MAURY USCG vessel records Sign in
← All vessels

SUN EXPRESS

SUN EXPRESS is a 1965 freight ship. The Coast Guard has recorded 40 inspections since 1981, most recently in January 2012, along with 106 deficiencies and 1 operational control.

Records from 1981 to 2012. Most recent: inspection, 27 January 2012.

Built
1965
Last inspected
27 January 2012
Documentation
Invalid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7126504 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
DOMINICA
—
Maury page id
psix-53259

Inspections, by type

…with no type recorded31
Years with a record 18 calendar years (1981–2012)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Registered dimensions (L × B × D)153.4 ft × 36.0 ft × 11.9 ft
Registered tonnagegross 393 / net 118
ITC dimensions (L × B × D)46.8 ft × 11.0 ft × 3.6 ft
ITC tonnagegross 393 / net 118
Builderbuilder not recorded · NEW ORLEANS, LA, UNITED STATES · built 1965
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNot recorded
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationInvalid
Service, as the file records itFreight Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it118 - Convention (Subpart B), Net Ton
393 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 40

27 January 2012 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 4232994
7 January 2004 Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1978687
24 October 2003 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1935064
5 July 2003 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1834953
4 June 2003 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1806763
21 May 2003 Passenger/Freight Vessel Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1798314
13 September 2002 Deficiency Check
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1674837
24 June 2002 Annual Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1635457
22 December 2001 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1479607
7 June 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 290866
14 May 2001 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 290053
20 April 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 289341
9 July 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 279747
9 June 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 278722
5 May 2000 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 277570
21 June 1999 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 429863
15 April 1999 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 427611
29 March 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 427030
18 November 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 422208
2 March 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 413312
6 February 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 412486
23 September 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 383376
30 July 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 381631
12 July 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 380513
12 October 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 371840
12 October 1994 MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1177630
15 August 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 369493
13 July 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 368522
13 July 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 864231
30 November 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 362748
30 June 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 361806
23 July 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 652636
13 February 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 342077
25 September 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 332837
3 March 1988 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 321764
24 May 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 478765
12 November 1986 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 312659
17 August 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1308431
22 July 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273711
17 August 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275814

Deficiency record · 106

Fire Fighting › Fire Main › Condition
Issued 7 January 2004 Resolved
Make permanent repairs to leaking fire main in engine room overhead.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2012
Deck/Cargo › Ballast › Tank
Issued 7 January 2004 Resolved
Make permanent repairs to #7 port ballast tank fwd bulkhead.
Action required: 15 - Rectify deficiencies by next port
Due 7 January 2004
Resolved 27 January 2012
Deck/Cargo › Ballast › Tank
Issued 7 January 2004 Resolved
Make permanent repairs to #7 port ballast tank longitudial bulkhead inway of passage bilge. Found soft patch.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2012
Construction/Loadline › Hull › Side Shell
Issued 7 January 2004 Resolved
Make permanent repairs to steering gear room hull plating port aft. Currently plugged with wood and cloth.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2012
Electrical › Lighting (emergency) › Lighting Feeder
Issued 7 January 2004 Resolved
Prove proper operation of normal and emergency lighting in super structure house and throughout ship.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2012
Deck/Cargo › Ballast › Tank
Issued 7 January 2004 Resolved
Make permanent repairs to holed inboard bulkhead to #4 port ballast tank.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2012
Stability › Watertight Integrity › General
Issued 7 January 2004 Resolved
Prove proper operation of all water tight and weather tight doors.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2012
Navigation › Emergency Steering › Communications to Emergency Steering
Issued 7 January 2004 Resolved
Prove proper operation of emergency steering with block and tackle. To satisfaction of flag state.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2012
Construction/Loadline › Hull › Longitudinal Frame
Issued 7 January 2004 Resolved
Make permanent repairs to fractured hull transverse and logitudial stiffner (support) inway of port vertical I-beam in steering room.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2012
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 7 January 2004 Resolved
Remove all stored acid batteries from starboard, forward main deck storage compartment.
