TRITON CRUSADER

TRITON CRUSADER is a 1981 industrial vessel. The Coast Guard has recorded 63 inspections since 1981, most recently in March 2026, along with 88 deficiencies and 3 casualty investigations between 2001 and 2013.

Records from 1981 to 2026. Most recent: inspection, 11 March 2026.

Built
1981
Last inspected
11 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8023840 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDK2223
Flag
UNITED STATES
367346050
Maury page id
psix-53268

Inspections, by type

…with no type recorded10
Years with a record 34 calendar years (1981–2026)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)171.8 ft × 40.0 ft × 15.0 ft
Registered tonnagegross 286 / net 194
ITC dimensions (L × B × D)171.8 ft × 40.0 ft × 15.0 ft
ITC tonnagegross 991 / net 297
BuilderHALTER MARINE INC · LOCKPORT, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 16 September 2025 · expires 31 October 2026
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it286 - Regulatory (Subpart C or D), Gross Ton
991 - Convention (Subpart B), Gross Ton
194 - Regulatory (Subpart C or D), Net Ton
297 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDK2223MMSI 367346050 · active · compulsorily equipped · granted 18 April 2018, expires 18 April 2028
WDE3923MMSI 367346050 · terminated · compulsorily equipped · granted 29 March 2008, cancelled 17 April 2018
WDB6424MMSI 338022000 · cancelled · compulsorily equipped · granted 10 February 2004, cancelled 29 May 2007
WCW4541MMSI not assigned · cancelled · compulsorily equipped · granted 19 April 1996, cancelled 26 August 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 63

11 March 2026 Vessel Attendance · Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8308374
30 January 2026 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8296587
26 June 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8166962
22 March 2024 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7883565
3 March 2023 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7644939
17 January 2023 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7624131
23 June 2022 Deficiency Check · Annual Inspection · Commercial Dive Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7484168
14 February 2022 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7396355
30 March 2021 Internal Structural Exam · In-Service Inspection · Periodic Inspection · Commercial Dive Inspection · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7165756
9 July 2020 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7001060
1 August 2019 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6773441
16 April 2019 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6663735
2 May 2018 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6404805
23 March 2018 Internal Structural Exam · Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6377160
5 July 2017 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6198705
15 May 2017 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6147246
31 March 2016 Periodic Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5845188
17 March 2016 Hull Examination · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5842683
13 June 2014 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4894420
2 September 2010 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3840607
18 December 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3381965
16 October 2008 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3346010
30 July 2007 Construction Oversight · Hull Examination · COI Inspection · Cargo Tank Internal · Commercial Dive Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3012686
5 October 2004 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2214146
2 December 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 84364
21 November 2001 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 773148
19 October 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1384907
12 July 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1068216
24 April 2001 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1062355
18 April 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 58947
18 April 2001 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399597
12 September 2000 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424973
9 June 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1052927
10 November 1999 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 804317
14 May 1999 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1381598
26 May 1998 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1464101
29 September 1997 Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 786044
7 August 1997 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 782070
17 May 1997 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1416508
21 June 1996 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1080834
15 April 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 651286
9 April 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 147788
1 July 1995 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458229
1 June 1995 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1398262
29 November 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 867384
9 September 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354922
26 May 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 854224
28 July 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446003
28 September 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395874
19 August 1992 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410747
30 July 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 938362
29 October 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1223725
8 June 1990 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1230984
3 August 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 886567
12 September 1988 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1042900
14 September 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318112
7 August 1987 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1339233
22 May 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1333606
30 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 981881
24 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286377
16 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286374
9 June 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968004
29 May 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276945

Deficiency record · 88

07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 March 2026 Resolved
Oil strainers, and other equipment subject to normal oil leakage must be fitted with drip pans or other means to prevent oil draining into the bilge. The oil filters fin the Jet Pump Room did not have drip pans. 46 CFR 96.03-1 "Old I" 46 CFR 56.50-60 (k)
Action required: 10 - Deficiency Rectified
Resolved 11 March 2026
Resolution: Drip pans were placed under the oil filters.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 March 2026 Resolved
Cable penetrations required to be watertight should be checked for proper packing of the terminal or stuffing tubes. Cable penetrations in the Jet Pump room and Engine room had 2 wires through a single cable penetration, preventing watertight seal. 46 CFR 96.05-1 "Old I" 46 CFR 111.05-10 (c)(3) "Old-Old J"
Action required: 10 - Deficiency Rectified
Resolved 11 March 2026
Resolution: Additional Cable penetrations were added to allow for a complete seal on each.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 11 March 2026 Resolved
There shall be at least two means of escape from all general areas accessible to the passengers, if carried, or where the crew may be quartered or normally employed. The watertight door designated as the "Hobbit Door" was not effectively operable.
