ODIN WARWICK

ODIN WARWICK is a 1971 mobile offshore drilling unit. The Coast Guard has recorded 94 inspections since 1982, most recently in September 2005, along with 274 deficiencies and 1 casualty investigation in 2005.

Records from 1982 to 2005. Most recent: inspection, 9 September 2005.

Built
1971
Last inspected
9 September 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCE8415
Flag
UNITED STATES
—
Maury page id
psix-53183

Inspections, by type

…with no type recorded36
Years with a record 22 calendar years (1982–2005)
The 94 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1926 - Convention (Subpart B), Net Ton
6421 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCE8415MMSI not assigned · expired · voluntarily equipped · granted 29 March 1994, cancelled 30 May 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 94

9 September 2005 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2488052
28 August 2005 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2503253
27 January 2005 Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2287804
9 March 2004 Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2021235
2 October 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1919643
10 June 2003 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1815940
21 April 2003 Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1777565
5 October 2002 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2009799
29 April 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1636967
20 April 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1607069
8 April 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1602237
23 February 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1488696
18 November 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 771969
17 November 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1076146
20 September 2001 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1074213
11 April 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1068806
5 March 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1059495
5 March 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1405160
12 February 2001 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1440453
10 March 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448074
9 November 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 803298
10 March 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1365103
21 September 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 799519
4 September 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 798611
28 July 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 798062
24 July 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1129862
7 July 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 794013
22 June 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 791860
5 June 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1126202
19 May 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1126219
7 May 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1127728
5 May 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1125291
13 April 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1123298
16 March 1998 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1431931
13 March 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1105398
13 March 1998 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1388437
14 August 1995 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 871805
16 December 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 97083
16 December 1994 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1363240
27 September 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 866559
9 August 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1471316
11 April 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 858980
6 April 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1177079
9 March 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1167868
9 February 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1163644
29 August 1993 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 837857
22 July 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 843241
14 July 1993 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1370657
14 May 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 118456
9 March 1993 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1440677
6 October 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 944002
24 September 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1253467
6 July 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387260
18 November 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1244206
14 November 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1312884
5 November 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 936661
10 October 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 936660
6 August 1991 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 941794
26 July 1991 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1247853
18 July 1991 Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 945598
22 April 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 917783
15 February 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 927777
12 October 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 933139
3 September 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 926980
28 August 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1224213
11 December 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929751
11 September 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1207209
18 November 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1204966
27 September 1988 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1198592
12 May 1988 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1039645
29 March 1988 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1297859
11 March 1988 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 993045
15 February 1988 Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1330605
9 September 1987 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1316658
31 March 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1327207
15 April 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1310870
15 November 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999684
9 October 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301237
29 September 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300608
24 September 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 990091
10 September 1985 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299611
13 February 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 972226
30 January 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 971471
9 September 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1273249
9 September 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1277156
16 May 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1278359
1 December 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 967015
23 September 1982 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 969644
21 May 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963391
9 April 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275854
9 April 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277256
9 March 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271461
9 March 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274730
22 February 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967478

Deficiency record · 274

Engineering › Generator (propulsion/auxiliary-electric) › Switch
Issued 9 March 2004 Resolved
Prove proper operation of emergency generator. LEGACY COMPONENT DESC: Emergency GEN.
Due 7 May 2004
Resolved 27 January 2005
Lifesaving › Lifeboat › Propulsion Engine
Issued 9 March 2004 Resolved
Prove proper operation of #4 life boat.
Due 7 May 2004
Resolved 27 January 2005
Lifesaving › Lifeboat
Issued 21 April 2003 Resolved
Provide repair proposal for #3 starboard life capsule self-righting float assembly, and complete repairs as neccessary.
Due 20 June 2003
Resolved 21 June 2003
Resolution: See ref case.
Construction/Loadline
Issued 11 April 2001 Resolved
PROVIDE COPY OF DIVERS REPORT, VIDEO AND COMPLETE ABS REPORT WITH ANY RECOMMENDATIONS ISSUED AS A RESULT OF FINDINGS OF UNDERWATER EXAM.
Condition: Unknown
Due 11 April 2001
Resolved 11 April 2001
Documentation
Issued 5 March 2001 Resolved
SUBMIT FOR APPROVAL UPDATED FIRE AND SAFETY PLANS.
Condition: Unknown
Due 5 March 2001
Resolved 5 March 2001
Fire Fighting
Issued 5 March 2001 Resolved
Provide servicing report with actual weights of fixed and portable bottles.
Condition: Unknown
Due 11 April 2001
Resolved 9 August 2001
Deck/Cargo
Issued 5 March 2001 Resolved
PROVIDE PROOF OF ANNUAL CRANE EXAM.
Condition: Unknown
Due 11 April 2001
Resolved 9 August 2001
Documentation
Issued 5 March 2001 Resolved
UPDATE MUSTERLIST TO INDICATE APPROPRIATE SECONDARY MUSTER LOCATIONS AND DESIGNATION OF PERSON IN CHARGE OF LIFEBOAT.
Condition: Unknown
Due 11 April 2001
Resolved 9 August 2001
Construction/Loadline
Issued 12 February 2001 Resolved
COMPLETE UNDERWATER PORTION OF LEG TO CAN, CRITICAL WELD CONNECTIONS AT NEXT RIG MOVE. CURRENT LOCATION IS WD71
Condition: Unknown
Due 12 February 2001
Resolved 12 February 2001
Lifesaving
Issued 10 March 2000 Resolved
REPAIR FORWARD ENGINE CONTROL STATION FOR #2 LIFEBOAT.
Condition: Unknown
Due 21 March 2000
Resolved 21 March 2000
Electrical
Issued 16 March 1998 Resolved
PROVIDE CHAFFING GEAR FOR WIRE RUNNING INTO CABLE TRAY IN MUD PIT ROOM.
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Electrical
Issued 16 March 1998 Resolved
REMOVE OR PLACE IN EXPLOSION PROOF JUNCTION BOX ALL DEAD END WIRING ON DRILL FLOOR AND BOP DECK.
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Documentation
Issued 16 March 1998 Resolved
PROVIDE ABS ISSUED LOADLINE/STABILITY LETTER.
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Lifesaving
Issued 16 March 1998 Resolved
LABEL GENERAL ALARM CONTACT SWITCH IN CONTROL HOUSE.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Lifesaving
Issued 16 March 1998 Resolved
PROVIDE SIX MORE DISTRESS FLARES FOR RIG.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Electrical
Issued 16 March 1998 Resolved
COMPLETE INSTALLATION, PROVE ADEQUATE/PURGED FOR HAZARDOUS AREA THE FOLLOWING: IRON ROUGHNECK, DRAWWORKS BLOWER, APPLETON D2P ENCLOSED PANELBOARD, DRILLERS CONSOLE, AND AOI-TOP DRIVE TELEVISION CONSOLE.
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Electrical
Issued 16 March 1998 Resolved
PROVIDE APPROVED WIRE RUN CLIPS FOR OVERHEAD WIRING IN SHALE SHAKER AREA.
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Documentation
Issued 16 March 1998 Resolved
PROVIDE CRANE INSPECTION REPORTS FROM ABS.
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Lifesaving
Issued 16 March 1998 Resolved
ATTACH PORT SIDE OF HELO DECK NETTING TO HELO DECK STANCIONS.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Lifesaving
Issued 16 March 1998 Resolved
SECURE WATER LEAK ON BOTH RELIEF VALVES ON BOTH WATER HEATERS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Electrical
Issued 16 March 1998 Resolved
COMPLETE WIRING CONNECTIONS ON EXHAUST FAN IN SECOND DECK HEAD AND INSTALL COVER.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Lifesaving
Issued 16 March 1998 Resolved
ATTACH CLAMP ON BRACKET ON OVERHEAD PIPING IN DRYSTORES.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Lifesaving
Issued 16 March 1998 Resolved
ATTACH BRACKET FOR STABILIZING WATER HEATER.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Engineering
Issued 16 March 1998 Resolved
INSTALL MISSING VALVE HANDLE TO FUEL FILTER ON #3 GENERATOR.
