MAURY USCG vessel records Sign in
← All vessels

GOLDEN ANCHOR II

GOLDEN ANCHOR II is a 1953 unclassified. The Coast Guard has recorded 25 inspections since 1985, most recently in November 1999, along with 30 deficiencies.

Records from 1985 to 1999. Most recent: inspection, 8 November 1999.

Built
1953
Last inspected
8 November 1999
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-53250

Inspections, by type

…with no type recorded4
Years with a record 12 calendar years (1985–1999)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Net Ton
95 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 25

8 November 1999 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 806813
26 March 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1078751
11 December 1995 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1188424
17 March 1995 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1136901
22 February 1995 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 850846
3 February 1994 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1162552
12 January 1994 Hull Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 851548
17 November 1993 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1145300
8 November 1993 Drydock Extension
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1403699
23 March 1993 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1146200
4 January 1993 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1141640
2 December 1992 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 829865
17 October 1991 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 939329
9 August 1990 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1210291
8 June 1990 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1217028
11 April 1990 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1227622
19 July 1989 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1348097
12 April 1989 Hull Examination · Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 895831
4 September 1987 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1000225
4 June 1987 COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1335808
28 May 1986 Re-Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1297255
22 October 1985 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1305709
10 August 1985 Credit Drydock
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1289191
9 July 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1291344
24 June 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1290397

