MUTTY'S PRIDE

MUTTY'S PRIDE is a 1979 offshore supply vessel. The Coast Guard has recorded 73 inspections since 1981, most recently in December 2011, along with 59 deficiencies — 11 with no resolution recorded —, 5 operational controls and 1 casualty investigation in 2003.

Records from 1981 to 2011. Most recent: inspection, 17 December 2011.

Built
1979
Last inspected
17 December 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7917757 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
SAINT KITTS AND NEVIS
366889960 (licence lapsed)
Maury page id
psix-53121

Inspections, by type

…with no type recorded23
Years with a record 26 calendar years (1981–2011)
The 73 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it197 - Regulatory (Subpart C or D), Net Ton
195 - Convention (Subpart B), Net Ton
290 - Regulatory (Subpart C or D), Gross Ton
651 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB3666MMSI 366889960 · cancelled · compulsorily equipped · granted 17 April 2003, cancelled 6 February 2013 · licensed under a name not among this hull’s recorded names (not shown)
WUV4172MMSI not assigned · expired · compulsorily equipped · granted 22 March 1994, cancelled 8 August 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 4

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

R-306 Passenger (Inspected) · MISLE 53807 · 26 July 2000 · activity 22069PETER STEPHAICH Towing Vessel · MISLE 213622 · 15 June 1996 · activity 23891S 2022 Tank Barge · MISLE 53003 · 22 February 1992 · activity 85700EMILEE ALEXIS Towing Vessel · MISLE 99180 · 22 February 1992 · activity 85700

Inspection history · 73

17 December 2011 CCSSC Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4210602
22 September 2011 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4151377
26 August 2011 CCSSC Examination · ISPS II Exam · PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4089121
28 January 2011 CCSSC Examination · ISPS II Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3934183
4 November 2010 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3885086
22 October 2010 CCSSC Examination · ISPS III Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3873575
20 October 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3873792
5 October 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3863817
24 September 2010 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3855137
8 August 2008 PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3292630
5 May 2008 PII Safety Exam · ISPS II Exam · ILO-147 Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3200034
7 February 2008 ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3143290
16 January 2008 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3131557
14 December 2007 MARPOL Annex I Examination · ISPS I Exam · Ballast Water Examination · MARPOL Annex V Examination · PI Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3115451
13 December 2007 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3115009
20 November 2007 ISPS I Exam · PI Safety Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3102171
11 March 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2022558
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1970901
14 May 2003 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1793321
23 February 2003 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1756833
13 February 2002 Cargo Tank Internal · Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1486351
24 May 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1063604
22 February 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1061445
2 October 2000 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 451270
26 July 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 22069
17 April 2000 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1450446
13 September 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 784929
20 June 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1082070
4 June 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803420
20 May 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 802582
15 April 1999 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418498
6 March 1999 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 68362
24 February 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1123897
29 December 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 808760
23 June 1998 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1127421
6 January 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1123463
4 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783792
20 November 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 770767
23 October 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 209910
14 March 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1092453
24 February 1997 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409653
16 July 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 765027
12 July 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 193481
28 June 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1086346
15 June 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 23891
15 June 1996 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 884779
17 April 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 764744
11 March 1996 Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465856
5 March 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 193486
12 February 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1371277
14 February 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448618
18 February 1994 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467858
20 September 1993 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 654609
19 September 1993 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 118196
13 January 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466301
2 April 1992 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1258082
22 February 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 85700
14 January 1992 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 949952
12 August 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1249349
18 September 1990 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 908685
16 November 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1236188
25 August 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1031908
10 August 1989 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 889918
21 February 1989 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1208436
19 January 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 888678
13 April 1988 Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 990516
26 February 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1333748
31 December 1987 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315495
31 December 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1329649
5 November 1986 Re-Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1327948
19 December 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 994703
22 August 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283532
28 December 1981 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 967908

