Records from 1982 to 1986. Most recent: inspection, 13 May 1986.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Electrical
Issued 1 November 1984
Resolved
REPAIR OR REPLACE INOPERATIVE BUNK LIGHTS REF. 46 CFR 108.203.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 1 November 1984
Resolved
SUBMIT FOR APPROVAL THE FIRE CONTROL PLAN AND HAZARDOUS LOCATION PLAN TO THE [name withheld] AS REQUIRED BY 46 CFR 107.305.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Construction/Loadline
Issued 1 November 1984
Resolved
WELD CLOSED THE GAPS AND OPEN HOLES IN THE PAINT LOCKER, REF 46 CFR 108.127
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Construction/Loadline
Issued 1 November 1984
Resolved
MAKE PERMANENT REPAIRS TO THE KEEL COOLER PIPING IN WAY OF THE SOFT PATCHES.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Engineering
Issued 1 November 1984
Resolved
REPLACE ALL BRAS FUEL VALVES FITTINGS AS NECESARY ON THE FUEL OIL DAY TANKS46 CFR 6.50.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Deck/Cargo
Issued 1 November 1984
Resolved
PROVIDE APPROVED FUEL OIL TRANSFER PROCEDURES ON BOARD THE RIG AS REQUIRED BY 46 CFR 155.720.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Electrical
Issued 1 November 1984
Resolved
REPLACE THE MISSING DEAD FRONT PANEL ON THE LIGHTING SWITCH PANEL IN THE MOTOR CONTROL ROOM.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Lifesaving
Issued 1 November 1984
Resolved
CONDUCT A FIRE AND BOAT DRILL.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Accommodation/Occupational Safety
Issued 1 November 1984
Resolved
PROVIDE A VENTILATION SYSTEM THAT WILL NOT ALLOW ODORS FROM TOILET SPACES TO READILY ENTER THE SLEEPING, MESS OR RECREATIONAL SPACES REQUIRED BY 46 CFR 108.197(F).
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Engineering
Issued 1 November 1984
Resolved
PROVIDE UL MARINE TYPE FILTERS AS NEEDED ON THE MAIN AND EMERGENCY GENERATOR 46 CFR 56.50.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 1 November 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL, QUARLES RIG 21, DN272768 AND ARE TO BE COMPLIED WITH BY 09NOV84.
Condition: Unknown
Due 1 November 1984
Resolved 1 November 1984
Unknown
Issued 4 June 1984
Resolved
THE FOLLOWING DEFICIENCY IS FOR THE QUARLES RIG 21, DN272768.
Condition: Unknown
Due 4 June 1984
Resolved 4 June 1984
Unknown
Issued 4 June 1984
Resolved
COMPLETE CREDIT DRYDOCK EXAMINATION.
Condition: Unknown
Due 4 June 1984
Resolved 4 June 1984
Fire Fighting
Issued 22 June 1983
Resolved
PROVIDE 10" LOW VELOCITY FOG APPLICATOR TO FIRE STTION NO. 12
Condition: Unknown
Due 22 June 1983
Resolved 22 June 1983
Fire Fighting
Issued 9 May 1983
Resolved
PROVIDE SPANNERS FOR FIRE STATIONS 11 AND 12.
Condition: Unknown
Due 9 May 1983
Resolved 9 May 1983
Unknown
Issued 9 May 1983
Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL QUARLES RIG 21, DN272768
Condition: Unknown
Due 9 May 1983
Resolved 9 May 1983
Fire Fighting
Issued 5 April 1983
Resolved
PROPERLY MOUNT FIRE SENSOR HOUSING IN PUMP ROOM.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Unknown
Issued 5 April 1983
Resolved
REPLACE MISSING VALVE HANDLE AT DECK NEXT TO BILGE PUMP.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Accommodation/Occupational Safety
Issued 5 April 1983
Resolved
REPLACE MISSING SECTION OF GRATING ON DECK AT BASE OF PUMP ROOM ESCAPE LADDER.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983
Resolved
CLOSE COVER ON WIRES ON FORWARD HOT WATER TANK AND PIPE RELIEF VALVE DISCHARGE AWAY FROM CONNECTIONS.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Deck/Cargo
Issued 5 April 1983
Resolved
REPAIR GUARD ON LUBE OIL PUMP COUPLING FOR NO. 1 MUD PUMP.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Deck/Cargo
Issued 5 April 1983
Resolved
PROPERLY MOUNT STROKE COUNTER JUNCTION BOX IN MUD PUMP ROOM.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Unknown
Issued 5 April 1983
Resolved
(REQ. 6 CONTINUED) OBSTRUCTION LIGHT.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Lifesaving
Issued 5 April 1983
Resolved
