Records from 1983 to 1993. Most recent: inspection, 29 April 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 55
29 April 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1145807
9 March 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433987
27 August 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 956513
8 July 1992
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1270186
30 October 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 676522
30 April 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899884
29 April 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899729
29 April 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1307140
25 April 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 907167
19 April 1991
Deficiency Check · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1230240
18 April 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 905932
26 March 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922454
13 March 1991
COI Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1223732
18 February 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922302
8 January 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1243265
16 November 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1244786
26 October 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 931004
10 October 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 936303
24 September 1990
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1221904
16 May 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 928442
20 April 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1229920
12 April 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 919549
2 March 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 910837
12 December 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1233767
17 May 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1042759
10 April 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1197506
8 March 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 894889
21 September 1988
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1200147
17 June 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 894247
4 May 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1041067
28 March 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993960
4 March 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988826
11 May 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332236
10 March 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324236
5 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315555
5 November 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1329115
27 August 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320766
15 August 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012446
18 June 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293479
19 May 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296582
7 May 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992505
14 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987154
15 March 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999953
15 March 1986
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1001179
23 January 1986
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1001504
23 January 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306143
21 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290937
16 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 981869
12 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985861
12 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970799
18 January 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971084
16 November 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281710
2 June 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966043
28 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275971
23 February 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971190
Electrical
Issued 27 August 1992
Resolved
MAKE REPAIRS AND PROVE PROPER OPERATION OF THE #1 S/S GENERATOR REVERSE POWER RELAY PRIOR TO REACTIVATION OR ENGAGING IN DRILLING._x001C_
Condition: Unknown
Due 27 August 1992
Resolved 27 August 1992
Accommodation/Occupational Safety
Issued 27 August 1992
Resolved
INSTALL SMOKE OR HEAT DETECTORS IN ALL ACCOMODATION SPACES AS REQUIRED BY NVIC 4-78 PRIOR TO REACTIVATION OR ENGAGING IN DRILLING._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 August 1992
Resolved 27 August 1992
Fire Fighting
Issued 27 August 1992
Resolved
PROVIDE FACTORY INSTALLED COUPLINGS ON BOTH ENDS OF THE TEMPORARY HOSE USEDIN THE OUTBOARD FIRE PUMP DISCHARGE LINE OR HARD PIPE AND PROPERLY SUPPORT SAME PRIOR TO REACTIVATION OR ENGAGING IN DRILLING._x001C_ _x001C_
Condition: Unknown
Due 27 August 1992
Resolved 27 August 1992
Accommodation/Occupational Safety
Issued 8 July 1992
Resolved
INSTALL SMOKE OR HEAT DETECTORS IN ALL ACCOMODATION SPACES AS REQUIRED BY NVIC 4-78.
Condition: Unknown
Due 8 July 1992
Resolved 8 July 1992
Fire Fighting
Issued 8 July 1992
Resolved
PROVIDE FACTORY INSPTALLED COUPLINGS ON BOTH ENDS OF THE TEMPOARY HOSE USEDIN THE OUTBOARD FIRE PUMP DISCHARGE LINE OR HARD PIPE AND PROPERLY SUPPORT SAME.
Condition: Unknown
Due 8 July 1992
Resolved 8 July 1992
Electrical
Issued 8 July 1992
Resolved
MAKE REPAIRS AND PROVE PROPER OPERATION OF THE #1 S/S GENERATOR REVERSE POWER RELAY.
Condition: Unknown
Due 8 July 1992
Resolved 8 July 1992
Documentation
Issued 13 March 1991
Resolved
