Inspection record

Last inspected 6 July 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDI8735
Flag
UNITED STATES
Maury page id
psix-53224

Documentation record

Registered dimensions (L × B × D)56.0 ft × 19.0 ft × 7.2 ft
Registered tonnagegross 68 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEAWAY BOAT CO · LONG BEACH, CA, UNITED STATES · built 1981
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 25 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it68 - Regulatory (Subpart C or D), Gross Ton
46 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 21 inspections, each with its date, unit and type; 94 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 21

6 July 2026 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8431005
6 May 2025 Deficiency Check · COI Inspection · Re-Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8108096
15 January 2025 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8064253
17 October 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8020738
5 August 2024 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7974825
31 July 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7838606
17 April 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7670361
6 December 2022 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7605937
1 August 2022 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7522481
4 August 2021 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7277318
30 March 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7166576
7 January 2021 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7121238
19 May 2020 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6944670
16 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6835372
15 August 2019 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6781554
7 March 2019 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6638306
10 August 2018 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6548694
1 August 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6495746
12 July 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6196119
10 March 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6102502
22 June 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5915271

Deficiency record · 94

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 July 2026 Resolved
Excessive oil and water was found in bilge indicating a possible leak. Clean engine room of water, oil, and debris for inspection, and identify source of water. Cite: 46 CFR 176.600(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2026
Resolution: Verified bilges free and clear of oil and water.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2025 Resolved
The stbd main engine fuel piping was found corroded and spraying atomized fuel on the engine. Replace fuel line with manufacture approved fuel line.
Action required: 30 - Ship detained
Resolved 6 August 2025
Resolution: Factory fuel line replaced.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 July 2025 Resolved
The engine room bilges were found with excess oil accumulation, creating a fire risk. Remove all oil from engine room bilges.
Action required: 30 - Ship detained
Resolved 6 August 2025
Resolution: Bilges were clean and dry.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2025 Resolved
The port main engine wet exhaust was found to be leaking in the lazarette. Make repairs and prove proper operation of the system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Cracked exaust piping was found and replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 July 2025 Resolved
The generator exhaust cooling is supplied from a pump separate of the engine. Provide a suitable warning device (audible or visual) to indicate failure of the exhaust cooling water.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Alarm installed, tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2025 Resolved
The port main engine belts and pulleys were found exposed and without a guard. Provide machinery guard for rotating machinery parts.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Machinery guard was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2025 Resolved
The stbd main engine fuel return line and piping was found unsupported and prone to vibrations. Properly secure the return fuel hose and piping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Fuel line was properly supported.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 24 July 2025 Resolved
The lzarette stbd side overhead was found with water leaking while the bait tank pump was running. Troubleshoot and repair the ingress of water to the overhead plywood.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Active leaking was stopped, entered special note to address plywood material at next hull exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 July 2025 Resolved
The port main engine was found with splash zone epoxy on the fuel lines, where the return flexible hose makes contact with hard piping fuel line. Run engine under load at high RPM for attending marine inspector to prove integrity of piping / hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Vessel rep cut failed fuel piping and replaced with hose and hose clamps. Required vessel to replace piping with manufacturer approved piping, not flexible hose. Factory hard pipe was replaced in-kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 July 2025 Resolved
The stbd main engine was found with an unsupported hard piped fuel line. The fuel line vibrated excessively while the engine was at higher RPM's. Provide adequate support for fuel line to prevent vibration.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Permanent support provided for fuel line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 July 2025 Resolved
Conduct underway sea trial to prove repairs to both main engines are sufficient.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Sea trial sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 July 2025 Resolved
The generator exhaust piping was found to be leaking in two places in the lazarette. Make permanent repairs to both leaks. 46 CFR 182.310
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Leaks repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2025 Resolved
The stbd galley receptacle was found to be broken and exposing electrical terminals, replace receptacle.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 August 2025
Resolution: Receptacle replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 May 2025 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high-water level in each of the following normally unmanned spaces. All bilge alarms were inoperable due to the disconnection of the panel. Vessel may not operate with passengers for hire until the bilge alarms are tested satisfactory in the presence of a marine inspector. 46CFR182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Observed testing of all bilge alarms. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts, Receptacle outlets of the type providing a grounded pole or a specific direct current polarity must be of a configuration that will not permit improper connection and must be suitably marked and identified. The electrical configurations in the wheelhouse contained exposed wiring, broken junction boxes, was not suitably marked and was not maintained in a manner to prevent electrical hazards. Remove unused wiring, properly dead end all wiring, label electrical components. Install guards to any operational and moving belts. 46CFR180.71
