RELENTLESS

RELENTLESS is a 1981 passenger vessel (inspected). The Coast Guard has recorded 71 inspections since 1985, most recently in July 2026, along with 164 deficiencies — 1 with no resolution recorded —, 1 operational control and 1 casualty investigation in 2014.

Records from 1985 to 2026. Most recent: inspection, 6 July 2026.

Built
1981
Last inspected
6 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI8735
Flag
UNITED STATES
367741610
Maury page id
psix-53224

Inspections, by type

…with no type recorded6
Years with a record 36 calendar years (1985–2026)
The 71 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)56.0 ft × 19.0 ft × 7.2 ft
Registered tonnagegross 68 / net 46
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEAWAY BOAT CO · LONG BEACH, CA, UNITED STATES · built 1981
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 25 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it68 - Regulatory (Subpart C or D), Gross Ton
46 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDR3549MMSI 367741610 · active · compulsorily equipped · granted 1 August 2026, expires 1 August 2036
WDI8735MMSI 367741610 · expired · compulsorily equipped · granted 17 June 2016, cancelled 25 July 2026
WDG7116MMSI 367564020 · expired · compulsorily equipped · granted 26 February 2013, cancelled 29 April 2023
WDB5621MMSI 369198000 · expired · compulsorily equipped · granted 31 October 2003, cancelled 4 January 2014
WCA5378MMSI 366785000 · expired · compulsorily equipped · granted 12 June 1998, cancelled 6 December 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 71

6 July 2026 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8431005
6 May 2025 Deficiency Check · COI Inspection · Re-Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8108096
15 January 2025 Hull Examination · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8064253
17 October 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8020738
5 August 2024 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7974825
31 July 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7838606
17 April 2023 Administrative Inspection · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7670361
6 December 2022 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7605937
1 August 2022 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7522481
4 August 2021 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7277318
30 March 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7166576
7 January 2021 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7121238
19 May 2020 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6944670
16 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6835372
15 August 2019 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6781554
7 March 2019 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6638306
10 August 2018 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6548694
1 August 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6495746
12 July 2017 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6196119
10 March 2017 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6102502
22 June 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5915271
24 March 2010 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3702035
12 May 2008 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3189902
21 January 2008 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3111807
21 May 2007 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2925159
30 May 2006 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2644768
21 November 2005 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2527975
3 June 2004 Hull Examination · Deficiency Check · Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1952295
30 September 2003 Drydock Extension · Internal Structural Exam
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1917921
28 August 2003 Examination of Repairs
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1918624
29 July 2003 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1860429
10 March 2003 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1755434
28 May 2002 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1620202
2 October 2001 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1362466
13 June 2001 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1362312
12 January 2001 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1444445
13 June 2000 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1393458
25 October 1999 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1466085
3 June 1999 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1457658
9 April 1999 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1124558
10 June 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1375413
31 October 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1390622
26 June 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1314
26 June 1997 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1386037
3 June 1997 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1465917
4 June 1996 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1355839
3 January 1996 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 877056
15 December 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1438383
6 June 1995 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1184483
26 May 1994 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1170602
9 December 1993 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1358279
8 June 1993 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 843477
21 July 1992 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 946147
11 June 1992 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1267419
26 May 1992 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1265951
17 June 1991 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1043441
19 November 1990 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1296162
5 July 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 922182
18 June 1990 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 922479
2 November 1989 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 886832
6 July 1989 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1339033
16 June 1989 Examination of Repairs · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1194637
25 October 1988 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1199431
24 June 1988 Deficiency Check · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1204551
23 July 1987 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1024888
25 June 1987 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1008654
16 April 1987 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1308918
12 June 1986 Deficiency Check · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 989988
21 October 1985 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 990979
4 October 1985 Credit Drydock
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1294458
27 June 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 987666

Deficiency record · 164

99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 July 2026 Resolved
Excessive oil and water was found in bilge indicating a possible leak. Clean engine room of water, oil, and debris for inspection, and identify source of water. Cite: 46 CFR 176.600(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 August 2026
Resolution: Verified bilges free and clear of oil and water.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2025 Resolved
The stbd main engine fuel piping was found corroded and spraying atomized fuel on the engine. Replace fuel line with manufacture approved fuel line.
Action required: 30 - Ship detained
Resolved 6 August 2025
Resolution: Factory fuel line replaced.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 July 2025 Resolved
The engine room bilges were found with excess oil accumulation, creating a fire risk. Remove all oil from engine room bilges.