PROVIDE CERTIFICATE OF FINANCIAL RESPONSIBILITY PRIOR TO ABOVE NOTED DATE OR NEXT RIG MOVE WHICHEVER IS SOONER_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Fire Fighting
Issued 13 March 1991
Resolved
REPLACE RELIEF VALVE ON FIRE MAIN PUMPS NOT TO EXCEED 125 PSI.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Unknown
Issued 13 March 1991
Resolved
RENEW PERSONNEL GUARDS ON THREE OF THE FOUR MUD MIXER MOTORS AS INDICATED IN MUD PITS.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Unknown
Issued 13 March 1991
Resolved
RENEW DECK GRADING AFT OF BULK HOPPER IN MUD PIT AREA.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Electrical
Issued 13 March 1991
Resolved
CONDUCT SAFETY SYSTEM TESTS - OVERSPEED, LOW LUBE, HIGH TEMP - ON #1 AC GENERATOR, EMERGENCY GENERATOR, AND THREE EMD DC GENERATORS DURING NEXT RIGMOVE.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Lifesaving
Issued 13 March 1991
Resolved
RESERVICE #2 LIFE RAFT.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Engineering
Issued 13 March 1991
Resolved
REPAIR TACHOMETER ON #1 AC GENERATOR IN MACH SP.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Deck/Cargo
Issued 13 March 1991
Resolved
REPAIR OR REPLACE HATCH DOGS ON #4 AND #5 DRY BULK TANKS IN THE CEMENT ROOM.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Navigation
Issued 13 March 1991
Resolved
RENEW BROKEN GLOBE ON PORT STERN OBSTRUCTION LIGHT.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Navigation
Issued 13 March 1991
Resolved
PROVIDE APPROVED MARINE TYPE NAVIGATION LIGHTS FOR PORT, STBD, AND STERN RUNNING LIGHTS.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Electrical
Issued 13 March 1991
Resolved
RENEW WASTED CABLE RUN SUPPORTS ALONG AREA RUNNING FROM BELOW SHALE SHAKER AREA TO MUD PIT AREA.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Unknown
Issued 13 March 1991
Resolved
RENEW WASTED DECK GRADING UNDER MIXING HOPPER IN MUD PIT AREA.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Accommodation/Occupational Safety
Issued 13 March 1991
Resolved
RENEW PERSONNEL GUARD ON DEGASSER MOTOR IN SHALE SHAKER AREA.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Unknown
Issued 13 March 1991
Resolved
PROVIDE CONDUCTIVE MOTOR BELTS FOR DEGASSER MOTOR IN SHALE SHAKER AREA.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Electrical
Issued 13 March 1991
Resolved
RENEW EXPLOSION PROOF POWER CORD TO DESANDER MOTOR IN SHALE SHAKER AREA.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Electrical
Issued 13 March 1991
Resolved
RENEW WIRE RUNNING FROM SHAKER LIGHT ABOVE WORK AREA IN SHALE SHAKER AREA.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Accommodation/Occupational Safety
Issued 13 March 1991
Resolved
CONDUCT INTERNAL INSPECTION ON DRILL FLOOR AIR RECEIVER AND TEST RELIEF VALVE.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Lifesaving
Issued 13 March 1991
Resolved
REPLACE RESCUE BOAT MOTOR WITH PROPER 25 HP SIZE OUTBOARD.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Deck/Cargo
Issued 13 March 1991
Resolved
PROVIDE READABLE CRANE HAND SIGNAL PLACARDS ON PORT AND STBD CRANES.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Engineering
Issued 13 March 1991
Resolved
REPAIR BILGE PUMP IN AFT COLUMN PUMP ROOM.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Construction/Loadline
Issued 13 March 1991
Resolved
RENEW ALL WASTED BOLTS ON PIPING CONNECTIONS IN FWD AND AFT COLUMN PUMP ROOMS.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Construction/Loadline
Issued 13 March 1991
Resolved
REPLACE FRACTURED VALVE HOUSING ON #7 PORT CROSSOVER LINE IN AFT COLUMN PUMP ROOM.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Unknown
Issued 13 March 1991
Resolved
PROVIDE LOSS OF PURGE ALARM FOR MUD PUMP/DRAW WORKS CONTROL PANEL ON DRILLER'S CONSOLE DRILL FLOOR.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Unknown
Issued 13 March 1991
Resolved
PROVIDE LOSS OF PURGE ALARM FOR MUD FLOW MONITOR ON DRILLER'S CONSOLE DRILLFLOOR.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Unknown
Issued 13 March 1991
Resolved
PROVIDE LOSS OF PURGE ALARM FOR WMCO PUMP COUNTER UNIT ON DRILLER'S CONSOLEDRILL FLOOR.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Unknown
Issued 13 March 1991
Resolved
PROPERLY SEAL EYS FITTING ON WMCO INSTRUMENTS LOCATED ON STERN BULKHEAD OF DRILLER'S HOUSE ON DRILL FLOOR.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Unknown
Issued 13 March 1991
Resolved
PROVIDE AUDIO PURGE ALARM FOR SOUTHLAND RENTAL GAS DETECTION EQUIPMENT LOCATED ON PORT FWD BULKHEAD OF DRILL FLOOR.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Unknown
Issued 13 March 1991
Resolved
PROPERLY MOUNT LOUDSPEAKER ON PORT FWD BULKHEAD OF DRILL FLOOR.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Lifesaving
Issued 13 March 1991
Resolved
LABEL GENERAL ALARM ON DRILL FLOOR.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Unknown
Issued 13 March 1991
Resolved
RENEW GUARDS FOR FLOOR GLASS GLOBES ON WATER TRAPS FOR AIR SYSTEM LOCATED UNDER DRILL FLOOR.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Electrical
Issued 13 March 1991
Resolved
RENEW WASTED WIRE HANGS ALONG STERN HULL BELOW DRILL FLOOR IN AREA OF DRILLFLOOR AIR RECEIVER.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Lifesaving
Issued 13 March 1991
Resolved
LABEL GENERAL ALARM IN SHALE SHAKER.
Condition: Unknown
Due 13 March 1991
Resolved 13 March 1991
Construction/Loadline
Issued 16 November 1990
Resolved
PROVIDE FOR INSPECTION INTERNAL EXAM OF BALLAST TANKS AND COLUMNS, CONDUCT SWIM-BY EXAMINATION (VISUAL) TO UNDERSIDE OF ALL FOUR FOOTINGS.