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Engineering
Issued 16 March 1998 Resolved
INSTALL A VALVE AND REACHROD IN FUEL LINE TO THE EDG.
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Engineering
Issued 16 March 1998 Resolved
INSTALL FLAME SCREEN ON THE EDG FUEL VENT.
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Electrical
Issued 16 March 1998 Resolved
MARK ALL E-LIGHTS, PROVE PROPER OPERATION OF SAME SYSTEM.
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Electrical
Issued 16 March 1998 Resolved
LABEL ALL SWITCHES IN THE ENGINE ROOM
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Construction/Loadline
Issued 16 March 1998 Resolved
MAKE ADJUSTMENTS TO MUD PIT DOORS TO ENSURE SELF CLOSING (GAS TIGHT) AND PROVE PROPER DOG OPERATION.
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Electrical
Issued 16 March 1998 Resolved
PROVE PROPER OPERATION OF MUD PIT VENTILATION SHUTDOWN ALARM.
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Electrical
Issued 16 March 1998 Resolved
COMPLETE INSTALLATION OF GAS DETECTION UNIT IN MUD PITS/SHALE SHAKER AREAS.
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Electrical
Issued 16 March 1998 Resolved
PLACE IN JUNCTION BOX/REMOVE/COMPLETE INSTALLATION OF DEAD-END WIRING UNDERGAITRONICS BOX IN MUD PUMP ROOM.
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Electrical
Issued 16 March 1998 Resolved
LABEL BREAKER IN STORE ROOM BETWEEN RED FOX AND CEMENT ROOM.
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Construction/Loadline
Issued 16 March 1998 Resolved
REPLACE WASTED BILGE PIPING IN CEMENT ROOM, STARBOARD SIDE FORWARD.
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Lifesaving
Issued 16 March 1998 Resolved
PROVE PROPER OPERATION OF EYEWASH STATION IN SHALE SHAKER AREA.
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Electrical
Issued 16 March 1998 Resolved
INSTALL GENERAL ALARM IN SHALE SHAKER AREA.
Condition: Unknown
Due 16 March 1998
Resolved 19 March 1998
Construction/Loadline
Issued 13 March 1998 Resolved
Provide copy of ABS report for all modifications/repairs completed under NVIC 10-82 to [name withheld].
Condition: Unknown
Due 13 March 1998
Resolved 13 March 1998
Construction/Loadline
Issued 13 March 1998 Resolved
Provide copy of ABS report for underwater suvey/spud can inspection to OCMIPort Arthur.
Condition: Unknown
Due 13 March 1998
Resolved 13 March 1998
Documentation
Issued 16 December 1994 Resolved
PROVIDE TO [name withheld], TX. COPIES OF ALL ABS REPORTS OF INSPECTIONS CONDUCTED ON SUBJECT VESSEL RELATED TO CREDIT DRY DOCK AND REPAIRS TO LEGS AND CANS.
Condition: Unknown
Due 23 February 1995
Resolved 5 May 1995
Fire Fighting
Issued 9 August 1994 Resolved
PROVE PROPER OPERATION/FLOW AT FIRE STATION #3.
Condition: Unknown
Due 16 August 1994
Resolved 19 August 1994
Accommodation/Occupational Safety
Issued 9 August 1994 Resolved
OVERHAUL/REPAIR AS NECESSARY AND PROVIDE HANDLES TO ALL QUARTERS VENTILATION DAMPERS.
Condition: Unknown
Due 16 August 1994
Resolved 19 August 1994
Lifesaving
Issued 9 August 1994 Resolved
PROVIDE THE FOLLOWING FOR LIFEBOAT #2: 12 RED PARACHUTE FLARES, REPAIR/REPLACE COMPASS, REFILL BREATHING AIR BOTTLES AS NECESSARY, PROVIDE MONKEY'S FIST FOR HEAVING LINES, ONE ADDITIONAL SEA PAINTER.
Condition: Unknown
Due 16 August 1994
Resolved 19 August 1994
Lifesaving
Issued 9 August 1994 Resolved
PROVIDE THE FOLLOWING FOR LIFEBOAT #3: 340 BAGS OF WATER, MONKEY'S FIST FOR HEAVING LINES, ONE ADDITIONAL SEA PAINTER.
Condition: Unknown
Due 16 August 1994
Resolved 19 August 1994
Lifesaving
Issued 9 August 1994 Resolved
PROVIDE THE FOLLOWING FOR LIFEBOAT #4: MONKEY'S FIST FOR HEAVING LINES, ONE ADDITIONAL SEA PAINTER.
Condition: Unknown
Due 16 August 1994
Resolved 19 August 1994
Lifesaving
Issued 9 August 1994 Resolved
PROVIDE SIX ADDITIONAL RED PARACHUTE FLARES FOR UNIT.
Condition: Unknown
Due 16 August 1994
Resolved 19 August 1994
Lifesaving
Issued 9 August 1994 Resolved
PROVIDE EMERGENCY LIGHTING TO ALL LIFEBOAT EMBARKATION AREAS TO ILLUMINATE EMBARKATION AREA AND WATER AT LAUNCHING AREA.
Condition: Unknown
Due 9 August 1994
Resolved 9 August 1994
Lifesaving
Issued 9 August 1994 Resolved
PROVIDE THE FOLLOWING FOR LIFEBOAT #1: 23 BAGS OF WATER, MONKEY'S FIST FORHEAVING LINES, ONE ADDITIONAL SEA PAINTER.
Condition: Unknown
Due 16 August 1994
Resolved 19 August 1994
Construction/Loadline
Issued 6 April 1994 Resolved
EFFECT PERMANENT REPAIRS TO INDICATIONS FOUND ALONG LEG TO SPUD CAN CONNECTIONS AS NOTED IN DIVERS REPORT DATED 19-25 AUG 93 AND ABS REPORT DATED 24 AUG 93 NO LATER THAN NEXT DRYDOCKING.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Construction/Loadline
Issued 9 March 1994 Resolved
EFFECT PERMENANT REPAIRS IN WAY OF INDICATIONS FOUND ALONG THE LEG TO CAN CRITICAL CONNECTIONS AS NOTED ON DIVERS REPORT DATED 19-25 AUG 94 AND ABS REPORT DATED 24 AUG 94. INDICATIONS DISCOVERED AT UNITS LAST SEILOD. REPAIRS TO BE MADE AT NEXT RIG MOVE BUT NOT LATER THAN 31JUL94.
Condition: Unknown
Due 9 March 1994
Resolved 9 March 1994
Engineering
Issued 14 July 1993 Resolved
MAKE PERMENANT REPAIRS TO MAIN ENG COOLING (RAW WATER) PIPING, FEED AND DISCHARGE IN WAY OF ENG ROOM AND CEMENT MIXING ROOM.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Electrical
Issued 14 July 1993 Resolved
MAKE PERMENANT REPAIRS TO ALL BROKEN WIRE SUPPORT BRACKETS ON THE OVERHEAD IN THE MUD PIT ROOM.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Engineering
Issued 14 July 1993 Resolved
PROVIDE AN ADEQUATE TRANSFER PROCEDURE PER 33CFR155.720 AND CONTAIN AS INDICATED IN 155.750.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Engineering
Issued 14 July 1993 Resolved
PROVIDE DISCHARGE OF OIL PROHIBITED PLACARD AS SPECIFIED IN 33CFR155.450.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Unknown
Issued 14 July 1993 Resolved
MAKE READY FOR INTERNAL EXAMINATION ALL P-TANKS FOR CREDIT EXAM.
