MAURY USCG vessel records Sign in
← All vessels

NOBLE JOHN SANDIFER

NOBLE JOHN SANDIFER is a 1975 mobile offshore drilling unit. The Coast Guard has recorded 96 inspections since 1983, most recently in June 2005, along with 145 deficiencies and 1 casualty investigation in 2007.

Records from 1983 to 2007. Most recent: casualty investigation, 21 August 2007.

Built
1975
Last inspected
9 June 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8751576 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
LIBERIA
—
Maury page id
psix-53159

Inspections, by type

…with no type recorded36
Years with a record 22 calendar years (1983–2005)
The 96 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1773 - Convention (Subpart B), Net Ton
5912 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 96

9 June 2005 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2548669
1 June 2004 Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2078014
16 January 2004 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1986733
3 September 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1895922
2 July 2003 Periodic Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1833257
22 October 2002 Examination of Repairs · Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1842704
3 October 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1687186
25 July 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1655941
22 March 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1495899
11 March 2002 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1492710
6 March 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1491687
23 February 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1488706
11 October 2001 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1075337
17 August 2001 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1370337
6 July 2001 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1067592
21 May 2001 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1063556
7 February 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 112956
20 June 2000 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1469972
24 April 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1048788
8 December 1999 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 812532
22 June 1999 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1466625
20 November 1998 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 811135
20 November 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1413455
4 November 1998 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 811134
21 July 1998 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1473193
1 July 1998 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1128037
27 May 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 792066
1 April 1998 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1409877
18 December 1997 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1117702
16 October 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1109418
19 September 1997 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1110514
17 June 1997 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1364203
14 May 1997 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1104938
27 January 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1102139
23 October 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1164142
31 July 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1089619
25 July 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1088697
21 June 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465874
18 June 1996 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 885492
14 May 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 654267
25 April 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 764780
15 April 1996 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1081780
12 April 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 204455
3 March 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 193889
29 January 1996 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1191024
4 December 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1183415
17 November 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357390
6 November 1995 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 882889
6 July 1995 Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1390085
4 July 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 113994
3 July 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1192119
20 January 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1428432
16 December 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 839914
6 December 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1138465
20 May 1994 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1419281
28 February 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1163426
14 February 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 853206
18 January 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1161903
21 November 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 109415
1 November 1993 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 836405
15 October 1993 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462359
11 August 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 847362
13 July 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 847550
25 June 1993 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1155922
7 April 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1399870
5 December 1991 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1439304
10 July 1991 Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1245777
11 June 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1035395
7 June 1991 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 935666
13 January 1991 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1225029
14 September 1990 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1225028
26 June 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 920297
9 April 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1221440
7 April 1990 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 913141
5 April 1990 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 918772
23 January 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 923437
21 December 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1233772
23 October 1989 Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 891440
14 December 1988 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 897874
8 September 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1349468
27 January 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1019825
25 January 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321924
31 December 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009539
28 December 1987 COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1315717
2 March 1987 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1017325
9 May 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1305763
7 August 1985 Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1297168
8 July 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 983960
26 April 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 980955
22 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977845
29 May 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973498
14 May 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973494
17 April 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973491
20 July 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1273376
25 June 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1278040
26 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272238

Deficiency record · 145

Electrical › Electrical Distribution System (service) › Wiring
Issued 4 June 2004 Resolved
Prove all H2S alarm equipment (ie) Cables, fixtures and fittings are suitable for the hazardous location they are located at.
Due 4 July 2004
Resolved 27 August 2004
Operations/Management › Drills/Instruction
Issued 10 July 2003 Resolved
Update station bill to reflect accurate lifeboat commander assignments.
Due 10 August 2003
Resolved 27 August 2003
Operations/Management › Drills/Instruction
Issued 10 July 2003 Resolved
Provide proof of CG approval for Rev. 5 of operating manual Dtd. 06 JAN 98.
Due 10 September 2003
Resolved 16 January 2004
Operations/Management › Drills/Instruction
Issued 10 July 2003 Resolved
Provide proof of approval for Rev. 5 of fire and safety plan - plan must show installed portable quarters building.
Due 10 October 2003
Resolved 16 January 2004
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 10 July 2003 Resolved
Provide proof of approval for installation of portable quarters building or request approval by submission of all information IAW D8 RP-98-01. Fire detection system must interface with main system.
Due 10 August 2003
Resolved 27 August 2003
Electrical › Electric Generation Source (service)
Issued 10 July 2003 Resolved
Repair improper electrical splices on all generators.
Due 10 August 2003
Resolved 27 August 2003
Electrical › Electrical Distribution System (service)
Issued 10 July 2003 Resolved
Repair all open bulkhead penetrations in mud pit room- Prove all doors and Blkhds in mud pit room are gas tight. Adjust both watertight doors to ensure proper closure.