Action required: 30 - Ship detained
Resolved 6 August 2025
Resolution: Bilges were clean and dry.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2025 Resolved
The port main engine wet exhaust was found to be leaking in the lazarette. Make repairs and prove proper operation of the system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Cracked exaust piping was found and replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 July 2025 Resolved
The generator exhaust cooling is supplied from a pump separate of the engine. Provide a suitable warning device (audible or visual) to indicate failure of the exhaust cooling water.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Alarm installed, tested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2025 Resolved
The port main engine belts and pulleys were found exposed and without a guard. Provide machinery guard for rotating machinery parts.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Machinery guard was installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 July 2025 Resolved
The stbd main engine fuel return line and piping was found unsupported and prone to vibrations. Properly secure the return fuel hose and piping.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Fuel line was properly supported.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 24 July 2025 Resolved
The lzarette stbd side overhead was found with water leaking while the bait tank pump was running. Troubleshoot and repair the ingress of water to the overhead plywood.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Active leaking was stopped, entered special note to address plywood material at next hull exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 July 2025 Resolved
The port main engine was found with splash zone epoxy on the fuel lines, where the return flexible hose makes contact with hard piping fuel line. Run engine under load at high RPM for attending marine inspector to prove integrity of piping / hose.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Vessel rep cut failed fuel piping and replaced with hose and hose clamps. Required vessel to replace piping with manufacturer approved piping, not flexible hose. Factory hard pipe was replaced in-kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 July 2025 Resolved
The stbd main engine was found with an unsupported hard piped fuel line. The fuel line vibrated excessively while the engine was at higher RPM's. Provide adequate support for fuel line to prevent vibration.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Permanent support provided for fuel line.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 July 2025 Resolved
Conduct underway sea trial to prove repairs to both main engines are sufficient.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Sea trial sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 16 July 2025 Resolved
The generator exhaust piping was found to be leaking in two places in the lazarette. Make permanent repairs to both leaks. 46 CFR 182.310
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Leaks repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 July 2025 Resolved
The stbd galley receptacle was found to be broken and exposing electrical terminals, replace receptacle.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 August 2025
Resolution: Receptacle replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 May 2025 Resolved
A visual and audible alarm must be provided at the operating station to indicate a high-water level in each of the following normally unmanned spaces. All bilge alarms were inoperable due to the disconnection of the panel. Vessel may not operate with passengers for hire until the bilge alarms are tested satisfactory in the presence of a marine inspector. 46CFR182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Observed testing of all bilge alarms. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts, Receptacle outlets of the type providing a grounded pole or a specific direct current polarity must be of a configuration that will not permit improper connection and must be suitably marked and identified. The electrical configurations in the wheelhouse contained exposed wiring, broken junction boxes, was not suitably marked and was not maintained in a manner to prevent electrical hazards. Remove unused wiring, properly dead end all wiring, label electrical components. Install guards to any operational and moving belts. 46CFR180.71
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2025
Resolution: 16JUL2025- Observed guards, All SAT. Electrical wiring in progress 24JUL Wheel house console wiring cleaned up and power strips removed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2025 Resolved
Each life jacket must be approved in accordance with 46CFR160. Only 36 of the adult life jackets had working lights and 1 child life jacket had a light installed. 46CFR180.71
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Observed all life jackets and lights. All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2025 Resolved
Each ring buoy on a vessel must be approved in accordance with 46CFR160. Vessel had an extra ring buoy that was no longer serviceable, and vessel was told to remove it from the vessel. 46CFR180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Observed ring buoy. All SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 6 May 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. MI found pipe below the waterline, under the port MDE not properly capped. Cap pipe to prevent flooding and notify local OCMI once complete. 46 CFR 176.830
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Observed caps. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 May 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Exhaust leak located on generator exhaust system. Repair exhaust piping to provide leak free exhaust system from port engine. Notify local OCMI once complete.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Observed exhaust piping. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found on generator. Remove dead end wiring and update electrical plans. Notify local OCMI once complete. 46 CFR 183.200 (c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Observed wiring on generator. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 May 2025 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Fuel filter bowls were full of dirt/water. Clean out fuel bowls and notify local OCMI once complete. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Observed fuel filter bowls. All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2025 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Generator windings were covered in grease/dust. Clean generators winding in accordance with manufactures instructions. Notify local OCMI once complete. 46 CFR 183.200(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Observed generator winding, all cleaned. All SAT
