Records from 1981 to 2002. Most recent: inspection, 16 July 2002.
Inspection history · 31
16 July 2002
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1646876
3 June 2002
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1646652
22 February 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1488398
23 October 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 769197
25 September 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 196934
23 February 2001
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1376505
19 January 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 77964
11 February 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391228
21 December 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 29005
20 April 1999
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433453
3 March 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386211
10 April 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418134
28 February 1996
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357546
8 March 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448642
22 February 1994
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1428320
8 June 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407165
10 July 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 946424
23 June 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449551
26 June 1991
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1229079
28 May 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1331333
18 September 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1003956
26 July 1989
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 888049
17 February 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1014841
16 August 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298803
17 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1288169
6 September 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282799
21 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974152
19 August 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972164
20 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964615
1 July 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273543
27 August 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965972
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 February 2002
Resolved
REMOVE EXTENSION CORD SERVING AS PERMANENT WIRING FOR FREEZER.
Condition: Improper Installation
Due 22 February 2002
Resolved 22 February 2002
Navigation › Piloting/Steering › Coast Guard Light List
Issued 22 February 2002
Resolved
PROVIDE UPDATED LIGHT LIST
Condition: Unknown
Due 22 February 2002
Resolved 22 February 2002
Engineering › Fuel Oil Service System › Gauge
Issued 22 February 2002
Resolved
INSTALL FLAME RESISTANT SIGHT GLASSES ON ALL F/O DAY TANKS.
Condition: Improper/Lack of Maintenance
Due 22 February 2002
Resolved 22 February 2002
Accommodation/Occupational Safety › Potable Water System
Issued 22 February 2002
Resolved
PROPERLY SECURE WATER HEATER LEGACY COMPONENT DESC: HEATER
Condition: Improper Installation
Due 22 February 2002
Resolved 22 February 2002
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 22 February 2002
Resolved
PROPERLY LOG ALL TRAINING, DRILLS, RADIO COMMUNICATIONS AND TRASH DISPOSAL.
Condition: Improper/Lack of Maintenance
Due 22 February 2002
Resolved 22 February 2002
Resolution: HELD TRAINING ON LOG REQUIREMENTS
Construction/Loadline › Structures › Door
Issued 22 February 2002
Resolved
PRIOR TO SAILING PROPERLY ADJUST ALL WATERTIGHT DOORS
Condition: Improper/Lack of Maintenance
Due 22 February 2002
Resolved 22 February 2002