Condition: Unknown
Due 14 July 1993
Resolved 14 July 1993
Construction/Loadline
Issued 9 March 1993 Resolved
COMPLETE PHASE TWO OF DIAMOND-M ODECO SEILOD PREPOSAL AS PER LETTER DATED 13JAN93. IN ADDITION DRILL WATER TANKS #3 P, S & C MUST BE OPENED, GAS FREEAND MADE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 9 March 1993
Resolved 9 March 1993
Construction/Loadline
Issued 24 September 1992 Resolved
REPLACE BILGE SUCTION LINE IN STBD. P-TANK ROOM.
Condition: Unknown
Due 24 September 1992
Resolved 24 September 1992
Electrical
Issued 6 July 1992 Resolved
REPAIR ALL BUNK LIGHTS IN ACCOMODATION SPACES AND OVERHEAD LIGHTS.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Deck/Cargo
Issued 6 July 1992 Resolved
MAKE PERMANENT REPAIRS TO ALL LEAKING PIPES IN STBD. P-TANK ROOM.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Fire Fighting
Issued 6 July 1992 Resolved
REPAIR THE FOLLOWING GENERAL ALARM BELLS; (1) FRONT OF HOUSE BY FIRE STA. NO. 10 (2) DRILL FLOOR (3) MECHANICS ROOM (4) ABOVE WTD NO. 9 (5) MUD PUMP ROOM (6) CEMENT ROOM.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Electrical
Issued 6 July 1992 Resolved
PROPERLY PURGE ELECTRICAL ROOM (DOG HOUSE) ON DRILL FLOOR.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Electrical
Issued 6 July 1992 Resolved
REPAIR PURGE INDICATOR TO STROKE COUNTER LOCATED BEHIND DRILLERS CONSOLE.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Fire Fighting
Issued 6 July 1992 Resolved
REPAIR FIRE HYDRANTS NO. 7 AND 8.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Documentation
Issued 6 July 1992 Resolved
SUBMIT REVISED OPERATIONS MANUAL TO COAST GUARD.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Engineering
Issued 6 July 1992 Resolved
REPAIR LOW LUBE OIL ALARM TO SSDG NO. 1.
Condition: Unknown
Due 6 July 1992
Resolved 6 July 1992
Documentation
Issued 5 November 1991 Resolved
MAKE REVISION TO FIRE CONTROL AND LIFE SAVING PLAN AS REQUIRED BY MSO PORT ARTHUR LTR OF 05NOV91.
Condition: Unknown
Due 5 November 1991
Resolved 5 November 1991
Documentation
Issued 26 July 1991 Resolved
PROVIDE PROOF OF DOCUMENTATION
Condition: Unknown
Due 26 August 1991
Resolved 16 December 1991
Electrical
Issued 26 July 1991 Resolved
PROVE PROPER OPERATION OF PURGED AND PRESSURIZED ROOM ON DRILL FLOOR.
Condition: Unknown
Due 16 December 1991
Resolved 16 December 1991
Construction/Loadline
Issued 26 July 1991 Resolved
REWELD OVERHEAD LONGITUDINALS ON BOTH PORT AND STBD SIDES OF MUD PIT ROOM.
Condition: Unknown
Due 16 December 1991
Resolved 16 December 1991
Lifesaving
Issued 26 July 1991 Resolved
PROVE PROPER OPERATION OF LIFEBOAT NO. 2 DAVIT WINCH AND LIMIT SWITCH.
Condition: Unknown
Due 16 December 1991
Resolved 16 December 1991
Electrical
Issued 26 July 1991 Resolved
PROVE PROPER OPERATION OF RVERSE POWER RELAYS FOR # 2 AND 3 GENERATORS.
Condition: Unknown
Due 16 December 1991
Resolved 16 December 1991
Electrical
Issued 26 July 1991 Resolved
REPOSITION PERIMETER LIGHTING TO MAXIMUM OF 10 FT. DISTANCE BETWEEN LIGHTS.
Condition: Unknown
Due 26 July 1991
Resolved 26 July 1991
Construction/Loadline
Issued 12 October 1990 Resolved
CUT OUT AND REPLACE THE #5 PORT PRELOAD TANK MAIN DECK MAN HOLE DUE TO WASTAGE.
Condition: Unknown
Due 12 October 1990
Resolved 12 October 1990
Construction/Loadline
Issued 3 September 1990 Resolved
COMPLETE INTERNAL EXAMINATION OF PRELOAD, BALLAST, AND VOIDS INCLUDING SEA VALVES AND REPRESENTATIVE PRELOAD DUMP/CHECK VALVES, BY AN ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 3 September 1990
Resolved 3 September 1990
Construction/Loadline
Issued 3 September 1990 Resolved
REPLACE WARPED FIRE DOOR STARBOARD 02 LEVEL BY TOOL PUSHER'S.
Condition: Unknown
Due 3 September 1990
Resolved 3 September 1990
Construction/Loadline
Issued 3 September 1990 Resolved
SUBMIT REPAIR PROPOSAL TO [name withheld] FOR ALL FRACTURES TO CHORD CONNECTIONS DETECTED DURING 02/03 SEPTEMBER 90 SPECIAL EXAM IN LIEU OF DRYDOCK.
Condition: Unknown
Due 3 September 1990
Resolved 3 September 1990
Fire Fighting
Issued 28 August 1990 Resolved
SERVICE BV DRY CHEMICLE FIRE EXTINGUISHER LOCATED ON DRILL FLOOR.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Documentation
Issued 28 August 1990 Resolved
RENEW CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Documentation
Issued 28 August 1990 Resolved
RESUBMIT CONSTRUCTION PORTFOLIO ENSURING THAT PROPER WELD PROCEDURES ARE COVERED FOR SSS 100 AND LOCATIONS OF ALL STEEL SPECIFIC WELD PROCEDURES AREINCLUDED.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Electrical
Issued 28 August 1990 Resolved
PROVIDE EXPLOSION PROOF SWITCH BOX OR PURGE IAW NFPA 496 THE TOTCO SWITCH BOX LOCATED ABOVE MARTIN DECKER CONSOLE ON DRILL FLOOR.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Electrical
Issued 28 August 1990 Resolved
PROVED EXPLOSION PROOF SWITCH BOX OR PURGE IAW NFPA 496 THE CAMERON IRON WORKS STROKE COUNTER LOCATED AFT OF DRILLER'S CONSOLE ON DRILL FLOOR.
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Fire Fighting
Issued 28 August 1990 Resolved
SERVICE PORTABLE, SEMI-PORTABLE, AND FIXED FIRE EXTINGUISHERS AS INDICATED ON SAFETY AND HEALTH ASSOCIATES INSPECTION REPORT DATED 20 JULY 1990. PRO-VIDE DOCUMENTATION SHOWING COMPLETION .
Condition: Unknown
Due 28 August 1990
Resolved 28 August 1990
Deck/Cargo
Issued 11 December 1989 Resolved
THE TWO NATIONAL CRANES ARE NOT TO BE USED UNTILL ALL BOOM PARTS ARE EITHER REPLACED OR SAND BLASTED AND MAGNIFLUXES A-FRAME PORT CRANE WASTED IN PLACES,BROKEN WELDS AS WELL. FULL LOAD TEAT REQUIRED AFTER REPAIRS.
Condition: Unknown
Due 11 December 1989
Resolved 11 December 1989
Electrical
Issued 11 December 1989 Resolved
REPAIR THE WASTED DECK ELECTRICAL PENETRATION (KICK PIPES) IN THE DOR HOUSE ON THE DRILL FLOOR.