Action required: 10 - Deficiency Rectified
Resolved 11 March 2026
Resolution: The watertight door was adjusted to be able to work from both sides.
04 - Emergency Systems › N/A - No Subsystem › Emergency steering position com./ compass reading
Issued 11 March 2026 Resolved
Instructions in at least 1/2 inch letters and figures shall be posted in the steering engine room, relating in order, the different steps to be taken in changing to the emergency steering gear. The posted instructions on board did not match the required steps needed to shift to emergency steering. 46 CFR 97.37-33 "Old I"
Action required: 10 - Deficiency Rectified
Resolved 11 March 2026
Resolution: Instructions were updated.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 11 March 2026 Resolved
Means shall be provided for stopping all fans in ventilation systems serving machinery and cargo spaces for closing all doorways, ventilators and annular spaces around funnels and other openings to such spaces from outside these spaces, in case of fire. The Port ventilation fan to the engine room did not shut down upon activation of the shutdown switch. 46 CFR 92.15-10 (b) "Old I"
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 March 2026
Resolution: EMT Electronics tech repaired the ventilation shutdown; test sat.
11 - Life Saving Appliances › N/A - No Subsystem › Fast Rescue Boats
Issued 26 June 2025 Resolved
Each survival craft, except for inflatable craft, must be stripped, cleaned, and thoroughly inspected and repaired, as needed, at least once each year and each fuel tank must be emptied, cleaned, and refilled with fresh fuel. Vessel has not conducted annual inspection on rescue boat. 46 CFR 199.10(h) 46 CFR 199.190
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2025
Resolved 30 June 2025
Resolution: Vessel POC provided invoice from Donavan Marine dated 15FEB25 proving that the onboard rescue boat was newly purchased – renewed/ in kind within the year.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 June 2025 Resolved
Oil piping drains, strainers, and other equipment subject to normal oil leakage must be fitted with drip pans or other means to prevent oil draining into the bilge. Fuel filters were not fitted with drip pans. 46 CFR 90.20-1 (OLD I) 46 CFR 56.50-60
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2025
Resolved 27 June 2025
Resolution: All fuel filters were fitted with drip pans.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 June 2025 Resolved
When a ship is located in a special area, food wastes shall only be discharged while the ship is en route, not less than 12 nautical miles from the nearest land, and after having been processed with a grinder or comminuter. The vessel is not equipped with a grinder or comminuter and has not been properly processing food for discharge at sea within the GOM (GOA), a special area. 33 CFR 151.71
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2025
Resolved 2 July 2025
Resolution: The vessel POC provided sheet where the crew received training on garbage management – particularly the proper disposal of food waste within the GOM/GOA, a Special Area. See narrative for more detail.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 26 June 2025 Resolved
The owner of a vessel shall ensure such vessel is equipped with a vessel master key control system, manual or electronic, which provides controlled access to all copies of the vessel's master key. Vessel does not have a master key control log or record book for on board. keys. 46 USC 3106
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2025
Resolved 23 July 2025
Resolution: received updated company policy for the TRITON CRUSADER that no keys would be onboard to be issued. No Master Keys. The Master Key control policy (implemented into their procedure) is that no keys will be issued or available for any vessel crews. Attached
09 - Working and Living Conditions › 091 - Living Conditions › Ventilation (Accommodation)
Issued 26 June 2025 Resolved
Accommodations provided on all vessels shall be securely constructed and ventilated and, where practicable, insulated from undue noise and effluvia. Port deck ventilation closure was missing a cover. 46 CFR 92.20-5 (OLD I)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2025
Resolved 27 June 2025
Resolution: The port deck ventilation closure cover was verified renewed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 June 2025 Resolved
No repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment shall be made without the knowledge of the Officer in Charge, Marine Inspection. Complete repairs to the water heater support prior to next drydock credit. 46 CFR 91.45-1 (OLD I)
Action required: 705 - Other - as specified
Due 26 July 2025
Resolved 3 March 2026
Resolution: Vessel conducted adequate repairs to the hot water heater support bracket, replacing most of the original structure.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 26 June 2025 Resolved
Each ring life buoy must be of an approved type. Port and starboard bridge buoys were not the correct weight (2.5 kg deck buoys were utilized). Correctly weighted bridge buoys were put into place during MI attendance. 46 CFR 94.43-5 (OLD I)
Action required: 10 - Deficiency Rectified
Due 26 June 2025
Resolved 26 June 2025
Resolution: Correctly weighted bridge buoys were put into place during MI attendance.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 26 June 2025 Resolved
Inflatable liferafts shall be stowed in such a manner that they will float free in the event of the vessel sinking. Two starboard life rafts and one port life raft painter lines were not properly attached to the hydrostatic release weak link. All rafts were in correct float-free arrangement prior to MI departure. 46 CFR 94.15-10 (OLD I)
Action required: 10 - Deficiency Rectified
Due 26 June 2025
Resolved 26 June 2025
Resolution: All rafts were in correct float-free arrangement prior to MI departure.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 26 June 2025 Resolved
For vessels assigned a load line, special requirements as to strength, closure of openings, etc are subject to subchapter E (Load Lines). 04 watertight doors on vessel did not maintain watertight boundary. All 04 doors were adjusted to satisfaction prior to MI departure. 46 CFR 92.01-5 (OLD I)
Action required: 10 - Deficiency Rectified
Due 26 June 2025
Resolved 26 June 2025
Resolution: All 04 doors were adjusted to satisfaction prior to MI departure.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 22 March 2024 Resolved
There must be an individual with an MMC endorsed as chief engineer also holding an STCW Endorsement. Chief engineer did not hold STCW endorsements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2024
Resolved 3 April 2024
Resolution: Submitted all documentation for updated license.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for rating for watchkeeping
Issued 22 March 2024 Resolved
On a seagoing vessel of 500GT or more, no person may employ or engage any person to serve as an RFPNW unless person holds valid STCW endorsements. AB + OS do not hold appropriate STCW endorsements.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2024
Resolved 3 April 2024
Resolution: Submitted all documentation for updated licenses.
01 - Certificates & Documentation › 013 - Documents › Records of seafarers' daily hours of work or rest
Issued 22 March 2024 Resolved
Records of daily hours of rest must be maintained onboard the vessel. Rest logs did not accurately reflect work completed as referenced in drill and rough logs. Clear at next topside
Action required: 705 - Other - as specified
Resolved 26 June 2025
Resolution: Spot checked / reviewed vessel work/ rest records to clear the item.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 22 March 2024 Resolved
Each survival craft must be stowed so that it can be launched without lifting more than one foot. Liferaft that was easily transferable was in a position where it would need to be lifted over one foot to launch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2024
Resolved 3 April 2024
Resolution: Stand built to remove need to lift liferaft >12" when launching.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 March 2024 Resolved
Pressure indicating gauges shall be 1.2 - 2.0x the relieving pressure. Gauges on PVHO's were not in appropriate range.
Action required: 10 - Deficiency Rectified
Resolved 22 March 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 22 March 2024 Resolved
The assignment of load lines is conditioned upon the provision provided on the vessel for that of her protection of vessel and crew. Watertight doors were not closing and load line was not appropriately marked.
Action required: 10 - Deficiency Rectified
Resolved 22 March 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 April 2023 Resolved
Exhaust pipes shall conform to the standards. Exhaust leak on the port MDE (center).
