QUARLES DRILLG CP DRL BRG RIG #21

QUARLES DRILLG CP DRL BRG RIG #21 is a 1956 mobile offshore drilling unit. The Coast Guard has recorded 13 inspections since 1982, most recently in May 1986, along with 76 deficiencies.

Records from 1982 to 1986. Most recent: inspection, 13 May 1986.

Built
1956
Last inspected
13 May 1986
Documentation
Invalid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WH5607
Flag
UNITED STATES
—
Maury page id
psix-53205

Inspections, by type

…with no type recorded12
Years with a record 5 calendar years (1982–1986)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 40 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)156.0 ft × 114.0 ft × 10.5 ft
Registered tonnagegross 1,737 / net 1,737
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · AVONDALE LA · built 1956
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNot recorded
Trade endorsementsCoastwise, unrestricted
DocumentationInvalid
Service, as the file records itMobile Offshore Drilling Unit
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1737 - Regulatory (Subpart C or D), Net Ton
1737 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 13

13 May 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988796
6 November 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1304291
1 November 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290137
14 June 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1288135
4 June 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280889
9 May 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 974189
10 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970771
27 June 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274062
22 June 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963531
9 May 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966819
5 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970426
6 August 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273713
4 June 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272012

Deficiency record · 76

Electrical
Issued 1 November 1984 Resolved
REPAIR OR REPLACE INOPERATIVE BUNK LIGHTS REF. 46 CFR 108.203.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 1 November 1984 Resolved
SUBMIT FOR APPROVAL THE FIRE CONTROL PLAN AND HAZARDOUS LOCATION PLAN TO THE [name withheld] AS REQUIRED BY 46 CFR 107.305.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Construction/Loadline
Issued 1 November 1984 Resolved
WELD CLOSED THE GAPS AND OPEN HOLES IN THE PAINT LOCKER, REF 46 CFR 108.127
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Construction/Loadline
Issued 1 November 1984 Resolved
MAKE PERMANENT REPAIRS TO THE KEEL COOLER PIPING IN WAY OF THE SOFT PATCHES.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Engineering
Issued 1 November 1984 Resolved
REPLACE ALL BRAS FUEL VALVES FITTINGS AS NECESARY ON THE FUEL OIL DAY TANKS46 CFR 6.50.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Deck/Cargo
Issued 1 November 1984 Resolved
PROVIDE APPROVED FUEL OIL TRANSFER PROCEDURES ON BOARD THE RIG AS REQUIRED BY 46 CFR 155.720.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Electrical
Issued 1 November 1984 Resolved
REPLACE THE MISSING DEAD FRONT PANEL ON THE LIGHTING SWITCH PANEL IN THE MOTOR CONTROL ROOM.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Lifesaving
Issued 1 November 1984 Resolved
CONDUCT A FIRE AND BOAT DRILL.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Accommodation/Occupational Safety
Issued 1 November 1984 Resolved
PROVIDE A VENTILATION SYSTEM THAT WILL NOT ALLOW ODORS FROM TOILET SPACES TO READILY ENTER THE SLEEPING, MESS OR RECREATIONAL SPACES REQUIRED BY 46 CFR 108.197(F).