Condition: Unknown
Due 16 November 1990
Resolved 16 November 1990
Construction/Loadline
Issued 24 September 1990
Resolved
REPLACE MOUNTING FOR AUTO BILGE PUMP IN FORWARD PUMP ROOM.
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Construction/Loadline
Issued 24 September 1990
Resolved
REPLACE ALL SHEAVES ON RIDING BELT SYSTEM, AFT PUMP ROOM. RE-ALIGN SHEAVE SUPPORTS FOR PROPER "FLEET ANGLE", FACE OF SHEAVES "SEVERLY" WORN DUE TO IMPROPER ANGLE.
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Construction/Loadline
Issued 24 September 1990
Resolved
CONDUCT GAUGINGS OF MAIN DECK AS DIRECTED BY AN ATTENDING COAST GUARD INSPECTOR, NUMEROUS HOLES ARE EXISTING.
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Construction/Loadline
Issued 24 September 1990
Resolved
MAKE AVAILABLE FOR CLOSER INSPECTION BY AN ATTENDING COAST GUARD INSPECTOR LARGE SET IN AREA ON STARBOARD BOW MOST FORWARD INTERMEDIATE VERTICAL TUBULAR.
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Construction/Loadline
Issued 24 September 1990
Resolved
REPLACE ALL WASTED GRATINGS, HAND RAILS, AND COLUMN SUPPORTS TO EMERGENCY ESCAPE LADDERS ON BOW AND STARBOARD SIDE.
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Construction/Loadline
Issued 24 September 1990
Resolved
CONDUCT GAUGINGS TO SALT WATER PIPING AS DIRECTED BY AN ATTENDING COAST GUARD INSPECTOR. (NOTE: INCLUDE SPOOL PIECES PARTICULARLY FORWARD PUMP ROOM LOW SUCTION), BOTH FORWARD AND AFT PUMP ROOMS.
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Construction/Loadline
Issued 24 September 1990
Resolved
REPACE ALL WASTED BOLTS ON VALVES AND FLANGE CONNECTIONS AND REPLACE PACK- IN ALL LEAKY PUMPS IN BOTH OF THE PUMP ROOMS.
Condition: Unknown
Due 24 September 1990
Resolved 24 September 1990
Lifesaving
Issued 2 March 1990
Resolved
RENEW THE PORT LIFEFLOAT.
Condition: Unknown
Due 2 March 1990
Resolved 2 March 1990
Electrical
Issued 2 March 1990
Resolved
RESUBMIT THE HAZARDOUS LOCATION PLAN SHOWING A CLASS I DIV. I AREA AROUND THE ROTARY TABLE. ]
Condition: Unknown
Due 2 March 1990
Resolved 2 March 1990
Fire Fighting
Issued 2 March 1990
Resolved
PERFORM ANNUAL SERVICING OF PORTABLE AND SEMIPORTABLE FIRE EXTINGUISHERS AS PER 46CFR 107.231 (J).
Condition: Unknown
Due 2 March 1990
Resolved 2 March 1990
Lifesaving
Issued 8 March 1989
Resolved
RENEW/REPLACE OUTDATED RING BUOY SMOKE FLARES. COMPLY BY: 08APR89
Condition: Unknown
Due 8 March 1989
Resolved 8 March 1989
Lifesaving
Issued 8 March 1989
Resolved
MOUNT MISSING RING BUOY. VESSEL HAD SEVEN (7) AND REQUIRES EIGHT (8). COMPLY BY: 08APR89
Condition: Unknown
Due 8 March 1989
Resolved 8 March 1989
Electrical
Issued 8 March 1989
Resolved
INSTALL CORRECT BATTERY TERMINAL FOR AUXILIARY/STANDBY GENERATORS. COMPLY BY: 08APR89
Condition: Unknown
Due 8 March 1989
Resolved 8 March 1989
Lifesaving
Issued 8 March 1989
Resolved
HAVE #1 LIFERAFT HYDROSTATIC RELEASE SERVICED. COMPLY BY: 08APR89
Condition: Unknown
Due 8 March 1989
Resolved 8 March 1989
Lifesaving
Issued 8 March 1989
Resolved
REPLACE LINE ON #2 LIFERAFT WITH PROPER METAL STRAP AND INSTALL HYDROSTATICRELEASE WITH REQUIRED TENSION. COMPLY BY: 08APR89
Condition: Unknown
Due 8 March 1989
Resolved 8 March 1989
Electrical
Issued 8 March 1989
Resolved
REPAIR EMERGENCY LIGHTS IN MUD PIT ROOM, PUMP ROOMS AND ON DRILL FLOOR. COMPLY BY: 08APR89
Condition: Unknown
Due 8 March 1989
Resolved 8 March 1989
Electrical
Issued 8 March 1989
Resolved
CHECK ALL EYS FITTINGS ON DRILL FLOOR, MUD PIT ROOM, SHALE SHAKER, ETC AND POUR ALL THOSE THAT ARE REQUIRED. COMPLY BY: 08APR898
Condition: Unknown
Due 8 March 1989
Resolved 8 March 1989
Construction/Loadline
Issued 8 March 1989
Resolved
ENSURE SUCTION SIDE OF DRAWWOORKS PURGE FAN DO NOT DRAW PURGING AIR FROM A CLASSED LOCATION. PRESENTLY GAP EXISTS AT CONNECTION IMMEDIATELY ABOVE FAN.