Due 10 August 2003
Resolved 27 August 2003
Electrical
Issued 10 July 2003 Resolved
Prove purge alarms for closed circuit TV monitor.
Due 10 August 2003
Resolved 27 August 2003
Lifesaving › Inflatable Liferafts
Issued 10 July 2003 Resolved
Provide replacement for expired 25 man liferaft. Max POB limited to 75 persons till this requirement is cleared.
Due 10 August 2003
Resolved 27 August 2003
Lifesaving › Lifeboat
Issued 10 July 2003 Resolved
Adjust limit switches on all 3 lifeboats, and repair faulty ones as required.
Due 10 August 2003
Resolved 27 August 2003
Lifesaving › Lifeboat Equipment
Issued 10 July 2003 Resolved
Provide fire extinguisher for discharged extinguisher in #3 lifeboat.
Due 10 August 2003
Resolved 27 August 2003
Lifesaving › Lifebuoys
Issued 10 July 2003 Resolved
Provide required retro on all liferings and replace faded retro on others.
Due 10 August 2003
Resolved 27 August 2003
Lifesaving › Lifejacket/PFD (General)
Issued 10 July 2003 Resolved
Provide CG approved working lights approved under 46 CFR 161.112 for all lifejackets & provide whistles for those missing.
Due 10 August 2003
Resolved 27 August 2003
Lifesaving › Lifeboat
Issued 2 July 2003 Resolved
Provide proof of launching and testing of sprinkler system in all 3 lifeboats all 3 lifeboats must be launched and operated in water quarterly thereafter.
Due 10 August 2003
Resolved 27 August 2003
Documentation › Safety/Response Plans/Programs
Issued 15 November 2002 Resolved
PROVIDE APPROVED PLANS FOR FIXED FIRE AND GAS DETECTION SYSTEM AND MAKE ANY NECESSARY CHANGES TO SYSTEM NEEDED AFTER USCG MARINE SAFETY CENTER AND ABS REVIEW.
Due 1 September 2003
Resolved 17 January 2004
Electrical › Lighting (service)
Issued 15 November 2002 Resolved
REPAIR/REPLACE BROKEN LIGHT COVER NEAR BATTERY BOX.
Due 15 December 2002
Resolved 1 March 2003
Resolution: RECEIVED FAX CONFIRMATION FROM OIM.
Electrical › Lighting (service)
Issued 15 November 2002 Resolved
REPLACE MISSING LIGHT COVER IN GALLEY.
Due 15 December 2002
Resolved 1 March 2003
Resolution: RECEIVED FAX CONFIRMATION FROM OIM.
Electrical › Electric Supply System (service)
Issued 15 November 2002 Resolved
RUN 110 POWER TO NEW FIRE PANEL.
Due 15 December 2002
Resolved 1 March 2003
Resolution: RECEIVED FAX CONFIRMATION FROM OIM.
Construction/Loadline › Structures
Issued 15 November 2002 Resolved
REPAIR RUSTED BOTTOM IN VENT BOX TO PRELOAD 2 PF.
Due 15 December 2002
Resolved 1 March 2003
Resolution: RECEIVED FAX CONFIRMATION FROM OIM.
Electrical
Issued 15 November 2002 Resolved
PLUG/SEAL OPEN WIRE PENETRATIONS BETWEEN MUD PUMP AND MUD PIT ROOMS.
Due 15 December 2002
Resolved 1 March 2003
Resolution: RECEIVED FAX CONFIRMATION FROM OIM.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 15 November 2002 Resolved
LABEL "A" & "B" ON CO2 RACK FOR PROPER IDENTIFICATION.
Due 15 December 2002
Resolved 1 March 2003
Resolution: RECEIVED FAX CONFIRMATION FROM OIM.
Accommodation/Occupational Safety › Occupational Safety
Issued 15 November 2002 Resolved
GREASE DOGS ON NEW WTD IN MUD PUMP ROOM.
Due 15 December 2002
Resolved 1 March 2003
Resolution: RECEIVED FAX CONFIRMATION FROM OIM.
Accommodation/Occupational Safety › Occupational Safety
Issued 15 November 2002 Resolved
REPAIR BOTTOM STEP IN STAIRWAY BETWEEN CEMENT & MUD PUMP ROOMS.
Due 15 December 2002
Resolved 1 March 2003
Resolution: RECEIVED FAX CONFIRMATION FROM OIM.
Deck/Cargo › Holds/Tanks
Issued 15 November 2002 Resolved
REPAIR DOUBLED SECTIONS, "POSTAGE STAMPS", ON SALTWATER LINE FROM PRELOAD 3 SF TO THE CEMEMNT ROOM.
Due 15 December 2002
Resolved 1 March 2003
Resolution: RECEIVED FAX CONFIRMATION FROM OIM.
Operations/Management › Drills/Instruction
Issued 25 July 2002 Resolved
46 CFR 109.213 Emergency drills: (c) conduct/document results of drills as required. ie. Adandon drill..must include..lowering lifeboats.