Condition: Unknown
Due 11 December 1989
Resolved 11 December 1989
Electrical
Issued 11 December 1989 Resolved
POUR THE EYS AND STRIP BACK THE CABLE ABOVE THE UPPER SHALE SHAKER FOR THE GAS DETCTOR.
Condition: Unknown
Due 11 December 1989
Resolved 11 December 1989
Electrical
Issued 11 December 1989 Resolved
RENEW THE BATTERY CABLE CONNECTORS FOR THE OBSTRUCTION LIGHTS BATTERIES WITH PROPER CONNECTION.
Condition: Unknown
Due 11 December 1989
Resolved 11 December 1989
Construction/Loadline
Issued 11 December 1989 Resolved
REPAIR THE HOSE IN THE WATER TIGHT BULKHEAD AT THE DECK BETWEEN WATER TIGHT DOOR #15 AN THE BATTERY BOXES.
Condition: Unknown
Due 11 December 1989
Resolved 11 December 1989
Fire Fighting
Issued 11 December 1989 Resolved
REPAIR THE #1 FIRE PUMP.
Condition: Unknown
Due 11 December 1989
Resolved 11 December 1989
Electrical
Issued 11 December 1989 Resolved
RENEW THE HOUSE HOLD RECEPTICLE BELOW THE LIGHT AT THE WELDING MECHINE BY THE HALLIBURTON ROOM.
Condition: Unknown
Due 11 December 1989
Resolved 11 December 1989
Electrical
Issued 11 December 1989 Resolved
RENEW THE TYPE SO CABLE ON THE LIGHT IN THE ENGINROOM BETWEEN THE SCR ROOM AND WATER TIGHT DOOR #7 WITH APPROVED CABLE.
Condition: Unknown
Due 11 December 1989
Resolved 11 December 1989
Electrical
Issued 11 December 1989 Resolved
RENEW THE TYPE SO CABLE COMING FROM THE TOP OF THE 450V DISTRIBUTION PANEL IN THE ENGIN WITH APPROVED CABLE (PROPER).
Condition: Unknown
Due 11 December 1989
Resolved 11 December 1989
Electrical
Issued 11 September 1989 Resolved
POUR EYS ON EXPLOSION PROOF SWITCH BOX FOR TOP DRIVE UNIT LOCATED BEHIND PANEL ADJACTENT TO DRILLERS CONSOLE.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
PROVIDE PURGE SYSTEM AND AUDIBLE PURGE SYSTEM ALARM IN ACCORDANCE WITH NFPA496 FOR DOG HOSE LOCATED ON DRILL FLORE
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Construction/Loadline
Issued 11 September 1989 Resolved
RENEW SECTION OF HYDRAULIC ON STBD JACKING HOUSE ADJACENT TO STBD AFT CRANE
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Documentation
Issued 11 September 1989 Resolved
RESUBMIT CONSTRUCTION PORTFOLIO ENSURE THAT PROPER WELD PROCEDURES FOR SSS100 AND LOCATION OF ALL STEEL REQUIRING SPECIFIC WELD PROCEDURES ARE INCLUDED
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Deck/Cargo
Issued 11 September 1989 Resolved
HYDROSTATICALY TEST AND REFILL OXYGEN BOTTLES ON RESUCITATOR
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
REPAIR RENEW AS NEEDED THE WIRES ENTERING THE FOG HORN BATTERY BOX LOCATED ON THE PORT SIDE NEAR THE JACKING HOUSE
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Lifesaving
Issued 11 September 1989 Resolved
RENEW MAIN COG IN #4 LIFE CAPSULE MANUAL RETRIEVAL UNIT.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Lifesaving
Issued 11 September 1989 Resolved
LIFE CAPSULES 4&3 ARE TO BE WEIGHT TESTED TO 1.5 AFTER REBUILDING AND REFURBISHING. TEST TO BE DONE TO THE SATISFACTION OF THE COGNISANT OCMI.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
MARK ALL GENERAL ALARMS AND LIGHTS IN ENGIN ROOM WHEN BELL RINGS OR LIGHT FLASHES GO TO YOUR STATION.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
REMOVE DEAD END WIRE FROM AFT MUD PIT BULKHEAD PENERTRATION
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
POUR EYS ON #1 #2 MUD PIT AGITATOR MOTOR. ENSURE SHEATH IS REMOVED DOWN TO THE CONDUCTORS PRIOR TO POURING LOCATED MUD PIT
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
POUR EYS ON LIGHT ABOVE #2AGITATOR AND BOTH GAS DECTORS UNITS IN MUD PITS.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
POUR EYS ON LOUDSPEAKER DRIVER UNIT LOCATED IN MUD PITS.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
REFASTEN EYS AND POUR ON LIGHT ABOVE AGITATOR #3
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
LABEL ALL SWITCHES IN THE MUD PIT WITH SYSTEM SERVED.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
STENCEL GENERAL IN THE MUD PITS GENERAL ALARM RINGS GO TO YOUR STATION
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
RENEW ONE HELO DECK(LIGHT PRESENTLY YELLOW LIGHTS) WITH BLUE LENSE CREATINGALT COLORS.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Documentation
Issued 11 September 1989 Resolved
PROVE COAST GUARD APPROVED OF THE FIRE CONTROL PLAN OR SUBMIT TO THE OCMI FOR APPROVAL
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Fire Fighting
Issued 11 September 1989 Resolved
REPLACE PRESSURE GAUGE ON FIRE PUMP #1
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Fire Fighting
Issued 11 September 1989 Resolved
REPLACE PACKING ON FIRE PUMP #2
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Fire Fighting
Issued 11 September 1989 Resolved
MAKE OPERABLE FROZEN INLET VALVE ON FIRE PUMP #1
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Fire Fighting
Issued 11 September 1989 Resolved
FREE UP ALL VALVES ON FIRE MAIN BILGES PUMP MANAFOLD AND MARK EACH VALVE FOR SYSTEM SERVED.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Accommodation/Occupational Safety
Issued 11 September 1989 Resolved
REMOVE FROM SERVICE PERSONNEL "BILLY PUGH" BASKET LOCATED ON MAIN DECK AFT OF DECK HOUSE.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
LABEL BREAKER ON MAIN BOARD FOR SYSTEM SERVED(I.E. MAIN 600V BP)
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Fire Fighting
Issued 11 September 1989 Resolved
REFASTEN HAND WHEEL ON SALT WATER SERVICE PUMP 32 INLET.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Fire Fighting
Issued 11 September 1989 Resolved
REPLACE 2 MISSING BOLTS ON CONNECTING FLANGE FOR SALT WATER SERVICE LINE LOCATED IN VICINITY OF SEA CHEST.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
STENCEL GENERAL ALARM WHEN BELL RINGS GO TO YOUR STATION NEAR GENERAL ALARM BELL IN SACK ROOM.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
REPAIR RAW WATER VALVE LEAKING ON MANIFLOD FOR #2 EMD. CK MANIFOLD FOR EXCESS WASTAGE WHERE LEAKING HAS OCCURED.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
RE-STENCEL NEAR GERENAL ALARM BELL IN HALIBURTON ROOM GENERAL ALARM WHEN BELL RINGS GO TO YOUR STATION.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
REPAIR LEAKING SALT WATER COOLING SHUT OFF VALVE LOCATED ON RISER FOR #1 EMD. CHECK RISER WHERE WATER HAS BEEN LEAKING FOR EXCESS WASTAGE.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Fire Fighting
Issued 11 September 1989 Resolved
REPLACE 18" WASTED SECTION OF FIRE MAIN DISCHARGE FOR #2 FIRE PUMP CRACK EXISTING IN CURRENT SECTION. TESTAFTER COMPLETION OF REPAIRS TO CAPACITY OFBOTH PUMPS OPERATING SIMULTANEOUSLY.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
REPLACE PLASTIC TIE WRAPS IN HORIZONTAL CABLE RUNS LOCATED IN OVERHEAD BY NUMBER 3 JACKING TOWER. WITH 5/8 DIAMETER NON-CORROSIVE METAL BANDS
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
POUR EYS FITTING ON EASY TORQUE EXPLOSION PROOF SWITCH BOX LOCATED ON DRILLERS CONSOLE
