MAURY USCG vessel records Sign in
← All vessels

RICKEY P CAVALIER

RICKEY P CAVALIER is a 1981 offshore supply vessel. The Coast Guard has recorded 54 inspections since 1981, most recently in June 2017, along with 29 deficiencies and 2 casualty investigations between 2009 and 2010.

Records from 1981 to 2017. Most recent: inspection, 12 June 2017.

Built
1981
Last inspected
12 June 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8926614 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDC4482
Flag
UNITED STATES
367025470 (licence lapsed)
Maury page id
psix-53118

Inspections, by type

…with no type recorded11
Years with a record 30 calendar years (1981–2017)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it265 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
79 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC4482MMSI 367025470 · expired · compulsorily equipped · granted 6 January 2015, cancelled 17 May 2025
WBB9223MMSI not assigned · expired · voluntarily equipped · granted 15 August 1996, cancelled 30 December 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 54

12 June 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6173301
26 March 2014 Cargo Tank Internal · Administrative Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4822827
23 July 2012 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4388095
1 January 2010 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3670775
26 March 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3454471
4 March 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3427381
6 February 2009 Re-Inspection · Examination of Repairs · Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3413253
29 January 2009 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3402212
28 January 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3401929
28 January 2009 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3401952
3 June 2008 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3210908
5 December 2007 Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3111282
26 March 2007 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2895572
16 March 2006 Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2582347
14 March 2005 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2307977
14 October 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2221065
29 March 2004 Internal Structural Exam · Cargo Tank Internal · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2002823
14 March 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1757208
4 March 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1493761
3 July 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073044
1 May 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064836
30 January 2001 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1382112
3 November 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803620
10 May 1998 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 791985
9 May 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 139211
4 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783676
10 September 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1371977
16 October 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442477
18 July 1996 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468392
8 November 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 884165
22 September 1995 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1398380
20 October 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449726
29 July 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 861867
12 July 1994 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 865849
12 July 1994 Initial Construction-Excluding Oversight · Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1176287
8 December 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 484311
27 September 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449638
5 May 1993 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1440693
28 October 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408923
24 September 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 938615
25 September 1991 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 934210
27 September 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1241528
20 September 1989 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1326939
23 September 1988 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043795
1 November 1987 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1327399
18 September 1987 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010219
19 March 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016169
22 December 1986 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1028686
25 September 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318901
14 May 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1302378
29 September 1985 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1001518
6 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974705
27 October 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 966077
21 July 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964200