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 May 2025 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment. portable fire extinguishers were past service inspection and not maintained. Service fire extinguishers and replace defective ones. Notify local OCMI once complete. 46CFR176.810
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 July 2025
Resolution: Observed portable fire extinguishers and servicing. All SAT
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 May 2025 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant. Vessel did not receive a COI and will require a full inspection, in addition to clearing the listed DEFs. Notify local OCMI when vessel is ready for inspection. 46CFR176.800
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2025
Resolution: Issued COI and DEFs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2025 Resolved
The stbd main engine fuel pump and fuel injectors were found to be leaking, make repairs and prove integrity of fuel piping. 46 CFR 182.200-Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2025
Resolution: Repairs were made and engine was tested underway and under load, all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 May 2025 Resolved
The stbd main engine was found to be coated with oil and fuel, thoroughly clean the engine after leaks are repaired. 46 CFR 182.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2025
Resolution: Main engine was adequately cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2025 Resolved
The port main engine alternator was found to be unserviceable and with a melted conductor attached, replace alternator and conductor. 46 CFR 183.200- Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2025
Resolution: Alternator and new cable connection were inslalled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 May 2025 Resolved
The bilge system manifold piping has flexible hose installed without double hose clamps, provide double hose clamps for all flexible hoses. 46 CFR 182.710
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Double hose clamps installed.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 6 May 2025 Resolved
The stbd main engine turbo was found without heat protection lagging and was smoking oil while engine was running, provide turbo lagging and clean oil from turbo to prevent smoking. 46 CFR 182.200
Action required: 30 - Ship detained
Resolved 6 August 2025
Resolution: Heat insluation installed but turbo is still making oil and smoking and soaking the new insulation. Def not cleared and changed to code 30. Vessel rep cleaned turbo, ran engine under load for an hour, and replaced lagging. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 May 2025 Resolved
The stbd main engine sea strainer was not secured and supported by the hoses attached, properly mount the sea strainer. 46 CFR 182.200
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2025
Resolution: Strainer was properly mounted.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 May 2025 Resolved
The mast head light was found to inoperable, prove proper operation of the light. 46 CFR 183.420
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2025
Resolution: Light was illuminated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 May 2025 Resolved
The generator / shore power breakers were found without an interlock device. Provide breakers with proper interlock device to prevent both breakers from being energized simultaneously. 46 CFR 183.390
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 August 2025
Resolution: Interlock installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2025 Resolved
The forepeak bilge switch wiring was found with exposed wire nuts for connectors, provide connections with permanent crimped connectors. 46 CFR 183.340
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Pressure connectors / heat shrink installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2025 Resolved
The engine room bilge alarm wiring was found with exposed wire nuts for connectors. Place wire nuts inside electrical j-box or make connections crimped and sealed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2025
Resolution: Pressure connector and heat shrink installed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 15 January 2025 Resolved
Vessel completed dry dock and has not completed IFR / Egress modifications or drills. Vessel is prohibited from carrying overnight passengers or allowing passengers in the bunk rooms until modifications are made and an egress drill is completed.
Action required: 705 - Other - as specified
Resolved 4 June 2025
Resolution: Completed egrees drill. ALL SAT
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 January 2025 Resolved
Remove carpet in all lower / middle bunk spaces for inspection of interior hull side-shell.
Action required: 705 - Other - as specified
Resolved 10 July 2025
Resolution: Carpet removed and interior side shell observed, All SAT
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 January 2025 Resolved
Provide lazarette hatch with gasket and retaining chain/cable.
Action required: 705 - Other - as specified
Resolved 10 July 2025
Resolution: Observed gasket and retaining cable, All SAT
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 January 2025 Resolved
Provide j-box in lazarette, port side with cover.
Action required: 705 - Other - as specified
Resolved 10 July 2025
Resolution: Observed cover on J-Box, ALl SAT
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 January 2025 Resolved
Both rudder bearings were found to be wasted and serviceable, replace with new.
Action required: 705 - Other - as specified
Resolved 10 July 2025
Resolution: Observed steering, All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 January 2025 Resolved
Provide 02 sea valves with new handles.
Action required: 705 - Other - as specified
Resolved 10 July 2025
Resolution: Observed new sea valve handles, All SAT
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 15 January 2025 Resolved
Cap unused sea water piping in E/R port side.
Action required: 705 - Other - as specified
Resolved 16 July 2025
Resolution: Observed Caps. All SAT
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 17 October 2024 Resolved
Bunk room lower bunk have carpet on the inside of the side-shell. Remove carpet for inspection of interior hull.