Due 21 January 2004
Resolved 27 January 2012
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 7 January 2004 Resolved
Properly secure 220V electrical outlet box located inside starboard forward main deck storage.
Due 21 January 2004
Resolved 27 January 2012
Accommodation/Occupational Safety › Messroom › Location
Issued 7 January 2004 Resolved
Remove all stored flammable liquids from starboard shelves in galley/messroom area.
Due 21 January 2004
Resolved 27 January 2012
Construction/Loadline › Penetrations › Weld
Issued 7 January 2004 Resolved
Renew wasted vent for main deck accomodation rest room.
Due 21 January 2004
Resolved 27 January 2012
Electrical › Lighting (service) › Lighting Fixture
Issued 7 January 2004 Resolved
Provide and install globes and guards for all electrical light fixtures found missing.
Due 21 January 2004
Resolved 27 January 2012
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 7 January 2004 Resolved
Renew battery for smoke detector located in 1st deck accomodations passageway.
Due 21 January 2004
Resolved 27 January 2012
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 7 January 2004 Resolved
Provide and install blanks for 110V circuit breaker panel located in galley.
Due 21 January 2004
Resolved 27 January 2012
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 January 2004 Resolved
Make permanent repairs to starboard wheelhouse deck hand rails and stanchions found damaged.
Due 21 January 2004
Resolved 27 January 2012
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 7 January 2004 Resolved
Properly identify and label CO2 audio alarm device location with evacutation instructions.
Due 21 January 2004
Resolved 27 January 2012
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 January 2004 Resolved
Renew starboard wheelhouse deck floating light fixture and mounting bracket for same found broken.
Due 21 January 2004
Resolved 27 January 2012
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 7 January 2004 Resolved
Remove all stored flammable liquids (gasoline, paint etc.) from starboard forward main deck storage compartment.
Due 21 January 2004
Resolved 27 January 2012
Deck/Cargo › Ballast › Piping
Issued 7 January 2004 Resolved
Make permanent repairs to soft-patched ballast suction and discharge piping located in engtine room.
Due 21 January 2004
Resolved 27 January 2012
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 7 January 2004 Resolved
Provide marking for CO2 bottle storage compartment.
Due 21 January 2004
Resolved 27 January 2012
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 7 January 2004 Resolved
Provide and install local operating instructions for fixed CO2 system.
Due 21 January 2004
Resolved 27 January 2012
Operations/Management › Equipment Service/Testing › EPIRB
Issued 7 January 2004 Resolved
Provide servicing certificate for fixed CO2 and all portable extinguishers.
Due 21 January 2004
Resolved 27 January 2012
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 7 January 2004 Resolved
Label starboard forward upper deck fire and safety plan.
Due 21 January 2004
Resolved 27 January 2012
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 January 2004 Resolved
Make permanent repairs to broken screen for #2 SSDG electrical end.
Due 21 January 2004
Resolved 27 January 2012
Construction/Loadline › Structures › End Bulkhead
Issued 7 January 2004 Resolved
Make permanent repairs to holed port engine room entrance inboard bulkhead.
Due 21 January 2004
Resolved 27 January 2012
Stability › Watertight Integrity › General
Issued 7 January 2004 Resolved
Make permanent repairs to holed water tight door for port engine room entrance.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2012
Fire Fighting › Remote Fuel Shutoff › General
Issued 7 January 2004 Resolved
Prove proper operation of port main deck emergency fuel oil shut off. It was found disconnected.
Due 21 January 2004
Resolved 27 January 2012
Deck/Cargo › Ballast › Vents
Issued 7 January 2004 Resolved
Renew wasted main deck vent for #7 starboard ballast tank.
