Records from 1981 to 2009. Most recent: inspection, 26 December 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 49
26 December 2009
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3669972
7 March 2008
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3160123
26 February 2008
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3154542
15 May 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1616922
13 November 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 185134
5 April 1995
Permit to Proceed
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448633
12 May 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1265368
17 December 1991
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357906
4 December 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 942868
27 June 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1229828
13 May 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 904991
9 May 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 922158
6 May 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1341843
22 April 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 919933
25 September 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1228055
4 June 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1219151
1 June 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 907643
10 May 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 930816
29 March 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 920639
10 January 1990
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 917429
16 August 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1043771
19 July 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1343251
11 July 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1343768
1 July 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1035101
11 May 1989
Drydock Extension · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1349103
24 May 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1206785
2 October 1987
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012332
27 August 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320014
27 May 1987
Hull Examination · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1332078
16 May 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1027556
28 July 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300849
8 July 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299645
2 May 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303463
1 May 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296185
27 February 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999274
28 January 1986
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1319616
22 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287908
18 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982204
13 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287907
5 January 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284252
23 August 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285434
18 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280875
30 November 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279646
29 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276260
11 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279381
21 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963481
16 August 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1276762
9 August 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 963670
14 April 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963529
Construction/Loadline
Issued 17 December 1991
Resolved
MAKE APPROVED REPAIRS ON NON-APPROVED 1'X16' INSERT ON PORT AREA OF SIDESHELL. INSERT IS TO BE A MINIMUM OF 18" WITH A MINIMUM OF 6" BELOW INTERNAL DECK PLATE._x001C_ _x001C_
Condition: Unknown
Due 13 January 1992
Resolved 18 December 1991
Construction/Loadline
Issued 6 May 1991
Resolved
PROVIDE PROPER REPAIR OR REPLACE WASTED PIPING OF SALT WATER SUCTION TO VOID TANK IN MUD PUMP ROOM.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Construction/Loadline
Issued 6 May 1991
Resolved
PROVIDE PROPER REPAIR WASTED PIPING IN WAY OF BILGE SUCTION LINE IN MUD PUMP ROOM.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Construction/Loadline
Issued 6 May 1991
Resolved
PROVIDE PROPER REPAIR IN WAY OF PORT SERVICE OUTLET PIPING ON DRILL FLOOR AIR RECEIVER LOCATED UNDER DRILL FLOOR.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Unknown
Issued 22 April 1991
Resolved
DAVIT-LAUNCHED LIFE RAFT SYSTEM INSTALLATION DEADLINE.
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Electrical
Issued 10 May 1990
Resolved
INSTALL A PURGE AND LOSS OF PURGE ALARM ON THE GAS SENSOR PUMP UNIT OF THE DRILL FLOOR OR REMOVE THE UNIT.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Electrical
Issued 10 May 1990
Resolved
PROVIDE AN EXPLOSION PROOF SWITCH FOR THE GENERAL ALARM CONTACT MAKER IN THE DOGHOUSE.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Documentation
Issued 10 May 1990
Resolved
CORRECT THE LOAD LINE CERT. SO THAT THE ENDORSEMENT REFERENCES THE STABILITY LETTER DATED 16 APRIL 1984.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Fire Fighting
Issued 10 May 1990
Resolved
SHOW CALCULATIONS FOR THE AMOUNT OF CO2 REQUIRED FOR THE PAINT LOCKER.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Electrical
Issued 10 May 1990
Resolved
REPAIR THE LOSS OF PURGE ALARM ON THE DRILLERS CONSOLE AMMETER.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Electrical
Issued 10 May 1990
Resolved
REPAIR THE KICKPIPES OUTSIDE THE STBD. JACKHOUSE FOR THE ELECTRICAL SWITCHES (GENERAL ALARM, EMERGENCY SHUTDOWNS, ECT...)
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Lifesaving
Issued 10 May 1990
Resolved
RENEW THRE STBD. AFT WINDOW IN THE PORT CAPSULE.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Electrical
Issued 10 May 1990
Resolved
REPAIR THE DRILLERS TV MONITOR LOSS OF PURGE ALARM OR REMOVE THE UNIT.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Electrical
Issued 10 May 1990
Resolved
REPAIR THE LOSS OF PURGE ALARM ON THE STROKE COUNTER IN THE DRILLERS CONSOLE.
