Records from 2009 to 2025. Most recent: inspection, 15 May 2025.
Documentation record
Registered dimensions (L × B × D)94.5 ft × 42.2 ft × 9.5 ft
Registered tonnagegross 99 / net 99
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFISHERMAN'S BOAT SHOP INC · EVERETT, WA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portINCHELIUM, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
99 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 12
15 May 2025
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8136684
3 April 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8131244
4 June 2024
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7936941
11 June 2023
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7710845
7 April 2022
Annual Inspection · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7421546
6 May 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7189106
17 July 2020
Internal Structural Exam · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7017441
30 April 2019
Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6686529
10 April 2019
COI Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6660084
7 May 2018
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6399879
8 April 2017
Administrative Inspection · Periodic Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6122194
16 May 2016
Annual Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5861103
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 May 2025
No resolution recorded
If divers are utilized to conduct the underwater survey as part of the examination process, Alternate Hull Examinations (AHEs) must be performed twice within every five-year period, with no more than three years allowed between any two AHEs. This required three-year interval was exceeded on May 8, 2025.
You must provide our office, Officer in Charge, Marine Inspection (OCMI), with a written hull examination report to include: thickness gauging results, bearing clearances, a copy of audio and video recordings, and any other information that will help the OCMI evaluate your vessel for a credit hull exam. This report must be signed by the third party examiner and confirm the validity of its contents.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2025 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 4 June 2024
Resolved
You must submit your written application for renewal of a Certificate of Inspection to the OCMI at least 30 days prior to the expiration date of the Certificate of Inspection. Vessel allowed their COI to lapse with no notice to OCMI.
Action required: 10 - Deficiency Rectified
Due 4 June 2024
Resolved 4 June 2024
Resolution: Completed COI.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 4 June 2024
Resolved
Any vessel of at least five net tons which engages in [...] coastwise trade (Defined as the transportation of passengers or merchandise between points embraced within the coastwise laws of the United States). Vessel had an expired Certificate of Documentation, reapplied to NVDC.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2024
Resolved 19 August 2024
Resolution: Verified via data pull COI is renewed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 June 2024
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Vessel just came due for annual servicing, scheduled for the following week. Must provide documentation showing portable extinguishers servicing. Vessel also has pre-engineered system installed in a locker, overdue for servicing by 2 years. Vessel to remove or provide documentation of servicing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 17 June 2024
Resolution: System was removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 June 2024
Resolved
Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers. Vessel had no donning placards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 June 2024
Resolved 17 June 2024
Resolution: Donning placard posted.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 June 2024
Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies. Abandon ship and man overboard drills and training shall be logged or otherwise documented. Vessel had no running drill logs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 July 2024
Resolved 17 June 2024
Resolution: Rcvd document confirming drills performed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 June 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment. Vessel had daisy-chained power strips on bridge to power radios, cameras, and A/C unit. Vessel to find suitable length cables and ensure outlet is rated to provide the demanded electrical load.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 17 June 2024
Resolution: Daisy chains was removed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 4 June 2024
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Vessel first aid kits had expired and missing contents.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 17 June 2024
Resolution: New kit onboard.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 June 2024
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Vessel had no hotline or educational information posted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 17 June 2024
Resolution: EAP was added to the vessel's ops manual.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 4 June 2024
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Vessel had an old locker with faded lettering identifying it as for life jackets, no longer used for life jackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 17 June 2024
Resolution: Marking was covered.
Electrical › Electric Supply System (service) › Cable
Issued 7 May 2018
Resolved
Install approved battery cables, positive and negative on 02 main engines. 46CFR183.340(d)(2)(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 1 June 2018
Resolution: RCVD purchase invoice from vessel rep
Engineering › Fuel Oil Service System › Hose
Issued 7 May 2018
Resolved
Replace worn orange fuel oil supply hoses for main engines. 46CFR182.455
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 1 June 2018
Resolution: RCVD purchase invoice from vessel rep
Lifesaving › Lifebuoys › Serviceable
Issued 7 May 2018
Resolved
Replace 01 excessively worn life ring buoys near pilot house. 46CFR176.808(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2018
Resolved 1 June 2018
Resolution: RCVD purchase invoice from vessel rep
Electrical › Electric Supply System (service) › Cable
Issued 8 April 2017
Resolved
Install approved battery cables, positive and negative on all four main engines IAW 46CFR183.340(d)(2)(3).
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 20 June 2017
Electrical › Electric Supply System (service) › Battery Installation
Issued 8 April 2017
Resolved
Secure batteries from movement within all four main engine enclosures IAW 46CFR183.350(b).
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 20 June 2017
Engineering › Fuel Oil Service System › Hose
Issued 8 April 2017
Resolved
Replace worn fuel hoses and install hose clamps on various hoses with all four main engines IAW 46CFR182.455.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 20 June 2017
Engineering › Fuel Oil Service System › Hose
Issued 8 April 2017
Resolved
Replace generator fuel oil hose run from supply piping to generator housing with approved hose IAW 46CFR182.455.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 20 June 2017
Engineering › Fuel Oil Service System › Hose
Issued 8 April 2017
Resolved
Replace generator fuel oil hose and clamp from low pressure fuel oil pump to fuel manifold IAW 46CFR182.455.
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 20 June 2017
Lifesaving › Lifebuoys › Serviceable
Issued 8 April 2017
Resolved
Replace 02 excessively worn life ring buoys on the vehicle deck IAW 46CFR176.808(b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 20 June 2017
Fire Fighting › Fire Hoses › Condition
Issued 8 April 2017
Resolved
Replace fire hose at fire station by the #3 main engine IAW 46CFR176.810(c).
Condition: Improper/Lack of Maintenance
Due 8 April 2017
Resolved 8 April 2017
Resolution: New fire hose was brought onboard and hydro tested with ships fire main pressure, all sat.