Due 25 August 2002
Resolved 23 August 2002
Resolution: REVIEWED LOG DURING FOLLOW-UP INSPECTION
Operations/Management › Equipment Service/Testing
Issued 25 July 2002 Resolved
46CFR 109.437 Crane Record Book: document results of inspections as required. Maintain records book as directed per reference cite.
Due 25 August 2002
Resolved 23 August 2002
Resolution: REVIEWED LOG DURING FOLLOW-UP INSPECTION
Engineering › Pressure Vessel
Issued 25 July 2002 Resolved
46 CFR 61.10-5 Pressure Vessels in service: Make all pressure vessels accessable for internal examination by USCG Marine Inspector or class surveyor. NDT is authorized inlieu of internal inspection if observed by either USCG or class surveyor.
Due 25 August 2002
Resolved 23 August 2002
Resolution: Received Class Surveyor observations of NDT and manufactures U1A sheets.
Electrical
Issued 25 July 2002 Resolved
Repair/Replace both mud pit doors to be gas tight to the satisfaction of the attending CG Marine Inspector or Class Surveyor.
Due 24 September 2002
Resolved 15 November 2002
Resolution: MUD PIT DOORS REPLACED & MET SATISFACTION OF CG & ABS.
Fire Fighting
Issued 17 August 2001 Resolved
MAKE PERMANANT REPAIRS TO THE PAINT LOCKER DOOR AND BULKHEAD.
Condition: Unknown
Due 17 August 2001
Resolved 17 August 2001
Accommodation/Occupational Safety
Issued 17 August 2001 Resolved
REMOVE FIBERGLASS GRATING AROUND THE GENERATORS IN THE MACHINERY SPACE.
Condition: Unknown
Due 17 August 2001
Resolved 17 August 2001
Construction/Loadline
Issued 17 August 2001 Resolved
CROP AND RENEW HOLED SECTION OF THE SUPERSTRUCTURE AT THE 2ND DECK/PORT/AFT_x001C_
Condition: Unknown
Due 30 November 2001
Resolved 11 March 2002
Lifesaving
Issued 17 August 2001 Resolved
REMOVE (11) PORTABLE OXYGEN BOTTLES FROM STOREROOM. REMOVE (1) CO2 BOTTLE FROM BEHIND PAINT LOCKER.
Condition: Unknown
Due 17 August 2001
Resolved 17 August 2001
Construction/Loadline
Issued 17 August 2001 Resolved
CROP AND RENEW WASTED SECTIONS OF BULKHEAD WHERE HOLED AT THE JUNCTION OF THE SUPERSTRUCTURE AND DECK. REMOVE DOUBLERS AND INSERT TO GOOD STEEL.
Condition: Unknown
Due 30 November 2001
Resolved 11 March 2002
Deck/Cargo
Issued 17 August 2001 Resolved
GAUGE AND DETERMINE WASTAGE AND/OR CROP AND RENEW WASTED SECTION OF THE DRILL WATER MANIFOLD IN THE MUD PUMP ROOM.
Condition: Unknown
Due 17 August 2001
Resolved 17 August 2001
Electrical
Issued 20 June 2000 Resolved
INSTALL AND PROVE PROPER OPERATION OF TOTAL RIG SHUTDOWN SYSTEM.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Engineering
Issued 20 June 2000 Resolved
RENEW COMPONENTS AND/OR MODIFY DIESEL ENGINE AIR START SYSTEM TO PROVIDE FOR RELIABLE CONSISTANT STARTING CAPABILITIES.
Condition: Unknown
Due 14 July 2000
Resolved 21 July 2000
Construction/Loadline
Issued 20 June 2000 Resolved
PROVIDE CLASS REPORT ATTESTING TO COMPLETION OF SPECIAL SURVEY.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Electrical
Issued 20 June 2000 Resolved
RENEW INOPERATIVE SYNCROSCOPE FREQUENCY METER AT MAIN SWITCHBOARD.
Condition: Unknown
Due 14 July 2000
Resolved 19 July 2000
Lifesaving
Issued 20 June 2000 Resolved
REPAIR INOPERATIVE GENERAL ALARM BELL IN MUD PIT ROOM.
Condition: Unknown
Due 30 June 2000
Resolved 19 July 2000
Lifesaving
Issued 20 June 2000 Resolved
PLACE FIRE DAMPER LOCATION SIGN ON AIR CONDITIONING RM 0N 1ST DECK.
Condition: Unknown
Due 27 June 2000
Resolved 19 July 2000
Construction/Loadline
Issued 20 June 2000 Resolved
COMPLETE PHASE II OF 2000 SEILOD.
Condition: Unknown
Due 20 June 2000
Resolved 20 June 2000
Lifesaving
Issued 22 June 1999 Resolved
46 CFR 109.301(i)(5) requires the lifeboat release gear to be tested under load. test was not able to be completed at inspection.
