MAURY USCG vessel records
← All vessels

CONCEPTION

Built
1981
Last inspected
7 August 2019
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 7 August 2019
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2016–2019)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WYR8548
Flag
UNITED STATES
Maury page id
psix-53173

Documentation record

Registered dimensions (L × B × D)75.0 ft × 25.0 ft × 6.0 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEAWAY BOAT · LONG BEACH, CA, UNITED STATES · built 1981
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSANTA BARBARA, CA
Endorsements, as the file codes themcw_un, reg
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it97 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 11 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 11

7 August 2019 In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6807826
10 March 2019 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6759996
13 February 2019 Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6625180
13 February 2019 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6625487
5 August 2018 Type not recorded
No type recorded · Station Channel Islands Harbor · USCG Southwest District (CGD-SW) · Activity 6501862
13 February 2018 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6345853
16 February 2017 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6086303
1 February 2017 Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6080655
18 January 2017 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6074077
19 March 2016 Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5955134
18 February 2016 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5817809

Deficiency record · 13

Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 February 2018 Resolved
Update expired items in first aid kit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 2 March 2018
Resolution: First aid kit updated.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 13 February 2018 Resolved
Update light list.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 13 February 2018
Resolution: Light list updated.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 13 February 2018 Resolved
Provide 2018 ASTS employee list.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 March 2018
Resolved 13 February 2018
Resolution: List provided.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 16 February 2017 Resolved
Replace B-I fire extinguisher on the bridge.
Action required: 705 - Other - as specified
Due 16 March 2017
Resolved 27 February 2017
Resolution: B-I replaced.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 16 February 2017 Resolved
Renew 40 lifejacket lights, vessel already restricted to 60 persons until new lifefloats are installed above the bridge.
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 16 February 2017
Resolution: Corrected on the spot.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 16 February 2017 Resolved
Document safety drills in logbook (fire, MOB, and abandonship).
Action required: 705 - Other - as specified
Due 16 February 2017
Resolved 16 February 2017
Resolution: Log updated after satisfactory drills were completed underway.
Engineering › Feedwater/Condensate Water System › Valve
Issued 1 February 2017 Resolved
Service or repalce (01) ball valve in E/R to ensure full closure.
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 9 February 2017
Electrical › Electrical Distribution System (service) › Panelboard
Issued 1 February 2017 Resolved
E/R: label 120V breaker panel and plug 2 holes on each side (4 total).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 9 February 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 February 2017 Resolved
Post all pages of COI
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 9 February 2017
Lifesaving › Lifefloat › Serviceable
Issued 18 January 2017 Resolved
Vessel is restricted to 60 persons until the two lifelfoats mounted above the wheelhouse are renewed and inspected.
Action required: 705 - Other - as specified
Due 31 March 2017
Resolved 17 April 2017
Resolution: New lifefloats installed and inspected.
Fire Fighting › Fire Pumps › Power Source
Issued 18 February 2016 Resolved
Prove proper operation of the fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2016
Resolved 19 February 2016
Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 18 February 2016 Resolved
Prove proper operation of the heat detector in the galley.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 24 February 2016
Resolution: Heat detector replaced and tested sat.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 18 February 2016 Resolved
Provide suitable cover on motor controller for aft compressor.
Action required: 705 - Other - as specified
Due 18 March 2016
Resolved 19 February 2016

Ownership record