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2025
Resolution: 16JUL2025- Observed guards, All SAT. Electrical wiring in progress 24JUL Wheel house console wiring cleaned up and power strips removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2025 Resolved
Each life jacket must be approved in accordance with 46CFR160. Only 36 of the adult life jackets had working lights and 1 child life jacket had a light installed. 46CFR180.71
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Observed all life jackets and lights. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2025 Resolved
Each ring buoy on a vessel must be approved in accordance with 46CFR160. Vessel had an extra ring buoy that was no longer serviceable, and vessel was told to remove it from the vessel. 46CFR180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Observed ring buoy. All SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 6 May 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI found pipe below the waterline, under the port MDE not properly capped. Cap pipe to prevent flooding and notify local OCMI once complete. 46 CFR 176.830
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Observed caps. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 May 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Exhaust leak located on generator exhaust system. Repair exhaust piping to provide leak free exhaust system from port engine. Notify local OCMI once complete.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Observed exhaust piping. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found on generator. Remove dead end wiring and update electrical plans. Notify local OCMI once complete. 46 CFR 183.200 (c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Observed wiring on generator. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 May 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Fuel filter bowls were full of dirt/water. Clean out fuel bowls and notify local OCMI once complete. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Observed fuel filter bowls. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Generator windings were covered in grease/dust. Clean generators winding in accordance with manufactures instructions. Notify local OCMI once complete. 46 CFR 183.200(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Observed generator winding, all cleaned. All SAT
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2025 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. portable fire extinguishers were past service inspection and not maintained. Service fire extinguishers and replace defective ones. Notify local OCMI once complete. 46CFR176.810
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Observed portable fire extinguishers and servicing. All SAT
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 May 2025 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant. Vessel did not receive a COI and will require a full inspection, in addition to clearing the listed DEFs. Notify local OCMI when vessel is ready for inspection. 46CFR176.800
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2025
Resolution: Issued COI and DEFs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2025 Resolved
The stbd main engine fuel pump and fuel injectors were found to be leaking, make repairs and prove integrity of fuel piping. 46 CFR 182.200-Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2025
Resolution: Repairs were made and engine was tested underway and under load, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 May 2025 Resolved
The stbd main engine was found to be coated with oil and fuel, thoroughly clean the engine after leaks are repaired. 46 CFR 182.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2025
Resolution: Main engine was adequately cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2025 Resolved
The port main engine alternator was found to be unserviceable and with a melted conductor attached, replace alternator and conductor. 46 CFR 183.200- Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2025
Resolution: Alternator and new cable connection were inslalled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 May 2025 Resolved
The bilge system manifold piping has flexible hose installed without double hose clamps, provide double hose clamps for all flexible hoses. 46 CFR 182.710
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Double hose clamps installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 May 2025 Resolved
The stbd main engine turbo was found without heat protection lagging and was smoking oil while engine was running, provide turbo lagging and clean oil from turbo to prevent smoking. 46 CFR 182.200
Action required: 30 - Ship detained
Resolved 6 August 2025
Resolution: Heat insluation installed but turbo is still making oil and smoking and soaking the new insulation. Def not cleared and changed to code 30. Vessel rep cleaned turbo, ran engine under load for an hour, and replaced lagging. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2025 Resolved
The stbd main engine sea strainer was not secured and supported by the hoses attached, properly mount the sea strainer. 46 CFR 182.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2025
Resolution: Strainer was properly mounted.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 May 2025 Resolved
The mast head light was found to inoperable, prove proper operation of the light. 46 CFR 183.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2025
Resolution: Light was illuminated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2025 Resolved
The generator / shore power breakers were found without an interlock device. Provide breakers with proper interlock device to prevent both breakers from being energized simultaneously. 46 CFR 183.390
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 August 2025
Resolution: Interlock installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2025 Resolved
The forepeak bilge switch wiring was found with exposed wire nuts for connectors, provide connections with permanent crimped connectors. 46 CFR 183.340
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Pressure connectors / heat shrink installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2025 Resolved
The engine room bilge alarm wiring was found with exposed wire nuts for connectors. Place wire nuts inside electrical j-box or make connections crimped and sealed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Pressure connector and heat shrink installed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 January 2025 Resolved
Vessel completed dry dock and has not completed IFR / Egress modifications or drills. Vessel is prohibited from carrying overnight passengers or allowing passengers in the bunk rooms until modifications are made and an egress drill is completed.
