANKS: 2, 6, 7, AND 8 (PORT & STBD) AS EXAMINED BY ABS/USCG/OWNER ON 17/18 DEC 93 AND LOCATION OF SHIPYARD SELECTED TO MAKE PERMANENT REPAIRS AND CONDUCT CREDIT HULL EXAMINATION/SEILOD.
Condition: Unknown
Due 19 December 1993
Resolved 19 December 1993
Construction/Loadline
Issued 19 December 1993
Resolved
COMPLETE ITEMS DETAILED IN ABS BOMBAY SURVEY REPORT OF 19 DEC 93 TO ATTENDING ABS SURVEYOR SATISFACTION PRIOR TO ISSUANCE OF LOADLINE CERTIFICATE AND A USCG PERMIT TO PROCEED TO A SHIPYARD/REPAIR FACILITY FOR PERMANENT HULL REPAIRS AND CREDIT HULL EXAMINATION/SEILOD.
Condition: Unknown
Due 19 December 1993
Resolved 19 December 1993
Construction/Loadline
Issued 19 December 1993
Resolved
PROVIDE/RENEW "OPEN-CLOSE" INDICATORS FOR REMOTE OPERATED VALVES LOCATED ONMAIN DECK.
Condition: Unknown
Due 19 December 1993
Resolved 19 December 1993
Lifesaving
Issued 19 December 1993
Resolved
PROVIDE DOCUMENTATION THAT ALL REQUIRED RETRO-REFLECTIVE TAPE FOR LIFEBOATSAND RING BUOYS HAS BEEN PROPERLY ATTACHED PRIOR TO DEPARTURE FOR CREDIT HULL EXAMINATION.
Condition: Unknown
Due 19 December 1993
Resolved 19 December 1993
Construction/Loadline
Issued 25 October 1993
Resolved
PROVIDE PROPOSAL IN ACCORDANCE WITH 46 CFR 107.267 FOR HULL EXAMINATION OR SEILOD.
Condition: Unknown
Due 10 November 1993
Resolved 7 December 1993
Construction/Loadline
Issued 25 October 1993
Resolved
PROVIDE DETAILED PROPOSAL/DWGS FOR MAJOR HULL REPAIRS/RENEWALS IN NO. 8P, 8S, 6P, 6S, 2P, AND 2S PRELOAD TANKS FOR [name withheld]/APPROVAL. PROPOSAL MUST INCLUDE GAUGING REPORTS, ABS SURVEY REPORTS, MATERIAL CERTS, WELDING PROCEDURES, QUALIFIED WELDERS, AND NDT TESTS.
Condition: Unknown
Due 25 October 1993
Resolved 25 October 1993
Fire Fighting
Issued 25 October 1993
Resolved
RECHARGE EACH PORTABLE AND FIXED FIRE EXTINGUISHING CYLINDER WHICH IS TEN PERCENT UNDER WEIGHT AS INDICATED IN THE FIRE SERVICE REPORT ISSUED BY THE OIM.
Condition: Unknown
Due 25 October 1993
Resolved 25 October 1993
Fire Fighting
Issued 25 October 1993
Resolved
HYDROSTATICALLY TEST EACH PORTABLE AND FIXED FIRE EXTINGUISHING CYLINDER WHICH IS DUE AS INDICATED IN THE FIRE SERVICE REPORT SUBMITTED BY THE OIM.
Condition: Unknown
Due 25 October 1993
Resolved 25 October 1993
Fire Fighting
Issued 1 December 1992
Resolved
RECHARGE CO2 BOTTLE FOR PAINT LOCKER FIXED FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 1 December 1992
Resolved 1 December 1992
Lifesaving
Issued 22 October 1991
Resolved
REPAIR OR REPLACE H2S SENSORS IN MUD PITS AND ON B.O.P. DECK.
Condition: Unknown
Due 22 October 1991
Resolved 22 October 1991
Lifesaving
Issued 22 October 1991
Resolved
PROVIDE COPY OF LIFERAFT SERVICING CERTIFICATE FOR TWO 20 PERSON DAVIT LAUNCHED LIFERAFTS CURRENTLY BEING SERVICED. MAINTAIN ON BOARD ONE 25 PERSON DAVIT LAUNCHED LIFERAFT UNTIL ORIGINAL LIFERAFTS ARE REINSTALLED.
Condition: Unknown
Due 22 October 1991
Resolved 22 October 1991
Documentation
Issued 22 October 1991
Resolved
REVISE OPERATING MANUAL IN ACCORDANCE WITH 46 CFR 109.121 AND SUBMIT FOR COAST GUARD APPROVAL OR PROVIDE COPY OF MOST RECENT APPROVAL AND STABILITY LETTERS.