Deficiency record · 30

Lifesaving
Issued 22 February 1995 Resolved
PROVIDE TWO REPLACEMENT USCG APPROVED TYPE 1 ADULT LIFE PRESERVERS. VESSEL RESTRICTED TO 43 PASSENGERS UNTIL ABOVE REQUIREMENT IS MET.
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995
Engineering
Issued 22 February 1995 Resolved
PROPERLY MARK THE REMOTE EMERGENCY FUEL SHUT-OFF VALVE FOR THE MAIN PROPULSION ENGINE.
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995
Electrical
Issued 22 February 1995 Resolved
REMOVE EXTRA BATTRIES FROM MACHINERY SPACE.
Condition: Unknown
Due 22 February 1995
Resolved 22 February 1995
Lifesaving
Issued 12 January 1994 Resolved
PROVIDE ON BOARD A NEW EPIRB BATTERY.
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Lifesaving
Issued 12 January 1994 Resolved
INSTALL PROPER FOAM BALLAST IN EIGHT (8) AUTOMATIC ELECTRIC FLOAT LIGHTS._x001C_
Condition: Unknown
Due 12 January 1994
Resolved 12 January 1994
Accommodation/Occupational Safety
Issued 8 November 1993 Resolved
PROVE PROPER OPERATION OF MSD MACERATOR PUMP.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Documentation
Issued 8 November 1993 Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH RANDOM DRUG TEST PROCEDURES.
Condition: Unknown
Due 20 November 1993
Resolved 18 November 1993
Construction/Loadline
Issued 8 November 1993 Resolved
RENEW AS ORIGINAL FOREPEAK HATCH COVER AND SEAL PRIOR TO GETTING UNDERWAY BUT IN NO CASE LATER THAN 20 NOV 93.
Condition: Unknown
Due 20 November 1993
Resolved 18 November 1993
Electrical
Issued 2 December 1992 Resolved
REPAIR AND PROVE PROPER OPERATION OF SWITCHBOARD GROUND FAULT INDICATOR.
Condition: Unknown
Due 4 January 1993
Resolved 4 January 1993
Documentation
Issued 2 December 1992 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 4 January 1993
Resolved 4 January 1993
Navigation
Issued 2 December 1992 Resolved
INSTALL AND PROVE PROPER OPERATION OF 135 DEGREE STERN LIGHT.
Condition: Unknown
Due 4 January 1993
Resolved 4 January 1993
Accommodation/Occupational Safety
Issued 2 December 1992 Resolved
PROVIDE BUNKS IN AFT PILOTHOUSE AREA FOR TWO CREWMEMBERS FOR TWENTY-FOUR HOUR OPERATION.
Condition: Unknown
Due 4 January 1993
Resolved 4 January 1993
Navigation
Issued 2 December 1992 Resolved
COMPLETE REPAIRS AND PROVE PROPER OPERATION OF AUTO PILOT OR REMOVE FROM VESSEL. (OPTIONAL EQUIPMENT)
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Accommodation/Occupational Safety
Issued 2 December 1992 Resolved
INSTALL AND PROVE PROPER OPERATION OF 3/4 LEVEL INDICATOR ON SEWAGE HOLDINGTANK AND TERMINATE WIRE SPLICE FOR SENSOR IN JUNCTION BOX IN WAY OF HOLDINGTANK OVERHEAD.
Condition: Unknown
Due 2 December 1992
Resolved 2 December 1992
Navigation
Issued 2 December 1992 Resolved
CONVERT STEERING PUMP ELECTRIC MOTOR TO SINGLE PHASE FOR PROPER OPERATION ON BOTH PORT AND STARBOARD GENERATORS.
Condition: Unknown
Due 4 January 1993
Resolved 4 January 1993
Electrical
Issued 8 June 1990 Resolved
INSTALL COVERS OVER ALL OF THE OPEN SWITCH POSITIONS IN ALL POWER PANELS THROUGHOUT THE VESSEL.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Engineering
Issued 8 June 1990 Resolved
RESECURE THE LOOSE FLAME SCREEN IN THE PORT FUEL TANK GOOSENECK VENT.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Electrical
Issued 8 June 1990 Resolved
STARBOARD GENERATOR IS NOT TO BE UTILIZED UNTIL ALL GUARDS AND COVERS ARE IN PLACE AND ITS OPERATION PROVEN TO A MARINE INSPECTOR. IN LIEU THEREOF, THE UNIT MAY BE TOTALLY DISABLED BY REMOVAL OF FUEL SUPPLY, AND REMOVAL OF CABLE AND RELAYS AT/TO THE MAIN POWER PANEL.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Electrical
Issued 8 June 1990 Resolved
RENEW CABIN-TOP STUFFING TUBES FOR ELECTRICAL CABLES AND REMOVE ALL UNUSED CABLE THEIR ENTIRE LENGTH FROM SOURCE TO LOAD.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Construction/Loadline
Issued 8 June 1990 Resolved
MARK THE FORWARD HATCH "EMERGENCY ESCAPE KEEP CLEAR".
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Construction/Loadline
Issued 8 June 1990 Resolved
THE FORWARD AND AFT HATCHES ARE TO BE MADE OPERABLE FROM THE MAIN DECK, FABRICATING T-HANDLE WRENCHES AS NECESSARY. THE ASSOCIATED SPACES ARE NOT TO BE ENTERED UNLESS IN EMERGENCY OR THE VESSEL IS AT A SHORESIDE DOCK.
Condition: Unknown
Due 8 June 1990
Resolved 8 June 1990
Documentation
Issued 12 April 1989 Resolved
OBTAIN AND POST, THE VESSEL'S STABILITY LETTER.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Electrical
Issued 12 April 1989 Resolved
REPAIR AND PROVE PROPER OPERATION OF THE PORT S/S DIESEL GENERATOR.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Accommodation/Occupational Safety
Issued 12 April 1989 Resolved
REPAIR/RENEW THE AUTOMATIC CLOSING LOUVERS FOR THE ENGINEROOM INTAKE VENTS.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Engineering
Issued 12 April 1989 Resolved
INSTALL MARINE APPROVED FUEL OIL FILTERS FOR ALL PRIME MOVER'S. (SSDG/MDE)
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Documentation
Issued 4 June 1987 Resolved
PROVIDE A FCC SHIP STATION LICENSE AND TEST CERT OR EQUIVLENT IN COMPLIANCEWITH FCC REGULATIONS. BOTH FOR THE SSB AND VHF-FM RADIO.
Condition: Unknown
Due 4 June 1987
Resolved 4 June 1987
Navigation
Issued 28 May 1986 Resolved
PROVIDE A VALID FCC LICENSE OR EQUIVALENT TO FCC REGULATION PRIOR TO SAILING MORE THAN 20 MILES FROM THE NEAREST LAND. IN ADDITION, VESSEL MUST BE EQUIPPED WITH SINGLE SIDE BAND RADIO PRIOR TO SAILING MORE THAN 20 MILESFROM THE NEAREST LAND.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Lifesaving
Issued 28 May 1986 Resolved
PROVIDE AN APPROVED TYPE WATERLIGHT FOR ONE OF THE LIFEFLOAT ON BOARD PRIORTO ANY NIGHT TIME OPERATION.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Construction/Loadline
Issued 10 August 1985 Resolved
PROVIDE ACCESS TO BILGES BELOW BERTHING AREAS FOR INSPECTION
Condition: Unknown
Due 10 August 1985
Resolved 10 August 1985
Unknown
Issued 9 July 1985 Resolved
CONDUCT FIRST REINSPECTION PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE
Condition: Unknown
Due 9 July 1985
Resolved 9 July 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.