Deficiency record · 59

Operations/Management › Pollution › Control of Garbage
Issued 17 December 2011 No resolution recorded
Noted that the [name withheld] indicated the vessel was not aware the Caribbean Sea was now listed as a "Special Area". In addition noted missing entries. Performed training this date w/ crew as ship's company is a small entity. Specially that all garbage streams are to be accounted for. 33 CFR 151.55, 33 CFR151.71
Action required: 15 - Rectify deficiencies by next port
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 17 December 2011 No resolution recorded
Noted that Port Sludge Tank is 3/4 full at 772 gallons. Vessel is to discharge contents and provide a reciept prior to returing to the U. S. In addition noted missing entries thoughout ORR for tank contents. Training conducted this exam, recommend penalty action for any further violations. 33 CFR 151.25
Action required: 15 - Rectify deficiencies by next port
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 17 December 2011 No resolution recorded
Noted that new MSM Document required a [name withheld] Old doc's required a 2nd Eng. Prior to entering next U.S. Port, verify that ship is manned IAW MSM document. CCSSC Chap. 1.7
Action required: 15 - Rectify deficiencies by next port
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 17 December 2011 No resolution recorded
Noted numerous documents expiring shortly after vsl's departure. Vessel to provide evidence that all documents are updated as necessary prior to next U.S. Port Call.
Action required: 15 - Rectify deficiencies by next port
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 December 2011 No resolution recorded
Repair light and fan for galley exhaust hood. Noted wiring to be covered in grease and a open light circuit. CCSSC Chap.2.27
Action required: 15 - Rectify deficiencies by next port
Communications › Visual Communication › Signalling Lamp
Issued 17 December 2011 No resolution recorded
Provide bulb for signal lamp. CCSSC Chap. 6.3
Action required: 15 - Rectify deficiencies by next port
Construction/Loadline › Structures › Door
Issued 17 December 2011 No resolution recorded
Repair rear housing hatch WTD, noted to have a wasted coaming on the knife edge. Provide FULL gaskets for all other WT closures on the cargo deck. ICLL & CCSSC Chap. 2.4
Action required: 15 - Rectify deficiencies by next port
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 17 December 2011 No resolution recorded
Replace broken starboard bridge window. CCSSC Chap. 2.2.8
Action required: 15 - Rectify deficiencies by next port
Communications › Audible Communications › Horn/Whistle
Issued 17 December 2011 No resolution recorded
Noted ship's whistle to be weak and not in compliance with COLREGs Annex III.
Action required: 15 - Rectify deficiencies by next port
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 17 December 2011 No resolution recorded
Noted that NOA had numerous incorrect entries for ship's crew members (i.e. No Master or Chief Engineer listed). Highly recommend screening vsl in the future and administer penalties for future violations or denying entry into port.
Action required: 15 - Rectify deficiencies by next port
Deck/Cargo › Cargo Stowage › General
Issued 17 December 2011 No resolution recorded
Noted vessel stored cargo blocking ability to close engine room ventilation down. Corrected on scene. Recommend stronger actions for future violations of such severe safety considerations.
Action required: 15 - Rectify deficiencies by next port
Lifesaving › Lifejacket/PFD (General) › Size
Issued 26 August 2011 Resolved
0660- Lifesaving appliances required by Chap 4 of the Caribbean Cargo Code should comply with the technical specifications of the LSA code. Vessel has 01 children on board and does not have a child's lifejacket. CSCCS CHAP 4.3, LSA CODE CHAP 2.2 CODE 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 August 2011
Resolution: Vessel purchased childs lifejacket.
Navigation › Piloting/Steering › US Coast Pilot
Issued 26 August 2011 Resolved
1570- Ships should comply with the following requirements (REG 21-30). SOLAS CHAP V REG 27 STATES NAUTICAL CHARTS AND PUBLICATIONS NESSACARY FOR INTENDED VOYAGE SHALL BE ADEQUATE AND UP TO DATE. VESSELS COAST PILOT, LIGHT LIST, AND TIDE TABLES WERE NOT UP TO DATE. CSCCS CHAP 6, SOLAS 74(2009 CONS) CHAP V REG 27. CODE 16c