Action required: 705 - Other - as specified
Resolved 4 June 2025
Resolution: Completed egrees drill. ALL SAT
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 January 2025 Resolved
Remove carpet in all lower / middle bunk spaces for inspection of interior hull side-shell.
Action required: 705 - Other - as specified
Resolved 10 July 2025
Resolution: Carpet removed and interior side shell observed, All SAT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 January 2025 Resolved
Provide lazarette hatch with gasket and retaining chain/cable.
Action required: 705 - Other - as specified
Resolved 10 July 2025
Resolution: Observed gasket and retaining cable, All SAT
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 January 2025 Resolved
Provide j-box in lazarette, port side with cover.
Action required: 705 - Other - as specified
Resolved 10 July 2025
Resolution: Observed cover on J-Box, ALl SAT
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 January 2025 Resolved
Both rudder bearings were found to be wasted and serviceable, replace with new.
Action required: 705 - Other - as specified
Resolved 10 July 2025
Resolution: Observed steering, All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 January 2025 Resolved
Provide 02 sea valves with new handles.
Action required: 705 - Other - as specified
Resolved 10 July 2025
Resolution: Observed new sea valve handles, All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 January 2025 Resolved
Cap unused sea water piping in E/R port side.
Action required: 705 - Other - as specified
Resolved 16 July 2025
Resolution: Observed Caps. All SAT
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 17 October 2024 Resolved
Bunk room lower bunk have carpet on the inside of the side-shell. Remove carpet for inspection of interior hull.
Action required: 705 - Other - as specified
Resolved 10 July 2025
Resolution: Observed lower bunks and carpets remove
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 August 2024 Resolved
Smoke detector in the wheel-house is inoperable. Replace the wheel-house smoke detector and conduct a satisfactory test of all smoke detectors in the presence of a USCG marine inspector. Cite: 46 CFR 181.405(c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 August 2024
Resolution: Witnessed satisfactory test of smoke detectors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 August 2024 Resolved
Electrical equipment exposed to the weather must be watertight. Discovered that the wheel-house emergency batteries are mounted out on deck, exposed to the elements, in a battery box that is not watertight. Move the wheel-house battery box and batteries within the wheel-house or place them in an approved watertight enclosure. Cite: 46 CFR 183.210(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 August 2024
Resolution: Box moved into wheel-house.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 August 2024 Resolved
Hydrostatic release for the Inflatable Buoyant Apparatus (IBA) was found mounted upside down. Reinstall the hydro right side up. Cite: 46 CFR 180.130(a)(1)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 August 2024
Resolution: Reinstalled correctly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 August 2024 Resolved
Improperly Dead-ended wires found in the wheel-house, lazarette, and engine room. Dead-ended wires in the bilge were an especially high hazard since the bilge was oil soaked. Remove all improperly dead-ended wires or properly terminate them with pressure type connectors. Cite: 46 CFR 183.340(g)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 August 2024
Resolution: Wires removed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 August 2024 Resolved
Approximately half of the vessel's bilge alarms were inoperable. Repair/replace the bilge alarms and conduct a satisfactory test of them in the presence of a USCG marine inspector. Cite: 46 CFR 182.520
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 August 2024
Resolution: Witnessed satisfactory test.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 August 2024 Resolved
Excessive oil was identified in the engine room bilge. Clean excessive oily water from bilge and offload it to shore. To be rectified by 22 August 2024. Cite: 46 CFR 182.100 & 46 CFR 176.830
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2024
Resolved 28 August 2024
Resolution: Oil was cleaned out.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 August 2024 Resolved
Identified electrical wires routed low in the engine room bilge. Route electrical wires as high as practicable above the bilge in the engine room. To be rectified by 22 August 2024. Cite: 46 CFR 183.05-50(a)(Old-T) & 46 CFR 183.05-50(b)(Old-T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2024
Resolved 28 August 2024
Resolution: Wires were mounted higher.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 August 2024 Resolved
Discovered an extension cable plugged into an outlet with majority of the cable coiled in a wet sink. Remove the extension cable. Cite: 46 CFR 176.830
Action required: 10 - Deficiency Rectified
Resolved 8 August 2024
Resolution: Corrected on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 August 2024 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel had their annual scheduled for August 5th, 2024, but some unforeseen maintenance caused them to rescheduled. Vessels COI will expire on August 6th, 2024. They have their annual scheduled for August 7th,2024. 46 CFR 176.500 17 - Rectify deficiencies prior to departure
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2024
Resolved 8 August 2024
Resolution: Completed inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2023 Resolved