Condition: Unknown
Due 8 March 1989
Resolved 8 March 1989
Electrical
Issued 8 March 1989
Resolved
RENEW KICKPIPES IN SHALE SHAKER AREA. COMPLY BY: 08APR89
Condition: Unknown
Due 8 March 1989
Resolved 8 March 1989
Electrical
Issued 8 March 1989
Resolved
PROVE OPERATION OF HOTEL SERVICE GENERATORS AND ASSOCIATED SAFETY SYSTEMS. COMPY BY: 08APR89
Condition: Unknown
Due 8 March 1989
Resolved 8 March 1989
Construction/Loadline
Issued 8 March 1989
Resolved
MAKE BULK TANKS (5) AND DRILL FLOOR PRESSURE VESSEL AVAILABLE FOR INTERNAL EXAM BY U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 8 March 1989
Resolved 8 March 1989
Construction/Loadline
Issued 8 March 1989
Resolved
PROVE PROPER OPERATION OF DRILL FLOOR AIR RECEIVER RELIEF VALVE.
Condition: Unknown
Due 8 March 1989
Resolved 8 March 1989
Lifesaving
Issued 4 March 1988
Resolved
PROVIDE REQUIRED NUMBER OF TRIANGULAR BANDAGES FOR THE FIRST AID KIT. 46 CFR 108.707
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Electrical
Issued 4 March 1988
Resolved
SET OVERSPEED TRIPS ON #1 & 2 AC GENERATORS TO TRIP AT NOT MORE THAN 115% OF RATED RPM PER. (NVIC 4-78)
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Lifesaving
Issued 4 March 1988
Resolved
PROVIDE BOATHOOK FOR EACH LIFEFLOAT. 33 CFR 144.
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Navigation
Issued 4 March 1988
Resolved
PROVIDE RELIEF VALVE WITH HAND RELIEVING GEAR FOR NO. 3 WEIGHT TANK. NAME PLATE DATA MISSING RELIEF VALVE SHALL BE SET AT NOT MORE THAN 40 PSIG. (46 CFR 54)
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Navigation
Issued 4 March 1988
Resolved
PROVIDE RELIEF VALVE WITH HAND RECIEVING GEAR FOR THE BULK AIR STORAGE TANKNAME PLATE DATA MISSING. RELIEF VALVE SHALL BE SET AT NOT MORE THAN THE MAWP OF THE AIR RECEIVER. (46 CFR 54)
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Electrical
Issued 4 March 1988
Resolved
PROPERLY SUPPORT ALL ELECTRICAL CABLE FROM RIG TO DRILL FLOOR. CABLES ARE FRAYED, INSTALLATION MISSING, CHAFFED AND UNDER A STRAIN BY NOT BEING PROPERLY SUPPORTED. (NVC 4-78, IEEE)
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Accommodation/Occupational Safety
Issued 4 March 1988
Resolved
PROVE PROPER OPERATION OF THE MARINE SANITATION DEVICE. CURRENTLY EMTYME GRINDER NOT OPERTING PROPERLY, CLORINE UNIT MISSING, AIR PRESSURE GAUGE INOPERATIVE AND EFFLUENT SEPTIC IN UNIT. (PER NPDES REQ.)
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Electrical
Issued 4 March 1988
Resolved
PROVE EXPLOSION PROOF ELECTRICAL EQUIPMENT IN THE MUD LAB OR PROVIDE THE SPACE WITH A POSITIVE AIR PRESSURE WITH LOSS OF VENTILATION ALARM. (SUBMIT PLAN TO MSO NOLA) (PER 46 CFR OLD "J", NVC 4-78)
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Navigation
Issued 4 March 1988
Resolved
PROVIDE RELIEF VALVE SET AT NOT MORE THAN THE MAWP OF THE MAIN POTABLE WATER PRESSURE TANK AND OPEN FOR INTERNAL INSPECTION IF RELIEF VALVE SET AT MORE THAN 100 PSI. THIS SHALL ENCLUDE CALCULATION FOR HEAD PRESSURE ON THE TANK DUE TO THE ELEVATED LOCATION OF THE RELIEF VALVE.