Condition: Unknown
Due 22 June 1999
Resolved 22 June 1999
Accommodation/Occupational Safety
Issued 21 July 1998 Resolved
PROVIDE A SUITABLE SPACE ONBOARD TO SERVE AS A TREATMENT/ISOLATION ROOM AS PER 46 CFR 108.210
Condition: Unknown
Due 21 August 1998
Resolved 21 August 1998
Lifesaving
Issued 21 July 1998 Resolved
PROVIDE ONBOARD SUFFICIENT RATIONS (LIFEBOATS/3) TO MEET REQUIREMENTS OF 46CFR 108.575 AND TABLE 108.575(b) FOR INTERNATIONAL SERVICE AS PER 46 CFR 107.111.
Condition: Unknown
Due 21 July 1998
Resolved 21 July 1998
Construction/Loadline
Issued 1 April 1998 Resolved
COMPLETE BOTTOM SECTION OF SEILODD INSPECTION PRIOR TO 06JUL98 TO THE SATISFACTION OF LOCAL COGNIZANT OCMI.
Condition: Unknown
Due 1 April 1998
Resolved 1 April 1998
Electrical
Issued 21 June 1996 Resolved
CONDUCT EMERGENCY DRILLING OPS SHUTDOWN.
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Electrical
Issued 21 June 1996 Resolved
REPLACE MAIN DISTRIBUTION PANEL IN SCR ROOM.
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Fire Fighting
Issued 21 June 1996 Resolved
CROP AND RENEW FIRE MAIN PIPING ON #2 FIRE PUMP.
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Accommodation/Occupational Safety
Issued 21 June 1996 Resolved
REPAIR LEAKING PIPES ON MARINE SANITATION DEVICE.
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Engineering
Issued 21 June 1996 Resolved
INSTALL FLAME IMPINGEMENT BOWLS ON GENERATOR FUEL FILTERS.
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Navigation
Issued 21 June 1996 Resolved
INSTALL PROPER BULBS ON ALL NAVIGATION LIGHTS.
Condition: Unknown
Due 21 June 1996
Resolved 21 June 1996
Documentation
Issued 17 November 1995 Resolved
SUBMIT VIDEO AND FINAL NDT REPORT TO [name withheld], LA FOR REVIEW.
Condition: Unknown
Due 17 November 1995
Resolved 17 November 1995
Documentation
Issued 6 July 1995 Resolved
SUBMIT TO PATMS COPY OF FINAL STABILITY LETTER.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Documentation
Issued 6 July 1995 Resolved
SUBMIT TO PATMS OPERATIONS MANUAL AFTER REVIEWED BY MSC.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Documentation
Issued 6 July 1995 Resolved
SUBMIT APPROVED PLANS FROM MSC TO PATMS ON FIRE MAIN PIPING ARRANGEMENT.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Electrical
Issued 6 July 1995 Resolved
PROVIDE TO PATMS MANUFACTURER DATA OF AUXILIARY ELECTRICAL POWER SYSTEM (AEPS).
Condition: Unknown
Due 28 July 1995
Resolved 25 July 1995
Documentation
Issued 6 July 1995 Resolved
SUBMIT TO PATMS COPY OF FINAL ABS LOADLINE CERTIFICATE.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Electrical
Issued 6 July 1995 Resolved
PROVE OPERATION OF OVERSPEED TRIP TO AUXILIARY ELECTRICAL POWER SYSTEM (AEPS).
Condition: Unknown
Due 14 July 1995
Resolved 6 July 1995
Fire Fighting
Issued 6 July 1995 Resolved
PERMANENTLY MOUNT FIRE HOSE APPLICATORS TO HELO DECK AREA.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Engineering
Issued 6 July 1995 Resolved
PROVIDE PROOF OR PERFORM HYDROSTATIC TESTING OF DAY FUEL TANK FOR AEPS SYSTEM.
Condition: Unknown
Due 28 July 1995
Resolved 25 July 1995
Fire Fighting
Issued 6 July 1995 Resolved
PROVIDE ADDITIONAL LENGTHS OF FIRE HOSES AT ALL TOPSIDE MAIN DECK FIRE STATIONS.
Condition: Unknown
Due 12 July 1995
Resolved 12 July 1995
Documentation
Issued 6 July 1995 Resolved
SUBMIT APPROVED PLANS FROM MSC TO PATMS OF AUXILIARY ELECTRICAL POWER SYSTEM (AEPS).
Condition: Unknown
Due 31 August 1995
Resolved 27 September 1995
Construction/Loadline
Issued 6 July 1995 Resolved
COMPLETE PHASE II PORTION OF DRYDOCK EXAM AT NEXT RIG MOVE AND PRIOR TO NEXT DRILLING OPERATIONS.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Navigation
Issued 6 July 1995 Resolved
REPAIR FOG HORN AND PROVE PROPER OPERATION OF FOG HORN TIMER DELAY.