All machinery be installed and maintained in such a manner as to afford adequate protection against fire explosion, machinery failure, flooding and personnel injury. Replace wasted heat exchanger on STBD engine. Tighten shaft packing on starboard shaft.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2023
Resolution: O/O Replaced wasted heat exchanger
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 July 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 August 2023
Resolution: new employees have been added to DAPI
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 31 July 2023 No resolution recorded
Must submit repair proposal to OCMI and repair wasted wood found in overhead near Engine compartment entrance. Correct at next dry docking.
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 July 2023 Resolved
Pre-engineered must Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Fire boy leads for engine/generator shut-downs were found disconnected from system and switched to over ride function on the bridge. Discrepancy was corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 31 July 2023
Resolution: Fireboy switch was conected back up.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 17 April 2023 Resolved
Prior to the carriage of passengers, Vessel operator must contact [email withheld] to schedule an in service Inspection for the testing of the interconnected fire detection and alarm system.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 April 2023 Resolved
Small passenger vessels that have overnight accommodations for passengers must comply with the requirements in 46 CFR 177.500; construction/arrangement and means of escape. No overnight passengers allowed until vessel meets 46 CFR 177.500.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 11 April 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 August 2022 Resolved
Submit plans for review of the vessel's watch monitoring devices as per the interim rule.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2022
Resolved 31 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 August 2022 Resolved
Refresh vessel name and retro-reflective tape on all lifebuoys.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 31 August 2022
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 4 August 2021 Resolved
Port and Starboard steering bearings worn beyond repair. Bearings should be replaced with approved type bearings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 16 September 2021
Resolution: Owner/Operator replaced both port and starboard bearings.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 4 August 2021 Resolved
Found port main exhaust lagging to be missing. Replace lagging in accordance with manufacturers instruction.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2021
Resolved 5 August 2021
Resolution: missing lagging has been replaced by crew.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 4 August 2021 Resolved
Port main exhaust cooling hose found to be chaffed and worn beyond repair. Hose should be replaced with approved type.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 20 August 2021
Resolution: Exhaust cooling hose has been replaced by owner operator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2021 Resolved
Found dead end wire on positive side of starter. Wire should be removed or connected to appropriate component.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 20 August 2021
Resolution: Pictures submitted by owner. Wire has been removed by owner/operator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2021 Resolved
Wire from engine room fwd knife switch found to have exposed dead end. Dead end wire should be removed or connected to appropriate component.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 20 August 2021
Resolution: Pictures submitted by owner. Wire has been removed by owner/operator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2021 Resolved
Two wires from engine room starboard cable transit found to have exposed dead end. Dead end wires should be removed or connected to appropriate component.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 20 August 2021
Resolution: Pictures submitted by owner. Wires have been removed by owner/operator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2021 Resolved
Two circuits from engine room switchboard distribution panel are installed with 16 gage wire. Circuits are required to be installed with a minimum 14 gage wire.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 16 September 2021
Resolution: Pictures submitted by owner. Wiring has been removed, systems effected was not in use.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2021 Resolved
Main starter batteries found to be missing servicing caps. Approved battery caps should be installed according to manufacturers instructions
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 16 September 2021
Resolution: Crew replaced servicing caps on batteries.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2021 Resolved
Main starter batteries found to have loose terminals contacting the battery box. Terminals should be adjusted to not contact the battery box and connections tightened.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 16 September 2021
Resolution: Terminals have been repositioned by crew.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2021 Resolved
Main starter batteries found to not be secured inside the battery box. Restraints should be installed to prevent batteries from shifting within the battery box.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 16 September 2021
Resolution: blocks have been installed by crew to prevent battery shifting.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2021 Resolved