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Fire Fighting
Issued 4 March 1988
Resolved
PROVIDE RELIEF VALVE FOR THE FIRE PUMP SET AT NOT MORE THAN 125 PSI. (NVC 4-78)
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Electrical
Issued 4 March 1988
Resolved
PROVE SATISFACTORY OPERATION OF ALL THE AIR PURGE EQUIPMENT ON THE DRILL FLOOR. REMOVE ALL LOOSE & DEAD END WIRES. PROPERLY SUPPORT ALL ELECTRICALCABLE RUNS ON THE DRILL FLOOR. (NVC 4-78 & IEEE)
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Navigation
Issued 4 March 1988
Resolved
PROVIDE MAXIMUM ALLOWABLE WORKING PRESSURE FOR THE POTABLE WATER RESERVE TANK. PROVIDE RELIEF VALVE FOR SAME SET AT NOT MORE THAN THE MAWP OF THE TANK. (PER 46 CFR 56)
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Electrical
Issued 4 March 1988
Resolved
TIGHTEN ALL EXPLOSION PROOF LIGHTING FIXTURE END CAPS LOCATED IN THE SHAKERAREA. PROVIDE EVIDENCE THAT THE MUD MONITOR (ANADRILL) IS EXPLOSION PROOF.UNIT HAS GASKET CAP AND NO VISIBLE NAME PLATE DATA. (PER 46 CFR OLD "J" NVC 4-78)
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Electrical
Issued 4 March 1988
Resolved
PROVIDE "EYS" FITTINGS ON ALL NEW ELECTRICAL INSTALLATIONS ON THE DRILL FLOOR. PROPERLY SEAL ALL "EYS" (NEW) FITTINGS ON THE DRILL FLOOR. (PER 46 CFR OLD "J" NVC 4-78)
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Electrical
Issued 4 March 1988
Resolved
MUD PITS; REMOVE ALL SPICES IN THE ELECTRICAL POWER CABLES, PROVIDE EYS FITTING AND AIR PURGE WHERE REQUIRED ON THE CENTERFUGE AND MUD CLEANER. PROPERLY SUPPORT CABLE RUN TO LOGGING POWER SHACK LOCATED MAINDECK, STBD AFT.
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Construction/Loadline
Issued 4 March 1988
Resolved
REPPAIR CRACK/WASTAGE IN WAY OF CONNECTION BETWEEN #10 STBD TANK AND HORIZONTAL SUPPORT MEMBER AS ORIGINAL. NVIC 3-78 3(D).1
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Accommodation/Occupational Safety
Issued 4 March 1988
Resolved
PROVIDE RELIEF VALVE FOR THE POTABLE H2O TANK THAT DOES NOT EXCEED THE MAWP OF THE TANK, I.E. 150 PSI. NVIC 3-78(H)
Condition: Unknown
Due 4 March 1988
Resolved 4 March 1988
Unknown
Issued 10 March 1987
Resolved
DEMONSTRATE SATISFACTORY OPERATION OF OVERSPEEP TRIP ON EMERGENCY GENERATOR DIESEL.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Unknown
Issued 10 March 1987
Resolved
PROVIDE FLAME SCREENS FOR BULK LUBE OIL STORAGE TANKS 46 CFR 60 NVCL 4.78.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Unknown
Issued 10 March 1987
Resolved
MAKE AVAILABLE FOR TESTING THE FOLLOWING, RELIEF VALVES: BOTH SHIPS SERVICEAIR RECEIVER RELIEF VALVES AND RIG FLOOR AIR RECEIVER RELIEF VALVE. 46 CFR54 AND C1.10.5
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Unknown
Issued 10 March 1987
Resolved
MAKE AVAIALBE FOR INTERNAL EXAMINATION THE FOLLOWING PRESSURE VESSELS: BOTH SHIP SERVICE AIR RECEIVERS, RIG FLOOR AIR RECEIVER, BULK TANK NO.1 ANDBULK TANK NO.2. 46 CFR 54 AND CFR 62.10.5.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Unknown
Issued 10 March 1987
Resolved
REPLACE MISSING LOWER RAILING RUNGS ON CRANE AREA RAILIGS 46 CFT 108.705
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Unknown
Issued 10 March 1987
Resolved
REPAIR WASTED CABLE TRAYS LOCATED IN WAY OF AFT REILING, PORT SIDE VICINITYOF DRILL FLOOR 46 CFR 111.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Unknown
Issued 10 March 1987
Resolved
REPAIR FUEL OIL LEAK ON DIESEL EVER FEED LINE TO NO.3 EMD 46 CFR 58.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Unknown
Issued 10 March 1987
Resolved
PROVIDE EVIDENCE THAT THE THREE (3) PRESSURE VESSEL INSTALLING IN EACH WATER SYSTEM HAVE UNDERGONE THE HYDROSATIC TEST REQUIRING BY NVC 4-78 PARA3(D)(11) OR CONDUCT SAME IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Unknown
Issued 10 March 1987
Resolved
MAKE DRAFT MARKS LEGIBLE IN CONTRASTING COLOR TO HULL 46 CFR 108.661 NVIC 4-78
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Unknown
Issued 10 March 1987
Resolved
PROVIDE SHOULDER GUN LINE THROWING APPARATUS WITH 500 FOOT AUXILARY LINE 46 CFR 160 NUIC 4-78.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Unknown
Issued 10 March 1987
Resolved
PROVIDE TWO PADDLES FOR RESCUE BOAT NUIC 4-78 PARA 3(D)(E).