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2023
Resolution: Crew tightened and inspector attended to verify not leaking.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 April 2023 Resolved
At least 2 lifebuoys on the vessel must be fitted with self activating smoke signal. Port arrangement would not allow the device to deploy into the water.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 April 2023
Resolution: Smoke replaced and a chain added so the door doesnt go staight down, now allowing ring buoy to slide out clearing vessel with attachements. Witnessed test on port and STBD.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2023 Resolved
Flammable liquids shall be stowed in a paint locker. Flammable liquids found in accommodation spaces
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 April 2023
Resolution: Materials moved to locker.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 3 April 2023 Resolved
Periodic safety test procedures must be submitted to the Coast Guard for approval. Procedures on board had been previously witnessed by the OCMI but were not submitted to MSC for final approval. Submit test procedures to MSC.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 July 2025
Resolution: Vessel POC provided proof of auto email reply that they had submitted the vessel PSTPs back to MSC. Attached it deficiency documents tab.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 3 April 2023 Resolved
Rescue boat must be marked as follows: each side of the bow marked with vessel name, hailing port, and number of persons boat is equipped for. Rescue boat was not marked properly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 April 2023
Resolution: Verified markings.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 3 April 2023 Resolved
Class-1 watertight doors are designed to withstand a head of water equivalent to the depth from the sill of the door to the bulkhead deck. Compressor room emergency escape and fwd engine room door did not have the proper gasket material. Adjust all watertight doors.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 4 April 2023
Resolution: Doors adjusted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2023 Resolved
Electrical circuits shall be protected from accidental contact. MSD blower motor junction box missing cover and distribution panel in bow thruster compartment missing blank.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 April 2023
Resolution: Verified blank and cover replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 23 June 2022 Resolved
Each Class 1 door on a vsl in ocean service must be designed to withstand a head of water no less than 10 feet; three (03) watertight doors called out needing fixed: 1. Engine room to rudder room horizontal dogs not making proper contact with striker plate; 2. Gasket for engine room to jet pump room needs replaced; 3. Engine room port escape was wasted; not watertight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2022
Resolution: Wateright doors repaired to the satisfaction of the MI.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 June 2022 Resolved
Navigation rules concerning lights shall be complied with from sunset to sunrise; vessel's 'Not Under Command' light was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 June 2022
Resolution: Vessel replaced bulb.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 23 June 2022 Resolved
Every vsl equipped with inflatable liferafts shall have posted approved placards containing instructions for launching and inflating inflatable liferafts; vsl did not have placard with instructions for launching inflatable liferaft. 46 CFR 97.39-1(a) (Old I)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2022
Resolved 24 June 2022
Resolution: Placard placed near LRs.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 23 June 2022 Resolved
An efficient means of communication shall be provided between the wheelhouse and the bow/forward lookout station; vsl did not have required means of communication. 46 CFR 113.30-5(g) (Old J)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2022
Resolved 24 June 2022
Resolution: Vessel can communicate with bow and back deck.
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 23 June 2022 Resolved
Suitable covers shall be installed in way of all exposed places; deckplate in hallway to engine room had hole, presenting tripping hazard and no longer being a suitable cover. 46 CFR 92.25-15 (Old I)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2022
Resolved 24 June 2022
Resolution: Corrected to the satisfaction of MI.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 28 April 2021 Resolved
Each launching appliance must be approved under 46 CFR part 160, subpart 160.132 for use with the intended craft, with a winch approved under 46 CFR part 160, subpart 160.115 for use with the intended craft. Vessel's current davit does not have a approved placard.46 CFR 199.150
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2021
Resolved 23 June 2022
Resolution: New davit installed, tested.
09 - Working and Living Conditions › 092 - Working Conditions › Loading and unloading equipment
Issued 30 March 2021 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Resolved 28 April 2021
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 March 2021 Resolved
OVERHEAD LIGHT LOCATED IN THE PORT QUARTER ANCHOR LEVEL WIND PULLEY AREA IS FALLING OFF OF OVERHEAD. VSL MUST SECURE OVERHEAD LIGHTING TO THE OVERHEAD.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2021 Resolved
WIRING OVER THE PVHO ARE NOT SECURED TO THE OVERHEAD, OR SECURED USING PLASTIC ZIPTIES. VSL MUST SECURE WIRING OVER THE PVHO’S MUST BE SECURED EVERY 48” USING METAL BANDING.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 March 2021 Resolved
OPEN ENDED WIRE FOUND IN MAIN PASSAGEWAY WIRE RUN AFT OF MOUNTED FIRE AX. VSL MUST TERMINATE WIRE IN JUNCTION BOX.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2021
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 30 March 2021 Resolved
MULTIPLE LIGHT GUARDS BROKEN OR MISSING IN THE PUMP ROOM AND RUDDER ROOM. VSL MUST REINSTALL OR REPLACE LIGHT GUARDS FOR OVERHEAD LIGHTS.
