Records from 1981 to 2012. Most recent: inspection, 12 December 2012.
Inspection history · 76
12 December 2012
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4501028
12 July 2011
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4079137
30 November 2010
Examination of Repairs
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3901003
10 May 2010
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3736899
4 May 2010
Annual Inspection · MTSA Verification
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3733286
20 February 2009
MTSA Verification · Periodic Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3421056
8 October 2008
Examination of Repairs · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3340662
26 September 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3336207
12 August 2008
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3292872
14 March 2008
Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3163004
7 November 2006
Examination of Repairs · Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2816011
2 August 2005
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2464768
30 November 2004
Periodic Inspection · MTSA Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2250189
14 October 2004
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2220939
24 November 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1954103
22 October 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1933904
5 November 2002
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1701222
3 October 2001
COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1443247
13 June 2001
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1066181
11 June 2001
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1425141
31 October 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 493118
7 June 2000
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 819449
1 September 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 452467
11 June 1999
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 809472
5 April 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 454247
12 February 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1128318
8 February 1999
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 792642
9 April 1998
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1414974
2 April 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 788640
27 March 1998
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1433327
16 January 1998
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1406241
2 June 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1455484
15 August 1996
Re-Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1089184
30 May 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1086244
1 June 1995
COI Inspection · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1435643
21 September 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 870938
13 June 1994
Re-Inspection · Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1135013
28 May 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 63554
28 May 1994
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 177850
9 April 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 479553
4 June 1993
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1148376
25 May 1993
Permit to Proceed
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1142859
19 May 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 684925
13 May 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 505333
18 June 1992
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1261819
7 May 1992
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1259395
18 February 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1259129
17 February 1992
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1257808
29 January 1992
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 958535
13 November 1991
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 491398
5 September 1991
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 941574
19 June 1991
Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 998294
13 August 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 520615
6 February 1990
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 905646
6 April 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 471765
8 March 1989
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1203403
26 September 1988
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1196115
5 February 1988
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1018260
4 February 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 321203
28 January 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 495639
23 January 1988
Hull Examination · Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1018215
15 January 1988
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1324572
8 January 1988
COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1318648
4 January 1988
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1011007
7 July 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 517376
23 February 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 539153
13 January 1987
Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1006454
24 September 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 475425
2 July 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 507480
18 March 1986
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 456303
24 February 1986
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 460936
9 January 1986
COI Inspection · Credit Drydock
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 997651
7 December 1984
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1282517
17 February 1984
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1278940
22 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271775
22 September 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967939
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 4 May 2010
Resolved
Install cap to breaker box on aft wall of heater room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2010
Resolved 4 May 2010
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 4 May 2010
Resolved
Replace both mufflers on prime mover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2010
Resolved 10 May 2010
Resolution: Both mufflers have been replaced.
Stability › Watertight Integrity › General
Issued 4 May 2010
Resolved
Upon arrival at Texas City after a loaded transit, provide status of #1 and #3 voids with regards to the amount of water in voids.
Action required: 705 - Other - as specified
Due 11 May 2010
Resolved 10 May 2010
Resolution: Barge manager, Ricky Pace, called to report there was no additional water in voids. Barge left Corpus Christi w/ approximately 3 inches of water in voids (after water was pumped out by shipyard) which is same amount reported in Texas City.
Deck/Cargo
Issued 11 June 2001
Resolved
PROVE PROPER OF THE THERMAL FLUID HEATER PRIOR TO USE.
Condition: Unknown
Due 11 June 2001
Resolved 11 June 2001
Construction/Loadline
Issued 8 February 1999
Resolved
PRIOR TO LOADING CARGO,VESSEL TO PROCEED TO SHIPYARD FOR PERMANENT REPAIRS TO STBD SIDE COLLISION DAMAGE. VESSEL INTERNALS TO BE MADE READY FOR INTERNAL EXAM BY ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999
Deck/Cargo
Issued 16 January 1998
Resolved
Prior to conducting cargo transfer operations remove, repair as required and satisfactorily hydrostatically test all cargo transfer piping on discharge side of transfer pump to the satisfaction of the attending marineinspector.