Action required: 705 - Other - as specified
Resolved 10 July 2025
Resolution: Observed lower bunks and carpets remove
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 August 2024 Resolved
Smoke detector in the wheel-house is inoperable. Replace the wheel-house smoke detector and conduct a satisfactory test of all smoke detectors in the presence of a USCG marine inspector. Cite: 46 CFR 181.405(c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 13 August 2024
Resolution: Witnessed satisfactory test of smoke detectors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 August 2024 Resolved
Electrical equipment exposed to the weather must be watertight. Discovered that the wheel-house emergency batteries are mounted out on deck, exposed to the elements, in a battery box that is not watertight. Move the wheel-house battery box and batteries within the wheel-house or place them in an approved watertight enclosure. Cite: 46 CFR 183.210(b)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 14 August 2024
Resolution: Box moved into wheel-house.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 8 August 2024 Resolved
Hydrostatic release for the Inflatable Buoyant Apparatus (IBA) was found mounted upside down. Reinstall the hydro right side up. Cite: 46 CFR 180.130(a)(1)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 August 2024
Resolution: Reinstalled correctly.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 August 2024 Resolved
Improperly Dead-ended wires found in the wheel-house, lazarette, and engine room. Dead-ended wires in the bilge were an especially high hazard since the bilge was oil soaked. Remove all improperly dead-ended wires or properly terminate them with pressure type connectors. Cite: 46 CFR 183.340(g)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 August 2024
Resolution: Wires removed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 August 2024 Resolved
Approximately half of the vessel's bilge alarms were inoperable. Repair/replace the bilge alarms and conduct a satisfactory test of them in the presence of a USCG marine inspector. Cite: 46 CFR 182.520
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 August 2024
Resolution: Witnessed satisfactory test.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 August 2024 Resolved
Excessive oil was identified in the engine room bilge. Clean excessive oily water from bilge and offload it to shore. To be rectified by 22 August 2024. Cite: 46 CFR 182.100 & 46 CFR 176.830
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2024
Resolved 28 August 2024
Resolution: Oil was cleaned out.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 August 2024 Resolved
Identified electrical wires routed low in the engine room bilge. Route electrical wires as high as practicable above the bilge in the engine room. To be rectified by 22 August 2024. Cite: 46 CFR 183.05-50(a)(Old-T) & 46 CFR 183.05-50(b)(Old-T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 August 2024
Resolved 28 August 2024
Resolution: Wires were mounted higher.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 August 2024 Resolved
Discovered an extension cable plugged into an outlet with majority of the cable coiled in a wet sink. Remove the extension cable. Cite: 46 CFR 176.830
Action required: 10 - Deficiency Rectified
Resolved 8 August 2024
Resolution: Corrected on the spot.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 August 2024 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. Vessel had their annual scheduled for August 5th, 2024, but some unforeseen maintenance caused them to rescheduled. Vessels COI will expire on August 6th, 2024. They have their annual scheduled for August 7th,2024. 46 CFR 176.500 17 - Rectify deficiencies prior to departure
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2024
Resolved 8 August 2024
Resolution: Completed inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2023 Resolved
All machinery be installed and maintained in such a manner as to afford adequate protection against fire explosion, machinery failure, flooding and personnel injury. Replace wasted heat exchanger on STBD engine. Tighten shaft packing on starboard shaft.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 31 July 2023
Resolution: O/O Replaced wasted heat exchanger
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 July 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 28 August 2023
Resolution: new employees have been added to DAPI
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 31 July 2023 No resolution recorded
Must submit repair proposal to OCMI and repair wasted wood found in overhead near Engine compartment entrance. Correct at next dry docking.
Action required: 705 - Other - as specified
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 July 2023 Resolved
Pre-engineered must Automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. Fire boy leads for engine/generator shut-downs were found disconnected from system and switched to over ride function on the bridge. Discrepancy was corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 31 July 2023
Resolution: Fireboy switch was conected back up.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 17 April 2023 Resolved
Prior to the carriage of passengers, Vessel operator must contact [email withheld] to schedule an in service Inspection for the testing of the interconnected fire detection and alarm system.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 April 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 April 2023 Resolved
Small passenger vessels that have overnight accommodations for passengers must comply with the requirements in 46 CFR 177.500; construction/arrangement and means of escape. No overnight passengers allowed until vessel meets 46 CFR 177.500.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 11 April 2024
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 August 2022 Resolved
Submit plans for review of the vessel's watch monitoring devices as per the interim rule.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2022
Resolved 31 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 August 2022 Resolved
Refresh vessel name and retro-reflective tape on all lifebuoys.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 31 August 2022
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 4 August 2021 Resolved
Port and Starboard steering bearings worn beyond repair. Bearings should be replaced with approved type bearings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 16 September 2021
Resolution: Owner/Operator replaced both port and starboard bearings.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 4 August 2021 Resolved
Found port main exhaust lagging to be missing. Replace lagging in accordance with manufacturers instruction.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 August 2021
Resolved 5 August 2021
Resolution: missing lagging has been replaced by crew.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 4 August 2021 Resolved
Port main exhaust cooling hose found to be chaffed and worn beyond repair. Hose should be replaced with approved type.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 20 August 2021
Resolution: Exhaust cooling hose has been replaced by owner operator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2021 Resolved
Found dead end wire on positive side of starter. Wire should be removed or connected to appropriate component.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 20 August 2021
Resolution: Pictures submitted by owner. Wire has been removed by owner/operator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2021 Resolved
Wire from engine room fwd knife switch found to have exposed dead end. Dead end wire should be removed or connected to appropriate component.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 20 August 2021
Resolution: Pictures submitted by owner. Wire has been removed by owner/operator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2021 Resolved
