Records from 1984 to 1996. Most recent: inspection, 11 October 1996.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
11 October 1996
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 844730
12 January 1995
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1358633
31 March 1994
Hull Examination · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 859256
7 July 1993
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 844746
29 March 1993
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 842119
31 March 1992
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 948212
23 January 1992
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 948147
2 April 1991
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 997239
2 April 1990
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1225898
2 April 1989
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1209034
17 February 1989
Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1350217
17 June 1988
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 892422
14 April 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1335928
24 March 1986
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 985276
4 April 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1287585
28 December 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1285222
6 November 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1284151
Lifesaving
Issued 12 January 1995
Resolved
Povide 6 orange and 6 red flares of approved type._x001C_
Condition: Unknown
Due 20 January 1995
Resolved 20 January 1995
Documentation
Issued 29 March 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 29 March 1993
Resolved 29 March 1993
Lifesaving
Issued 31 March 1992
Resolved
PROVIDE 6 (SIX) CG APPROVED RED FLARES AND 6 (SIX) CG APPROVED ORANGE SMOKES, OR 12 (TWELVE) COMBINATION FLARES.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Deck/Cargo
Issued 2 April 1990
Resolved
PROVIDE SUITABLE SIZE ANCHOR AND LINE.
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990
Construction/Loadline
Issued 2 April 1990
Resolved
REPAIR CRACKED WELDS ON FORWARD THREE TRANSVERSE FRAMES, PORT AND STARBOARDSIDE AT SIDE SHELL ATTACHMENT.
Condition: Unknown
Due 2 April 1990
Resolved 2 April 1990
Lifesaving
Issued 17 February 1989
Resolved
MOUNT RING BUOY AND WATERLIGHT ON PROPER MOUNTING BRACKET.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989
Documentation
Issued 17 February 1989
Resolved
INSTALL POLLUTION PLACARD IN MACHINERY SPACE.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989
Documentation
Issued 17 February 1989
Resolved
CONDUCT A SIMPLIFIED STABILITY TEST FOR 48 PASSENGERS IN PRESENCE OF COAST GUARD INSPECTOR.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989
Documentation
Issued 17 February 1989
Resolved
PERMANENTLY MARK HULL IDENTIFICATION NUMBER IN HULL.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989
Fire Fighting
Issued 17 February 1989
Resolved
HYDROSTATICALLY TEST CO2 BOTTLE FOR FIXED FIREFIGHTING SYSTEM.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989
Engineering
Issued 17 February 1989
Resolved
LABEL FUEL SHUTOFF VALVES.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989
Engineering
Issued 17 February 1989
Resolved
REPLACE EXISTING FLEXIBLE FUEL HOSES WITH COAST GUARD ACCEPTABLE COMMERCIALFUEL HOSE.
Condition: Unknown
Due 17 February 1989
Resolved 17 February 1989
Construction/Loadline
Issued 24 March 1986
Resolved
CONDUCT A STABILITY TEST IN PRESENCES OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 24 March 1986
Resolved 24 March 1986
Lifesaving
Issued 24 March 1986
Resolved
LABEL LIFE JACKETS WITH VESSEL'S NAME.
Condition: Unknown
Due 24 March 1986
Resolved 24 March 1986
Lifesaving
Issued 24 March 1986
Resolved
LABEL LIFE JACKET CONTAINERS "LIFE PRESERVERS" AND NUMBER STOWED INSIDE.
Condition: Unknown
Due 24 March 1986
Resolved 24 March 1986
Engineering
Issued 24 March 1986
Resolved
LABEL FUEL SHUT OFF VALVE.
Condition: Unknown
Due 24 March 1986
Resolved 24 March 1986
Navigation
Issued 24 March 1986
Resolved
REPAIR STERN LIGHT.
