Documentation record
Registered dimensions (L × B × D)88.4 ft × 15.8 ft × 7.1 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDEFOE BOAT & MOTOR WORKS · BAY CITY, MI, UNITED STATES · built 1931
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPALM BEACH, FL
Endorsements, as the file codes themcw_un, rec
DocumentationValid · issued 12 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it94 - Regulatory (Subpart C or D), Gross Ton
64 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 9 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 9
3 March 2026
Internal Structural Exam · Administrative Inspection · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8319494
12 January 2026
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8295098
17 December 2024
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8048684
25 March 2024
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7884477
31 October 2018
Drydock Exam · Deficiency Check · Construction Oversight · Examination of Repairs · Administrative Inspection · Inclining Experiment · In-Service Inspection · Internal Structural Exam · Hull Examination · Damage Survey · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6571718
2 November 2017
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6299682
28 September 2017
Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6336028
8 December 2016
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6054389
5 January 2016
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5790963
05 - Radio Communications › N/A - No Subsystem › Main installation
Issued 17 December 2024
Resolved
Every vessel subject to Part III of Title II of the Communications Act must have a detailed inspection of the radio installed by an FCC-licensed technician in accordance with 80.59, once every five years. Vessel does not have an FCC Safety Radiotelephony Certificate. Vessel restricted to 1000ft from shore. 47 CFR 80.903
Action required: 705 - Other - as specified
Resolved 29 January 2025
Resolution: Provided.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 17 December 2024
Resolved
An EAP program must include the following elements: Supervisory personnel must receive at least 60 minutes of training. No proof of training provided.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2024
Resolved 3 February 2025
Resolution: Provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 December 2024
Resolved
Each ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Life buoys missing retro tape.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2024
Resolved 14 January 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 17 December 2024
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Visual indicators for LAZ pumps not working in auto.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2024
Resolved 13 January 2025
Resolution: Tested sat.
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 November 2017
Resolved
Conduct drills with CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2017
Resolution: Completed drills with CGMI.
Lifesaving › Hand Flares › Quantity
Issued 2 November 2017
Resolved
Provide 04 additional approved flares.
Action required: 705 - Other - as specified
Resolved 15 November 2017
Resolution: Provided all required flares.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 2 November 2017
Resolved
Provide current radio safety certicate.
Action required: 705 - Other - as specified
Resolved 15 November 2017
Resolution: Provided current radio safety certificate.
Communications › Radio Communications › EPIRB
Issued 2 November 2017
Resolved
Provide current epirb registration.
Action required: 705 - Other - as specified
Resolved 13 February 2018
Resolution: Provided current eprib registration.
Documentation › Logs/Records › Drug Test Records
Issued 8 December 2016
Resolved
Provide current drug and alcohol program crew list.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 December 2016
Resolution: Captain provided current crew list.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 5 January 2016
Resolved
Provide EAP hotline numbers and post.
Due 5 February 2016
Resolved 4 February 2016
Resolution: Provided EAP hotline numbers and posted.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 January 2016
Resolved
Provide eyewash and aspirin for first aid kit.
Due 5 February 2016
Resolved 4 February 2016
Resolution: Provided aspirin and eyewash.
Navigation › Piloting/Steering › Marine Charts
Issued 5 January 2016
Resolved
Provide updated chart and light list
Due 5 February 2016
Resolved 4 February 2016
Resolution: Provided updated chart and light list.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 January 2016
Resolved
Prove proper operation of anchor light.
Action required: 705 - Other - as specified
Due 5 February 2016
Resolved 4 February 2016
Resolution: Proved proper operation of the anchor light.
Fire Fighting › Fire Hoses › Number
Issued 5 January 2016
Resolved
Provide 2nd fire hose as required by COI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2016
Resolved 4 February 2016
Resolution: Provided 2nd fire hose.
Fire Fighting › Fire Hoses › Connections
Issued 5 January 2016
Resolved
Ensure fire hoses are always hooked up to hydrant.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 February 2016
Resolution: Hooked up all fire hoses to hydrant.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 5 January 2016
Resolved
Relocate pressure switch from engine room to different location outside of space.
Action required: 705 - Other - as specified
Resolved 4 February 2016