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Construction/Loadline
Issued 11 September 1989 Resolved
REPAIR DOGS AND HATCH ON SACK ROOM AS NEEDED TO ENSURE WATER TIGHTNESS.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Accommodation/Occupational Safety
Issued 11 September 1989 Resolved
RENEW NON-SKID ON HELO DECK.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Lifesaving
Issued 11 September 1989 Resolved
WT TEST ALL LIFE BOATS AND CAPSULES IN THE PRESENCE OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Documentation
Issued 11 September 1989 Resolved
RESUBMIT HAZARDOUS ZONE DRAWING TO COGNIZANT OCMI FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Documentation
Issued 11 September 1989 Resolved
ENSURE CERTIFICATE OF DOCUMENTATION IS MAINTAINED ON BOARD, SEND COPY OF SAM TO OCMI.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Deck/Cargo
Issued 11 September 1989 Resolved
FNNUAL AND QUADRENIAL TEST TO BE DONE ON PORT AND STARBOARD CRANS SER #111 AND 110.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Lifesaving
Issued 11 September 1989 Resolved
CHANGE ALL FUEL IN ALL LIFE BOATS.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Fire Fighting
Issued 11 September 1989 Resolved
RENEW 11/2 50 FIRE HOSE IN THE HALIBURTON ROOM WITH A 21/2 50 HOSE AS REQUIRED BY FIRE PLAN.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Lifesaving
Issued 11 September 1989 Resolved
HYDROSTATICALLY TEST ALL AIR BOTTLES IN #1 AND #2 50 MAN LIFE CAPSULES.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
REPLACE GENERAL ALARM BELL BY MUD PIT VENT MAIN DECK WITH AN APPROVED TYPE FOR CLASS I DIV II AND OR RELOCATE OUTSIDE OF HARAROUS ZONE.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
PROVIDE FOR INSPECTION SHUT DOWN AND ALARMS FOR ALL THREE EMDS. OVERSPEED. LOW LUBE OIL HIGH CRANK CASE PRESSURE AND HIGH TEMP ALARMS.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Construction/Loadline
Issued 11 September 1989 Resolved
CROP AND RENEW WASTE MAIN DECK AREA SURROUNDING WIRE WAY LEADING INTO OVERHEAD OF SACK ROOM WATER IS LEAKING FROM MAIN DECK INTO SACK ROOM.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
REPAIR ALARM RESET IN #2 EMD ANNUNCIATOR PANEL.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
REPLACE PACKING ON HAND FUEL PRIMING PUMP FOR #3 EMD (PUMP IS LEAKING FUEL)
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
MAKE OPERABLE BATTERY PROVIDE 6V E [name withheld] ROOM.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Lifesaving
Issued 11 September 1989 Resolved
RENEW REPAIR AS NEEDED #3 LIFE BOAT WINCH DRUM PILLOW BLOCK SUPPORTS AND FOUNDATION BOLTS VESSEL TO BE LIMITED TO 50 PERSON UNTIL COMPLETED
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
POUR EYS ON LIGHT ABOVE DE-SILTER UNIT IN LOWER SHALE SHAKER AREA.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
ADD EYS AND POUR TO FORWARD UPPER SHALE SHAKER LUBRICATION UNIT. REMOVE SHEATHING DOWN TO CONDUCTOR PRIOR TO POURING.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
REPAIR MICRO SWITCH ALARM FOR EXHAUST FAN FOR MUD PITS, ADD LOSS OF VENTILATION ALARMS FOR BOTH INLETS SUPPLY FANS.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Lifesaving
Issued 11 September 1989 Resolved
REAJUST PACKING GLAND IN STUFFING BOX REQUIRED ON #2 LIFE BOAT STARB.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Lifesaving
Issued 11 September 1989 Resolved
ENSURE ALL EQUIPMENT REQUIRED BY EQUIPMENT LIST FOR LIFE BOATS IS ON BOARD ALL LIFE BOATS.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Construction/Loadline
Issued 11 September 1989 Resolved
SEAL ALL BULKHEAD PENETRATIONS IN MUD PITS.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
LOCATE AND REPAIR SOURCE OF GROUND TO EMERGENCY CIRCUIT A BUS.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
REPLACE CRACKED INSULATORS ON T1 AND T2 POWER UNITS ON 600V BUS LOCATED IN SCR ROOM.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
REFASTEN EXPLOSION PROOF SWITCH BOX LOCATED ABOVE #3 MUD PIT AGITATORS
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
CHECK ALL BATTERY POWERED RELAY ACTIVATED EMERGENCY LIGHTING ON THE RIG FORPROPER OPERATION.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
REPLACE FOUR EACH ON EXPLOSION PROOF RECEPTACLE BOXES WITH EXPLOSION PROOF TYPE ADD SEALED FITTINGS LOCATED STBD SIDE DRILL FLOOR OVERHEAD.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
POUR ALL 6 EYS FITTINGS ON 3 EA BUG BLOWER EXPLOSION PROOF SWITCH BOXES. LABEL ALL SWITCH BOXES ON DRILL FLOOR
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
POUR EYS FITTINGON BOP ACCUMULLATOR DRIVE MOTOR LOCATED RIG FLOOR STBD SIDE
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Construction/Loadline
Issued 11 September 1989 Resolved
REPAIR WASTED HANGERS ON PORT SIDE BENEATH DRILL FLOOR POUR EYS FITTING ON BREAKE COOLING PUMPS BENEATH DRILL FLOOR
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
REPAIR SOLENOID OR STARTING PROBLEM WITH EMERGENCY GENERATOR.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
LABLE LOSS OF VENTILATION ALARM HORN MUD PITS LOSS OF VENTILATION.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
PROVIDE TEST OF VENTILATION SHUT DOWN FOR ENGINEERING SPACES AND LIVING SPACES.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
POUR EYS FITTINGS ON DE-SANDER, MUD CLEANER AND DEGASSER CIRCULATION PUMPS.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
POUR EYS ON EXPLOSION PROOF RECEPTACLE BOX LOCATED LOWER SHAKER AREA
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Lifesaving
Issued 11 September 1989 Resolved
ENSURE PROPER HOME PORT AND MAWS ARE PAINTED ON LIFE BOATES AND RIG HULL.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Construction/Loadline
Issued 11 September 1989 Resolved
REPLACE WASTED HANGERS ON HYDRAULIC PIPING LOCATED ON DRILL FLOOR SUBSTRUCTURE.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
MAKE OPERABLE EMERGENCY LIGHTING IN EMERGENCY GENERATOR SPACE
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Lifesaving
Issued 11 September 1989 Resolved
RENEW CABLE ON #3 AND #4 LIFE BOATS, VESSEL TO BE LIMITED TO 50 PERSONS UNTIL COMPLETED.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Lifesaving
Issued 11 September 1989 Resolved
RESEAL CRACKS AND CHIPED GELL CAOT AS NEEDED ON ALL LIFE BOATS.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
REMOVE DEAD END WIRING ABOVE FORWARD UPPER SHALE SHAKER UNIT.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
POUR EYS FITTING ON LIGHT ABOVE UPPER/AFTER SHALE SHAKER. ENSURE SHEATHING IS REMOVED PRIOR TO POURING DOWN TO THE CONDUCTOR.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
REPLACE EXPLOSION PROOF ARMOURED FLEXIBLE WHIPS ON BOTH UPPER SHALE SHAKER UNITS.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
REMOVE SILICONE AND PAK WITH CORRECT MATERIAL EYES ON GENERAL ALARM IN MUDPITS (INSURE SHEATHING IS REMOVED DOWN TO THE CONDUCTORS PRIOR TO POURING).