Condition: Unknown
Due 22 October 1991
Resolved 22 October 1991
Lifesaving
Issued 22 October 1991
Resolved
REPLACE MISSING AIR SYSTEM BOTTLE IN #2 LIFEBOAT.
Condition: Unknown
Due 26 November 1991
Resolved 26 November 1991
Documentation
Issued 22 October 1991
Resolved
PROVIDE COPY OF DIVER'S REPORT AND VIDEO TAPE FOR UNDER WATER SURVEY COMPLETED 22OCT91.
Condition: Unknown
Due 26 November 1991
Resolved 26 November 1991
Fire Fighting
Issued 22 October 1991
Resolved
REPAIR OR REPLACE FIRE NOZZELS AT FIRE STATIONS 1,2,4,11,17 AND 18
Condition: Unknown
Due 26 November 1991
Resolved 26 November 1991
Fire Fighting
Issued 22 October 1991
Resolved
REPAIR OR REPLACE SELF CONTAINED BREATHING APPARATUS REGULATOR PRESSURE GAUGES WHICH ARE IN EMERGENCY GEAR LOCKERS.
Condition: Unknown
Due 26 November 1991
Resolved 26 November 1991
Fire Fighting
Issued 22 October 1991
Resolved
REPLACE FIRE HOSE AT FIRE STATIONS 6,18 AND 19
Condition: Unknown
Due 22 October 1991
Resolved 22 October 1991
Lifesaving
Issued 22 October 1991
Resolved
END FOR END ALL DAVIT LAUNCHED LIFERAFT FALLS AND PROVIDE [name withheld].
Condition: Unknown
Due 22 October 1991
Resolved 22 October 1991
Lifesaving
Issued 22 October 1991
Resolved
REPLACE MISSING RING BUOY SMOKE FLOAT ON STARBOARD SIDE.
Condition: Unknown
Due 22 October 1991
Resolved 22 October 1991
Fire Fighting
Issued 22 October 1991
Resolved
RENEW TIME DELAY UNIT ON MACHINERY SPACE FIXED CO2 EXTINGUISHING SYSTEM.
Condition: Unknown
Due 22 October 1991
Resolved 22 October 1991
Fire Fighting
Issued 22 October 1991
Resolved
REPLACE MISSING 100 POUND CO2 BOTTLE IN MACHINERY SPACE FIXED EXTINGUISHINGSYSTEM.
Condition: Unknown
Due 22 October 1991
Resolved 22 October 1991
Lifesaving
Issued 30 November 1990
Resolved
Provide a smoke signal approved under 46 CFR 160.057 that self-activates when ring life buoy is released from its mounting rack.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Lifesaving
Issued 30 November 1990
Resolved
Make permanent repairs to the starboard motor lifeboat's engine. Until repairs are effected, a standby vessel must be in attendance.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Lifesaving
Issued 30 November 1990
Resolved
Replace two outdated distress floating orange smoke signals in the starboard motor lifeboat.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Lifesaving
Issued 30 November 1990
Resolved
Starboard lifeboat is to be operated for 25 minutes underway after completion of permanent repairs to its main engine.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Lifesaving
Issued 30 November 1990
Resolved
Replace 174 quarts of outdated drinking water in the port motor life boat.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Lifesaving
Issued 30 November 1990
Resolved
Provide a missing Coast Guard approved hatchet in the starboard motor life boat.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Lifesaving
Issued 30 November 1990
Resolved
Provide 58 pounds of condensed milk in each motor lifeboat.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Lifesaving
Issued 30 November 1990
Resolved
Provide a fishing kit in the starboard motor lifeboat.
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990
Lifesaving
Issued 15 December 1989
Resolved
SERVICE AND REINSTALL THE TWO DAVIT LAUNCHED LIFERAFTS NOW REMOVED FROM RIG. UNTIL THIS IS COMPLETED, A STANDBY VESSEL MUST BE IN ATTENDANCE AT ALL TIMES.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Lifesaving
Issued 15 December 1989
Resolved
IN PORT AND STBD LIFEBOAT, HYDROSTATICALLY TEST ALL AIR BOTTLES (3 PER BOAT). REMOVE NO MORE THAN ONE BOTTLE AT A TIME FROM THE LIFEBOAT. BOTTLES MUST BE TESTED AT AN APPROVED FACILITY.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Lifesaving
Issued 15 December 1989
Resolved
REWIRE THE LIFERAFT EMBARKATION LIGHTS SO THAT THEY ARE POWERED BY AN EMERGENCY SOURCE. UNTIL THIS ITEM IS COMPLETED, PROVIDE PORTABLE EMERGENCY LIGHTING.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Lifesaving
Issued 15 December 1989
Resolved
RENEW 2 ORANGE SMOKE SIGNALS IN STBD LIFEBOAT.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Lifesaving
Issued 15 December 1989
Resolved
IN PORT LIFEBOAT, REPLACE FLASHLIGHT WITH C.G. APPROVED 3-CELL TYPE, OR A TYPE I OR TYPE III FLASHLIGHT CONSTRUCTED AND MARKED IN ACCORDANCE WITH ASTM F1014-1086 [REF: 46 CFR 108.503/94.20-10/94.20-15(J)].