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Engineering
Issued 1 November 1984 Resolved
PROVIDE UL MARINE TYPE FILTERS AS NEEDED ON THE MAIN AND EMERGENCY GENERATOR 46 CFR 56.50.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 1 November 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL, QUARLES RIG 21, DN272768 AND ARE TO BE COMPLIED WITH BY 09NOV84.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 4 June 1984 Resolved
THE FOLLOWING DEFICIENCY IS FOR THE QUARLES RIG 21, DN272768.
Condition: Unknown
Due 4 June 1984
Resolved 4 June 1984
Unknown
Issued 4 June 1984 Resolved
COMPLETE CREDIT DRYDOCK EXAMINATION.
Condition: Unknown
Due 4 June 1984
Resolved 4 June 1984
Fire Fighting
Issued 22 June 1983 Resolved
PROVIDE 10" LOW VELOCITY FOG APPLICATOR TO FIRE STTION NO. 12
Condition: Unknown
Due 22 June 1983
Resolved 22 June 1983
Fire Fighting
Issued 9 May 1983 Resolved
PROVIDE SPANNERS FOR FIRE STATIONS 11 AND 12.
Condition: Unknown
Due 9 May 1983
Resolved 9 May 1983
Unknown
Issued 9 May 1983 Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL QUARLES RIG 21, DN272768
Condition: Unknown
Due 9 May 1983
Resolved 9 May 1983
Fire Fighting
Issued 5 April 1983 Resolved
PROPERLY MOUNT FIRE SENSOR HOUSING IN PUMP ROOM.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Unknown
Issued 5 April 1983 Resolved
REPLACE MISSING VALVE HANDLE AT DECK NEXT TO BILGE PUMP.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Accommodation/Occupational Safety
Issued 5 April 1983 Resolved
REPLACE MISSING SECTION OF GRATING ON DECK AT BASE OF PUMP ROOM ESCAPE LADDER.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983 Resolved
CLOSE COVER ON WIRES ON FORWARD HOT WATER TANK AND PIPE RELIEF VALVE DISCHARGE AWAY FROM CONNECTIONS.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Deck/Cargo
Issued 5 April 1983 Resolved
REPAIR GUARD ON LUBE OIL PUMP COUPLING FOR NO. 1 MUD PUMP.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Deck/Cargo
Issued 5 April 1983 Resolved
PROPERLY MOUNT STROKE COUNTER JUNCTION BOX IN MUD PUMP ROOM.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Unknown
Issued 5 April 1983 Resolved
(REQ. 6 CONTINUED) OBSTRUCTION LIGHT.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Lifesaving
Issued 5 April 1983 Resolved
PROVIDE ONE PADDLE FOR RESCUE BOAT.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983 Resolved
PROVIDE GUARD FOR GLOBE ON LIGHT IN PAINT LOCKER.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Fire Fighting
Issued 5 April 1983 Resolved
PROVIDE OPERATING INSTRUCTIONS FOR CO2 SYSTEM FOR PUMP ROOM.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Fire Fighting
Issued 5 April 1983 Resolved
HYDROSTATICALLY TEST THE CO2 BOTTLES IN THE PUMP ROOM CO2 SYSTEM.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983 Resolved
IN THE DRILL FLOOR CLASSIFIED AREA: (A) REMOVE DEAD END CABLE BY FIRE EXTINGUISHER 14 (B) MAKE GENERAL ALARM CONTACT MAKER SUITABLE FOR HAZARDOUS
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983 Resolved
(REQ. 11 CONTINUED) LOCATION (C) ROUTE AIR INTAKE FOR SCHLUM-BERGER UNIT OUTSIDE SPACE.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983 Resolved
IN THE SHALE SHAKER CLASSIFIED AREA REMOVE DEAD END CABLES AT: (A) FORWARDOUTLET (B) AFT STARBOARD OUTLET (C) AFT OF MUD LAB, FROM OVERHEAD RUN
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983 Resolved
REMOVE SPLICED WIRE FROM BUGBLOWER BETWEEN NO.1 AND NO.2 EMD.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983 Resolved
(C) PROVIDE GUARD ON LIGHT PORT SIDE IN STORAGE AREA. (B) MAKE WELDING OUTLET AT FIRE EXTINGUISHER 27 SUITABLE FOR HAZARDOUS AREA OR REMOVE.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Accommodation/Occupational Safety