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Documentation
Issued 11 September 1989 Resolved
PROVIDE DOCUMENTATION AND TEST OF ALL GAS DETECTORS ON RIG.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Deck/Cargo
Issued 11 September 1989 Resolved
PROVIDE NEGATIVE PRESSURE FOR MUD PITS.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 11 September 1989 Resolved
REPLACE NON-EXPLOSION LIGHT WITH EXPLOSION PROOF TYPE FOR CLASS I DIV. II AREA LOCATED ABOVE MUD WEIGH STATION BY ACCESS DOOR TO MUD PITS.
Condition: Unknown
Due 11 September 1989
Resolved 11 September 1989
Electrical
Issued 27 September 1988 Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIP AND REVERSE CURRENT RELAY ON GENERATORS 1, 2, AND 3 AT END OF PRESENT DRILLING OPERATIONS.
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Electrical
Issued 27 September 1988 Resolved
PROPERLY STUFF APPROXIMATELY 15 WIRES ENTERING BOTTOM OF 110 VOLT BREAKER PANEL IN "DOG HOUSE".
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Electrical
Issued 27 September 1988 Resolved
REPAIR EMERGENCY LIGHT AT WATERTIGHT DOOR NUMBER 7.
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Lifesaving
Issued 27 September 1988 Resolved
GENERAL ALARM SWITCHES MISSING GLASS PANEL ON FRONT I DOG HOUSE. PROVIDE PROPER GLASS COVER AND HAMMER.
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Electrical
Issued 27 September 1988 Resolved
PROVIDE ELECTRICAL MATTING FOR EMERGENCY GENERATOR SWITCHBOARD.
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Unknown
Issued 11 March 1988 Resolved
REMOVE AND REPAIR THE NO.2 WHITAKER LIFESAVING CAPSULE PRIOR TO LEAVING THE PORT OF PASCAGOULA, MS. THE OCMI MOBILE AL IS TO BE NTFD PRIOR TO LEAVING PASCAGOULA, MS OF THE SATIFACTION OF THIS REQUIREMENT.
Condition: Unknown
Due 11 March 1988
Resolved 11 March 1988
Unknown
Issued 11 March 1988 Resolved
ALL OTHER DAMAGE THAT OCCURED AS A RESULT OF THE COLLISION ON 15FEB88 IS TO BE REPAIR TO THE SATISFACTION OF THE [name withheld] PRIOR TO LEAVING PASCAGOULA MS.
Condition: Unknown
Due 11 March 1988
Resolved 11 March 1988
Lifesaving
Issued 15 February 1988 Resolved
REMOVE AND REPAIR THE NO.2 WHITAKER LIFESAVING CAPSULE PRIOR TO LEAVING THEPORT OF PASCAGUOLA, MS. OF THE SATISFACTION OF THIS REQUIREMENT.
Condition: Unknown
Due 15 February 1988
Resolved 15 February 1988
Construction/Loadline
Issued 15 February 1988 Resolved
ALL OTHER DAMAGE THAT OCCURRED AS A RESULT OF COLLUSION ON 15FEB88 IS TO BE REPAIRED TO THE SATISFACTION OF THE [name withheld] PRIOR TO LEAVING PASCAGUOLA, MS.
Condition: Unknown
Due 15 February 1988
Resolved 15 February 1988
Documentation
Issued 9 September 1987 Resolved
PROVIDE COPY OF MSD CERTIFICATION LETTER
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Lifesaving
Issued 9 September 1987 Resolved
PROVIDE 12 HH ROCKET PARACHUTE FLARES FOR BRIDGE.
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Fire Fighting
Issued 9 September 1987 Resolved
PROVIDE PROPER OPERATIONS OF H2S AUDIBLE SIREN IN AIR COMPRESSOR ROOM.
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Construction/Loadline
Issued 9 September 1987 Resolved
REPLACE FOLLOWING PANES OF BROKEN GLASS: A) LOWER PANE-STARBOARD CRANE AFT B) PILOT HOUSE-2 PANES
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Navigation
Issued 9 September 1987 Resolved
PROVIDE PROPER OPERATIONS OF STERN LIGHT
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Construction/Loadline
Issued 9 September 1987 Resolved
UNDERGO A FULL CREDIT DRYDOCKING PERIOD OR SPECIAL EXAM IN LIEU OF DRYDOCKING.
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Construction/Loadline
Issued 9 September 1987 Resolved
AT TIME OF DRYDOCKING, PROVIDE MARINE CHEMIST "SAFE FOR WORKERS" CERTIFICATION FOR ALL INTERNAL BALLAST, PRE-LOAD AND DRILL WATER TANKS AND VOID SPACES.
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Accommodation/Occupational Safety
Issued 9 September 1987 Resolved
OPEN AND MAKE AVAILABLE FOR INTERNAL EXAMINATION ALL (9) LISTED PRESSURE VESSELS.
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Lifesaving
Issued 9 September 1987 Resolved
RE-GASKET ALL DOOR AND HATCH SEALS TO BOTH MLB'S AND PROVE WATER TIGHTNESS OF SAME.
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Fire Fighting
Issued 9 September 1987 Resolved
PROVIDE HINGES VENT CLOSURE DEVICE FOR PAINT LOCKER GOOSE NECK VENT.
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Fire Fighting
Issued 9 September 1987 Resolved
POST SIGN IN VICINITY OF PAINT LOCKER CO2 PULLS -STATING- "CLOSE VENT PRIORTO ACTIVATING CO2 BOTTLE".
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Lifesaving
Issued 9 September 1987 Resolved
REGARDING GENERAL ALARM SYSTEM, PROVE PROPER OPERATIONS OF: A) BOW MAIN DECK-BELL B) SACK STOREROOM-PORTSIDE-BELL C) GENERAL ROOM-ROTATING BEACON D) MUD PIT ROOM-BELL
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Accommodation/Occupational Safety
Issued 9 September 1987 Resolved
PROVE PROPER OPERATION OF ALL (9) PRESSURE VESSEL RELIEF VALVES.
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Lifesaving
Issued 9 September 1987 Resolved
REGARDING #1 MLB: A) PROVIDE 12 HH RED FLARES. B) PROVIDE 1177 OZ. OF WATER. C) PROVIDE CONTAINER FOR TOOL KIT.
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Lifesaving
Issued 9 September 1987 Resolved
REGERDING #2 MLB: A) PROVIDE 12 HH RED FLARES. B) PROVIDE 1173 OZ. OF WATER.
Condition: Unknown
Due 9 September 1987
Resolved 9 September 1987
Electrical
Issued 15 April 1986 Resolved
MAKE NECESSARY REPAIRS TO GROUND DETECTION SYSTEM ON THE 120 VAC 3 PHASE DISTRIBUTION PANEL IN ENGINE ROOM. MAKE REPAIRS TO CIRCUITS WITHIN THIS SAME DISTRIBUTION PANEL TO REMOVE THE APPROXIMATE 40 VOLTS TO GROUND AS MEASURED BETWEEN EACH PHASE AND GROUND.
Condition: Unknown
Due 15 April 1986
Resolved 15 April 1986
Construction/Loadline
Issued 10 September 1985 Resolved
MAKE AVAILABLE FOR INSPECTION THE #4 PORT TANK DUMP VALVE. NVC4-78.