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Lifesaving
Issued 15 December 1989
Resolved
RENEW TWO BUOYANT AND TWO NON BUOYANT ROCKETS FOR LINE THROWING APPARATUS.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Accommodation/Occupational Safety
Issued 15 December 1989
Resolved
CONDUCT QUADRENNIAL INSPECTION OF PORT AND STBD CRANES IN ACCORDANCE WITH 46 CFR 107.258 & 107.260.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Lifesaving
Issued 15 December 1989
Resolved
FOR RING BUOY STATION PORT SIDE, REPLACE MISSING SMOKE SIGNAL AND REPAIR/ REPLACE WATERLIGHT.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Fire Fighting
Issued 15 December 1989
Resolved
SERVICE ALL FIXED, SEMI-PORTABLE AND PORTABLE FIRE EXTINGUISHERS, IN ACCORDANCE WITH 46 CFR 107.235. PROVIDE COPY OF SERVICING REPORT TO [name withheld], HI.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Accommodation/Occupational Safety
Issued 15 December 1989
Resolved
PROVIDE TO [name withheld] A COPY OF THE APPROVED PLANS FOR THE HELOCOPTER FUELING SYSTEM AND MODIFICATIONS TO THE FIRE PROTECTION AND DETECTION SYSTEM REQUIRED BY THESE MODIFICATIONS. HELO DECK FUELING SYSTEM MAY NOT BE USED UNTIL PLANS FOR MODIFICATIONS ARE APPROVED.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Fire Fighting
Issued 15 December 1989
Resolved
PRIOR TO USE OF HELICOPTER DECK FUELING SYSTEM, OR STORAGE OF HELICOPTER FUEL ON BOARD, INSTALL FIRE PROTECTION SYSTEMS IN ACCORDANCE WITH 46 CFR 108.487 & 108.489 & TABLE 108.495(A). INSTALLED EQUIPMENT MUST BE IN ACCORDANCE WITH C.G. APPROVED PLANS.
Condition: Unknown
Due 15 December 1989
Resolved 15 December 1989
Engineering
Issued 23 November 1988
Resolved
REPLACE DEFECTIVE RELIEF VALVE FOR THE DRILL FLOOR LARGE AIR RECEIVER PRIOR TO USE.
Condition: Unknown
Due 23 November 1988
Resolved 23 November 1988
Construction/Loadline
Issued 23 November 1988
Resolved
IF VISIBLE DAMAGE TO SPUD CANS FOUND UPON LIFTING BY HEAVY LIFT SHIP, HAVE SPUD CANS CERTIFIED SAFE FOR WORKERS BY A MARINE CHEMIST.
Condition: Unknown
Due 23 November 1988
Resolved 23 November 1988
Construction/Loadline
Issued 23 November 1988
Resolved
PRIOR TO PLACING RIG ON LOCATION, CONDUCT NDT TESTING OF CAN TO LEG CONNECTIONS AND EXTERIOR VISUAL EXAMINATION OF HULL.
Condition: Unknown
Due 23 November 1988
Resolved 23 November 1988
Documentation
Issued 23 November 1988
Resolved
REVISE THE FIRE SAFETY AND CONTROL PLAN TO REFLECT NEW INSTALLATIONS AND SUBMIT FOR COAST GUARD APPROVAL.
Condition: Unknown
Due 23 November 1988
Resolved 23 November 1988
Lifesaving
Issued 23 November 1988
Resolved
CONDUCT FIRE AND BOAT DRILLS UPON REMANNING OF VESSEL.
Condition: Unknown
Due 23 November 1988
Resolved 23 November 1988
Electrical
Issued 19 November 1987
Resolved
CONDUCT TEST OF LOW LUBE OIL PRESSURE ALARM/SHUTDOWN FOR GENERATORS #1,2 AND 3 PRIME MOVERS.
Condition: Unknown
Due 19 November 1987
Resolved 19 November 1987
Fire Fighting
Issued 19 November 1987
Resolved
REPAIR OR REPLACE LEAKING FLANGE ON FIREPUMP DISCHARGE LOCATED IN MUD PUMP ROOM.
Condition: Unknown
Due 19 November 1987
Resolved 19 November 1987
Lifesaving
Issued 19 November 1987
Resolved
REPAIR OR REPLACE BATTLE LANTERN IN #2 LIFEBOAT.