Action required: 15 - Rectify deficiencies by next port
Due 7 January 2004
Resolved 27 January 2012
Engineering › Fuel Oil Service System › Ventilation
Issued 7 January 2004 Resolved
Install screened vent for port fuel oil storage tank vent on main deck.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2012
Documentation › Logs/Records › Enhanced Survey Report File
Issued 7 January 2004 Resolved
Flag state to attest to correction of all outstanding deficiencies and provide fax report to MSD St. Thomas.
Action required: 15 - Rectify deficiencies by next port
Resolved 27 January 2012
Fire Fighting › Fire Main
Issued 21 May 2003 Resolved
PRIOR TP DEPARTURE,REPLACE STANDPIPE ON THE BOW. LEGACY COMPONENT DESC: Condition
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2003
Resolution: REPLACED.
Fire Fighting › Fire Hoses
Issued 21 May 2003 Resolved
Replace fire hose on the emergency fire pump LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2003
Resolution: Replaced
Deck/Cargo › Mooring/Anchoring
Issued 21 May 2003 Resolved
Make STBD anchor free and ready for letting go. LEGACY COMPONENT DESC: Anchor
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2003
Resolution: Anchor freed
Communications › Radio Communications › EPIRB
Issued 21 May 2003 Resolved
Replace expired hydrostatic release for EPIRB
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2003
Resolution: New Hydrostatic release
Personnel › Training › Fire Fighting Basic
Issued 21 May 2003 Resolved
Crew must be able to adequately demonstrate emergency drills
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2003
Resolution: Adequately demonstrate emergency drills
Electrical › Electric Supply System (service)
Issued 21 May 2003 Resolved
Provide rubber matin front of switchboard
Due 21 June 2003
Resolved 5 July 2003
Resolution: corrected
Fire Fighting › Fire Pumps
Issued 21 May 2003 Resolved
Reew fire pump pressure guage
Due 21 June 2003
Resolved 5 July 2003
Resolution: corrected
Navigation › Piloting/Steering
Issued 21 May 2003 Resolved
Provide current compass deviation table LEGACY COMPONENT DESC: Deviation Table/Graph
Condition: Improper/Lack of Maintenance
Due 21 June 2003
Resolved 5 July 2003
Resolution: corrected
Navigation › Piloting/Steering
Issued 21 May 2003 Resolved
Provide current Reeds almanac.
Action required: 15 - Rectify deficiencies by next port
Resolved 21 May 2003
Electrical › Electric Generation Source (service)
Issued 21 May 2003 Resolved
Provide blank covers for openings in the switchboard.
Due 21 June 2003
Resolved 21 June 2003
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 May 2003 Resolved
replace emergency light above port engine.
Due 21 June 2003
Resolved 21 May 2003
Personnel
Issued 13 September 2002 Resolved
Provide flag acceptance of crew licenses and STCW 95 endorsements.
Due 15 April 2003
Resolved 5 July 2003
Resolution: corrected
Fire Fighting › Firemans Outfit
Issued 24 June 2002 Resolved
Provide adequate fireman's outfit.
Due 2 July 2002
Resolved 13 September 2002
Resolution: Attended vessel and verified.
Navigation › Collision/Grounding Avoidance
Issued 24 June 2002 Resolved
Replace broken windshield on Navigation Bridge. LEGACY COMPONENT DESC: Navigation Bridge Visibility
Condition: Damaged By Earlier Event
Due 25 July 2002
Resolved 13 September 2002
Resolution: Attended vessel and verified.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 June 2002 Resolved
Replace Starboard man overboard light bracket.
Due 25 July 2002
Resolved 25 June 2002
Electrical › Lighting (service)
Issued 24 June 2002 Resolved
Provide Light fixtures guards on all exposed lights in engine and steering spaces. LEGACY COMPONENT DESC: Lighting Fixture
Due 25 July 2002
Resolved 13 September 2002
Resolution: Attended vessel and verified.
Engineering › Steering Gear System
Issued 24 June 2002 Resolved
Make permanent repairs to leaking rams, port and starboard. LEGACY COMPONENT DESC: Ram Seal
Due 9 August 2002
Resolved 13 September 2002
Resolution: Attended vessel and verified.