Action required: 10 - Deficiency Rectified
Resolved 28 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 9 July 2020 Resolved
Each cargo vessel must carry a rescue boat boat approved under 160.156. Rescue boat motor not approved for Survitec rescue boat. 46 CFR 199.262
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2020
Resolution: Approved Motor installed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 July 2020 Resolved
At least 2 lifebuoys with attached smoke which must be stowed to be quickly released into the water without contacting the vessel. Arrangement not set up to be quickly released into the water. 46 CFR 199.70(a)(5)
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2020
Resolution: Bridge buoys installed in bracket.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 July 2020 Resolved
Suitable guards shall be installed in way of all exposed hazards. Exhaust lagging missing sections on all 3 generators.46 CFR 92.25-15(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 July 2020
Resolution: Lagging replaced.
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 9 July 2020 Resolved
Indication of rudder angle must be provided at the steering compartment. The RAI at the emergency steering station inoperable.46 CFR 58.25-25(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 August 2020
Resolved 13 July 2020
Resolution: Rai fixed
Documentation › Logs/Records › Operational Procedures for Engines or Equipment
Issued 2 May 2018 Resolved
Automation test procedures are not approved. Must submit to MSC for approval and have inpsector attend testing of procedures. 46 CFR 15.825 (d)
Action required: 705 - Other - as specified
Due 2 September 2018
Resolved 1 August 2019
Resolution: Conducted automation test procedures to the satisfaction of the attending marine inspector
Engineering › Pressure Vessel › Relief Valve
Issued 15 May 2017 Resolved
Safety relief valves on pressure vessels were not annually tested.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2017
Resolved 17 May 2017
Resolution: Safety relief valves were tested
Engineering › Compressed Air System (start air) › Valve
Issued 15 May 2017 Resolved
Engine control air systems need to be checked for operation of propulsion on navigation bridges.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2017
Resolved 17 May 2017
Resolution: Air system repaired and tested ship propulsion - all sat.
Communications › Alarms/Indicators › General Alarm
Issued 15 May 2017 Resolved
General alarm not audible on the outside decks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 17 May 2017
Resolution: Wasp nest cleared from alarm and tested to satisfaction.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 15 May 2017 Resolved
Insufficient lagging around generator exhausts
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 17 May 2017
Resolution: Lagging was placed around exhausts
Lifesaving › Inflatable Liferafts › Not on Board
Issued 15 May 2017 Resolved
Liferafts not on board
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2017
Resolved 17 May 2017
Resolution: Lifeboats placed on board and cradled properly.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 15 May 2017 Resolved
Paint locker not made of steel or wholly lined with steel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 19 June 2017
Resolution: Steel paint locker purchased - old paint locker removed.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 15 May 2017 Resolved
Panelboard is missing safety side panels.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2017
Resolved 17 May 2017
Resolution: Side panels placed on panelboard
Electrical › Lighting (service) › Outlet Box
Issued 15 May 2017 Resolved
Junction boxes need to be repacked for wiring installation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2017
Resolved 23 March 2018
Resolution: Junction boxes properly packed
Engineering › Shafting/Propeller Arrangements › Coupling
Issued 15 May 2017 Resolved
Packing glands for shafts need to be repaired/replaced.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 June 2017
Resolved 17 May 2017
Resolution: Packing glands tightened up
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 31 March 2016 Resolved
Licensed Mate only able to provide photocopy of MMC. Mariner previously went through CG inspection on 24MAR16 and was able to provide USCG with valid MMC/TWIC. CG inspector instructed mariner to locate valid MMC/TWIC and provide proof to local USCG Marine Safety office.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 1 April 2016
Resolution: Mariner located valid MMC/TWIC and delivered proof to MSFO Lafayette Marine Inspectors on behalf of the attending MI; all sat.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 31 March 2016 Resolved
Copy of Fire Control Plan located in E/R Passageway was heavily detoriated, water damaged and unreadable. Destroy old copy and replace with a new copy in same location.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 4 April 2016
Resolution: Vessel printed new copy of fire control plan and laminated to prevent deterioration in the future; all sat.
Electrical › Electric Generation Source (service) › Generator
Issued 31 March 2016 Resolved
#4 SSDG unable to test overspeed. Vsl requires solenoid to be replaced for system to function properly. Upon completion of repair, CG inspector shall witness #4 SSDG overspeed test.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 4 April 2016
Resolution: Vessel replaced solenoid on the #4 SSDG, tested overspeed; all sat.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 13 June 2014 Resolved
Pilot house distribution panel not grounded. Panel required to be properly grounded nlt 13 July 2014.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 June 2014
Resolved 24 July 2014
Resolution: Verified distribution panel was properly grounded. Cleared CG-835.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 13 June 2014 Resolved
Port MDE exhaust blanket oil soaked. Renew exhaust blanket prior to 13 July 2014.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2014
Resolved 24 July 2014
Resolution: Inspected renewed exhaust blanket. Cleared CG-835.
