Records from 1982 to 1993. Most recent: inspection, 8 November 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
8 November 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 848198
13 February 1992
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1257714
16 May 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1219006
4 April 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 921633
24 January 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 931241
24 January 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1234332
16 November 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 895031
26 August 1988
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 893306
21 January 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016016
13 July 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015868
10 June 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1014905
21 November 1986
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1331625
10 July 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988741
6 February 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301476
3 January 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990568
1 November 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 976697
15 May 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 974178
16 December 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1279051
8 November 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970064
Electrical
Issued 16 November 1988
Resolved
DEMONSTRATE AN OPERABLE EMERGENCY LIGHTING SYSTEM FOR LIFERAFT STATIONS.
Condition: Unknown
Due 16 November 1988
Resolved 16 November 1988
Fire Fighting
Issued 16 November 1988
Resolved
PROVIDE EVIDENCE OF FIRE/EMERGENCY DRILLS AND LINE THROWING GUN DRILL IN LAST THREE MONTHS.
Condition: Unknown
Due 16 November 1988
Resolved 16 November 1988
Fire Fighting
Issued 16 November 1988
Resolved
UPDATE AND PROVIDE A U.S.C.G. APPROVED FIRE AND SAFETY PLAN. POST PLAN ON THE VESSEL.
Condition: Unknown
Due 16 November 1988
Resolved 16 November 1988
Electrical
Issued 16 November 1988
Resolved
SHOW PROPER OPERATION OF NO. 1 GENERATOR REVERSE POWER RELAY.
Condition: Unknown
Due 16 November 1988
Resolved 16 November 1988
Lifesaving
Issued 21 November 1986
Resolved
PROVIDE FIRE CONTROL PLAN.
Condition: Unknown
Due 21 November 1986
Resolved 21 November 1986
Navigation
Issued 6 February 1986
Resolved
PROVIDE CERTIFICATE OF ALTERNATE COMPLIANCE FOR RANGE LIGHTS
Condition: Unknown
Due 6 February 1986
Resolved 6 February 1986
Engineering
Issued 1 November 1984
Resolved
PROVIDE THE VESSEL WITH THE REQUIRED SLOP OIL STANDARD DISCHARGE CONNECTION.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Engineering
Issued 1 November 1984
Resolved
BLANK OFF THE OPEN SPACES ON THE ENGINE GAUGE PANEL.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 1 November 1984
Resolved
PROVIDE A RECORD OF THE REQUIRED TESTS FOR THE FUEL OIL TRANSFER HOSES.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Engineering
Issued 1 November 1984
Resolved
REPAIR THE STARBOARD SIDE REACH ROD FOR THE FUEL OIL SHUTOFF VALVE.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Construction/Loadline
Issued 1 November 1984
Resolved
REPLACE #7 BALLAST TANK VENT FLOAT AND THE PORT SIDE POTABLE WATER TANK VENT FLOAT.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Navigation
Issued 1 November 1984
Resolved
REPAIR OR REMOVE THE FATHOMETER.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Construction/Loadline
Issued 1 November 1984
Resolved
PROPERLY PACK OR PLUG THE AFT ENGINE ROOM BULKHEAD STUFFING TUBES.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Electrical
Issued 1 November 1984
Resolved
REPAIR THE REVERSE POWER RELAY FOR GENERATOR #1.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Engineering
Issued 1 November 1984
Resolved
REPAIR OR REMOVE THE TACHOMETER FOR #2 GENERATOR.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Fire Fighting
Issued 1 November 1984
Resolved
PERMANENTLY REPAIR OR REPLACE THE FIRE/BALLAST PUMP HOUSING.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Fire Fighting
Issued 1 November 1984
Resolved
INSTALL A SEAL ON THE FIRE/BILGE PUMP.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Engineering
Issued 1 November 1984
Resolved
PROVIDE HAND RELIEVING DEVICES FOR THE SHIP SERVICE AIR RECEIVER RELIEF VALVES.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Electrical
Issued 1 November 1984
Resolved
PROVIDE A POTABLE WATER TANK PRESSURE SWITCH WITH A COVER AND PROPERLY SECURE THE WIRING.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Engineering
Issued 1 November 1984
Resolved
REPAIR OR REMOVE THE WASTED SECTION OF THE ENGINE ROOM EXHAUST ON THE STARBOARD SIDE.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Accommodation/Occupational Safety
Issued 1 November 1984
Resolved
INSTALL THE PROPER A/C DRAIN PIPING IN THE COMPANIONWAY TO THE ENGINE ROOM.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Fire Fighting
Issued 1 November 1984
Resolved
HYDROSTATICALLY TEST OR REPLACE TWO (2) ENGINE ROOM CO2 EXTINGUISHERS.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Fire Fighting
Issued 1 November 1984
Resolved
REPLACE THE FOCSLE DECK FIRE EXTINGUISHER WITH TWO (2) A-II EXTINGUISHERS.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Construction/Loadline
Issued 1 November 1984
Resolved
MAKE PERMANENT REPAIRS TO THE DAMAGED AREAS ON THE STARBOARD SIDE OF THE RUDDER COMPARTMENT.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Construction/Loadline
Issued 1 November 1984
Resolved
CLEAN ALL WATERTIGHT DOOR GASKETS AND KNIFE EDGES.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Electrical
Issued 1 November 1984
Resolved
LABEL ALL MOTOR CONTROLLERS.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Electrical
Issued 1 November 1984
Resolved
LABEL ALL BREAKERS IN THE DISTRIBUTION BOXES IN THE ENGINE ROOM.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Documentation
Issued 16 December 1983
Resolved
PROVIDE THE VESSEL WITH OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 16 December 1983
Resolved 16 December 1983
Fire Fighting
Issued 16 December 1983
Resolved
SERVICE AND TAG ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 16 December 1983
Resolved 16 December 1983
Electrical
Issued 16 December 1983
Resolved
PROVIDE BLANKS WHERE BREAKER SWITCHES ARE MISSING IN LIGHTING AND DISTRIBUTION PANALS THROUGHOUT VESSEL.
Condition: Unknown
Due 16 December 1983
Resolved 16 December 1983
Engineering
Issued 16 December 1983
Resolved
MAKE PERMANENT INSTALLATION TO THE STARBOARD MAIN ENGINE REDUCTION GEAR COOLING WATER PUMP INCLUDING WIRING.
Condition: Unknown
Due 16 December 1983
Resolved 16 December 1983
Electrical
Issued 16 December 1983
Resolved
INSTALL GLOBES AND GUARDS ON ALL LIGHT FIXTURES THAT REQUIRE THEM AND WHERETHEY ARE MISSING.
Condition: Unknown
Due 16 December 1983
Resolved 16 December 1983
Documentation
Issued 16 December 1983
Resolved
HAVE THE ANNUAL SURVEY FOR LOAD LINE CERTIFICATE ENDORSEMENT COMPLETED.
Condition: Unknown
Due 16 December 1983
Resolved 16 December 1983
Electrical
Issued 16 December 1983
Resolved
PLACE ALL BUNK LIGHTS IN OPERATIONAL CONDITION.
Condition: Unknown
Due 16 December 1983
Resolved 16 December 1983