Deficiency record · 29

Construction/Loadline › Hull › Hull Plating
Issued 29 January 2009 Resolved
After collision, vessel is directed to proceed to Superior Shipyard in Morgan City to affect permanent repairs to the port and starboard bow and the #1 portside wing fuel tank.
Action required: 705 - Other - as specified
Resolved 6 February 2009
Communications › Radio Communications › VHF Radiotelephone
Issued 3 June 2008 Resolved
Medium frequency was not in operation.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 June 2008
Resolved 5 June 2008
Resolution: Replaced antenna coupler, tunning properly, radio check with vessel in cameron. La. loud and clear
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 3 June 2008 Resolved
Rudder angle indicator was not working.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 5 June 2008
Resolved 5 June 2008
Resolution: loose connections in engine room, fixed all connections and verified rudders angle indicator''s movement from pilot house.
Construction/Loadline › Hull › Side Shell
Issued 3 June 2008 Resolved
Pinhole leak in the Sterns STBD quarter plating, about 6 inches above the waterline.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 5 July 2008
Resolved 5 June 2008
Resolution: Gouged out and repaired using the proper welding techniques.
Documentation › Certificates/Documents
Issued 29 March 2004 Resolved
The Load Line has not been endorsed since the date of issue in 2001, have ABS conduct annual survey and endorse the document. LEGACY COMPONENT DESC: Coastwise Load Line Certificate
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2004
Resolved 29 March 2004
Stability › Watertight Integrity
Issued 29 March 2004 Resolved
Adjust all watertight doors and replace the gaskets on the 01 deck aft cabin door and the engine room escape hatch. In addition make repairs to the 01 deck aft cabin watertight door the bottom of the door is rotted out. LEGACY COMPONENT DESC: Watertight Doors
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2004
Resolved 29 March 2004
Lifesaving › Buoyant Apparatus
Issued 29 March 2004 Resolved
Stencil life floats with the vessel name and the capacity. Attach the weak link to the vessel with a shackle as opposed to a piece of line. Properly attach the water lights. LEGACY COMPONENT DESC: Life Floats
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2004
Resolved 29 March 2004
Lifesaving
Issued 29 March 2004 Resolved
Provide a rescue platform for the vessel. LEGACY COMPONENT DESC: Rescue Platform
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 3 May 2004
Deck/Cargo › Vapor Control Systems
Issued 29 March 2004 Resolved
Replace flame screens in (9) vents on the main deck. LEGACY COMPONENT DESC: Flame Screens
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2004
Resolved 29 March 2004
Engineering › Diesel Engine (auxiliary)
Issued 29 March 2004 Resolved
Repair the fuel leak on the STBD generator fuel manifold. LEGACY COMPONENT DESC: Fuel Manifold
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2004
Resolved 29 March 2004
Engineering › Diesel Engine (auxiliary)
Issued 29 March 2004 Resolved
Adjust the over speed trips on both generator engines. LEGACY COMPONENT DESC: Over speed Device
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2004
Resolved 29 March 2004
Electrical › Electrical Distribution System (service)
Issued 29 March 2004 Resolved
The main switchboard was held in place with rope, properly mount the main switchboard to the vessel. LEGACY COMPONENT DESC: Switchboard
Action required: 17 - Rectify deficiencies prior to departure
Due 29 April 2004
Resolved 29 March 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 29 March 2004 Resolved
Conduct annual hydrostatic test of all transfer hoses. LEGACY COMPONENT DESC: Transfer Hose
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 April 2004
Resolved 3 May 2004
Fire Fighting › Grease Extraction Hood
Issued 29 March 2004 Resolved
Provide a filter screen and a light cover for the range hood. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 3 May 2004
Electrical › Electrical Distribution System (service)
Issued 29 March 2004 Resolved
Repair or replace the Hertz meter for the #2 generator. LEGACY COMPONENT DESC: Switchboard
Action required: 705 - Other - as specified
Due 29 April 2004
Resolved 29 March 2004
Construction/Loadline › Hull › Hull Plating
Issued 9 February 2004 Resolved
Crop and renew shell plating as necessary
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 March 2004
Resolution: Shell plating repaired IAW NVIC 7-68.
Lifesaving › Buoyant Apparatus
Issued 14 March 2003 Resolved
Lifefloats not prpoerly stowed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2003
Resolution: Showed owner and master how toproperly stowe life floats in float free configuration to ensure proper deployment.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 March 2002 Resolved
Add 2 "E" lights in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2002
Resolution: E lights installed
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 4 March 2002 Resolved
Cover loose, parts adrift.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2002
Resolution: COrrected by electrician.
Stability › Watertight Integrity
Issued 4 March 2002 Resolved
Provide dogging wrenches for all doors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2002
Resolution: Wrenches provided
Stability › Watertight Integrity
Issued 4 March 2002 Resolved
Stensil all water tight doors.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2002
Resolution: Dors stensiled.
Navigation
Issued 22 September 1995 Resolved
REPLACE TWO HYD LINES INWAY OF LAZERETTE TO STEERING GEAR SYSTEM RAMS.
Condition: Unknown
Due 22 September 1995
Resolved 31 January 1996
Construction/Loadline
Issued 22 September 1995 Resolved
REPAIR FRACTURES TO BTM SHELL STIFFNERS AT WELD TO BTM LONGS INWAY OF LAZARETTE.
Condition: Unknown
Due 22 September 1995
Resolved 31 January 1996
Lifesaving
Issued 22 September 1995 Resolved
RENEW UPPER BECKET LINES TO UPPER LIFE FLOAT.
Condition: Unknown
Due 22 September 1995
Resolved 31 January 1996
Accommodation/Occupational Safety
Issued 22 September 1995 Resolved
RENEW A ORIGINAL VENT RISER TO MSD TANK INWAY OF COMPANION WAY.
Condition: Unknown
Due 22 September 1995
Resolved 31 January 1996
Navigation
Issued 22 September 1995 Resolved
TAKE UP SLACK AS NEEDED TO STEERING SYSTEM CHAIN DRIVE VERTICIAL RUNS INWAYOF COMPANION WAY LADDER.
Condition: Unknown
Due 22 September 1995
Resolved 31 January 1996
Construction/Loadline
Issued 22 September 1995 Resolved
REMOVE OILY WATER FROM MACHINERY SPACE & COMPANION WAY BILGES.
Condition: Unknown
Due 22 September 1995
Resolved 31 January 1996
Construction/Loadline
Issued 22 September 1995 Resolved
CROP AND RENEW BILGE PUMP DISCHARGE LINE AT TEE OUTLET WHERE TEMPORARLY PATCHED.
Condition: Unknown
Due 22 September 1995
Resolved 31 January 1996
Fire Fighting
Issued 22 September 1995 Resolved
CROP AND RENEW CROSS-OVER DISCHARGE LINE BETWEEN BILGE AND FIRE PUMP WHERE TEMPORARLY PATCHED.
Condition: Unknown
Due 22 September 1995
Resolved 31 January 1996

Casualty record · 2

28 January 2009Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 3401952
1 January 2010Routine · role: Involved in a Marine Casualty · activity 3670775
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.