Condition: Unknown
Due 6 July 1995
Resolved 6 July 1995
Documentation
Issued 6 July 1995 Resolved
PROVIDE TO PATMS ABS INSPECTIONS REPORTS OF AIR/HYDRO TESTING OF VOID TANKSAND PRELOAD TANKS AND PIPING SYSTEMS.
Condition: Unknown
Due 31 July 1995
Resolved 28 July 1995
Fire Fighting
Issued 6 July 1995 Resolved
PROVIDE UPDATED CHANGES OF FIRE CONTROL PLANS TO PATMS.
Condition: Unknown
Due 28 July 1995
Resolved 27 September 1995
Fire Fighting
Issued 20 May 1994 Resolved
PROVIDE COPY OF LAST FIRE FIGHTING SERVICE REPORT TO MSO PORT ARTHUR, TEXASFOR REVIEW.
Condition: Unknown
Due 20 May 1994
Resolved 20 May 1994
Engineering
Issued 20 May 1994 Resolved
ADJUST AND PROVE PROPER OPERATION OF THE NUMBER TWO MAIN GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 20 May 1994
Resolved 20 May 1994
Construction/Loadline
Issued 15 October 1993 Resolved
SUBMIT PROPOSAL FOR PERMENANT REPAIRS TO THE BOW AND STARBOARD LEG TO MSO MORGAN CITY. REPAIR TO BE COMPLETED DURING NEXT RIG MOVE.
Condition: Unknown
Due 14 February 1994
Resolved 7 December 1993
Construction/Loadline
Issued 15 October 1993 Resolved
CROP AND RENEW UNDER DECK BEAM IN #4 STARBOARD PRELOAD TANK NEXT TO CRANE PEDESTAL.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Construction/Loadline
Issued 15 October 1993 Resolved
COMPLETE INTERNAL HULL EXAM AND INSPECTION OF ALL SEA VALVES.
Condition: Unknown
Due 14 December 1993
Resolved 7 December 1993
Deck/Cargo
Issued 15 October 1993 Resolved
LOAD TEST STARBOARD CRANE PRIOR TO PUTTING CRANE IN SERVICE.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Documentation
Issued 25 June 1993 Resolved
PROVIDE TRANSFER PROCEDURES AS PER 33CFR155.720 CONTAINING WHAT'S SPECIFIEDIN 33CFR155.750, PERMANENTLY POSTED OR AVAILIBLE AT A PLACE WHERE THE PROCEDURES CAN BE SEEN WHEN ENGAGED IN TRANSFER OPS.
Condition: Unknown
Due 25 July 1993
Resolved 16 July 1993
Navigation
Issued 25 June 1993 Resolved
REPAIR PORT & STBD OBSTRUCTION LIGHTS TO BRING UP TO FULL CAPABILITY.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Lifesaving
Issued 25 June 1993 Resolved
PAINT BOTH LIFE CAPSULES INTERNATIONAL ORANGE.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Lifesaving
Issued 25 June 1993 Resolved
PROVIDE DOCUMENTATION OF SATISFACTORY WEIGHT TEST OF LIFE RAFT DAVIT.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Documentation
Issued 25 June 1993 Resolved
SUBMIT FOR APPROVAL AND MAINTAIN COPY ON BOARD OF MODU EMERGENCY EVACUATIONPLAN IAW 33CFR146.210.
Condition: Unknown
Due 25 July 1993
Resolved 13 July 1993
Deck/Cargo
Issued 25 June 1993 Resolved
PROVIDE DOCUMENTATION OF AND/OR CONDUCT ABS ANNUAL CRANE SURVEY AND PROOF LOAD TEST.
Condition: Unknown
Due 25 June 1993
Resolved 25 June 1993
Unknown
Issued 10 July 1991 Resolved
SUBMIT PROPOSAL AND EFFECT REPAIRS TO CRACKS IN BOW AND STARBOARD LEG/CAN CONNECTIONS IDENTIFIED AS D-1, D-3, D-4, & D-5 IN THE DIVING REPORT FOR THESPECIAL EXAMINATION IN LIEU OF DRYDOCK CONDUCTED 14-17 NOVEMBER 1990 PRIOR TO BEGINNING NEXT OPERATION PER MSO PORT ARTHUR LETTER OF 11 JULY 1991.
Condition: Unknown
Due 10 July 1991
Resolved 10 July 1991
Construction/Loadline
Issued 26 June 1990 Resolved
WASTED SEATING SERFACES FOR DUMP VALVES LOCATED IN 2S, 5S, 5P, AND 4P PRELOAD TANKS.
Condition: Unknown
Due 26 June 1990
Resolved 26 June 1990
Documentation
Issued 7 April 1990 Resolved
SUBMIT OPERATIONS MANUAL FOR COAST GUARD APPROVAL.