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985
Accommodation/Occupational Safety
Issued 10 September 1985 Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION THE DRILL FOOR AIR RECEIVER. NVC 4/78
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985
Accommodation/Occupational Safety
Issued 10 September 1985 Resolved
TEST IN THE PRESENCE OF A COAST GUARD INSPECTOR THE DRILL FLOOR AIR RECEIVER RELIEF VALVE. NVC 4-78
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985
Electrical
Issued 10 September 1985 Resolved
CONDUCT AN OPERATIONAL TEST OF THE THREE DIESEL GENERATOR SETS NVC4-78.
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985
Construction/Loadline
Issued 10 September 1985 Resolved
CONDUCT AN UNDERWATER VIDEO INSPECTION IN ACCORDANCE WITH YOUR COAST GUARD APPROVED DRYDOCKING PROPOSAL. NVC4-78.
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985
Lifesaving
Issued 23 September 1982 Resolved
PROVIDE THE FOLLOWING PYROTECHNICS ON BOARD THE UNIT:(1)PARACHUTE FLARE FORTHE MODU;(12)PARACHUTE FLARES IN EACH LIFEFLOAT;(2)ORANGE SMOKE SIGNALS
Condition: Unknown
Due 23 September 1982
Resolved 23 September 1982
Navigation
Issued 23 September 1982 Resolved
COMPLETE PERMANENT REPAIRS TO MAKE THE BOW OBSTRUCTION LIGHT OPERATIONAL
Condition: Unknown
Due 23 September 1982
Resolved 23 September 1982
Electrical
Issued 23 September 1982 Resolved
RENEW SPLICED WIRING IN THE DRILLERS CONSOLE.
Condition: Unknown
Due 23 September 1982
Resolved 23 September 1982
Construction/Loadline
Issued 23 September 1982 Resolved
RENEW DETERIORATED BRACKETS FOR HELIPORT NETTING
Condition: Unknown
Due 23 September 1982
Resolved 23 September 1982
Electrical
Issued 23 September 1982 Resolved
RENEW SHORTED ELECTRICAL CABLES FOR HELIPORT LIGHTING.
Condition: Unknown
Due 23 September 1982
Resolved 23 September 1982
Navigation
Issued 23 September 1982 Resolved
RENEW WHITE LIGHT ON NAVIGATION LIGHT MAST IN RED-WHITE-RED SEQUENCE WITH AN ALL AROUND LIGHT.
Condition: Unknown
Due 23 September 1982
Resolved 23 September 1982
Deck/Cargo
Issued 23 September 1982 Resolved
CONDUCT TESTS OF ALL AIR PURGE AIR PRESSURE LOSS ALARMS
Condition: Unknown
Due 23 September 1982
Resolved 23 September 1982
Electrical
Issued 23 September 1982 Resolved
PROVIDE PROOF A/B JUNCTION BOX IN SHALE SHAKER AREA IS UL OR FM LISTED FOR CLASSIFIED LOCATIONS OR PROVIDE SUITABLE AIR PURGING FOR THE BOX.
Condition: Unknown
Due 23 September 1982
Resolved 23 September 1982
Documentation
Issued 23 September 1982 Resolved
COMPLETE SPECIAL EXAMINATION IN LIEU OF DRYDOCKING FOR CREDIT DRYDOCK.
Condition: Unknown
Due 23 September 1982
Resolved 23 September 1982
Engineering
Issued 23 September 1982 Resolved
CONDUCT HYDROSTATIC INSPECTION OR INTERNAL EXAMINATION OF THE VESSELS AIR RECIEVERS.
Condition: Unknown
Due 23 September 1982
Resolved 23 September 1982
Electrical
Issued 23 September 1982 Resolved
CONDUCT GENERATOR TESTS FOR SERVICE AND EMERGENCY GENERATORS - OVERSPEED, ALARM, REVERSE POWER RELAY.
Condition: Unknown
Due 23 September 1982
Resolved 23 September 1982
System not recorded
Issued 23 September 1982 Resolved
EFFECT REPAIRS TO FIREMAIN TO MAKE FIRE STATION #16 OPERABLE. REPAIRED SECTION SHALL BE HYDROSTACTLY TESTED TO SATISFACTION OF MARINE INSPECTOR.
Condition: Unknown
Due 1 December 1982
Resolved 8 April 2002
Documentation
Issued 23 September 1982 Resolved
PROVIDE ONBOARD THE VESSEL A COAST GUARD APPROVED OPERATIONS MANUAL.
Condition: Unknown
Due 23 September 1982
Resolved 23 September 1982
Electrical
Issued 23 September 1982 Resolved
PROVIDE UL OR FM LISTED EXPLOSION PROOF LIGHTS FOR THE SCHLUMBARGER UNIT.
Condition: Unknown
Due 23 September 1982
Resolved 23 September 1982
Documentation
Issued 23 September 1982 Resolved
PROVIDE ONBOARD THE VESSEL AN APPROVED CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 23 September 1982
Resolved 23 September 1982
Deck/Cargo
Issued 23 September 1982 Resolved
MAKE PERMANENT REPAIRS TO TWO TEMPORARY AND ONE POORLY PATCHED PIPES IN OVERHEAD OF THE STBD SIDE "P" TANK ROOM.
Condition: Unknown
Due 23 September 1982
Resolved 23 September 1982
Electrical
Issued 23 September 1982 Resolved
PROVIDE ALL EXPLOSION PROOF EQUIPMENT IN DRILLERS SHACK OR AIR PURGE THE SHACK WITH BLOWER,SELF CLOSING DOOR AND VENTILATION LOSS ALARM.
Condition: Unknown
Due 23 September 1982
Resolved 23 September 1982
Deck/Cargo
Issued 23 September 1982 Resolved
INSURE INTAKE AIR FOR SCHLUMBERGER IS DRAWN FROM AN UNCLASSIFIED LOCATION AND THAT EXHAUST FROM SCHLUMBERGER EXPELLS IN A NON CLASSIFIED LOCATION
Condition: Unknown
Due 23 September 1982
Resolved 23 September 1982
Unknown
Issued 9 April 1982 Resolved
CLEARED ITEMS #7,9,10,11,13,14,15,17F,17G AND 18 FROM [name withheld] 09MAR82.