Two wires from engine room starboard cable transit found to have exposed dead end. Dead end wires should be removed or connected to appropriate component.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 20 August 2021
Resolution: Pictures submitted by owner. Wires have been removed by owner/operator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2021 Resolved
Two circuits from engine room switchboard distribution panel are installed with 16 gage wire. Circuits are required to be installed with a minimum 14 gage wire.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 16 September 2021
Resolution: Pictures submitted by owner. Wiring has been removed, systems effected was not in use.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2021 Resolved
Main starter batteries found to be missing servicing caps. Approved battery caps should be installed according to manufacturers instructions
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 16 September 2021
Resolution: Crew replaced servicing caps on batteries.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2021 Resolved
Main starter batteries found to have loose terminals contacting the battery box. Terminals should be adjusted to not contact the battery box and connections tightened.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 16 September 2021
Resolution: Terminals have been repositioned by crew.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2021 Resolved
Main starter batteries found to not be secured inside the battery box. Restraints should be installed to prevent batteries from shifting within the battery box.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 16 September 2021
Resolution: blocks have been installed by crew to prevent battery shifting.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 August 2021 Resolved
Unapproved wire found to be installed on deck light on top of the pilot house. Wire should be replaced with approved type.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 5 August 2021
Resolution: Wire has been replaced with approved type by crew.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 4 August 2021 Resolved
Safety radiotelephony certificate has expired. Acquire a new certificate from a licensed inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 5 August 2021
Resolution: New safety radiotelephony certificate was issued to vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 August 2021 Resolved
Fuel vent flame screens were wasted. Flame screens must be replaced with approved 30x30 mesh.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 16 September 2021
Resolution: Flame screens have been replaced by crew.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 August 2021 Resolved
04 life jacket lights were discovered wasted. On Oceans or coastwise route passenger count reduced to 41. Replace water lights with approved to increase passenger count back to 45.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 August 2021
Resolved 20 August 2021
Resolution: Owner/Operator has replaced wated lifejacket lights.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 May 2020 Resolved
Provide an adequate means of closing the engine room vents in case of fire emergencies.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2020
Resolved 18 June 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 May 2020 Resolved
Repair/replace the collision bulkhead bilge isolation valve.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2020
Resolved 18 June 2020
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 19 May 2020 Resolved
Repair the rudder angle indicator in the lazarette.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2020
Resolved 18 June 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 May 2020 Resolved
Permanently mount the fish hold pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2020
Resolved 18 June 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2020 Resolved
Provide a corrosion resistant clip for the ring buoy floating light line.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2020
Resolved 18 June 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 May 2020 Resolved
Complete all overdue deficiencies.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 June 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 705 - Other - as specified
Due 16 January 2020
Resolved 7 January 2021
Resolution: Attended vessel and spot checked accuracy of installation vs submitted plans.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Remove permanently installed extension cord from wheelhouse A/C panel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 31 January 2020
Resolution: Extension cord was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Remove dead ended cable and exposed wire nuts from stbd aft locker / tackle rack.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 31 January 2020
Resolution: cable and wire nuts were removed.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 16 October 2019 Resolved
Relocate / remove vent scoop in-way-of emergency escape ladder.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 31 January 2020
Resolution: Vent scoop was removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Re-wire all accommodation compartment fans.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 31 January 2020
Resolution: All fans were wired with permanent crimped connectors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Label all circuit breakers with correct loads in all panels.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 31 January 2020
Resolution: Panels were all labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Remove permanently installed extension cord in galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 31 January 2020
Resolution: Extension cord was removed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 October 2019 Resolved
Provide galley with non-combustible waste receptacle.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 31 January 2020
Resolution: Vessel rep removed waste receptacle.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Install outlet cover on receptacle wheelhouse port/side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 31 January 2020
Resolution: Outlet cover were installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Install junction box cover on stbd side wheelhouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 November 2019
Resolved 31 January 2020
Resolution: Junction box cover was installed.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 22 June 2016 Resolved
Provide one adult and one child PFD.
Condition: Placed in Improper Service
Due 6 July 2016
Resolved 8 July 2016
Resolution: All requiered PFD's provided
Fire Fighting › Remote Fuel Shutoff › General
Issued 22 June 2016 Resolved
Provide emergency fuel valve markings.
Condition: Improper Installation
Due 6 July 2016
Resolved 8 July 2016
Resolution: Proper labeling was provided
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 22 June 2016 Resolved
Prove engine room to be reasonably gas tight in the event of a fire.
Due 6 July 2016
Resolved 8 July 2016
Resolution: A means of obtaining a reasonably gas tight engine room was provided.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 22 June 2016 Resolved
Provide outlet cover in cabinet at the top of berthing ladder.
Condition: Improper Installation
Due 6 July 2016
Resolved 8 July 2016
Resolution: Outlet cover installed
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 22 June 2016 Resolved
Prove proficiency in PIW recovery.
Condition: Invalid
Due 6 July 2016
Resolved 8 July 2016
Resolution: Man Overboard drill was conducted successfully
Fire Fighting › Fire Bucket › Availability
Issued 12 May 2008 Resolved
Provide three fire buckets with lanyards (at least 2.5 gallons each).
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 4 June 2008
Navigation › Piloting/Steering › Marine Charts
Issued 12 May 2008 Resolved
Provide current chart (18773) of SD Bay and approach.