Unapproved wire found to be installed on deck light on top of the pilot house. Wire should be replaced with approved type.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 5 August 2021
Resolution: Wire has been replaced with approved type by crew.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 4 August 2021 Resolved
Safety radiotelephony certificate has expired. Acquire a new certificate from a licensed inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 5 August 2021
Resolution: New safety radiotelephony certificate was issued to vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 August 2021 Resolved
Fuel vent flame screens were wasted. Flame screens must be replaced with approved 30x30 mesh.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 16 September 2021
Resolution: Flame screens have been replaced by crew.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 August 2021 Resolved
04 life jacket lights were discovered wasted. On Oceans or coastwise route passenger count reduced to 41. Replace water lights with approved to increase passenger count back to 45.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 20 August 2021
Resolution: Owner/Operator has replaced wated lifejacket lights.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 May 2020 Resolved
Provide an adequate means of closing the engine room vents in case of fire emergencies.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2020
Resolved 18 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 May 2020 Resolved
Repair/replace the collision bulkhead bilge isolation valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2020
Resolved 18 June 2020
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 19 May 2020 Resolved
Repair the rudder angle indicator in the lazarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2020
Resolved 18 June 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 May 2020 Resolved
Permanently mount the fish hold pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2020
Resolved 18 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2020 Resolved
Provide a corrosion resistant clip for the ring buoy floating light line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2020
Resolved 18 June 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 May 2020 Resolved
Complete all overdue deficiencies.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 16 January 2020
Resolved 7 January 2021
Resolution: Attended vessel and spot checked accuracy of installation vs submitted plans.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Remove permanently installed extension cord from wheelhouse A/C panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 31 January 2020
Resolution: Extension cord was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Remove dead ended cable and exposed wire nuts from stbd aft locker / tackle rack.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 31 January 2020
Resolution: cable and wire nuts were removed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 October 2019 Resolved
Relocate / remove vent scoop in-way-of emergency escape ladder.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 31 January 2020
Resolution: Vent scoop was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Re-wire all accommodation compartment fans.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 31 January 2020
Resolution: All fans were wired with permanent crimped connectors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Label all circuit breakers with correct loads in all panels.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 31 January 2020
Resolution: Panels were all labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Remove permanently installed extension cord in galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 31 January 2020
Resolution: Extension cord was removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 October 2019 Resolved
Provide galley with non-combustible waste receptacle.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 31 January 2020
Resolution: Vessel rep removed waste receptacle.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Install outlet cover on receptacle wheelhouse port/side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 31 January 2020
Resolution: Outlet cover were installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Install junction box cover on stbd side wheelhouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 31 January 2020
Resolution: Junction box cover was installed.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 22 June 2016 Resolved
Provide one adult and one child PFD.
Condition: Placed in Improper Service
Due 6 July 2016
Resolved 8 July 2016
Resolution: All requiered PFD's provided
Fire Fighting › Remote Fuel Shutoff › General
Issued 22 June 2016 Resolved
Provide emergency fuel valve markings.
Condition: Improper Installation
Due 6 July 2016
Resolved 8 July 2016
Resolution: Proper labeling was provided
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 22 June 2016 Resolved
Prove engine room to be reasonably gas tight in the event of a fire.
Due 6 July 2016
Resolved 8 July 2016
Resolution: A means of obtaining a reasonably gas tight engine room was provided.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 22 June 2016 Resolved
Provide outlet cover in cabinet at the top of berthing ladder.
Condition: Improper Installation
Due 6 July 2016
Resolved 8 July 2016
Resolution: Outlet cover installed
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 22 June 2016 Resolved
Prove proficiency in PIW recovery.
Condition: Invalid
Due 6 July 2016
Resolved 8 July 2016
Resolution: Man Overboard drill was conducted successfully