Condition: Unknown
Due 10 May 1990
Resolved 10 May 1990
Construction/Loadline
Issued 10 January 1990
Resolved
PROVIDE GAGINGS OF THE SIDE SHALL IN THE HALIBURTON ROOM. SHOTS TO BE IN THE HORIZONTAL LINES (1) AT THE DECK (2) MIDWAY & (3) AT THE OVERHEAD INTERSECTION TO THE BULKHEAD.
Condition: Unknown
Due 10 January 1990
Resolved 10 January 1990
Construction/Loadline
Issued 10 January 1990
Resolved
MAKE PROPER REPAIR AT BHD. #3 IN SACK ROOM WERE DOUBLER IS PRESENT, REPAIR TO BE MADE AND SIZED TO GOOD METAL. MINIMUM SIZE OF REPAIR IS TO BE 18"X18"
Condition: Unknown
Due 10 January 1990
Resolved 10 January 1990
Construction/Loadline
Issued 10 January 1990
Resolved
PROVIDE BELT GAGINGS OF THE BARGE HULL IN 3 LOCATION.
Condition: Unknown
Due 10 January 1990
Resolved 10 January 1990
Construction/Loadline
Issued 10 January 1990
Resolved
PROVIDE A COPY OF THE LAST GAGING REPORT FOR THE MAT, SIDES, DECK, BOTTOM &INTERNAL BULKHEAD.
Condition: Unknown
Due 10 January 1990
Resolved 10 January 1990
Construction/Loadline
Issued 10 January 1990
Resolved
PROVIDE GAGINGS IN WAY OF THE #12 & #15 STBD TANKS. AND #12 & #13 PORT TANKGAGINGS TO BE DONE ON FLOORS, BULKHEADS AND OVERHEAD.
Condition: Unknown
Due 10 January 1990
Resolved 10 January 1990
Construction/Loadline
Issued 10 January 1990
Resolved
PROVIDE BULKHEAD AND DECK GAGINGS IN WAY OF THE MACHINERY SPACE ON THE PORTSIDE.
Condition: Unknown
Due 10 January 1990
Resolved 10 January 1990
Construction/Loadline
Issued 10 January 1990
Resolved
PROVIDE GAGINGS FOR THE BULKHEAD BETWEEN THE MUD PUMP ROOM AND THE MUD PITS.
Condition: Unknown
Due 11 May 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 10 January 1990
Resolved
PROVIDE GAGINGS OF THE ORIGINAL STUBS FROM THE MAT TO THE FIRST SECTION OF NEW LEGS.
Condition: Unknown
Due 10 January 1990
Resolved 10 January 1990
Construction/Loadline
Issued 1 July 1989
Resolved
PROVIDE GUAGEINGS FOR OVERHEAD FRAMING IN VOID 12 STARBOARD, FRAMING IS WASTED THROUGH IN WAY OF VENT LINE IN OVERHEAD.
Condition: Unknown
Due 1 July 1989
Resolved 1 July 1989
Fire Fighting
Issued 1 July 1989
Resolved
RESOLVE PROBLEM WITH LOSS OF FIREMEN PRESSURE ON PORT SIDE FIRE STATIONS.
Condition: Unknown
Due 1 July 1989
Resolved 1 July 1989
Accommodation/Occupational Safety
Issued 1 July 1989
Resolved
MAKE AIR RECEVIERS AND BULK/CEMENT TANKS AVAILABLE FOR INTERNAL INSPECTION BY A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 1 July 1989
Resolved 1 July 1989
Electrical
Issued 1 July 1989
Resolved
RENEW THE OUTBOARD BATTERY OF THE GENERAL ALARM BATTERY BANK. GENERAL OPERATIONAL BUT AFTER TESTING, BATTERY TESTED LOW VOLTAGE.
Condition: Unknown
Due 1 July 1989
Resolved 1 July 1989
Electrical
Issued 1 July 1989
Resolved
PROVIDE EVIDENCE THAT DRILLERS DUAL DISPLAY IS INTRINSICALLY SAFE OR AIR PURGE TO CONFORM TO REQUIREMENTS OF A CLASS T DIVISION II LOCATION, THIS IS DIRECTIONAL DRILLING EQUIPTMENT.