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 13 June 2014 Resolved
MDE and SSDG overspeeds did not properly trip during testing. Return engine overspeeds to operation prior to 13 July 2014.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2014
Resolved 24 July 2014
Resolution: Overspeeds for both MDE and generators tested sat. Cleared CG-835.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 13 June 2014 Resolved
Distribution panels improperly labeled, and contain energized switches on circuits labeled as spares. Update distribution panel legends and remove out-of-use circuits prior to 13 July 2014.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2014
Resolved 24 July 2014
Resolution: Verified spare circuits breakers with installed switches were not wired to circuits. Cleared CG-835.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 13 June 2014 Resolved
Battle lanterns were the nonrechargeable type. Replace with rechargeable type nlt 13 August 2014.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 August 2014
Resolved 24 July 2014
Resolution: Inspected rechargeable emergency light installations. Cleared CG-835.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 June 2014 Resolved
Aft Deck deck light was temporarily wired. Hard wire deck light nlt 13 July 2014.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 July 2014
Resolved 24 July 2014
Resolution: Inspected deck light wiring. Cleared CG-835.
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 June 2014 Resolved
Plastic wire ties were used as supports for wires throughout the engine room. Replace plastic wire ties with metallic supports nlt 13 July 2014.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 July 2014
Resolved 7 October 2014
Resolution: metal bands installed
Communications › Audible Communications › SPD (Other)
Issued 13 June 2014 Resolved
PVHO communication system tested unsat. Make PVHO comms system operational prior to use.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 July 2014
Resolved 24 July 2014
Resolution: Op test on PVHO communication system tested sat. Cleared CG-835.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 13 June 2014 Resolved
Front of electrical panels for the aux blower and air compressor were loose. Panels need to be reattached.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2014
Resolved 24 July 2014
Resolution: Verified panel fronts were firmly affixed. Cleared CG-835.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 13 June 2014 Resolved
Discovered excessive oil leaks on port MDE and generator. Required leak reduction.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 July 2014
Resolved 24 July 2014
Resolution: Inspected engines for excessive oil leaks; all sat. Cleared CG-835.
Lifesaving › Inflatable Liferafts › Capacity
Issued 13 June 2014 Resolved
Alter liferaft installation to ensure 150% on both sides of vsl during next drydocking.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 4 April 2016
Resolution: Vessel has made liferafts easily transferrable across single deck.
Engineering › Bilge Water Management System › Piping
Issued 13 June 2014 Resolved
Remove sluice valve and provide means for bilge water removal in Jet Pump Room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 August 2014
Resolved 7 October 2014
Resolution: pipe rerouted and valve removed
Lifesaving › Lifebuoys › Serviceable
Issued 13 June 2014 Resolved
One ring buoy had water intrusion. Replace damaged ring buoy
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2014
Resolved 13 June 2014
Resolution: Damaged ring buoy was replaced.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 18 June 2008 Resolved
33 U.S.C. 1321(j)(5)(G)-did not receive certification statement attesting to largest vsl worst case discharge
Due 18 July 2008
Resolved 12 January 2009
Resolution: Cert statement received 12/15/2008. Vessel IOA expiration date 9/20/2009
Documentation › Certificates/Documents › Coastwise Load Line Certificate
Issued 30 July 2007 Resolved
Coastwise Load Line Certificate - Missing
Action required: 705 - Other - as specified
Resolved 5 August 2009
Resolution: vsl has an international load line and is not required to have a coastwise loadline. Reference CG-5212 load line policy notes dated 22 Sep 08.
Construction/Loadline › Markings › Load Line Mark
Issued 30 July 2007 Resolved
Confirm load line position once load line certificate is assigned.
Action required: 705 - Other - as specified
Resolved 23 May 2008
Resolution: Confirmed location of load line.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 30 July 2007 Resolved
One Ablebodied Seaman not avaiable at time of inspection.
Action required: 705 - Other - as specified
Resolved 30 May 2008
Engineering
Issued 19 October 2001 Resolved
Port main shaft tach indicates turns in the same direction when turning ahead and astern. Replace gauge and test in the presence of the attending Marine Inspector.