Condition: Unknown
Due 7 April 1990
Resolved 7 April 1990
Construction/Loadline
Issued 7 April 1990 Resolved
COMPLETE WORKLISTS DATED 05APR90 AND 07APR90.
Condition: Unknown
Due 7 April 1990
Resolved 7 April 1990
Documentation
Issued 7 April 1990 Resolved
OBTAIN A FULL TERM LOADLINE FROM ABS.
Condition: Unknown
Due 7 April 1990
Resolved 7 April 1990
Construction/Loadline
Issued 7 April 1990 Resolved
CONDUCT A DRYDOCK EXAM FOR CREDIT OR SUBMIT A PROPOSAL FOR SPECIAL UNDER- WATER EXAM IN LIEU OF DRYDOCKING.
Condition: Unknown
Due 7 April 1990
Resolved 7 April 1990
Documentation
Issued 7 April 1990 Resolved
PROVIDE ON BOARD CURRENT CRANE CERTIFICATES AND SUBMIT COPY OF SAME TO OCMIPORT ARTHUR, TX.
Condition: Unknown
Due 7 April 1990
Resolved 7 April 1990
Construction/Loadline
Issued 28 December 1987 Resolved
COMPLETE UNDERWATER VIDEO PORTION OF EXAM.
Condition: Unknown
Due 28 December 1987
Resolved 28 December 1987
Fire Fighting
Issued 28 December 1987 Resolved
PROVIDE RESULTS OF LIGHTWATER SAMPLE TEST
Condition: Unknown
Due 28 December 1987
Resolved 28 December 1987
Lifesaving
Issued 28 December 1987 Resolved
CONDUCT WEIGHT TEST OF BOTH LIFE CAPSULES AND EXAMINE DAVIT SYSTEM
Condition: Unknown
Due 28 December 1987
Resolved 28 December 1987
Fire Fighting
Issued 28 December 1987 Resolved
PROVIDE 1 ADDITIONAL O2 COMBUST. GAS INDICATOR
Condition: Unknown
Due 28 December 1987
Resolved 28 December 1987
Electrical
Issued 28 December 1987 Resolved
DEMONSTRATE OPERATION OF FAN IN DOG HOUSE STBD SIDE.
Condition: Unknown
Due 28 December 1987
Resolved 28 December 1987
Lifesaving
Issued 28 December 1987 Resolved
CONDUCT EXAMINATION OF REQUIRED CAPSULE EQUIPMENT
Condition: Unknown
Due 28 December 1987
Resolved 28 December 1987
Electrical
Issued 28 December 1987 Resolved
REPLACE MISSING HELIPORT PERIF. GLOBES
Condition: Unknown
Due 28 December 1987
Resolved 28 December 1987
Lifesaving
Issued 28 December 1987 Resolved
CONDUCT EMERGENCY DRILLS
Condition: Unknown
Due 28 December 1987
Resolved 28 December 1987
Construction/Loadline
Issued 8 July 1985 Resolved
CONDUCT A VIDEO SCAN OF THE LEGS, SPUD CANS, HIGH STRESS AREAS. CONDUCT NON-DESTRUCTIVE TESTING OF THE HIGH STRESS AREAS OF THE LEG TO CAN CONNEC- TIONS.
Condition: Unknown
Due 8 July 1985
Resolved 8 July 1985
Unknown
Issued 22 April 1985 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL, DIAMOND M. GEM, DN569799 AND ARE TO BE COMPLIED WITH BY 22MAY85.
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985
Fire Fighting
Issued 22 April 1985 Resolved
PROVIDE AN OXYGEN BOTTLE FOR FIREMAN'S OUTFIT. 46 CFR 108.497.
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985
Fire Fighting
Issued 22 April 1985 Resolved
REPLACE THE INOPERATIVE PRESSURE GUAGE FOR THE FIRE PUMP. 46 CFR 108.417(D)
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985
Construction/Loadline
Issued 22 April 1985 Resolved
PROVIDE DECK RALL AND CHAIN WHERE MISSING BELOW DRILL FLOOR. 46 CFR 108.217.
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985
Lifesaving
Issued 22 April 1985 Resolved
REPLACE THE BROKEN EMERGENCY LIGHT TO THE PORT CAPSULE SECTION. 46 CFR 111.75-15.
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985
Electrical
Issued 22 April 1985 Resolved
MAKE OPERATIVE THE WATER HIGH TEMPERATURE ALARM ON THE NUMBER 2 MAIN EMD GENERATOR. 46 CFR 58.10.
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985
Engineering
Issued 22 April 1985 Resolved
PROVIDE A RELIEF VALVE WITH A HAND RELIEVING DEVICE ON IT FOR THE DRILL FLOOR AIR RECEIVER. 46 CFR 54.
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985
Unknown
Issued 22 April 1985 Resolved
REMOVE THE WELDING MACHINE AWAY FROM THE MUD EXHAUST VENT AND OUTSIDE THIS HAZARDOUS LOCATION. 46 CFR 111.105.