Issued 5 April 1983 Resolved
REPLACE RELIEF VALVE ON BULK AIR STORAGE TANK WITH MAXIMUM 200 PSI VALVE WITH HAND RELIEVING GEAR.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Accommodation/Occupational Safety
Issued 5 April 1983 Resolved
REPLACE 2 RIG AIR RECEIVER RELIEF VALVES WITH 200 PSI VALVES WITH HAND RELIEVING GEAR.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983 Resolved
PROVIDE BLANKS IN THESE PANELS: RED PANEL IN MUD PUMP ROOM QUARTERS DISTRIBUTION PANEL IN SWITCH GEAR ROOM WASHER PANEL IN LAUNDRY.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Accommodation/Occupational Safety
Issued 5 April 1983 Resolved
PROVIDE SUPPORT BRACKET FOR HOT WATER HEATER DRAIN LINE.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983 Resolved
PROVIDE NON-CORROSIVE LINING FOR OBSTRUCTION LIGHT BATTERY BOX.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Construction/Loadline
Issued 5 April 1983 Resolved
MARK BILGE FLOODING LIGHT IN ENGINEROOM.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983 Resolved
IN SHALE SHAKER CLASSIFIED AREA: (D) PROVIDE EYS SEAL ON DESILTER MOTOR.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983 Resolved
IN THE MUD PITS CLASSIFIED ARE: (A) REMOVE 2 SPLICES OVER MUD THROUGH OUTBOARD. (B) PROVIDE EYS SEAL ON STARBOARD FORWARD AGITATOR MOTOR.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Unknown
Issued 5 April 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TTO THE VESSEL QUARLES RIG 21, DN272768.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Lifesaving
Issued 5 April 1983 Resolved
PROVIDE PFD LIGHTS FOR 21 LIFE PRESERVERS AND REFLECTIVE TAPE FOR THREE (3)MISSING THESE ITEMS.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Deck/Cargo
Issued 5 April 1983 Resolved
PROVIDE LOAD CHART IN STARBOARD CRANE CAB AND HAND SIGNAL CHARTS IN BOTH CRANE CABS.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Documentation
Issued 5 April 1983 Resolved
PROVIDE STARBOARD CRANE LOAD CHART AND BOTH CRANES NAME PLATE DATA IN CRANERECORD BOOK.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Lifesaving
Issued 5 April 1983 Resolved
HAVE HYDROSTATIC RELEASES FOR ALL LIFERAFTS SERVICED AT AN APPROVED FACILITY.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Fire Fighting
Issued 5 April 1983 Resolved
PROVIDE EQUIPMENT FOR FIRE STATIONS AS INDICATED: (1) FIRE STATION 2: HIGH VELOCITY FOG NOZZLE (2) FIRE STATION 3: LOW VELOCITY FOG APPLICATOR,
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Fire Fighting
Issued 5 April 1983 Resolved
(REQ. 5 CONTINUED) NEW NOZZLE, SPANNER WRENCH (3) FIRE STATION 5,9,10,11, 12: SPANNERS (4) FIRE STATION 4: LOW VELOCITY FOG APPLICATOR, SPANNER.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Navigation
Issued 5 April 1983 Resolved
PROVIDE REPLACEMENT LENS FOR FORWARD STARBOARD NAVIGATION OBSTRUCTION LIGHTAND REPAIR/REPLACE LAMP CHANGER IN FORWARD PORT NAVIGATION
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 4 June 1982 Resolved
MAKE WELDING CABLE IN SACK ROOM SUITABLE FOR INSTALLATION IN A CLASSIFIED AREA IAW 46 CFR 111.80 OR NFPA 496
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982 Resolved
MAKE ANALIZER ON DRILL FLOOR SUIITABLE FOR INSTALLATION IN A CLASSIFIED AREA IAW 46 CFR 111.80 OR NFPA 496.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982 Resolved
MAKE MUD MONITER ON DRILLL FLOOR SUITABLE FOR INSTALLATION IN CLASSIFIED AREA IAW 46 CFR 111.80 OR NFPA 4F96
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982 Resolved
MAKE DRAWWORKS BLOWER MOTORS (2) TERMINAL BOXES SUITABLE FOR INSTALLATION IN CLASSIFIED AREA.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982 Resolved