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Unknown
Issued 10 March 1987
Resolved
CONDUCT GENERAL CLEAN UP OF LILY RESIDUE UNDERNEATH ALL GENERAL DIESEL ENGINES.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Unknown
Issued 10 March 1987
Resolved
PROVIDE EVIDENCE THAT OIL TRANSFER HOSE IS APPROVED FOR OIL SERVICE AND THAT IT HAS UNDERGONE 1.5X MAWP HYDRO TEST WITHIN PAST 12 MONTHS 33 CFR 155.800.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Unknown
Issued 10 March 1987
Resolved
MAKE OPERABLE EMERGENCY LIGHT IN AFT PUMPROOM 46 CFR 111.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Unknown
Issued 10 March 1987
Resolved
REPAIR LEAKING PACKING GLAND ON NO.1 BALLAST PUMP, FORWARD PUMPROOM 46 CFR 56.50.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Unknown
Issued 10 March 1987
Resolved
REMOVE DEAD END CABLE LOCATED AS WALKWAY OUTSIDE OF MUD PIT ROOM STRD SIDE OF RIG 46 CFR 111.
Condition: Unknown
Due 10 March 1987
Resolved 10 March 1987
Unknown
Issued 7 May 1986
Resolved
MAKE EFFECTIVE REPAIRS TO THE STARBOARD TEN FOOT COLUMN AT THE WATERLINE WITH A 6 FOOT BY 8 FOOT SECTION OF PLATE AND WHERE THE COLUMN MEETS THE UPPER DECK, PRIOR TO THE RIG BEING PLACED BACK IN SERVICE.
Condition: Unknown
Due 7 May 1986
Resolved 7 May 1986
Unknown
Issued 7 May 1986
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 7 May 1986
Resolved 7 May 1986
Unknown
Issued 7 May 1986
Resolved
READJUST OVERSPEED ON STANDBY GENERATOR TO OPERATE LESS THAN 2070 RPM.
Condition: Unknown
Due 7 May 1986
Resolved 7 May 1986
Unknown
Issued 7 May 1986
Resolved
REMOVE HARD PIPING OF PORTABLE WATER TO ENGINE RADIATORS.
Condition: Unknown
Due 7 May 1986
Resolved 7 May 1986
Unknown
Issued 7 May 1986
Resolved
REPAIR LOW LUBE OIL PRESSURE ALARM TO #2 EMD.
Condition: Unknown
Due 7 May 1986
Resolved 7 May 1986
Unknown
Issued 7 May 1986
Resolved
PROVIDE PROTECTIVE GUARDS FOR EXPOSED SHAFTS ON DIESEL POWERED AIR COMPRESSER UNITS.
Condition: Unknown
Due 7 May 1986
Resolved 7 May 1986
Unknown
Issued 7 May 1986
Resolved
PROVIDE RELIEF VALVES ON HOT WATER HEATERS TO RELIEVE LESS THAN 100 PSIG ORMAKE AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 7 May 1986
Resolved 7 May 1986
Unknown
Issued 7 May 1986
Resolved
REMOVE ELECTRICAL WIRING NOT PERMANENTLY SUPPORTED, LOCATED NEAR DRILLER'S CONSOLE, AND REPAIR PORTABLE CABLE AT JUNCTION BOX.
Condition: Unknown
Due 7 May 1986
Resolved 7 May 1986
Unknown
Issued 7 May 1986
Resolved
REMOVE SPLICE AT EYS FITTING AT DRILLER'S CONSOLE AND PROVIDE INTRINSICALLYSFE DRILLER'S PEDAL OR PURGING OF PEDAL UNIT.
Condition: Unknown
Due 7 May 1986
Resolved 7 May 1986
Unknown
Issued 7 May 1986
Resolved
PROVIDE ON BOARD AN APPROVED COPY OF THE CLASSIFIED LOCATION PLAN WITH APPROVAL LETTER.
Condition: Unknown
Due 7 May 1986
Resolved 7 May 1986
Unknown
Issued 7 May 1986
Resolved
SUBMIT FOR APPROVAL TO THE [name withheld] OF A CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 7 May 1986
Resolved 7 May 1986
Unknown
Issued 7 May 1986
Resolved
REPAIR LIGHTING AT LIFERAFT STATION NO. 2
Condition: Unknown
Due 7 May 1986
Resolved 7 May 1986
Unknown
Issued 7 May 1986
Resolved
MAKE APPROPRIATE REPAIRS TO THE LIFEFLOAT AT STATION NO. 4, AND PROVIDE NAMEPLATE APPROVAL DATA FOR BOTH LIFEFLOATS. MANNING IS REDUCED TO 37 PERSONS TOTAL UNTIL THE LIFEFLOAT IS REPAIRED.
Condition: Unknown
Due 7 May 1986
Resolved 7 May 1986
Construction/Loadline
Issued 15 March 1986
Resolved
REPLACE WASTED NUTS (3) ON THE LOWER FLANGE NEAR THE BALLAST PUMP NO.4 LOCATED IN THE AFT PUMP ROOM. (IE LST FLANGE OFF THE DISCHARGE SIDE OF PUMPROOM).