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985
Electrical
Issued 22 April 1985 Resolved
INSTALL COVER PANELS OVER SWITCH OPENNING ON ROWAN ITE IMPERIAL CORP. MAIN BUS SWITCHBOARD THE SWITCHBOARD FOR THE NUMBER TWO AIR COMPRESSOR THE SWITCHBOARD FOR THE WATERMAKER AND THE SWITCHBOARD FOR THE MUD NUMBER ONE MUD CHARGING UNIT. 46 CFR 111.30-5(D).
Condition: Unknown
Due 22 April 1985
Resolved 22 April 1985
Unknown
Issued 17 April 1984 Resolved
PROVIDE EVIDENCE FUEL TAKE ON HOSES MEET 33 CFR 154.500.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Electrical
Issued 17 April 1984 Resolved
REPAIR OR REPLACE EMERGENCY BATTERY BOXES AS NEEDED, (I.E. VENT, CHOCK, PROVIDE ACID RESISTANT LINING), AND LABEL.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Electrical
Issued 17 April 1984 Resolved
REPAIR DEFECTIVE BUNK LIGHTS AND EXHAUST VENTS IN QUARTERS AS NEEDED.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Fire Fighting
Issued 17 April 1984 Resolved
REPAIR ALL DEFECTIVE FIRE DOORS IN QUARTERS AS NEEDED.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Documentation
Issued 17 April 1984 Resolved
PROVIDE ON BOARD MODU INTERNATIONAL CODE OF SIGNALS.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Fire Fighting
Issued 17 April 1984 Resolved
PROVIDE ON BOARD MODU OXYGEN METERS FOR FIREMEN'S OUTFITS.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Documentation
Issued 17 April 1984 Resolved
PROVIDE EVIDENCE CRANES HAVE BEEN INSPECTED ANNUALLY BY AUTHORIZED AGENCY TO APPLICABLE API STANDARDS.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Fire Fighting
Issued 17 April 1984 Resolved
PROVIDE EVIDENCE THAT SECOND EXPLOSIMETER IS UL OR FM APPROVED OR REPLACE WITH APPROVED TYPE.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Electrical
Issued 17 April 1984 Resolved
PROVIDE ADEQUATE EMERGENCY LIGHTING FOR BOTH CAPSULES.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Electrical
Issued 17 April 1984 Resolved
REWIRE EMERGENCY GENERATOR BATTERY CHARGER.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Unknown
Issued 17 April 1984 Resolved
INSTALL PROPER RELIEVING DEVICES IN ALL SIX BULK TANKS SO AS TO RELIEVE AT OR BELOW 40 PSI AND TEST.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Electrical
Issued 17 April 1984 Resolved
PLACE CIRCUIT DIRECTORY IN GENERAL ALARM FUSE BOX (FUSE SIZES, AREA SUPPLIED, CIRCUIT DESIGNATION).
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Electrical
Issued 17 April 1984 Resolved
REPAIR OR REPLACE #2 GENERATOR REVERSE POWER RELAY.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Electrical
Issued 17 April 1984 Resolved
TEST GENERATOR OVERSPEEDS AND LOW LUBE OIL SHUT DOWNS ON #1 - #3 GENERATORS.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Unknown
Issued 17 April 1984 Resolved
REMOVE ALL LOCKING DEVICES.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Unknown
Issued 17 April 1984 Resolved
POP TEST RELIEF VALVES INSTALLED IN ALL THREE AIR RECEIVERS AND TWO SANITARY WATER TANKS.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Unknown
Issued 17 April 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE DIAMOND M GEM, DN569799.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Electrical
Issued 17 April 1984 Resolved
REPAIR PURGE ALARMS ON MARTIN DECKER MONITOR.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Electrical
Issued 17 April 1984 Resolved
SUPPORT WIRING AT SPECIFIED LOCATIONS THROUGHOUT THE RIG.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Electrical
Issued 17 April 1984 Resolved
CLEAR PARTIAL GROUND ON PANEL P-121 ("A" PHASE).
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Electrical
Issued 17 April 1984 Resolved
LABEL ALL MOTOR CONTROLLERS.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Documentation
Issued 17 April 1984 Resolved
PROVIDE ON BOARD CONSTRUCTION PORTFOLIO AS REQUIRED BY CERTIFICATION OF INSPECTION.
Condition: Unknown
Due 17 April 1984
Resolved 17 April 1984
Construction/Loadline
Issued 20 July 1983 Resolved
CROP AND RENEW THE WASTED ANGLE STIFFENERS IN WAY OF THE PRELOAD FILL SPOOL PIECES IN THE FOLLOWING TANKS: #4 PORT FWD, #5 STBD FWD,
Condition: Unknown
Due 20 July 1983
Resolved 20 July 1983
Construction/Loadline
Issued 20 July 1983 Resolved
CONDUCT NONDESTRUCTIVE TESTING AND MAKE SATISFACTORY PERMANENT REPAIRS TO THE SQUARE INSERT IN WAY OF FR. 6.5, STBD SIDESHELL AT THE 15'6" AND 18'3"
Condition: Unknown
Due 20 July 1983
Resolved 20 July 1983
Construction/Loadline
Issued 20 July 1983 Resolved
PROVIDE WEEPHOLES FOR ADEQUATE DRAINAGE IN TANK NO.5 STBD FORWARD.