PROVIDE ONE PADDLE FOR RESCUE BOAT.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983
Resolved
PROVIDE GUARD FOR GLOBE ON LIGHT IN PAINT LOCKER.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Fire Fighting
Issued 5 April 1983
Resolved
PROVIDE OPERATING INSTRUCTIONS FOR CO2 SYSTEM FOR PUMP ROOM.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Fire Fighting
Issued 5 April 1983
Resolved
HYDROSTATICALLY TEST THE CO2 BOTTLES IN THE PUMP ROOM CO2 SYSTEM.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983
Resolved
IN THE DRILL FLOOR CLASSIFIED AREA: (A) REMOVE DEAD END CABLE BY FIRE EXTINGUISHER 14 (B) MAKE GENERAL ALARM CONTACT MAKER SUITABLE FOR HAZARDOUS
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983
Resolved
(REQ. 11 CONTINUED) LOCATION (C) ROUTE AIR INTAKE FOR SCHLUM-BERGER UNIT OUTSIDE SPACE.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983
Resolved
IN THE SHALE SHAKER CLASSIFIED AREA REMOVE DEAD END CABLES AT: (A) FORWARDOUTLET (B) AFT STARBOARD OUTLET (C) AFT OF MUD LAB, FROM OVERHEAD RUN
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983
Resolved
REMOVE SPLICED WIRE FROM BUGBLOWER BETWEEN NO.1 AND NO.2 EMD.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983
Resolved
(C) PROVIDE GUARD ON LIGHT PORT SIDE IN STORAGE AREA. (B) MAKE WELDING OUTLET AT FIRE EXTINGUISHER 27 SUITABLE FOR HAZARDOUS AREA OR REMOVE.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Accommodation/Occupational Safety
Issued 5 April 1983
Resolved
REPLACE RELIEF VALVE ON BULK AIR STORAGE TANK WITH MAXIMUM 200 PSI VALVE WITH HAND RELIEVING GEAR.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Accommodation/Occupational Safety
Issued 5 April 1983
Resolved
REPLACE 2 RIG AIR RECEIVER RELIEF VALVES WITH 200 PSI VALVES WITH HAND RELIEVING GEAR.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983
Resolved
PROVIDE BLANKS IN THESE PANELS: RED PANEL IN MUD PUMP ROOM QUARTERS DISTRIBUTION PANEL IN SWITCH GEAR ROOM WASHER PANEL IN LAUNDRY.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Accommodation/Occupational Safety
Issued 5 April 1983
Resolved
PROVIDE SUPPORT BRACKET FOR HOT WATER HEATER DRAIN LINE.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983
Resolved
PROVIDE NON-CORROSIVE LINING FOR OBSTRUCTION LIGHT BATTERY BOX.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Construction/Loadline
Issued 5 April 1983
Resolved
MARK BILGE FLOODING LIGHT IN ENGINEROOM.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983
Resolved
IN SHALE SHAKER CLASSIFIED AREA: (D) PROVIDE EYS SEAL ON DESILTER MOTOR.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 5 April 1983
Resolved
IN THE MUD PITS CLASSIFIED ARE: (A) REMOVE 2 SPLICES OVER MUD THROUGH OUTBOARD. (B) PROVIDE EYS SEAL ON STARBOARD FORWARD AGITATOR MOTOR.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Unknown
Issued 5 April 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TTO THE VESSEL QUARLES RIG 21, DN272768.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Lifesaving
Issued 5 April 1983
Resolved
PROVIDE PFD LIGHTS FOR 21 LIFE PRESERVERS AND REFLECTIVE TAPE FOR THREE (3)MISSING THESE ITEMS.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Deck/Cargo
Issued 5 April 1983
Resolved
PROVIDE LOAD CHART IN STARBOARD CRANE CAB AND HAND SIGNAL CHARTS IN BOTH CRANE CABS.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Documentation
Issued 5 April 1983
Resolved
PROVIDE STARBOARD CRANE LOAD CHART AND BOTH CRANES NAME PLATE DATA IN CRANERECORD BOOK.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Lifesaving
Issued 5 April 1983
Resolved
HAVE HYDROSTATIC RELEASES FOR ALL LIFERAFTS SERVICED AT AN APPROVED FACILITY.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Fire Fighting
Issued 5 April 1983
Resolved
PROVIDE EQUIPMENT FOR FIRE STATIONS AS INDICATED: (1) FIRE STATION 2: HIGH VELOCITY FOG NOZZLE (2) FIRE STATION 3: LOW VELOCITY FOG APPLICATOR,
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Fire Fighting
Issued 5 April 1983
Resolved
(REQ. 5 CONTINUED) NEW NOZZLE, SPANNER WRENCH (3) FIRE STATION 5,9,10,11, 12: SPANNERS (4) FIRE STATION 4: LOW VELOCITY FOG APPLICATOR, SPANNER.