Condition: Unknown
Due 1 July 1989
Resolved 1 July 1989
Electrical
Issued 1 July 1989
Resolved
REMOVE TYPE "SO" CABLE FROM ELECTRICAL ROOM AND LOGGER'S SHACK. COMPLY BY DATE:11JUN89
Condition: Unknown
Due 1 July 1989
Resolved 1 July 1989
Lifesaving
Issued 1 July 1989
Resolved
PROVIDE STANDBY BOAT CONSTANTLY 24 HOURS/DAY NOT GREATER THAN 1/2 NAUTICAL MILE FROM RIG UNTIL CAPSULE#1 IS REPAIRED. NOTIFY STANDBY BOAT OF HIS STATUS AS AN EXCLUSIVE LIFESAVING PLATFORM. CONDUCT COMMS CHECK W/STBY BOAT EVERY 30 MIN. AND LOG.
Condition: Unknown
Due 1 July 1989
Resolved 1 July 1989
Unknown
Issued 27 May 1987
Resolved
CONDUCT A FIRE AND BOAT DRILL UPON ARRIVAL ON LOCATION AND LOG THE SAME.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Electrical
Issued 27 May 1987
Resolved
TEST EMERGENCY SHUTDOWNS AND PROTECTION DEVICES FOR THE NUMBER ONE SERVICE GENERATOR.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Lifesaving
Issued 27 May 1987
Resolved
MAKE PORT LIFE CAPSULE READY FOR WEIGHT TEST - EXAMINE DAVIT ASSEMBLY, DISENGAGING APPARATUS, AND FALLS.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Unknown
Issued 27 May 1987
Resolved
PROPERLY SECURE/SUPPORT ELECTRICAL CABLES IN THE SHALESHAKER AREA.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Unknown
Issued 27 May 1987
Resolved
PROVIDE A HEAT RESISTANT GLASS GAUGE FOR THE FUEL OIL DAY TANK IN THE ENGINE ROOM.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Unknown
Issued 27 May 1987
Resolved
EXERCISE BOTH LIFE CAPSULES IN THE WATER.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Unknown
Issued 27 May 1987
Resolved
TEST THE BILGE EJECTOR SYSTEM.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Unknown
Issued 27 May 1987
Resolved
MAKE THE MARINE SANITATION DEVICE OPERABLE.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Unknown
Issued 27 May 1987
Resolved
REPAIR THE WASTED COAMING IN THE SHALESHAKER AREA.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Unknown
Issued 27 May 1987
Resolved
REPLACE THE WASTED NUTS AND BOLTS ON THE DERRICK LEGS.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Fire Fighting
Issued 27 February 1986
Resolved
LABLE BOX ON DRILL FLOOR THAT HOLDS THE SELF CONTAINED BREATHING APPARATUS.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Electrical
Issued 27 February 1986
Resolved
ADJUST GENERAL ALARM BELL ON DRILL FLOOR, AND PROVIDE DUCT SEAL PUTTY ON EYS FITTINGS ON DRILL FLOOR.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Construction/Loadline
Issued 27 February 1986
Resolved
INSTALL NUTS ON BOLTS ON MAN HOLE HATCH COVER LOCATED PORT SIDE, AFT, MAN DECK.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Navigation
Issued 27 February 1986
Resolved
REMOVE STANDING WATER FROM FOG HOUR BATTERY BOX.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Fire Fighting
Issued 27 February 1986
Resolved
LABLE ON/OFF SWITCHES TO SALT WATER PUMPS AS "FIRE PUMPS".