MAKE DRAWWORKS TERMINAL SPLICES SUITABLE FOR INSTALLION IN CLASSIFIED AREA IAW 46 CFR 111.80 OR NFPA 496
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982 Resolved
MAKE EYE SEALS ON SHALE SHAKER CONTROLS AND THROUGHOUT CLASSIFIED AREAS SUITABLE FOR INSTALLATION IN CLASSIFIED AREAS.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982 Resolved
MAKE DRAWWORKS MUD PUMP CONTROL PANEL SUITALBE FOR INSTALLATION IN CLASS- IFIED AREAS
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982 Resolved
MAKE SPLICES IN ELECTRICAL CABLE AT DRAW WORKS AND VICINITY OF MUD TROUGH SUITABLE FOR INSTALLATION IN CLASSIFIED AREA.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Unknown
Issued 4 June 1982 Resolved
PROVIDE CG APPROVED CLASSIFIED AREA DRAWING REQUIRED BY 46 CFR 111.05
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982 Resolved
RELOCATE MACHINERY SPACE VENTILATION SHUTDOWN OUTSIDE MOTOR ROOM AS REQUIRED BY 46 CFR 111.80-10.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982 Resolved
REMOVE DEADENDED CABLE FROM MOTOR ROOM PORT CORNER AFT.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982 Resolved
REPLACE MOTOR TERMINAL BOX COVER FOR BRAKE COOLING WATER PUMP.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Unknown
Issued 4 June 1982 Resolved
REPAIR BROKEN PIPE HANGERS (3) IN PUMP ROOM.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Unknown
Issued 4 June 1982 Resolved
PROVIDE GUARD FOR MUD PUMP ROOM OR TUGGER AS REQUIRED BY 46 CFR 108.223.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Unknown
Issued 4 June 1982 Resolved
REPLACE TERMINAL BOX COVER AND GUARD FOR WASTE OIL PUMP AS REQUIRED BY 46 CFR 108.223.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982 Resolved
PROVIDE QUARTERS VENTILATION SHUTDOWNS AS REQUIRED BY 46 CFR 111.80-10,13
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Unknown
Issued 4 June 1982 Resolved
RENEW AND TEST IN PRESENCE OF INSPECTOR (4) RELIEF VALVES FOR "P" TANKS AS REQUIRED BY 46 CFR 43.15.13.(E)
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Documentation
Issued 4 June 1982 Resolved
PROVIDE WITH CG STABILITY LETTER.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Navigation
Issued 4 June 1982 Resolved
PROVIDE RIG WITH BELL
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Construction/Loadline
Issued 4 June 1982 Resolved
CLEAN OR POINT DRAFT MARKS
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Deck/Cargo
Issued 4 June 1982 Resolved
CONDUCT ANNUAL CRANE INSPECTION IAW 46 CFR 107.259.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Unknown
Issued 4 June 1982 Resolved
STENCIL ALL GENERAL ALARMS "WHEN BELL RINGS GO TO YOUR STATIONS"
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Unknown
Issued 4 June 1982 Resolved
PROVIDE PROPER NAME ON RIG
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Lifesaving
Issued 4 June 1982 Resolved
PROPERLY SERVICE AVON RESCUE BOAT TO HOLD PROPER INFLATION.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Unknown
Issued 4 June 1982 Resolved
PROPERLY SERVICE GENERAL ALARM, FIRE ALARM TO SOUND PROPER SIGNALS
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Construction/Loadline
Issued 4 June 1982 Resolved
PROVIDE RIG WITH WEATHERTIGHT WINDOWS VISE TAPE AND PLASTIC FOR PRESENT WINDOWS
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982 Resolved
PROPERLY SECURE SUPPORT ELECTRICAL CABLE WITH METAL SUPPORTS THROUGH OUT THE RIG.
Condition: Unknown
Due 5 July 1982
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 4 June 1982 Resolved
MAKE SUITABLE INSTALLATION OF WELDING LEAD ON TEXAS DECK IN ACCORDANCE WITH46 CFR 111.80 OR NFPA 496
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.