Condition: Unknown
Due 20 July 1983
Resolved 20 July 1983
Construction/Loadline
Issued 20 July 1983 Resolved
RENEW OR MAKE PERMANENT REPAIRS TO THE DUMP- VALVE IN THE NO. 5 STBD AFT PRELOAD TANK.
Condition: Unknown
Due 20 July 1983
Resolved 20 July 1983
Construction/Loadline
Issued 25 June 1983 Resolved
SUBMIT FOR APPROVAL THE MODIFICATIONS PLAN(S) OF THE SPUDCANS TO COMMANDER (MMT), EIGHTH COAST GUARD DISTRICT.
Condition: Unknown
Due 25 June 1983
Resolved 25 June 1983
Construction/Loadline
Issued 25 June 1983 Resolved
NEW INSTALLATIONS, CHANGES OR MODIFICATIONS TO PLANS ARE REQUIRED TO BE SUBMITTED FOR APPROVAL. ALL COMMENTS MUST BE SATISFIED WITHIN 30 DAYS OF
Condition: Unknown
Due 25 June 1983
Resolved 25 June 1983
Electrical
Issued 26 April 1983 Resolved
REPAIR LUBE OIL ALARM FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 26 April 1983
Resolved 26 April 1983
Unknown
Issued 26 April 1983 Resolved
REPAIR OR REPLACE RELIEF VALVE ON NO.2 MUD PUMP.
Condition: Unknown
Due 26 April 1983
Resolved 26 April 1983
Unknown
Issued 26 April 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAINS TO THE VESSEL DIAMOND M. GEM, DN569799
Condition: Unknown
Due 26 April 1983
Resolved 26 April 1983
Electrical
Issued 26 April 1983 Resolved
MAKE SOUND POWERED PHONES IN SHAKER AREA AND ON DRILL FLOOR SUITABLE FOR HAZARDOUS LOCATION.
Condition: Unknown
Due 26 April 1983
Resolved 26 April 1983
Fire Fighting
Issued 26 April 1983 Resolved
INSTALL A FIRE STATION TO SERVE THE DRILL FLOOR.
Condition: Unknown
Due 26 April 1983
Resolved 26 April 1983
Electrical
Issued 26 April 1983 Resolved
REPAIR OBSTRUCTION LIGHT BATTERY.
Condition: Unknown
Due 26 April 1983
Resolved 26 April 1983
Documentation
Issued 26 April 1983 Resolved
PROVIDE CONSTRUCTION PORTFOLIO ABOARD RIG.
Condition: Unknown
Due 26 April 1983
Resolved 26 April 1983
Navigation
Issued 26 April 1983 Resolved
PROVIDE ONE (1) SHIP'S BELL ABOARD RIG.
Condition: Unknown
Due 26 April 1983
Resolved 26 April 1983
Fire Fighting
Issued 26 April 1983 Resolved
PROVIDE MARINE BRACKETS FOR ALL PORTABLE FIRE EXTINGUISHERS NOT SO EQUIPPED.
Condition: Unknown
Due 26 April 1983
Resolved 26 April 1983
Fire Fighting
Issued 26 April 1983 Resolved
MAKE RIG AIR RECEIVER UNDER DRILL FLOOR AVAILABLE FOR INTERNAL EXAM.
Condition: Unknown
Due 26 April 1983
Resolved 26 April 1983
Electrical
Issued 26 April 1983 Resolved
PROVIDE NON CORROSIVE LINING OR BOX FOR EMERGENCY AIR COMPRESSOR START BATTERY.
Condition: Unknown
Due 26 April 1983
Resolved 26 April 1983
Electrical
Issued 26 April 1983 Resolved
REPAIR GENERAL ALARM BELL IN MUD PITS AND PROVIDE A GENERAL ALARM BELL IN THE SCR ROOM.
Condition: Unknown
Due 26 April 1983
Resolved 26 April 1983
Accommodation/Occupational Safety
Issued 26 April 1983 Resolved
PROVIDE RELIEF VALVE FOR PORTABLE WATER TANK.
Condition: Unknown
Due 26 April 1983
Resolved 26 April 1983
Electrical
Issued 26 April 1983 Resolved
REPAIR MUD PIT VENTILATION FAILURE ALARM.
Condition: Unknown
Due 26 April 1983
Resolved 26 April 1983

Casualty record · 1

21 August 2007Routine · role: Involved in a Marine Casualty · activity 3037217
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.