This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
960 - Regulatory (Subpart C or D), Gross Ton
960 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-53131
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 22
10 January 1997Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354078
RENEW HATCH COVERS AND CAPTIVES CHAINS, AS NEEDED, FOR ALL STARBOARD SIDE VOIDS.
Condition: Unknown
Due 7 August 1995
Resolved 7 August 1995
Documentation
Issued 16 June 1995Resolved
PROVIDE APPROVED SOPEP FOR EXAMINATION BY THE COGNIZANT OCMI._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 September 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 14 October 1994Resolved
RENEW CAPTIVE CHAIN ON THE #1 VOID PORT SIDE MAN HOLE COVER AND MAKE AVAILABLE FOR INSPECTION PRIOR TO 14NOV94. ALL WORK TO BE COMPLETED TO THESATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Construction/Loadline
Issued 18 August 1993Resolved
MAKE WATERTIGHT, PROVIDE CAPTURE CHAINS AND PROVE PROPER OPERATION OF DOGGING DEVICES FOR ALL PORTSIDE WATERTIGHT HATCHES.
Condition: Unknown
Due 18 August 1993
Resolved 18 August 1993
Construction/Loadline
Issued 12 March 1992Resolved
PROVIDE COVERS AND GASKETS FOR MANHOLES AS REQUIRED.
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Construction/Loadline
Issued 3 December 1990Resolved
REPAIR/REPLACE SECOND AND THIRD LONGITUDINALS UP FROM THE BOTTOM, PORT SIDE, SIDE SHELL, IN THE VICINITY OF FRAMES 11, 12, AND 13. THE SIDE SHELL IS SET IN HERE.
Condition: Unknown
Due 3 December 1990
Resolved 3 December 1990
Construction/Loadline
Issued 3 December 1990Resolved
REPAIR FRAMES 2 AND 3, PORT AND STB'D, WHERE THE WEB OF THE DECK FRAME IS SET IN. AN IMPROPER INSERT AT FRAME 2 STB'D, WITH SQUARE CORNERS MUST BE REPLACED WITH A PROPER INSERT.
Condition: Unknown
Due 3 December 1990
Resolved 3 December 1990
Construction/Loadline
Issued 3 December 1990Resolved
REPAIR LONGITUDINAL CENTER BULKHEAD IN WAY OF STERNLOG WHERE SET IN. REPAIR BY INSERT.
Condition: Unknown
Due 3 December 1990
Resolved 3 December 1990
Construction/Loadline
Issued 3 December 1990Resolved
REPAIR/ REPLACE PLATING IN CENTERLINE BULKHEAD, NEAR DECK AND EXTENDING N 12" TO 18", BETWEEN FRAMES 11, 12, 13, AND 14 AS IT IS BUCKLED. REPAIR BY INSERT. ALSO REPAIR OTHER BUCKLED AREAS IN CL. BULKHEAD BETWEEN FRAMES 4 AND 23 AS DIRECTED BY CG INSPECTOR AT THE DRYDOCK INSPECTION.
Condition: Unknown
Due 3 December 1990
Resolved 3 December 1990
Construction/Loadline
Issued 1 October 1987Resolved
MAKE PERMENANT REPAIRS TO PORT SKEG PIPE SUPPORT, RENEW AS ORIGINAL.
Condition: Unknown
Due 1 October 1987
Resolved 1 October 1987