Condition: Unknown
Due 9 April 1982
Resolved 9 April 1982
Electrical
Issued 9 March 1982 Resolved
PROVIDE EXPLOSION PROOF JUNCTION BOXES ON DRILL FLOOR IF NECESSARY.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
PROVIDED EXPLOSION PROOF ELECTRICAL OUTLETS ON DRILLFLOOR AS NECESSARY.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Documentation
Issued 9 March 1982 Resolved
JPROVIDE CONSTRUCTION PORTFOLIO FOR VESSEL, APPROVED BY THE COAST GUARD 46 CFR 107.305 HH.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Documentation
Issued 9 March 1982 Resolved
PROVIDE HAZARDOUS LOCATION PLAN FOR VESSELS IAW 46 CFR 111.05-5(C) 22.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Documentation
Issued 9 March 1982 Resolved
MAINTAIN CRANE RECORD BOOK AS REQUIRED BY 46 CFR 109.437.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Documentation
Issued 9 March 1982 Resolved
PROVIDE CRANE LOAD TESTING CERTIFICATES IAW 46 CFR 109.439.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Documentation
Issued 9 March 1982 Resolved
REVISE STATON BILL TO ENCOMPASS JOB DESIGNATIONS, LOCATIONS WHERE PEOPLE ARE TO REPORT TO: ECT IN ACCORDANCE WITH 46 CFR 109.501.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Documentation
Issued 9 March 1982 Resolved
SSTART AND MAINTAIN VESSEL LOG AS REQUIRED BY 46 CFR 109.431-433.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
TEST EMERGENCY POWER AND MAINTAIN RECORD OF SAME AS PER 46 CFR 109.211.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Unknown
Issued 9 March 1982 Resolved
PROVIDE EXPLOSION PROOF 3 CELL FLASHLIGHTS FOR EACH FIREMANS OUTFIT 46 CFR 109.337.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Lifesaving
Issued 9 March 1982 Resolved
REPAIR OR REPLACE INBOARD LIMIT SWITCH FOR PORT LIFEBOAT AND REPLACE LIFE LINE FOR SAME.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Lifesaving
Issued 9 March 1982 Resolved
REPAIR OR REPLACE INBOARD LIMIT SWITCH FOR STARBOARD LIFEBOAT AND REPLACE LIFELINE FOR SAME.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Documentation
Issued 9 March 1982 Resolved
PROVIDE MARINE DOCUMENT FOR VESSEL.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Unknown
Issued 9 March 1982 Resolved
CONDUCT A SATISFACTORY FIRE DRILL.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Deck/Cargo
Issued 9 March 1982 Resolved
PROVIDE DEAD MAN TYPE FUEL FILL NOZZELS FOR CRANE FUELING STATIONS.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Documentation
Issued 9 March 1982 Resolved
PROVIDE FUEL OIL TRANSFERS PROCEDURES AS REQUIRED BY 33 CFR 155.720 AND TO CONTAIN THE REQUIREMENTS OF 33 CFR 155.750.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
REPAIR FOR PROPER OPERATION THE GENERAL ALARM BELLS IN THE FOLLOWING LOCA- TIONS -1.STARBOARD,2.FOREWARD LEG JACKING HOUSE 3.MUD PUMP ROOM
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
STENCIL ALL GENERAL ALARM BELLS AND FLASHING LIGHTS.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
MAKE THE FOLLOWING AREAS SUITABLE FOR CLASSIFIED LOCATIONS; MAKE THE DRILLERS SLACK EXPLOSION PROOF, ARE PURGED OR INDEFENIATLY SAFE.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
PROVIDE SUITABLE BELLS FOR CLASSIFIED LOCATIONS TO INCLUDE GENERAL ALARM BELLS AND TELEPHONE BELLS.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
PROVIDE EXPLOSION PROOF PHONE FOR THE DRILERS CONSOLE.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
PROVIDE EXPLOSION PROOF LIGHTS ON DRILL FLOOR AS REQUIRED.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
PROVIDE EXPLOSION PROOF CONTROLLERS AND SWITCHES FOR BUG BLOWERS.
Condition: Unknown
Due 9 April 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
PROVIDE EYS SEALS FOR LIGHTS, JUNCTION BOXES, DRAWWORKS MOTORS, BLOWER MOT-ORS, DYNAMIC BRAKE TRANFORMERS, OUTLETS AS NEEDED.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
PLACE WIRING IN WIRE RUNS.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
REMOVE SCHUMBERGER UNIT FROM DRILL FLOOR OR ROUTE INTAKE AND EXHAUST OUT OFCLASSIFIED AREA.
Condition: Unknown
Due 9 April 1982
Resolved 8 April 2002
Electrical
Issued 9 March 1982 Resolved
PROVIDE EXPLOSION PROOF LIGHTS FOR SCHLUMBERGER UNIT.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Lifesaving
Issued 9 March 1982 Resolved
PROVIDE 500 FOOT AUXILARY LINE FOR SHOULDER LINE FOR THROWING GUN.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Lifesaving
Issued 9 March 1982 Resolved
REPAIR OR REPLACE INBOARD LIMIT SWITCH FOR PORT LIFEBOAT AND REPLACE LIFE LINE FOR SAME.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Lifesaving
Issued 9 March 1982 Resolved
PROVIDE 500 FOOT AUXILARY LINE FOR SHOULDER LINE FOR THROWING GUN.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
PROVIDE SUITABLE BELLS FOR CLASSIFIED LOCATIONS TO INCLUDE GENERAL ALARM BELLS AND TELEPHONE BELLS.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
PROVIDE EXPLOSION PROOF JUNCTION BOXES ON DRILL FLOOR IF NECESSARY.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
PROVIDE EXPLOSION PROOF JUNCTION BOXES ON DRILL FLOOR IF NECESSARY.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
PROVIDE EXPLOSION PROOF ELECTRICAL OUTLETS ON DRILL FLOOR AS NECESSARY.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
PROVIDE EXPLOSION PROOF LIGHTS ON DRILL FLOOR AS REQUIRED.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
PROVIDE EYS SEALS FOR LIGHTS, JUNCTION BOXES, DRAWWORKS MOTOR, BLOWER MOTORS, DYNAMIC BRAKE TRANFORMERS, OUTLETS AS NEEDED.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
PLACE WIRING IN WIRE RUNS.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
PROVIDE EXPLOSION PROOF LIGHTS FOR SCHLUMBERGER UNIT.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Lifesaving
Issued 9 March 1982 Resolved
REPAIR OR REPLACE INBOARD LIMIT SWITCH FOR STARBOARD LIFEBOAT AND REPLACE LIFELINE FOR SAME.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Documentation
Issued 9 March 1982 Resolved
PROVIDE CONSTRUCTION FORTBOLIO FOR VESSEL, APPROVED BY THE COAST GUARD 46 CFR 107.305 HH.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Documentation
Issued 9 March 1982 Resolved
PROVIDE HAZARDOUS LOCATION PLAN FOR VESSELS IAW 46 CFR 111.05-5(C)22.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Documentation
Issued 9 March 1982 Resolved
MAINTAIN CRANE RECORD BOOK AS REQUIRED BY 46 CFR 109.439.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Documentation
Issued 9 March 1982 Resolved
PROVIDE CRANE LOAD TESTING CERTIFICATES IAW 46 CFR 109.429.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Documentation
Issued 9 March 1982 Resolved
REVISE STATION BILL TO ENCOMPASS JOB DESIGNATIONS, LOCATIONS WHERE PEOPLE ARE TO REPORT TO: ECT IN ACCORDANCE WITH 46 CFR 109.501.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Documentation
Issued 9 March 1982 Resolved
START AND MAINTAIN VESSEL LOG AS REQUIRED BY 46 CFR 109.431-433
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
TEST EMERGENCY POWER AND MAINTAIN RECORD OF SAME AS PER 46 CFR 109.211
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Unknown
Issued 9 March 1982 Resolved
PROVIDE EXPLOSION PROOF 3 CELL FLASHLIGHTS FOR EACH FIREMANS OUTFIT 46 CFR 109.337.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Documentation
Issued 9 March 1982 Resolved
PROVIDE MARINE DOCUMENT FOR VESSEL.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Unknown
Issued 9 March 1982 Resolved
CONDUCT A SATISFACTORY FIRE DRILL.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Deck/Cargo
Issued 9 March 1982 Resolved
PROVIDE DEAD MAN TYPE FUEL FILL NOZZELS FOR CRANE FUELING STATIONS
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Documentation
Issued 9 March 1982 Resolved
PROVIDE FUEL OIL TRANSFER PROCEDURES AS REQUIRED BY 33 CFR 155.720 AND TO CONTAIN THE REQUIREMENTS OF 33 CFR 155.750.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
REPAIR FOR PROPER OPERATION THE GENERAL ALARM BELLS IN THE FOLLOWING LOCA- TIONS -1. STARBOARD, 2. FOREWARD LEG JACKING HOUSE 3. MUD PUMP ROOM
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
STENCIL ALL GENERAL ALARM BELLS AND FLASHING LIGHTS.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982
Electrical
Issued 9 March 1982 Resolved
MAKE THE FOLLOWING AREAS SUITABLE FOR CLASSIFIED LOCATIONS; MAKE THE DRIL- LERS SHACK EXPLOSION PROOF, ARE PURGED OR INDEFENIATLY SAFE.
Condition: Unknown
Due 9 March 1982
Resolved 9 March 1982

Casualty record · 1

28 August 2005Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2503253
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

OCEAN WARWICK (2005). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.