Records from 1981 to 1999. Most recent: inspection, 27 April 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
27 April 1999
Administrative
Administrative · Activities Europe · Activity 790551
29 June 1998
Deficiency Check
Physical examination · Activities Europe · Activity 1128028
21 May 1998
Administrative
Administrative · Activities Europe · Activity 792329
9 April 1998
Type not recorded
No type recorded · Activities Europe · Activity 669665
10 March 1998
Hull Examination · COI Inspection
Physical examination · Activities Europe · Activity 1424554
13 January 1998
Administrative
Administrative · Activities Europe · Activity 785569
25 September 1997
Administrative
Administrative · Activities Europe · Activity 1114196
11 February 1997
Type not recorded
No type recorded · Activities Europe · Activity 214483
22 August 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1085708
25 October 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 867742
23 June 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387257
30 July 1991
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 938668
31 December 1990
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1243055
13 July 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1223344
13 July 1989
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 971081
16 February 1989
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1350098
7 July 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1207702
27 August 1987
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1308055
29 July 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1029260
7 August 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322247
6 August 1985
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987492
1 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283229
6 September 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280517
1 September 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969565
Navigation
Issued 10 March 1998
Resolved
Prove proper operation of the pilot house rudder angle indicator.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Electrical
Issued 10 March 1998
Resolved
Prove proper operation of stbd generator oil and tempurature gauges.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Electrical
Issued 10 March 1998
Resolved
Replace broken generator bearing oil sight glass for the stbd ship service generator.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Accommodation/Occupational Safety
Issued 10 March 1998
Resolved
Repair galley range hood fan.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Electrical
Issued 10 March 1998
Resolved
Prove proper operation of lower berthing emergency light in way of ladder.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Accommodation/Occupational Safety
Issued 10 March 1998
Resolved
Permanently secure all engineroom deck plates.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Electrical
Issued 10 March 1998
Resolved
Replace broken meter to the engineroom battery charger.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Lifesaving
Issued 10 March 1998
Resolved
Provide CG approved liferafts for all POB as indicated on COI. Vsl limited to 16 total persons on board until appropriate number of liferafts provided.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Electrical
Issued 10 March 1998
Resolved
Properly support electrical wiring runs throughout vessel with metal bands not plastic.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Lifesaving
Issued 10 March 1998
Resolved
Provide additional life jacket donning instructions for the horse collar style.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Lifesaving
Issued 10 March 1998
Resolved
Provide lifesaving signals placard and post on vessel.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Electrical
Issued 10 March 1998
Resolved
Prove proper operation of both ship service generator tachometers.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998
Documentation
Issued 10 March 1998
Resolved
Provide all applicable 33 & 46 CFR publications for vessel.
Condition: Unknown
Due 10 March 1998
Resolved 10 March 1998