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986
Resolved
CROP/RENEW OR REMOVE THE THROUGHLY WASTED 4" SEA WATER PIPE FUNNING THE LENGTH OF THE AFT PUMP ROOM BENEATH THE DECK GRATING.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986
Resolved
REPLACE BOLTS TO MAN HOLE COVER ON TOP OF 10' DIA. PORT COLUMN.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Electrical
Issued 15 March 1986
Resolved
MAKE OPERABLE THE EXTINGUISHED LIGHTS IN THE FORWARD PUMP RM ESCAPE ROUTE COLUMN.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986
Resolved
PROVIDE ULTRASONIC GAUGINGS OF THE FOUR 22' DIA. CORNER COLUMNS. GAUGING TO BE TAKEN AT THE WIND&WATER LINES OF THE DIFFRENT DRAFTS THE RIG HAS OPERATED AT SINCE 1980 (IE. LAST OUT OF WATER D/D & LAST GUAGINE REPORT). PLANS FOR THE GUAGE TESTING SHOULD BE SUBMITTED TO OUR OFFICE.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986
Resolved
REPAIR HAIRLINE CRACKS IN THE WELDMENT ON THE LOW SUCTION SEA VALVE BODY INTHE FORWARD PUMP ROOM.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986
Resolved
REPAIR WELD CRACKS FOUND IN MULTIPLE AREAS ON THE OVERBOARD DISCHARGE SEA VALVE BODY IN THE FORWARD PUMP ROOM.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986
Resolved
REPAIR WASTED "ENTRANCE VENTILLATION BOX" ON TOP OF THE AFT PUMP ROOMS ESCAPE ROUTE COLUMN.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Electrical
Issued 15 March 1986
Resolved
RE-ATTACH JUNCTION BOX LIGHT TO SIDE PLATE IN THE COLUMN LEADING DOWN TO THE AFT PUMP ROOM.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986
Resolved
REPLACE WASTED NUTS AND BOLTS BODYS CONNECTION ON THE FOLLOWING BALLAST CONTROL VALVES IN THE AFT PUMP ROOM. 55,65,50,XO.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Unknown
Issued 15 March 1986
Resolved
CONDUCT UNDERWATER EXAMINATION W/VIDEO OF MAT TOP&BOTTOM.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986
Resolved
INTERNAL INSPECTION OF THE FOUR 22' DIA. CORNER COLUMNS IS TO BE COMPLETED.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986
Resolved
CROP AND RENEW WASTED SUPPORT MEMBER PIPE (APPROX 6"IN DIA.) THAT TIES TOGETHER DIAGONALLY THE 22'DIA. PORT BOW COLUMN TO MAIN DECK SUPPORT TRANSVERSE I-BEAM.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Deck/Cargo
Issued 15 March 1986
Resolved
REPAIR/REPLACE THE TWO WASTED TRAVELING BLOCKS LOCATED ON THE OUTBOARD SIDEOF THE MOON POOL. THESE ARE USED FOR THE SUSPERSION GRATING. ALSO CROP AND RENEW THE WASTED 8" I-BEAM WHICH THESE BLOCKS TRAVEL ON.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986
Resolved
PROVIDE WRITTEN REPORT OF THE EDDY CURRENT (NOT) EXAMINATION TO MIO NEW ORLEANS, OCS SECTION OFFICE.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986
Resolved
BUILD UP, SEVERLY UNDERCUT WELDMENT ON THE CONNECTION LINE RUNNING FROM THEHIGH NAMIFOLD TO THE TANK MANIFOLD IN THE AFT PUMP ROOM.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986
Resolved
CROP AND RENEW THE SQUARE CONFIGURED 8"I-BEAMS LOCATED FROM THE OVERHEAD OFTHE MOON POOL AREA, PORT SIDE. THE BOTTOM(HORIZONTAL) I-BEAM IS WASTER, AND THE VERTICAL I-BEAM IS FRACTURED WHERE IT IS WELDED TO OVERHEAD DRILL FLOOR SUPPORT BEAM. SEE SPEC INST. BELOW.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Construction/Loadline
Issued 15 March 1986
Resolved
CROP & RENEW ALL WASTED SUPPORT PIPES (APPROX 3"DIA.) ON THE FORWARD EMBARKATION STAIRWAY (IE STARWAY UNDER DRILL FLOOR). THESE PIPES RUN DIAGONALLY FROM UNDER THE STAIRWAY LANDINGS TO THE 4' DIA. COLUMN.
Condition: Unknown
Due 15 March 1986
Resolved 15 March 1986
Unknown
Issued 16 April 1985
Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL TRANSWORLD 47 CG000132
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Construction/Loadline
Issued 16 April 1985
Resolved
MAKE PERMANENT REPAIRS TO DAMAGED AREA ON #10 PORT COLUMN CROP AND RENEW APPROXIMATELY 8'X8'X 3/8 ROLLED PLATE TWO RING STIFFENERS AND ONE VERTICAL ANGLE IN WAY OF THE DAMAGED AREA SEAM WELDS TO BE HOSE TESTED AND WITNESSEDBY COAST GUARD.