Condition: Unknown
Due 16 January 1998
Resolved 16 January 1998
Engineering
Issued 25 May 1993
Resolved
PROVIDE BULBS FOR THERMAL HEATER ALARM INDICATOR LIGHTS.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Construction/Loadline
Issued 25 May 1993
Resolved
MAKE PERMANENT REPAIRS TO 8" CRACK IN STBD SFT CORNER IN WAY OF DECK KNUCKLE.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Engineering
Issued 25 May 1993
Resolved
PROVIDE GUARD ON BLOWER FAN TO MOTOR PULLEY/BELT.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Electrical
Issued 25 May 1993
Resolved
PROVIDE MISSING GLOBE AND REFASTEN FIXTURE COVER PLATE ASSY ON FIXTURE OVERFLUID HEATER CONTROL/ALARM PANEL.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Documentation
Issued 25 May 1993
Resolved
AMEND THERMAL FLUID HEATER TEST PROCEDURE TO PROVIDE SAFER METHOD TO TEST LOW BLOWER AIR PRESSURE AND LOW FLUID LEVER ALARM.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Electrical
Issued 25 May 1993
Resolved
REMOVE JURY-RIGGED PIG TAIL PLUGIN FROM ELECTRICAL BOX BY ENTRANCE TO FLUIDHEATER-GENERATOR SPACE.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Electrical
Issued 25 May 1993
Resolved
RESECURE LOOSE COVER ON ELECTRICAL PLUG IN BOX ON STBD BOW.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Electrical
Issued 25 May 1993
Resolved
PROVIDE CIRCUIT IDENTIFICATION FOR LEFT PANEL BOX IN FLUID HEATER-GENERATORSPACE.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Construction/Loadline
Issued 25 May 1993
Resolved
CLEAN AND GAS FREE BOW RAKE AND CARGO TANK #1. MAKE PERMANENT REPAIRS TO LEAK FROM CARGO TANK INTO RAKE.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Engineering
Issued 25 May 1993
Resolved
DEMONSTRATE OPERATION OF EXCESS FLUID TEMPERATURE & LOW FLUID LEVEL ALARMS,& RELIEF VALVE.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Deck/Cargo
Issued 25 May 1993
Resolved
DEMONSTRATE OPERATION OF CARGO PUMP EMERGENCY REMOTE SHUTDOWN.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Deck/Cargo
Issued 25 May 1993
Resolved
OPEN-UP CARGO TANK PV VALVES FOR INSPECTION.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Construction/Loadline
Issued 25 May 1993
Resolved
MAKE PERMANENT REPAIRS TO 3" CRACK IN DECK OF #1 STBD WING VOID 8' FWD OF CLEAT.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Engineering
Issued 25 May 1993
Resolved
OPEN-UP THERMAL FLUID HEATER FOR FIRESIDE EXAMINATION.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Electrical
Issued 25 May 1993
Resolved
DEMONSTRATE GENERATOR REMOTE SHUTDOWN.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Engineering
Issued 25 May 1993
Resolved
PROVIDE HEAT SHIELDS ON RACOR FUEL FILTERS.
Condition: Unknown
Due 25 May 1993
Resolved 25 May 1993
Construction/Loadline
Issued 17 February 1992
Resolved
MAKE PERMANENT REPAIRS TO THE 9" HORIZONAL FRACTURE IN THE BOW RAKE VOID, PORT SIDE, APPROX 10' FROM BOW, APPROX 3' FROM DECK.
Condition: Unknown
Due 17 February 1992
Resolved 17 February 1992
Deck/Cargo
Issued 6 February 1990
Resolved
MAKE REPAIRS TO AND PROVE PROPER OPERATION OF, THERMAL FLUID HEATER PRIOR TO LOADING CARGOES REQUIRING ELEVATED TEMPERATURES.
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Unknown
Issued 23 January 1988
Resolved
PROVIDE EVIDENICE OF A NEW CERTIFICATE OF FINANCIAL RESPONSIBILITY (WATER POLLUTION) IN THE NAME OF THE NEW OPERATOR TO THE SATISFACTION OF THE COGNIZANT [name withheld] CARGO BUT IN NO CASE LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 23 January 1988
Resolved 23 January 1988
Unknown
Issued 23 January 1988
Resolved
OBTAIN AND PLACE ON BOARD OIL TRANSFER PROCEDURES PRIOR TO TRANSFER OF CARGO BUT IN NO CASE LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 23 January 1988
Resolved 23 January 1988
Unknown
Issued 23 January 1988
Resolved
OBTAIN AND PLACE ON BOARD AN APPROVED THERMAL FLUID HEATER INSTRUCTION BOOKLET. MUST BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT [name withheld] OF THE THERMAL FLUID HEATER BUT IN NO CASE LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 23 January 1988
Resolved 23 January 1988
Construction/Loadline
Issued 8 January 1988
Resolved
RENEW CARGO WARNING SIGN TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 8 January 1988
Resolved 8 January 1988
Construction/Loadline
Issued 8 January 1988
Resolved
STRIP ALL WATER OUT OF #3(P/S) WING VOIDS AND PROVE WATERTIGHT TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 8 January 1988
Resolved 8 January 1988
Deck/Cargo
Issued 8 January 1988
Resolved
UPON DISCHARGE OF CARGO MAKE THERMAL FLUID HEATER AVAILABLE FOR COMPLETE INSPECTION BY THE COGNIZANT OCMI.
Condition: Unknown
Due 8 January 1988
Resolved 8 January 1988
Construction/Loadline
Issued 8 January 1988
Resolved
LABEL TANK DOME WITH DANGER DEEP OUT SIGNS TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 8 January 1988
Resolved 8 January 1988
Construction/Loadline
Issued 8 January 1988
Resolved
REMOVE ALL DEBRIS FROM DECK AREA AROUND HEATER HOUSE AND CARGO PUMP ENGINE.REMOVE ALL OILY RESIDUE FROM DECK TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 8 January 1988
Resolved 8 January 1988
Construction/Loadline
Issued 4 January 1988
Resolved
MAKE AND MAINTAIN TEMPORARY REPAIRS IN WAY OF THE #2 CARGO TANK TOP AT THE CENTERLINE. PRIOR TO RELOADING ANY CARGO MAKE PERMANENT REPAIRS TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 4 January 1988
Resolved 4 January 1988
Construction/Loadline
Issued 4 January 1988
Resolved
MAKE AND MAINTAIN TEMPORARY REPAIRS IN WAY OF TWO FRACTURES APPROXIMATELY 6 FEET INBOARD FROM THE CABLE GUIDES PORTSIDE ON THE STERN. PRIOR TO RELOADING ANY CARGO PERMANENT REPAIRS TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 4 January 1988
Resolved 4 January 1988