System not recorded
Issued 7 June 2001 Resolved
Provide overspeed decices IAW CCSSC 2.24.3.
Condition: Unknown
Due 7 July 2001
Resolved 22 December 2001
System not recorded
Issued 7 June 2001 Resolved
Update navigational charts.
Condition: Unknown
Due 7 July 2001
Resolved 22 December 2001
System not recorded
Issued 7 June 2001 Resolved
Provide evidence of service of fixed fire fighting system.
Condition: Unknown
Due 7 July 2001
Resolved 22 December 2001
System not recorded
Issued 7 June 2001 Resolved
Make permanent repairs to deck cracks in vicinity of ballast vent five.
Condition: Unknown
Due 26 July 2001
Resolved 22 December 2001
System not recorded
Issued 7 June 2001 Resolved
Make reparis to forward steering space bulkhead below WTD where holed.
Condition: Unknown
Due 26 July 2001
Resolved 22 December 2001
System not recorded
Issued 7 June 2001 Resolved
Make repairs to main longitudal frame in steering space where wasted.
Condition: Unknown
Due 26 July 2001
Resolved 22 December 2001
Unknown
Issued 7 June 2001 Resolved
Provide two additonal fire fighting nozzles in order to meet the appropriate number on the CCSSC certificate.
Condition: Unknown
Due 7 June 2001
Resolved 8 June 2001
System not recorded
Issued 7 June 2001 Resolved
Provide current deviation table.
Condition: Unknown
Due 7 July 2001
Resolved 22 December 2001
System not recorded
Issued 7 June 2001 Resolved
Renew lamp globe aft of the port side wheel house WTD.
Condition: Unknown
Due 7 July 2001
Resolved 22 December 2001
Unknown
Issued 7 June 2001 Resolved
Provide two additional hoses prior to departure.
Condition: Unknown
Due 7 June 2001
Resolved 8 June 2001
System not recorded
Issued 7 June 2001 Resolved
Provide automatic shut off arrangement for main engines and generator IAW CCSSC 2.25.
Condition: Unknown
Due 7 July 2001
Resolved 22 December 2001
System not recorded
Issued 7 June 2001 Resolved
Provide evidence of service to portable extinguishers.
Condition: Unknown
Due 7 July 2001
Resolved 22 December 2001
System not recorded
Issued 7 June 2001 Resolved
Provide two means of communication between the bridge and engine room.
Condition: Unknown
Due 7 July 2001
Resolved 22 December 2001
System not recorded
Issued 7 June 2001 Resolved
Make repairs to transverse steering sapce frames where wasted.
Condition: Unknown
Due 26 July 2001
Resolved 22 December 2001
System not recorded
Issued 7 June 2001 Resolved
Renew port and starboard rudder post support brackets.
Condition: Unknown
Due 26 July 2001
Resolved 22 December 2001
System not recorded
Issued 7 June 2001 Resolved
Renew means to communicate between bridge and steering space.
Condition: Unknown
Due 7 July 2001
Resolved 22 December 2001
System not recorded
Issued 7 June 2001 Resolved
Renew light covers in engine room and steering space as needed.
Condition: Unknown
Due 7 July 2001
Resolved 22 December 2001
System not recorded
Issued 7 June 2001 Resolved
Renew step at engine room entrance, port side cargo deck.
Condition: Unknown
Due 26 July 2001
Resolved 22 December 2001
System not recorded
Issued 7 June 2001 Resolved
Renew wasted horizontal stiffener in fore peak in vicinity of the ladder.
Condition: Unknown
Due 26 July 2001
Resolved 22 December 2001
Construction/Loadline
Issued 5 May 2000 Resolved
Renew ballast suction line in way of temporary repairs.
Condition: Unknown
Due 9 July 2000
Resolved 9 July 2000
Accommodation/Occupational Safety
Issued 5 May 2000 Resolved
Renew wasted steps on starboard bridge ladder.