Condition: Unknown
Due 19 November 1987
Resolved 19 November 1987
Accommodation/Occupational Safety
Issued 19 November 1987
Resolved
CONDUCT TEST OF VENTILATION SHUTDOWNS FROM CONTROL ROOM.
Condition: Unknown
Due 19 November 1987
Resolved 19 November 1987
Electrical
Issued 19 November 1987
Resolved
TEST REMOTE RIG SHUTDOWN LOCATED IN CONTROL ROOM
Condition: Unknown
Due 19 November 1987
Resolved 19 November 1987
Fire Fighting
Issued 19 November 1987
Resolved
REPAIR 4" HOLE IN AFT BULKHEAD OF MUD PIT ROOM PRIOR TO COMMENCING DRILLING OPERATIONS.
Condition: Unknown
Due 19 November 1987
Resolved 19 November 1987
Fire Fighting
Issued 19 November 1987
Resolved
REPAIR OR REPLACE GAUGES ON BOTH FIRE PUMPS.
Condition: Unknown
Due 19 November 1987
Resolved 19 November 1987
Electrical
Issued 19 November 1987
Resolved
LABEL ALL EMERGENCY LIGHTS ON MAIN DECK LIVING QUARTERS.
Condition: Unknown
Due 19 November 1987
Resolved 19 November 1987
Electrical
Issued 19 November 1987
Resolved
CONDUCT TEST OF AUTOMATIC BUS-TIE FOR STANDBY GENERATOR.
Condition: Unknown
Due 19 November 1987
Resolved 19 November 1987
Documentation
Issued 19 December 1986
Resolved
SUBMIT PLANS AND INSTALLATION INSTRUCTIONS FOR THE EXLOG INTRINSICALLY SAFE MONITORING EQUIPMENT LOCATED IN HAZARDOUS LOCATIONS INACCORDANCE WITH 46 CFR 110.25-1(L) AND 46 CFR 111.105-11 TO [name withheld], TEXASPRIOR TO 19JAN87.
Condition: Unknown
Due 19 December 1986
Resolved 19 December 1986
Electrical
Issued 4 December 1986
Resolved
PROVIDE EVIDENCE THE EXLOG ELECTRICAL PANEL ON THE DRILL FLOOR IS UL/FM/ ORCSA APPROVED FOR HAZARDOUS LOCATIONS; OR AIR PURGE IN ACCORDANCE WITH NFPA 496.
Condition: Unknown
Due 4 December 1986
Resolved 4 December 1986
Electrical
Issued 4 December 1986
Resolved
PROVIDE APPROVED SEALED FITTINGS FOR ELECTRICAL PANEL AND FIXTURES FOR THE LOGGING EQUIPMENT LOCATED IN HAZARDOUS LOCATIONS.
Condition: Unknown
Due 4 December 1986
Resolved 4 December 1986
Electrical
Issued 4 December 1986
Resolved
PROVIDE BOLTS WHERE MISSING IN ELECTRICAL PANEL BOXES IN HAZARDOUS LOCATIONS.
Condition: Unknown
Due 4 December 1986
Resolved 4 December 1986
Electrical
Issued 5 December 1985
Resolved
MAKE ADJUSTMENTS TO THE OVERSPEED TRIPS TO ENSURE THAT THE TESTING OF THE REVERSE POWER RELAYS WILL NOT CAUSE THE COMPLETE SHUTDOWN OF THE OTHER GENERATOR MOTORS.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Navigation
Issued 5 December 1985
Resolved
MOVE THE PORT AND STBD NAVIGATIONAL SIDE LIGHTS OUTWARD SO AS NOT TO BE OBSTRUCTED BY ADJACENT LADDER RAILINGS AND ENSURE THAT THE LIGHT SCREENS MAINTAIN PROPER ANGLES OF VISIBILITY AS PER COLREGS.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Electrical
Issued 15 January 1985
Resolved
REPLACE THE MISSING BUNK LIGHT IN THE HOSPITAL ROOM.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Documentation
Issued 15 January 1985
Resolved
PROVIDE THE CONSTRUCTION PORTFOLIO AS PER CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Fire Fighting
Issued 15 January 1985
Resolved
REPLACE THE RUBBER EXPANSION JOINT ON THE DEEP WELL PUMP.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Construction/Loadline
Issued 15 January 1985
Resolved
REPLACE THE BROKEN DOGS ON ALL THE VENT COVERS AS NECESSARY.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Unknown
Issued 15 January 1985
Resolved
MODIFY THE FUEL OIL HEADER SO THAT THE FUEL OIL HOSE CONNECTION IS OVER THEDRIP PAN.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Construction/Loadline
Issued 16 December 1983
Resolved
CONDUCT UNDERWATER PORTION OF "SPECIAL EXAM IN LIEU OF DRYDOCKING"
Condition: Unknown
Due 16 December 1983
Resolved 16 December 1983