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Navigation
Issued 5 April 1983
Resolved
PROVIDE REPLACEMENT LENS FOR FORWARD STARBOARD NAVIGATION OBSTRUCTION LIGHTAND REPAIR/REPLACE LAMP CHANGER IN FORWARD PORT NAVIGATION
Condition: Unknown
Due 5 April 1983
Resolved 5 April 1983
Electrical
Issued 4 June 1982
Resolved
MAKE WELDING CABLE IN SACK ROOM SUITABLE FOR INSTALLATION IN A CLASSIFIED AREA IAW 46 CFR 111.80 OR NFPA 496
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982
Resolved
MAKE ANALIZER ON DRILL FLOOR SUIITABLE FOR INSTALLATION IN A CLASSIFIED AREA IAW 46 CFR 111.80 OR NFPA 496.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982
Resolved
MAKE MUD MONITER ON DRILLL FLOOR SUITABLE FOR INSTALLATION IN CLASSIFIED AREA IAW 46 CFR 111.80 OR NFPA 4F96
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982
Resolved
MAKE DRAWWORKS BLOWER MOTORS (2) TERMINAL BOXES SUITABLE FOR INSTALLATION IN CLASSIFIED AREA.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982
Resolved
MAKE DRAWWORKS TERMINAL SPLICES SUITABLE FOR INSTALLION IN CLASSIFIED AREA IAW 46 CFR 111.80 OR NFPA 496
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982
Resolved
MAKE EYE SEALS ON SHALE SHAKER CONTROLS AND THROUGHOUT CLASSIFIED AREAS SUITABLE FOR INSTALLATION IN CLASSIFIED AREAS.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982
Resolved
MAKE DRAWWORKS MUD PUMP CONTROL PANEL SUITALBE FOR INSTALLATION IN CLASS- IFIED AREAS
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982
Resolved
MAKE SPLICES IN ELECTRICAL CABLE AT DRAW WORKS AND VICINITY OF MUD TROUGH SUITABLE FOR INSTALLATION IN CLASSIFIED AREA.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Unknown
Issued 4 June 1982
Resolved
PROVIDE CG APPROVED CLASSIFIED AREA DRAWING REQUIRED BY 46 CFR 111.05
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982
Resolved
RELOCATE MACHINERY SPACE VENTILATION SHUTDOWN OUTSIDE MOTOR ROOM AS REQUIRED BY 46 CFR 111.80-10.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982
Resolved
REMOVE DEADENDED CABLE FROM MOTOR ROOM PORT CORNER AFT.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982
Resolved
REPLACE MOTOR TERMINAL BOX COVER FOR BRAKE COOLING WATER PUMP.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Unknown
Issued 4 June 1982
Resolved
REPAIR BROKEN PIPE HANGERS (3) IN PUMP ROOM.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Unknown
Issued 4 June 1982
Resolved
PROVIDE GUARD FOR MUD PUMP ROOM OR TUGGER AS REQUIRED BY 46 CFR 108.223.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Unknown
Issued 4 June 1982
Resolved
REPLACE TERMINAL BOX COVER AND GUARD FOR WASTE OIL PUMP AS REQUIRED BY 46 CFR 108.223.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982
Resolved
PROVIDE QUARTERS VENTILATION SHUTDOWNS AS REQUIRED BY 46 CFR 111.80-10,13
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Unknown
Issued 4 June 1982
Resolved
RENEW AND TEST IN PRESENCE OF INSPECTOR (4) RELIEF VALVES FOR "P" TANKS AS REQUIRED BY 46 CFR 43.15.13.(E)
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Documentation
Issued 4 June 1982
Resolved
PROVIDE WITH CG STABILITY LETTER.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Navigation
Issued 4 June 1982
Resolved
PROVIDE RIG WITH BELL
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Construction/Loadline
Issued 4 June 1982
Resolved
CLEAN OR POINT DRAFT MARKS
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Deck/Cargo
Issued 4 June 1982
Resolved
CONDUCT ANNUAL CRANE INSPECTION IAW 46 CFR 107.259.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Unknown
Issued 4 June 1982
Resolved
STENCIL ALL GENERAL ALARMS "WHEN BELL RINGS GO TO YOUR STATIONS"
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Unknown
Issued 4 June 1982
Resolved
PROVIDE PROPER NAME ON RIG
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Lifesaving
Issued 4 June 1982
Resolved
PROPERLY SERVICE AVON RESCUE BOAT TO HOLD PROPER INFLATION.
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Unknown
Issued 4 June 1982
Resolved
PROPERLY SERVICE GENERAL ALARM, FIRE ALARM TO SOUND PROPER SIGNALS
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Construction/Loadline
Issued 4 June 1982
Resolved
PROVIDE RIG WITH WEATHERTIGHT WINDOWS VISE TAPE AND PLASTIC FOR PRESENT WINDOWS
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982
Electrical
Issued 4 June 1982
Resolved
PROPERLY SECURE SUPPORT ELECTRICAL CABLE WITH METAL SUPPORTS THROUGH OUT THE RIG.
Condition: Unknown
Due 5 July 1982
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 4 June 1982
Resolved
MAKE SUITABLE INSTALLATION OF WELDING LEAD ON TEXAS DECK IN ACCORDANCE WITH46 CFR 111.80 OR NFPA 496
Condition: Unknown
Due 4 June 1982
Resolved 4 June 1982