Condition: Unknown
Due 19 November 2001
Resolved 21 November 2001
Construction/Loadline
Issued 18 April 2001 Resolved
PRIOR TO OPERATING VESSEL MAKE PERMANENT REPAIRS TO STBD SIDE BULWARKS, GUNWHALE, STERN WRAP, FOREMAST AND AFT MAIN DECK TO THE SATISFACTION OF THEATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 21 April 2001
Resolved 24 April 2001
Lifesaving
Issued 14 May 1999 Resolved
PROVIDE UPDATED AND CORRECTED COPY OF VESSEL FIRE AND SAFETY PLAN, PROVIDE MARKED UP COPY WITH CORRECTED COPY TO MSO NEW ORLEANS - NEW CONSTRUCTION FOR VERIFICATION.
Condition: Unknown
Due 10 November 1999
Resolved 10 November 1999
Unknown
Issued 17 May 1997 Resolved
Test air receiver (2) P.V. valves.
Condition: Unknown
Due 17 May 1997
Resolved 17 May 1997
Deck/Cargo
Issued 17 May 1997 Resolved
Repair/renew and test cargo tank P.V. Valves (4).
Condition: Unknown
Due 17 May 1997
Resolved 17 May 1997
Navigation
Issued 17 May 1997 Resolved
Repair all around light on forward mast._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 May 1997
Resolved 17 May 1997
Unknown
Issued 17 May 1997 Resolved
Clean engine room vent ducts.
Condition: Unknown
Due 17 May 1997
Resolved 17 May 1997
Lifesaving
Issued 17 May 1997 Resolved
Install working gauge on starboard air receiver.
Condition: Unknown
Due 17 May 1997
Resolved 17 May 1997
Fire Fighting
Issued 7 August 1987 Resolved
WHEN A PERMANENT CREW IS ON BOARD AND PRIOR TO PLACING VESSEL IN SERVICE, HOLD AND LOG A FIRE AND MAN-OVERBOARD DRILL. FURNISH A COPY OF VESSEL'S LOG AND A STATEMENT THAT DRILLS WERE COMPLETED TO MIDET MORGAN CITY.
Condition: Unknown
Due 7 August 1987
Resolved 7 August 1987
Unknown
Issued 24 May 1985 Resolved
REMOVE PIT COCHS FROM MAIN ENGINE'S OIT FILTER, PROVIDE PROTECTIVE COVERS. ITEMS #1-6 ARE TO BE COMPLETED PRIOR TO 30MAY85 TO THE SATISFACTION OF THE COGNIZANT OFFICER N CHARGE MARINE INSPECTION.
Condition: Unknown
Due 24 May 1985
Resolved 24 May 1985
Unknown
Issued 24 May 1985 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL JOHATHAN DN636322
Condition: Unknown
Due 24 May 1985
Resolved 24 May 1985
Unknown
Issued 24 May 1985 Resolved
REPLACE BROKEN LATCH ON STBD GENERATOR.
Condition: Unknown
Due 24 May 1985
Resolved 24 May 1985
Unknown
Issued 24 May 1985 Resolved
PROVIDE FLAME SCREENS FOR VENTS AS NEEDED.
Condition: Unknown
Due 24 May 1985
Resolved 24 May 1985
Unknown
Issued 24 May 1985 Resolved
PROVIDE SLIDE BAR SWITCH FOR ELECTRICAL PANEL.
Condition: Unknown
Due 24 May 1985
Resolved 24 May 1985
Unknown
Issued 24 May 1985 Resolved
REPLACE LIGHT BULBS FOR RESCUE BOAT AND STBD LIFE RAFT, EMERGENCY LIGHTS.
Condition: Unknown
Due 24 May 1985
Resolved 24 May 1985
Unknown
Issued 24 May 1985 Resolved
RE-WORK ENGINE ROOM EMERGENCY ESCAPE HATCHES SO THEY SECURE CORRECTLY.
Condition: Unknown
Due 24 May 1985
Resolved 24 May 1985

Casualty record · 3

18 April 2001Routine · role: Involved in a Marine Casualty · activity 58947
2 December 2001Routine · role: Involved in a Marine Casualty · activity 84364
13 August 2013Routine · role: Acknowledged Pollution Source · activity 4683575
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

BLACK GOLD (2001). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.