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 4 June 2008
Documentation › Certificates/Documents › Stability Letter
Issued 12 May 2008 Resolved
Post Stability Letter on bridge.
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 4 June 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 May 2008 Resolved
Provide high-water bilge alarm (audible and visual) for forepeak due to wood construction and 46 CFR 182.530(b).
Action required: 705 - Other - as specified
Due 30 May 2008
Resolved 4 June 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 21 May 2007 Resolved
Provide proof of enrollment in random drug testing program for entire crew.
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 22 May 2007
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 21 May 2007 Resolved
Install SSB radio with Digital Selective Calling (DSC) capability. Vessel restricted to no more than 100nm offshore until provided.
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 28 June 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 May 2007 Resolved
Repair masthead light. Vessel restricted to daylight ops only until corrected.
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 22 May 2007
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 21 May 2007 Resolved
Provide (1) additional adult Type-1 PFD. Vessel restricted to no more than 29 total persons until provided.
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 29 May 2007
Lifesaving › Lifeboat Equipment › Life Saving Signals Card
Issued 21 May 2007 Resolved
Provide and post PFD donning placard.
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 22 May 2007
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 21 May 2007 Resolved
Replace damaged shore-tie cable.
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 28 June 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 21 May 2007 Resolved
Provide additional B-II portable fire extinguisher and smoke detector is galley to meet CID Policy Letter #20.
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 29 May 2007
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 21 May 2007 Resolved
Clean grease build-up in galley hood ducting.
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 29 May 2007
Navigation › Piloting/Steering › Marine Charts
Issued 21 May 2007 Resolved
Provide current San Diego Bay chart.
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 28 June 2007
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 21 May 2007 Resolved
Provide the following to complete first aid kit: eye wash solution, ammonia inhalants, and aspirin.
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 22 May 2007
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 21 May 2007 Resolved
Provide three (3) fire buckets at least 2.5 gallons each, with attached lanyard, and marked "fire bucket."
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 22 May 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 May 2007 Resolved
Provide metal supports for wiring in E/R and laz at least every 24 inches.
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 28 June 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 21 May 2007 Resolved
Conduct and log required drills (MOB, fire, etc) and test and log required EPIRB tests.
Action required: 705 - Other - as specified
Due 21 June 2007
Resolved 28 June 2007
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 30 May 2006 Resolved
Produce current drug program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 June 2006
Resolution: Ownerproduced drug program records.
Documentation › Certificates/Documents › Stability Letter
Issued 30 May 2006 Resolved
Provide current or original documentation for vsl stability letter.
Action required: 705 - Other - as specified
Due 30 August 2006
Resolved 2 November 2006
Resolution: Stability test was given on this date
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 30 May 2006 Resolved
Provide original mate's license. No over 12 hours operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 November 2006
Resolution: Mates license was valid
Lifesaving › Lifebuoys › Serviceable
Issued 30 May 2006 Resolved
Replace 2 ring buoys. Port side and bow.
Due 31 May 2006
Resolved 30 May 2006
Resolution: Owner purchased 2 ring buoys
Navigation › Piloting/Steering › Marine Charts
Issued 30 May 2006 Resolved
Produce current chart
Due 30 June 2006
Resolved 30 May 2006
Resolution: Owner purchased new chart.
Communications › Radio Communications › Satellite Communications Capability
Issued 30 May 2006 Resolved
Renew Nav-tex print out paper. Limited to 100 miles from baseline.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 31 May 2006
Resolution: Owner purchased new paper.
Engineering › Shafting/Propeller Arrangements › Strut
Issued 21 November 2005 Resolved
Propose and affect permanent repair to port intermediate strut in way of crack.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 December 2005
Stability › Watertight Integrity › General
Issued 21 November 2005 Resolved
Install new gasket in lazarette watertight hatch.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2006
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 21 November 2005 Resolved
Provide captive chain for lazarette hatch.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 February 2006
Communications › Radio Communications › EPIRB
Issued 3 June 2004 Resolved
Provide current registration for EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2004
Resolved 4 June 2004
Resolution: Provided current registration.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 3 December 2003 Resolved
Provide modular smoke detector for every overnignt accomodation space.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 July 2004
Resolved 4 June 2004
Resolution: New detectors installed
Electrical › Electric Generation Source (service)
Issued 10 March 2003 Resolved
Repair arcing at generator starting battery. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Due 11 April 2003
Resolved 24 July 2003
Resolution: Operator installed new battery.
Electrical › Electrical Distribution System (service)
Issued 10 March 2003 Resolved
Install metallic cable clamps where needed throughout the vessel. LEGACY COMPONENT DESC: Cable
Condition: Placed in Improper Service
Due 11 April 2003
Resolved 24 July 2003
Resolution: Operator installed required clamps.