Condition: Unknown
Due 16 April 1985
Resolved 16 April 1985
Unknown
Issued 16 November 1983
Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL TRANSWORLD RIG 47 CG000132.
Condition: Unknown
Due 16 November 1983
Resolved 16 November 1983
Construction/Loadline
Issued 16 November 1983
Resolved
MAKE VESSEL AVAILABLE FOR VIDEO EXAMINATION OF THE UNDERWATER PORTION OF OF THE MAT AT THE NEXT RIG MOVE.
Condition: Unknown
Due 16 November 1983
Resolved 16 November 1983
Unknown
Issued 23 February 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL TRANSWORLD RIG 47, CG000132
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Documentation
Issued 23 February 1983
Resolved
PROVIDE APPROVED OPERATING MANUAL ABOARD THE RIG.
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Documentation
Issued 23 February 1983
Resolved
PROVIDE STABILITY LETTER ABOARD THE RIG.
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Documentation
Issued 23 February 1983
Resolved
PROVIDE FREEBOARD ASSIGNMENT ABOARD THE RIG.
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Construction/Loadline
Issued 23 February 1983
Resolved
HAVE VESSEL DRYDOCKED OR CONDUCT SPECIAL EXAM IN LIEU OF DRYDOCKING.
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Electrical
Issued 23 February 1983
Resolved
MAKE GENERAL ALARM ON DRILL FLOOR OPERATIONAL.
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Navigation
Issued 23 February 1983
Resolved
PROVIDE VESSEL AGROUND LIGHTS (RED OVER RED) AND DAY SHAPES (THREE BLACK BALS) ABOARD VESSEL.
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Electrical
Issued 23 February 1983
Resolved
(REQUIREMENT E11 CONTINUED) MOTORS AND ASSOCIATED WIRING.
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Electrical
Issued 23 February 1983
Resolved
IN THE MUD PIT AREA: (A) MAKE CONECTION TO MUD PUMP MOTORS EXPLOSION PROOF OR AIR PURGED, (B) REPAIR AIR PURGE ALARM TO PIT LEVEL INDICATOR.
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Electrical
Issued 23 February 1983
Resolved
IN THE SHAKER AREA: (A) TERMINATE DEAD END WIRES NEAR PHONE AND ABOVE SHAKER UNITS, (B) REMOVE OR MAKE EXPLOSION PROOF BOTH AGITATOR EXPLOSION
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Construction/Loadline
Issued 23 February 1983
Resolved
REPAIR UPSET DECK LEADING TO STARBOARD CRANE.
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Accommodation/Occupational Safety
Issued 23 February 1983
Resolved
PROVIDE DOCUMENTATION FROM BEMCO INC. THAT INSTALLED MSD IS ACCEPTABLE FOR INSPECTED VESSEL.
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Fire Fighting
Issued 23 February 1983
Resolved
PROVIDE A SECONDARY FIRE PUMP CAPABLE OF MEETING 46 CFR 108.415.
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Construction/Loadline
Issued 23 February 1983
Resolved
REPAIR RAILING ON CATWALK FORWARD ON STARBAORD (GREEN) RUNNING LIGHT.
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Electrical
Issued 23 February 1983
Resolved
PROVIDE COAST GUARD APPROVED HAZARDOUS LOCATIONS PLAN ABOARD THE RIG.
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Electrical
Issued 23 February 1983
Resolved
PROVIDE EMERGENCY LIGHTS IN HALIBURTON ROOM.
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Construction/Loadline
Issued 23 February 1983
Resolved
REPAIR/PROVIDE FOLLOWING HAND RAILS (A) CRACKED WELD AT BASE OF HANDRAIL STARBOARD SIDE FORWARD NEAR DRILL FLOOR AIR RECEIVER, (B) MISSING HAND RAIL
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Construction/Loadline
Issued 23 February 1983
Resolved
(REQUIREMENT E3 CONTINUED) WHERE SHALEY WASHER UNIT USED TO BE, (C) BENT AND BROKEN RAIL ON TOP OF SHAKER ROOF.
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Engineering
Issued 23 February 1983
Resolved
REPAIR OVERSPEED TRIP ON #2 DC EMD GENERATOR.
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Electrical
Issued 23 February 1983
Resolved
REPAIR LOW L/O PRESSURE ALARM AND HIGH JW TEMP ALARM ON EMERGENCY GENERATOR.
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983
Engineering
Issued 23 February 1983
Resolved
PROVIDE OPERABLE PRESSURE GUAGES AND ASME RELIEFS SET AT OR BELOW 170 PSIG FOR THE TWO SHIP SERVICE/STARTING AIR RECIEVERS IN ENGINE ROOM.
Condition: Unknown
Due 23 February 1983
Resolved 23 February 1983