Action required: 705 - Other - as specified
Due 9 September 2011
Resolved 23 September 2011
Resolution: Vessel provided current editions of required publications.
Lifesaving › Launching Appliances › Davit
Issued 26 August 2011 Resolved
0635- RESCUE BOATS SHOULD BE STOWED IN A STATE OF CONTINUOUS READINESS FOR LAUNCHING IN NOT MORE THAN 5 MINUTES. LAUNCHING APPLIANCE IS INOPERABLE DUE TO FAULTY ELECTRIC MOTOR. CSCCS CHAP 4.9.8 CODE 17c
Action required: 17 - Rectify deficiencies prior to departure
Due 26 August 2011
Resolved 26 August 2011
Resolution: Engineer repaired motor and demonstrated operation
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 28 January 2011 Resolved
Do not have suction hose for the emergancy fire pump. As is it cannot draw suction from the sea.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 28 January 2011
Resolved 28 January 2011
Resolution: Vessel Master obtained a suction hose, USCG inspector [name withheld] witnessed fire pump working.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 28 January 2011 Resolved
The fixed fire detection system is not working.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 February 2011
Resolved 11 February 2011
Resolution: USCG witness
Engineering › Generator (propulsion-electric) › Winding
Issued 28 January 2011 Resolved
Insulation wetted through with oil on #2 generator exhaust manifold
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2011
Resolved 11 February 2011
Resolution: USCG witness
Engineering › Generator (propulsion-electric) › Receptacle
Issued 28 January 2011 Resolved
#1 generator fix jacket water expansion tank is continously overflowing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 February 2011
Resolved 11 February 2011
Resolution: USCG witness
Stability › Water on Deck › General
Issued 28 January 2011 Resolved
Remove all of the water located in the vestbule between ballast water tanks and find location of leak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 February 2011
Resolved 26 August 2011
Electrical › Electric Generation Source (service) › Switch
Issued 28 January 2011 Resolved
Engine room charging system inoperative. Class report required.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 August 2011
Electrical › Electrical Distribution System (emergency) › Switch
Issued 28 January 2011 Resolved
Emergency battery charging system suspect of not operating. Class report required.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 August 2011
Construction/Loadline › Structures › Machinery Space Opening
Issued 22 October 2010 Resolved
1280 Portside forward machinery space closure ruined and incapable of closure. Make permanent repairs prior to 22NOV2010. 50c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 November 2010
Resolved 12 November 2010
Resolution: repairs completed
Fire Fighting › Self-contained Breathing Apparatus › Air Supply (minutes)
Issued 22 October 2010 Resolved
0735 SCBA Bottles low pressure. Fill both SCBA bottles prior to 29OCT2010. 40c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 October 2010
Resolved 12 November 2010
Resolution: completed and refill SCBA bottles
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 8 August 2008 Resolved
Vessel does not have a duly qualified Chief Engineer on board as required by the flag-issued Safe Manning Certificate.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2008
Resolution: A qualified Chief Engineer was added to the crew, providing all proper documentation necessary to meet the Safe Manning requirements.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 8 August 2008 Resolved
Chief Mate does not have valid endorsement for license from the vessels Flag State.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2008
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 8 August 2008 Resolved
Crewmember serving as Chief Engineer did not have a valid mariner's license. Port State Control Officers were presented with an expired Flag endorsement for a Chief Engineer who was not currently employed on board the vessel.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2008
Resolution: A qualified Chief Engineer was added to the crew, providing all proper documentation necessary to meet the Safe Manning requirements.