Engineering › Steering Gear System
Issued 10 March 2003 Resolved
shorten port steering stop chain to provide for effective stopping of ram over travel. LEGACY COMPONENT DESC: Chain
Condition: Improper Installation
Due 11 April 2003
Resolved 24 July 2003
Resolution: Operator reduced the length of rudder stop chains.
Lifesaving › Lifebuoys
Issued 10 March 2003 Resolved
properly install retro tape on ringbuoys. LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Improper Installation
Due 11 April 2003
Resolved 24 July 2003
Resolution: tape on lifebuoy was renewed.
Accommodation/Occupational Safety › Medical/First Aid
Issued 10 March 2003 Resolved
provide updated items in first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 11 April 2003
Resolved 24 July 2003
Resolution: Adequate first aid kit provided.
Documentation › Manuals/Policy Documentation
Issued 10 March 2003 Resolved
provide paper copies of charts and publications.
Condition: Unknown
Due 8 May 2003
Resolved 31 July 2003
Communications › Radio Communications
Issued 28 May 2002 Resolved
Provide valid FCC operators license. LEGACY COMPONENT DESC: VFH Radiotelephone
Condition: Unknown
Due 14 June 2002
Resolved 28 May 2002
Operations/Management › Navigation Safety
Issued 28 May 2002 Resolved
Install operable compass light. LEGACY COMPONENT DESC: Compass Light
Condition: Improper Installation
Due 14 June 2002
Resolved 28 May 2002
Electrical › Lighting (service)
Issued 28 May 2002 Resolved
Install globe on light fixure in engine room LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Due 14 June 2002
Resolved 28 May 2002
Electrical › Electrical Distribution System (service)
Issued 28 May 2002 Resolved
Install blank front on power panel in engine room aft, starb side. LEGACY COMPONENT DESC: Panelboard
Condition: Improper Installation
Due 14 June 2002
Resolved 28 May 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 28 May 2002 Resolved
Repair broken hanger on starb exhaust pipe in laz. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Due 14 June 2002
Resolved 28 May 2002
Stability › Watertight Integrity
Issued 28 May 2002 Resolved
Seal bulkhead penetrations on laz/eng. rm bulkhead port side. LEGACY COMPONENT DESC: Bulkhead penetration
Condition: Improper Installation
Due 14 June 2002
Resolved 28 May 2002
Construction/Loadline
Issued 13 June 2000 Resolved
Provide securing device and captive chain for engineroom hatch.
Condition: Unknown
Due 22 June 2000
Resolved 22 June 2000
Engineering
Issued 13 June 2000 Resolved
Provide flame protection for remote fuel cutoff for center tank.
Condition: Unknown
Due 22 June 2000
Resolved 22 June 2000
Lifesaving
Issued 13 June 2000 Resolved
provide complete coast guard approved first aid kit or equivalent.
Condition: Unknown
Due 22 June 2000
Resolved 22 June 2000
Unknown
Issued 13 June 2000 Resolved
Provide galley vent screen.
Condition: Unknown
Due 22 June 2000
Resolved 22 June 2000
Construction/Loadline
Issued 26 June 1997 Resolved
CROP OUT AND RENEW IN LIKE KIND AS ORIGINAL A 7"X3"X1.5" HOLED THROUGH WITHAPPROXIMATELY 15" DIAGONAL FRACTURING (SLANTING DOWN FORWARD FROM THE HOLE IN WAY OF PORT MIDSHIP APPROXIMATELY 6" FROM THE MAINDECK (ENGINE ROOM). REPAIR TO BE CONDUCTED PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 3 July 1997
Resolved 3 July 1997
Documentation
Issued 4 June 1996 Resolved
POST VALID STABILITY LETTER.
Condition: Unknown
Due 21 June 1996
Resolved 25 June 1996
Documentation
Issued 4 June 1996 Resolved
PROVIDE PROOF OF APPROVED RANDOM DRUG PROGRAM.
Condition: Unknown
Due 21 June 1996
Resolved 25 June 1996
Documentation
Issued 4 June 1996 Resolved
PROVIDE SHIP'S LOG.
Condition: Unknown
Due 21 June 1996
Resolved 25 June 1996
Documentation
Issued 4 June 1996 Resolved
PROVIDE TRASH DISPOSAL LOG.
Condition: Unknown
Due 21 June 1996
Resolved 25 June 1996
Navigation
Issued 4 June 1996 Resolved
UPDATE ALL LOCAL CHARTS AND PUBLICATIONS THROUGHT THE LASTEST ISSUE OF LOCAL NOTICE TO MARINERS.
Condition: Unknown
Due 21 June 1996
Resolved 25 June 1996
Electrical
Issued 15 December 1995 Resolved
Replace all AWG16/3 SJ electrical wire cable in lazarrette with wire which meets the standards in 46 CFR Part 183.