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Construction/Loadline
Issued 27 February 1986
Resolved
ADJUST WATERTIGHT DOORS TO ACCOMMODATION SPACES.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Construction/Loadline
Issued 27 February 1986
Resolved
ADJUST WATERTIGHT DOORS TO ACCOMMODATION SPACES.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Fire Fighting
Issued 27 February 1986
Resolved
PLUG HOLES IN STARWAY INUSE TO CO2 ROOM, LOCATED ON THE STABD SIDE, AFT. HOLES ARE WHERE ELECTRICAL WIRES HAVE PENETRATED STARWAY BULKHEAD.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Fire Fighting
Issued 27 February 1986
Resolved
LABLE GENERAL ALARM BELL AND CELLER DECK. ALSO MAKE OPERABLE SAME BELLS.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Lifesaving
Issued 27 February 1986
Resolved
PROVIDE FIFTEEN TRIANGULAR BANDAGES AND ONE TOURNIQUET FOR MEDICAL CHEST.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Navigation
Issued 27 February 1986
Resolved
PAINT SCREENS FOR NAVIGATION LIGHTS "MAT" BLACK.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Electrical
Issued 27 February 1986
Resolved
PERFORM LOAD TEST ON EMERGENCY LIGHTING SYSTEM, 46 CFR 109.211.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Accommodation/Occupational Safety
Issued 27 February 1986
Resolved
SUBMIT FOR APPROVAL THE USE OF FIBERGLASS GRATINGS IN MACHINERY SPACES, MUDPIT ROOMS, SHALE SHAKER, MUD CLEANER UNITS, AND OUTSIDE DECK AREAS.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Electrical
Issued 27 February 1986
Resolved
INSTALL COVERS ON ELECTRICAL JUNCTION BOXES AT ENDS OF OVENHEAD FLUORESCENTLIGHT FIXTURES LOCATED IN ENGINE ROOM NEXT TO ENGINE NO. 1 & 3.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Engineering
Issued 27 February 1986
Resolved
CROP AND RENEW AS NECESSARY WASTED AND LEAKING COOLING WATER PIPING TO DIESEL ENGINES IN ENGINE ROOM. TO BE COMPLETED NOT LATER THAN NEXT RIG MOVE.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Electrical
Issued 27 February 1986
Resolved
INSTALL ELECTRICAL INSULATION MATS IN FRONT OF MOTOR CONTROLLER IN ENGINE ROOM AND MOTOR CONTROLLER CENTER IN EVAPORATOR ROOM.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Accommodation/Occupational Safety
Issued 23 August 1984
Resolved
MAKE REPAIRS TO DUMP LINE IN #15 VOID. REWELD AND TEST
Condition: Unknown
Due 23 August 1984
Resolved 23 August 1984
Unknown
Issued 23 August 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL OCEAN STAR CG000140
Condition: Unknown
Due 23 August 1984
Resolved 23 August 1984
Lifesaving
Issued 18 April 1984
Resolved
PROVIDE PORTABLE, WATERTIGHT, AND NONCORROSIVE CONTAINER FOR RED PARACHUTE FLARES, 46CFR108.521.
Condition: Unknown
Due 18 April 1984
Resolved 18 April 1984
Deck/Cargo
Issued 18 April 1984
Resolved
PROVIDE ASME 40 PSI RELIEF VALVES ON EACH BULK TANK, 46CFR54.15.
Condition: Unknown
Due 18 April 1984
Resolved 18 April 1984
Lifesaving
Issued 18 April 1984
Resolved
SCRAMBLE NETS ON BOW DO NOT COMPLY WITH 46CFR108.525. ITEM PENDS COMMANDANT APPROVAL OF INSTALLATION.
Condition: Unknown
Due 18 April 1984
Resolved 18 April 1984
Lifesaving
Issued 18 April 1984
Resolved
PROVIDE NON-EXPIRED SMOKE FLOATS FOR LIFESAVING CAPSULES, 46CFR108.501.
Condition: Unknown
Due 18 April 1984
Resolved 18 April 1984
Unknown
Issued 18 April 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU OCEAN STAR, CG000140
Condition: Unknown
Due 18 April 1984
Resolved 18 April 1984
Fire Fighting
Issued 18 April 1984
Resolved
PROVIDE LOSS OF VENTILATION ALARM FOR MUD PIT VENTILATION SYSTEM. ALARM ISTO SOUND IN A NORMALLY MANNED AREA, 46CFR108.175.
Condition: Unknown
Due 18 April 1984
Resolved 18 April 1984
Accommodation/Occupational Safety
Issued 29 April 1983
Resolved
PROVIDE RELIEF VALVES WITH HAND RELIEVING GEAR FOR TWO 250 PSI START AIR RECIEVERS AND TEST IN PRESENCE OF A CG INSPECTOR.