Engineering › Steering Gear System › Power Unit
Issued 7 February 2008 Resolved
While conducting Emergency Steering test the control panel blew a fuse and the steering gear was non operational. Cite: CCSSCODE Ch. 2 2.33.2
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 7 February 2008
Resolved 7 February 2008
Resolution: Fuse had to be replaced by a local electrician and was repaired prior to departure. Steering gear was confirmed operational by [name withheld].
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 7 February 2008 Resolved
Emergency Fire Pump was not working properly. System would not produce jet stream of water. Cite: CCSSCODE Ch. 3 3.3.1.1
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 7 February 2008
Resolved 7 February 2008
Resolution: Crew was able to get Emergency Fire Pump working before examination was complete. Suction hoses were not attached properly.
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 14 December 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 22 December 2007
Resolution: cleared
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 14 December 2007 Resolved
Master, Chief engineer (US licensed Officer) and designated Chief Mate (Panamanian 2nd Officer) do not posses valid flag Administration endorsements. Vessel is required to provide proof of compliance with STCW requirements to the satisfaction of the administration and the USCG prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 December 2007
Resolution: cleared
Documentation › Certificates/Documents › Document of Compliance (ISM)
Issued 14 December 2007 Resolved
Vessel does not posses valid SMC and copy of a valid DOC onboard. Request Administration to issue a valid ISM certificates to be placed onboard and provide proof of documentation to the USCG prior to departure
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2007
Resolution: Recieved copies of interim DOC/SMC issued by administration.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 14 December 2007 Resolved
Vessel does not posses a valid COFR. Provide proof of documentation to the USCG prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 December 2007
Resolution: Received email from the COFR desk confirming that the subject vessel was found in substantial compliance with COFR regulations.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 20 November 2007 Resolved
CCSSC was issued to the vessel on 14NOV2007 by IROS. Form of Record of Equipment is not attached to CCSSC.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2007
Resolution: IROS Surveyor faxed document to vessel.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 20 November 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2007
Resolution: Flag State (St. Kitts & Nevis) issued a letter to vessel reporting that the crew on board is acceptable to sail as Ch. Mate & CH Engineer for a single voyage, from Larose, LA to Anguila VIA SAN JUAN PR.
Lifesaving › Launching Appliances › Winch
Issued 20 November 2007 Resolved
Rescue boat launching davit & winch are original construction (prior US Flag, non-SOLAS) & do not meet the requirements of SOLAS LSA Code, as referred to by CCSS Code.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 December 2007
Resolution: Flag State (St. Kitts) issued Letter of Dispensation exempting this vsl from the requirements of LSA. Additional rescue platform, stokes litter, safety harness & small boat were required on board for one single voyage from LA to Anguila via San Juan, PR.
Engineering › Diesel Engine (propulsion-electric)
Issued 14 May 2003 Resolved
Engine gages on starboard engine not operating at operating station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2003
Resolution: Gages fixed by electrical 3rd-party.
Fire Fighting › Fire Hoses
Issued 14 May 2003 Resolved
Nozzle missing chain.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2003
Resolution: Chain installed after procurement.
Lifesaving › Rescue Boat Equipment
Issued 14 May 2003 Resolved
Missing harness.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2003
Resolution: Harness procured.
Electrical
Issued 22 February 2001 Resolved
DEMONSTRATE PROPER OPERATION OF ENGINE ROOM SOUND POWERED PHONE AUDIBLE/VISUAL INDICATOR UNDER EMERGENCY POWER TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 22 February 2001
