MAURY USCG vessel records
← All vessels

UMTB 283

Built
1981
Last inspected
5 January 1989
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 37 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 5 January 1989
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 6 calendar years (1984–1989)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
3422 - Regulatory (Subpart C or D), Gross Ton 3422 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-53200
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

5 January 1989 Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1200962
27 September 1988 COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1195247
18 November 1987 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1024109
5 November 1986 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1015748
7 May 1986 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 477463
22 April 1986 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1307927
16 April 1986 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1000048
26 March 1986 Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 995505
5 December 1985 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 991190
8 November 1985 Credit Drydock · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 993175
21 December 1984 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1286068
2 November 1984 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 442202

Deficiency record · 10

Deck/Cargo
Issued 5 November 1986 Resolved
REPLACE WASTED LOUVER PLATES ON THE PRESSURE VACUUM VALVES THROUGHOUT THE VESSEL
Condition: Unknown
Due 5 November 1986
Resolved 5 November 1986
Deck/Cargo
Issued 5 November 1986 Resolved
THE CARGO PUMP RELIEF VALVES, CARGO PUMP PRESSURE GAUGE AND CARGO DISCHARGEPIPING ARE TO BE TESTED AS PER 46CFR35.35-70 AND THE RESULTS ENTERED IN THEVESSELS LOGBOOK BY A CERTIFIED TANKERMAN.
Condition: Unknown
Due 5 November 1986
Resolved 5 November 1986
Electrical
Issued 16 April 1986 Resolved
OUTSIDE DECK LIGHTS AND FITTINGS OVER FORWARD PORT AND STBD DOORS TO MACH- INERY SPACE NOT EXPLOSION PROOF AS REQUIRED BY 46 CFR 111.105-31(L).
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Electrical
Issued 16 April 1986 Resolved
ELECTRICAL EQUIPMENT ON FORWARD DECK LIGHT MAST ON MAIN DECK NOT EXPLOSION PROOF AS REQUIRED BY 46 CFR 111.105-31(L).
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Deck/Cargo
Issued 16 April 1986 Resolved
ALL P/V VALVE FLAME SCREEN RETAINING LOUVER PLATES WERE EITHER WASTED AWAY OR BENT OUT OF SHAPE TO WHERE THEY WOULD ALLOW AN OPEN FLAME TO ENTER CARGOTANKS. TOTAL OF 24 LOUVERS NEED REPLACEMENT.
Condition: Unknown
Due 16 April 1986
Resolved 16 April 1986
Construction/Loadline
Issued 26 March 1986 Resolved
GAS FREE CARGO TANK NO.6 STBD AND ADJACENT CARGO TANKS. MAKE PERMANENT REPAIRS TO HOLE AT LOAD WATER LINE. BRG IS PERMITTED TO MAKE ROUNDTRIP TO ALASKA TO OFFLOAD CARGO. NO. 6 NOT TO BE USED FOR CARGO. SOFT PATCH TO BE APPLIED. PERMANENT REPAIRS NOT LATER THAN 25 APRIL 1986.
Condition: Unknown
Due 26 March 1986
Resolved 26 March 1986
Deck/Cargo
Issued 8 November 1985 Resolved
SUBMIT BURST PRESSURES FOR HYDRAULIC SYSTEM RETURN FILTERS
Condition: Unknown
Due 8 November 1985
Resolved 8 November 1985
Deck/Cargo
Issued 8 November 1985 Resolved
SUBMIT BURST CALCULATIONS FOR SIDE THRUSTER HYDRAULIC SYSTEM FLEXIBLE HOSES.
Condition: Unknown
Due 8 November 1985
Resolved 8 November 1985
Deck/Cargo
Issued 8 November 1985 Resolved
PROVIDE MANUFACTORS DATA REPORT FOR S/S AIR RECEIVER.
Condition: Unknown
Due 8 November 1985
Resolved 8 November 1985
Unknown
Issued 21 December 1984 Resolved
MAKE PERMANENT REPAIRS TO THE BUCKLED CENTERLINE BULKHEAD IN NO. 1 AND NO. 2 PORT AND STARBOARD VOIDS BETWEEN FRAME 8 (EIGHT) AND 10 (TEN) (46 CFR 91.25-10(A)).
Condition: Unknown
Due 21 December 1984
Resolved 21 December 1984

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.