Condition: Unknown
Due 9 July 2000
Resolved 9 July 2000
Construction/Loadline
Issued 5 May 2000 Resolved
Clean excess oil from the engine room.
Condition: Unknown
Due 9 July 2000
Resolved 9 July 2000
Electrical
Issued 5 May 2000 Resolved
Place guard on rotating machinery on fuel transfer pump in engine room.
Condition: Unknown
Due 9 July 2000
Resolved 9 July 2000
Construction/Loadline
Issued 5 May 2000 Resolved
Renew wasted bulkhead in way of No.1 ballast tank.
Condition: Unknown
Due 9 July 2000
Resolved 9 July 2000
Electrical
Issued 5 May 2000 Resolved
Place guards on rotating machinery on air compressors in engine room.
Condition: Unknown
Due 9 July 2000
Resolved 9 July 2000
Construction/Loadline
Issued 15 April 1999 Resolved
BULKHEADS AND DECK IN FOREPEAK TANK ARE WASTED.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Lifesaving
Issued 29 March 1999 Resolved
REPLACE/RENEW EPIRB.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Documentation
Issued 29 March 1999 Resolved
ENSURE VESSEL IS MANNED IAW SAFE MANNING CERTIFICATE PRIOR TO DEPARTURE.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Documentation
Issued 29 March 1999 Resolved
PROVIDE COPIES OF CREW LICENSES WITH FLAG STATE APPROVAL.
Condition: Unknown
Due 21 June 1999
Resolved 21 June 1999
Fire Fighting
Issued 18 November 1998 Resolved
PRIOR TO DEPARTURE, PROVIDE AND INSTALL A FIXED EXTINGUISHING SYSTEM FOR THE VESSELS ENGINE ROOM AND ENSURE ALL OPENINGS (WTD'S VENT CLOSURES) ARE_x001C_ TIGHT.
Condition: Unknown
Due 23 November 1998
Resolved 23 November 1998
Navigation
Issued 18 November 1998 Resolved
PRIOR TO DEPARTURE, PROVIDE TWO MEANS OF COMMUNICATIONS BETWEEN THE BRIDGE_x001C_AND THE ENGINE ROOM.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Navigation
Issued 18 November 1998 Resolved
PRIOR TO DEPARTURE, PROVIDE ON BOARD A CORRECTED U. S. COAST PILOT 4.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Construction/Loadline
Issued 18 November 1998 Resolved
PRIOR TO DEPARTURE, PROVIDE REPAIR PROPOSAL FROM VESSEL'S FLAG ADMINISTRATION OR AUTHORIZED REPRESENTATIVE ADDRESSING WAISTED AND HOLED MAIN DECK AND NUMEROUS SMALL DUBLER PATCHES. ALSO PROVIDE A CURRENT _x001C_ GUAGING SURVEY REPORT.
Condition: Unknown
Due 23 November 1998
Resolved 23 November 1998
Navigation
Issued 18 November 1998 Resolved
PRIOR TO DEPARTURE, PROVIDE ON BOARD CORRECTED NOAA CHART 11470
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Navigation
Issued 18 November 1998 Resolved
PRIOR TO DEPARTURE, PROVIDE ON BOARD A CORRECTED USCG LIGHT LIST.
Condition: Unknown
Due 18 November 1998
Resolved 18 November 1998
Lifesaving
Issued 6 February 1998 Resolved
Provide a quick release hook for rescue boat bridle, CCSSC 4.6._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 March 1998
Resolved 2 March 1998
Documentation
Issued 6 February 1998 Resolved
Prior to loading cargo, provide complete set of oil transfer procedures (33CFR 155.750).
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Documentation
Issued 6 February 1998 Resolved
Prior to loading cargo, provide written instruction from the company to themaster with policies and procedures for vessel familiarization concerning newly hired crewmembers (STCW Reg I/14).
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Fire Fighting
Issued 6 February 1998 Resolved
Prior to loading cargo, provide an emergency fire pump outside of the machinery space (CCSSC 3.3).