Condition: Unknown
Due 15 December 1995
Resolved 15 December 1995
Construction/Loadline
Issued 8 June 1993 Resolved
PROVIDE CHAINS FOR LAZARETTE AND FORWARD PEAK FLUSH DECK HATCHES.
Condition: Unknown
Due 8 July 1993
Resolved 8 July 1993
Navigation
Issued 8 June 1993 Resolved
RENEW BEARINGS ON BOTH RUDDER POSTS.
Condition: Unknown
Due 8 July 1993
Resolved 8 July 1993
Lifesaving
Issued 8 June 1993 Resolved
PROVIDE READILY ACCESSIBLE STOWAGE FOR ADDITIONAL 20 ADULT LIFEJACKETS USEDFOR LIMITED COASTWISE ROUTE.
Condition: Unknown
Due 8 July 1993
Resolved 8 July 1993
Construction/Loadline
Issued 8 June 1993 Resolved
CLEAN AND TREAT DRYROT IN WAY OF THE ENGINEROOM VENTILATION FANS
Condition: Unknown
Due 8 July 1993
Resolved 8 July 1993
Lifesaving
Issued 8 June 1993 Resolved
PROPERLY MARK CHILD LIFEJACKET STOWAGE AREA FOR 5 CHILD SIZE LIFEJACKETS.
Condition: Unknown
Due 8 July 1993
Resolved 8 July 1993
Electrical
Issued 11 June 1992 Resolved
PROVIDE BLANKS FOR OPEN HOLES IN CIRCUIT BREAKER PANEL IN THE ENGINE ROOM.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Electrical
Issued 11 June 1992 Resolved
PROVIDE AND INSTALL A GUARD OVER MOTOR DRIVEN FAN UNIT IN PILOT HOUSE.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Lifesaving
Issued 11 June 1992 Resolved
PROVIDE 01 ADDITIONAL CG APPROVED TYPE ONE ADULT LIFE JACKET PRIOR TO CARRYING MORE THAN 49 ADULTS.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Lifesaving
Issued 11 June 1992 Resolved
PROVIDE CLASS "A" EPIRB MANUFACTURED ON OR AFTER 01 OCTOBER 1988.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Electrical
Issued 11 June 1992 Resolved
PROVIDE A PROPERLY MOUNTED BREAKER FOR BATTERY ON PILOT HOUSE DECK.
Condition: Unknown
Due 11 June 1992
Resolved 11 June 1992
Navigation
Issued 18 June 1990 Resolved
PROVIDE AN UP TO DATE MAGNETIC COMPASS DEVIATION CARD.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Engineering
Issued 24 June 1988 Resolved
REPAIR PORT MAIN ENGINE TACHOMETER IN THE WHEELHOUSE.
Condition: Unknown
Due 24 June 1988
Resolved 24 June 1988
Construction/Loadline
Issued 24 June 1988 Resolved
INSTALL A VALVE AT THE HULL ON THE BAIT TANK OVERBOARD DISCHARGE.
Condition: Unknown
Due 24 June 1988
Resolved 24 June 1988
Electrical
Issued 24 June 1988 Resolved
INSTALL A FLAME SHIELD ON GENERATOR FUEL FILTER.
Condition: Unknown
Due 24 June 1988
Resolved 24 June 1988
Documentation
Issued 24 June 1988 Resolved
PROVIDE A CURRENT COMMUNICATIONS ACT SAFTEY RADIOTELEPHONY CERTIFICATE AND STATION LICENSE.
Condition: Unknown
Due 24 June 1988
Resolved 24 June 1988
Construction/Loadline
Issued 23 July 1987 Resolved
REPAIR APPROX. 10' X 8' DAMAGED HULL AND ASSOCIATED STRUCTURAL MEMBERS STARBOARD BOW.
Condition: Unknown
Due 23 July 1987
Resolved 23 July 1987
Unknown
Issued 16 April 1987 Resolved
INSTALL THRU HULL VALVES ON BOTH PORT & STBD BAIT TANK DRAINS (AFT COMPART-MENT)
Condition: Unknown
Due 16 April 1987
Resolved 16 April 1987
Construction/Loadline
Issued 12 June 1986 Resolved
RENEW BROKEN WINDOWS IN PILOT HOUSE
Condition: Unknown
Due 12 June 1986
Resolved 12 June 1986
Engineering
Issued 4 October 1985 Resolved
PROVIDE OR INSTALL A MEANS OF DETERMINING THE AMOUNT OR LEVEL OF FUEL IN THE FUEL TANKS ACCEPTABLE TO THE OFFICER IN CHARGE, MARINE INSPECTION, SAN DIEGO. IF A GAUGING DEVICE IS INSTALLED AT THE TANK CONNECTION,IT WILL HAVE A DEVICE WHICH WILL AUTOMATICALLY CLOSE IN THE EVENT OF RUPTURE.
Condition: Unknown
Due 4 October 1985
Resolved 4 October 1985

Casualty record · 1

28 July 2014Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4938036
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SEEKER (2014). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.