Condition: Unknown
Due 29 April 1983
Resolved 29 April 1983
Accommodation/Occupational Safety
Issued 29 April 1983
Resolved
MAKE RIG AIR RECIEVER UNDER DRILL FLOOR AVAILABLE FOR (A) INTERNAL IINSPEC-TION, B) TEST OF RELIEF VALVE, C) PROVIDE WITH OPERATIONAL PRESSSURE GUAGE.
Condition: Unknown
Due 29 April 1983
Resolved 29 April 1983
Documentation
Issued 29 April 1983
Resolved
PROVIDE OPERATING MANUAL AND STABILITY LETTER ABOARD VESSEL.
Condition: Unknown
Due 29 April 1983
Resolved 29 April 1983
Unknown
Issued 29 April 1983
Resolved
PROVIDE GUARDS FOR DIESEL OIL DAY TANK SIGHT GLASS IN GENERATOR ROOM.
Condition: Unknown
Due 29 April 1983
Resolved 29 April 1983
Construction/Loadline
Issued 29 April 1983
Resolved
SECURE DRILL WATER LINE TO MUD PIT PORT SIDE AND REMOVE TRIP PINE HAZARD.
Condition: Unknown
Due 29 April 1983
Resolved 29 April 1983
Construction/Loadline
Issued 29 April 1983
Resolved
REPOSITION MUD PIT DOOR AUTOMATIC CLOSURES AND FAIRLEAD CABLE ALONG OVERHEAD.
Condition: Unknown
Due 29 April 1983
Resolved 29 April 1983
Electrical
Issued 29 April 1983
Resolved
PROVIDE SPACE BLANKS IN DISTRIBUTION PANELS NO.5 AND NO.11.
Condition: Unknown
Due 29 April 1983
Resolved 29 April 1983
Electrical
Issued 29 April 1983
Resolved
PROVIDE GUARDS ON BUNK LIGHTS IN ROOM 25.
Condition: Unknown
Due 29 April 1983
Resolved 29 April 1983
Electrical
Issued 29 April 1983
Resolved
PROVIDE GUARDS ON OVERHEAD LIGHTS IN LINEN ROOM, JANITOR ROOM, STOREROOM 30STOREROOM FIRST DECK AND REEFER.
Condition: Unknown
Due 29 April 1983
Resolved 29 April 1983
Navigation
Issued 29 April 1983
Resolved
CLEAN ALL NAVIGATION LIGHT AND OBSTRUCTION LIGHT LENSES.
Condition: Unknown
Due 29 April 1983
Resolved 29 April 1983
Documentation
Issued 29 April 1983
Resolved
SUBMIT OPERATING MANUAL AND STABILITY CALCULATIONS TO CCGD8(MMT).
Condition: Unknown
Due 29 April 1983
Resolved 29 April 1983
Accommodation/Occupational Safety
Issued 29 April 1983
Resolved
MAKE THE 150 PSI RIG AIR RECIEVER IN THE AIR COMPRESSOR ROOM (FWD) AVAILABLE FOR A) INTERNAL EXAM.,B) TEST OF RELIEF VALVE.
Condition: Unknown
Due 29 April 1983
Resolved 29 April 1983
Accommodation/Occupational Safety
Issued 29 April 1983
Resolved
MAKE THE 150 PSI AIR RECEIVER IN THE AFT COMPRESSOR ROOM AVAILABLE FOR IN- TERNAL EXAM AND PROVIDE A CG APPROVED RELIEF VALVE.
Condition: Unknown
Due 29 April 1983
Resolved 29 April 1983
Accommodation/Occupational Safety
Issued 29 April 1983
Resolved
MAKE THE RIG AIR RECEIVER IN THE MECHANICS ROOM AVAILABLE FOR INTERNAL EXAMAND TEST OF RELIEF VALVE.
Condition: Unknown
Due 29 April 1983
Resolved 29 April 1983
Electrical
Issued 29 April 1983
Resolved
MAKE OPERABLE NO.1 AND NO.2 FUEL TRANSFER PUMP SHUTDOWNS BY STARBOARD JACK HOUSE AND LABLE SAME.
Condition: Unknown
Due 29 April 1983
Resolved 29 April 1983