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Engineering
Issued 6 February 1998 Resolved
Prior to loading cargo, provide remote fuel shutoff valves outside of the machinery space (CCSSC 2.25).
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Lifesaving
Issued 6 February 1998 Resolved
Provide 01 PKP fire extinquisher for rescue boat, CCSSC 4.6._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 March 1998
Resolved 2 March 1998
Lifesaving
Issued 6 February 1998 Resolved
Provide oars for rescue boat, CCSSC 4.6._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 March 1998
Resolved 2 March 1998
Fire Fighting
Issued 6 February 1998 Resolved
Prior to loading cargo, provide an additional fire control plan posted for easy access by the crew (CCSSC 2.25).
Condition: Unknown
Due 9 February 1998
Resolved 9 February 1998
Unknown
Issued 30 July 1995 Resolved
Provide a recent survey report including guagings of hull thickness. evidence of excessive corrosion and weld failures were observed in the steering compartment.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Unknown
Issued 30 July 1995 Resolved
Replace or repair the leaking ballast pump. Provide a statement from classverifying the proper operation of same. The pump was observed leaking excessivley through packing glands.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Electrical
Issued 12 July 1995 Resolved
PROVIDE COVERS FOR EXPOSED FLUORESCENT BULBS THROUGHOUT ENGINE ROOM AND ACCOMODATION SPACES.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Electrical
Issued 12 July 1995 Resolved
PROVIDE PROPER FITTING COVER FOR STBD BLOWER CIRCUIT BREAKER BOX.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Navigation
Issued 12 July 1995 Resolved
REPAIR MINOR HYDRAULIC LEAK FROM PORT STEERING RAM SEAL.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Documentation
Issued 12 July 1995 Resolved
PROVIDE UP TO DATE CHARTS, COAST PILOT, LIGHT LIST, TIDE TABLES.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Construction/Loadline
Issued 13 July 1994 Resolved
Vessel has no means to sound there ballast tanks, other than opening the tanks hatch. Provide suitable means to sound ballast tanks.
Condition: Unknown
Due 13 October 1994
Resolved 27 October 1994
Documentation
Issued 13 July 1994 Resolved
The loadline/deckline markings were not permanently marked on the port/starboard side of the vessel as required by 46 CFR 42.07-5(a).
Condition: Unknown
Due 16 August 1994
Resolved 16 August 1994
Construction/Loadline
Issued 13 July 1994 Resolved
Doors forward main deck entrance to engine room were not water tight, as required by 46 C.F.R. 42.15.
Condition: Unknown
Due 16 August 1994
Resolved 16 August 1994
Navigation
Issued 13 July 1994 Resolved
Vessel failed to provide a current deviation table or compass comparison record, as required by SOLAS 74 chapter V reg. 12(b). Compass was last swung 1990.
Condition: Unknown
Due 16 August 1994
Resolved 16 August 1994
Documentation
Issued 13 July 1994 Resolved
Vessel failed to provide a minimum manning certificate issued from flag state, as required by I.A.W. 46 U.S.C. 8301.
Condition: Unknown
Due 16 August 1994
Resolved 16 August 1994
Documentation
Issued 13 July 1994 Resolved
Vessel failed to provide current (2 Yrs.) Medical cerificates issued by flag state. Required by ILO 147.
Condition: Unknown
Due 16 August 1994
Resolved 16 August 1994
Electrical
Issued 13 July 1994 Resolved
THROUGH OUT THE SHIP A FEW LIGHTING FIXTURES WERE MISSING BULBS & GUARDS.
Condition: Unknown
Due 16 August 1994
Resolved 16 August 1994
Documentation
Issued 13 February 1991 Resolved
A VIOLATION OF 33 CFR 155.750 (4)(5)(6)(7))(8) IN THAT THE VESSEL HAS INCOMPLETE OIL TRANSFER PROCEDURES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 June 1991
Resolved 13 February 1991

Ownership record