Records from 1985 to 2006. Most recent: inspection, 28 February 2006.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 35
28 February 2006
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2593309
19 January 2005
Annual Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2268879
24 February 2004
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2000539
16 December 2003
Administrative Inspection
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1965150
3 November 2003
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1941165
26 February 2003
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1739574
12 February 2003
Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1741393
2 May 2002
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1611863
6 March 2002
Construction Oversight · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1485950
15 April 2001
COI Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1440467
27 February 2001
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1064658
25 September 2000
Plan Review "T" Boat
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1455920
19 July 2000
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 821922
9 May 2000
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1436388
10 March 1999
Re-Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1406457
31 December 1998
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 815013
4 March 1998
Hull Examination · COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1422984
6 June 1996
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1091033
9 June 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1387813
11 April 1995
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 860320
16 June 1994
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1328322
4 April 1994
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1167954
28 May 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1147861
21 April 1993
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 835624
14 April 1992
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 959624
4 June 1991
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1312198
19 April 1991
Hull Examination · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1213178
24 May 1990
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 912464
24 April 1990
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 907755
9 May 1989
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 893168
1 August 1988
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1345995
10 May 1988
Deficiency Check · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1043879
14 April 1987
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1009000
30 April 1986
Credit Drydock · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1300382
17 April 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 983756
Engineering › Gasoline Engine (propulsion)
Issued 16 December 2003
Resolved
Properly install engine space ventilation blower as per 46 CFR 182.460. LEGACY COMPONENT DESC: Ventilation
Condition: Improper Installation
Due 17 March 2004
Resolved 25 February 2004
Construction/Loadline › Penetrations
Issued 3 November 2003
Resolved
Make proper repairs to through hull shaft fitting and float test vessel in the presence of a Coast Guard inspector. LEGACY COMPONENT DESC: Shaft through fitting
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 November 2003
Resolved 25 February 2004
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 26 February 2003
Resolved
Show proper operation of both hood closures.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2003
Resolved 2 April 2003
Construction/Loadline › Structures
Issued 26 February 2003
Resolved
Replace aft tube hinge bracket with proper bracket. LEGACY COMPONENT DESC: Hinge plate bracket
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2003
Resolved 2 April 2003
Lifesaving › Lifebuoys
Issued 26 February 2003
Resolved
Replace aft ring bouy.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2003
Resolved 2 April 2003
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 26 February 2003
Resolved
Properly mark aft bilge high alarm.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2003
Resolved 2 April 2003
Construction/Loadline › Hull
Issued 12 February 2003
Resolved
Determine the amount of corrosion to side shell. Sand blast hull and gage side shell. Crop out and renew any wasted areas and test for leaks. LEGACY COMPONENT DESC: Hull Plating
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 February 2003
Resolved 2 June 2003
Fire Fighting › Means of Escape › Number
Issued 6 March 2002
Resolved
Make proper repairs to Side curtain release.
Condition: Design Flaw
Due 6 April 2002
Resolved 7 March 2002
Stability › Watertight Integrity
Issued 6 March 2002
Resolved
Ensure Portside and aft watertight doors pass a 30 psi hose test. LEGACY COMPONENT DESC: Side and Stern Doors
Condition: Design Flaw
Due 6 April 2002
Resolved 8 May 2002
Lifesaving
Issued 10 March 1999
Resolved
Install approved first aid kit.
Condition: Unknown
Due 31 March 1999
Resolved 1 April 1999
Lifesaving
Issued 10 March 1999
Resolved
Remove or ensure side curtain straps are not secured when vessel is in the water.
Condition: Unknown
Due 15 March 1999
Resolved 19 March 1999
Navigation
Issued 11 April 1995
Resolved
PROVE OPERATION OF HORN.
Condition: Unknown
Due 11 April 1995
Resolved 11 April 1995
Documentation
Issued 11 April 1995
Resolved
POST GARBAGE POLLUTION PLACARD ON BOARD.
Condition: Unknown
Due 11 April 1995
Resolved 11 April 1995
Lifesaving
Issued 11 April 1995
Resolved
RENEW WASTED GRAB LINE ON LIFE RING BUOY.
Condition: Unknown
Due 11 April 1995
Resolved 11 April 1995
Construction/Loadline
Issued 4 April 1994
Resolved
REPLACE MISSING HINGED COVER AT PTO BILGE PIPING DISCHARGE TERMINATION.
Condition: Unknown
Due 4 April 1994
Resolved 4 April 1994
Lifesaving
Issued 21 April 1993
Resolved
PUT VESSEL MISSOURI NUMBER ON NEW LIFE JACKETS.
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Navigation
Issued 21 April 1993
Resolved
INSTALL SECOND CABLE CLAMP STEERING RUDDER CABLE, LOCATED IN STERN COMPARTMENT.
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Lifesaving
Issued 19 April 1991
Resolved
STENCIL VESSEL NAME ON RING BOUY.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Construction/Loadline
Issued 19 April 1991
Resolved
STENCIL VESSEL NAME ON STERN.
Condition: Unknown
Due 19 April 1991
Resolved 19 April 1991
Construction/Loadline
Issued 24 April 1990
Resolved
INSTALL FIXED SEATING.
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Documentation
Issued 24 April 1990
Resolved
MOUNT CERTIFICATE OF INSPECTION WITH BOTH PAGES VISIBLE TO PASSENGERS.
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Lifesaving
Issued 24 April 1990
Resolved
STENCIL/MARK LIFE PRESERVERS WITH VESSEL'S NAME.
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Lifesaving
Issued 24 April 1990
Resolved
PROPERLY STOW ALL LIFE PRESERVERS.
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Electrical
Issued 24 April 1990
Resolved
INSTALL BATTERY HOLD DOWN CLAMP.
Condition: Unknown
Due 24 April 1990
Resolved 24 April 1990
Construction/Loadline
Issued 10 May 1988
Resolved
REPAIR 6 INCH CRACK IN PORT SIDE COMBING.
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988