Resolved 22 February 2001
Lifesaving
Issued 20 June 1999 Resolved
DEMONSTRATE COMPLIANCE WITH EIGHT COAST GUARD DISTRICT POLICY "RESCUE BOAT REQUIREMENTS ON OFFSHORE SUPPLY VESSELS" DATED NOVEMBER 12, 1998, TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 20 June 1999
Resolved 20 June 1999
Lifesaving
Issued 24 February 1999 Resolved
DEMONSTRATE COMPLIANCE WITH EIGHT COAST GUARD DISTRICT POLICY "RESCUE BOAT REQUIREMENTS ON OFFSHORE SUPPLY VESSELS" DATED NOVEMBER 12, 1998, TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 24 February 1999
Resolved 24 February 1999
Documentation
Issued 24 February 1999 Resolved
PROVIDE UPDATED COPY OF FIRE SAFETY PLAN REFLECTING INSTALLATION OF ENGINEROOM FIXED CO2 SYSTEM, PLAN IS TO BE DRAWN IAW 46 CFR 97.36-1 TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 24 February 1999
Resolved 24 February 1999
Deck/Cargo
Issued 6 January 1998 Resolved
MAKE PERMANENT REPAIRS TO PORT AFT DRY BULK TANK TO SATISFACTION OF THE ATTENDING MARINE INSPECTOR. TANK SHALL NOT BE USED UNTIL REPAIRS ARE AFFECTED.
Condition: Unknown
Due 6 January 1998
Resolved 6 January 1998
Engineering
Issued 12 February 1996 Resolved
PERFORM AN INTERNAL AND EXTERNAL EXAM OF THE VESSEL'S FOUR DRY BULK RECEIVERS AT THE NEXT AVAILIBLE DRYDOCKING OR CREDIT DRYDOCKING WHICHEVER OCCURES FIRST.
Condition: Unknown
Due 14 January 1997
Resolved 23 February 1996
Construction/Loadline
Issued 12 February 1996 Resolved
REPAIR THE DAMAGED STBD CORNER WRAPPER TO THE SATISFACTION OF THE ATTENDINGUSCG MARINE INSPECTOR NO LATER THAN 12MAR96.
Condition: Unknown
Due 12 February 1996
Resolved 12 February 1996
Fire Fighting
Issued 10 August 1989 Resolved
REPAIR MAIN FIRE PUMP.
Condition: Unknown
Due 10 August 1989
Resolved 10 August 1989
Engineering
Issued 10 August 1989 Resolved
SHAFT TACHOMETERS INOPERABLE.
Condition: Unknown
Due 10 August 1989
Resolved 10 August 1989
Documentation
Issued 10 August 1989 Resolved
TEST PROCEDURES FOR AUTOMATION SYSTEM OUTDATED.
Condition: Unknown
Due 10 August 1989
Resolved 10 August 1989
Engineering
Issued 21 February 1989 Resolved
OPEN, GAS FREE, AND MAKE AVAILABLE THE FOUR (4) DRY BULK TANK FOR INTERNAL EXAMINATION.
Condition: Unknown
Due 21 February 1989
Resolved 21 February 1989
Unknown
Issued 26 February 1988 Resolved
PROVE OPERATION OF MAIN ENGINE OVERSPEED TRIPS.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Unknown
Issued 26 February 1988 Resolved
PROVE OPERATION OF GENERATOR OVERSPEED TRIPS.
Condition: Unknown
Due 26 February 1988
Resolved 26 February 1988
Navigation
Issued 31 December 1987 Resolved
REPLACE EXISTING RUNNING LIGHTS WITH LIGHTS THAT COMPLY WITH CURRENT COAST GUARD REGULATIONS. COMDTINST M16672.28 AND 46 CFR 111.75-17.
Condition: Unknown
Due 31 December 1987
Resolved 31 December 1987
Engineering
Issued 31 December 1987 Resolved
REPAIR OVERSPEED TRIPS ON PORT AND STARBOARD MAIN ENGINES AND PROVE SATISFACTORY OPERATION. SEE ABS RULE 35.21.2(B).
Condition: Unknown
Due 31 December 1987
Resolved 31 December 1987
Engineering
Issued 31 December 1987 Resolved
REPAIR OVERSPEED TRIPS ON PORT AND STARBOARD GENERATOR AND PROVE SATISFACTORY OPERATION. SEE 46CFR111.12-1.
Condition: Unknown
Due 31 December 1987
Resolved 31 December 1987
Engineering
Issued 5 November 1986 Resolved
PROVIDE MANUFACTURERS DATA PLATE ON TBW DRYBULK TANKS.
Condition: Unknown
Due 5 November 1986
Resolved 5 November 1986
Navigation
Issued 19 December 1985 Resolved
MAKE PERMANENT REPAIRS TO SECOND RADAR.
Condition: Unknown
Due 19 December 1985
Resolved 19 December 1985
Documentation
Issued 19 December 1985 Resolved
PROVIDE CURRENT COAST GUARD CERTIFICATE OF DOCUMENTATION STICKER.
Condition: Unknown
Due 19 December 1985
Resolved 19 December 1985
Lifesaving
Issued 19 December 1985 Resolved
INSTALL INFLATABLE LIFERAFTS IN PERMANENT BRACKETS.
Condition: Unknown
Due 19 December 1985
Resolved 19 December 1985
Lifesaving
Issued 19 December 1985 Resolved
REPLACE WINCH ON RESCUE BOAT.
Condition: Unknown
Due 19 December 1985
Resolved 19 December 1985

Casualty record · 1

23 February 2003Routine · role: Involved in a Marine Casualty · 1 injured · activity 1756833
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

ENSCO CARRIER (2003). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.