Condition: Unknown
Due 24 March 1986
Resolved 24 March 1986
Lifesaving
Issued 24 March 1986
Resolved
PROVIDE 14 TYPE 1 ADULT AND 2 CHILDREN LIFE JACKETS. VESSEL IS LIMITED TO CARRYING 35 ADULTS UNTIL THIS ITEM IS COMPUTED.
Condition: Unknown
Due 24 March 1986
Resolved 24 March 1986
Engineering
Issued 24 March 1986
Resolved
REPLACE FUEL HOSE BETWEEN FILTER AND PUMP ON PORT AND STARBOARD ENGINES WITH COAST GUARD ACCEPTED HOSES.
Condition: Unknown
Due 24 March 1986
Resolved 24 March 1986
Lifesaving
Issued 24 March 1986
Resolved
RENEW RING BUOY WITH A COAST GUARD APPROVED BUOY. '
Condition: Unknown
Due 24 March 1986
Resolved 24 March 1986
Lifesaving
Issued 24 March 1986
Resolved
PROVIDE COAST GUARD APPROVED WATER LIGHT.
Condition: Unknown
Due 24 March 1986
Resolved 24 March 1986
Lifesaving
Issued 24 March 1986
Resolved
PROVIDE 6 HAND RED FLARE DISTRESS SIGNALS.
Condition: Unknown
Due 24 March 1986
Resolved 24 March 1986
Lifesaving
Issued 24 March 1986
Resolved
PROVIDE 6 HAND ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 24 March 1986
Resolved 24 March 1986
Navigation
Issued 24 March 1986
Resolved
PROVIDE ANCHOR LIGHT.
Condition: Unknown
Due 24 March 1986
Resolved 24 March 1986
Fire Fighting
Issued 4 April 1985
Resolved
SERVICE FIXED CO2 BOTTLE IN ENGINE ROOM.
Condition: Unknown
Due 4 April 1985
Resolved 4 April 1985
Navigation
Issued 4 April 1985
Resolved
REPAIR STERNLIGHT, PORT NAVLIGHT AND REPLACE STBD NAV LIGHT LENS.
Condition: Unknown
Due 4 April 1985
Resolved 4 April 1985
Fire Fighting
Issued 6 November 1984
Resolved
ENSURE THAT ALL VESSEL SAFETY EQUIPMENT IS PLACED ABOARD PRIOR TO EACH TIME VESSEL IS OPERATED.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Unknown
Issued 6 November 1984
Resolved
COMPLETE ALL PREVIOUSLY ISSUED CG-835 REQUIREMENTS.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Construction/Loadline
Issued 6 November 1984
Resolved
ARREST, VEE OUT, AND REWELD FRACTURED AREAS ON FOUR CORNERS OF PASSENGER COMPARTMENT AND ON THE FOUR CORNERS OF THE ENGINE COMPARTMENT. INSTALL KNEE BRACKET OR OTHER REINFORCEMENT TO PREVENT FRACTURES.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Electrical
Issued 6 November 1984
Resolved
INSTALL BATTERY BOXES WITH TOPS.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Construction/Loadline
Issued 6 November 1984
Resolved
INSTALL PERMANENT, HARD MATERIAL, FIRE-PROOF EXHAUST DUCTING ON PORT SIDE BLOWER AND ON STARBOARD EXHAUST PORT. CHECK AND SECURE AS NECESSARY THE CONNECTIONS ON ALL ENGINEROOM DUCTING.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Engineering
Issued 6 November 1984
Resolved
CONNECT OR REMOVE LOOSE WIRES ON BOTH ENGINES.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Construction/Loadline
Issued 6 November 1984
Resolved
SECURE THE BILGE PUMP IN THE ENGINEROOM.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Engineering
Issued 6 November 1984
Resolved
INSTALL WARNING SIGN FOR BLOWER OPERATION PRIOR TO STARTING ENGINES.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984
Fire Fighting
Issued 6 November 1984
Resolved
INSTALL BRACKETS FOR FIRE EXTINGUISHERS.
Condition: Unknown
Due 6 November 1984
Resolved 6 November 1984