MAURY USCG vessel records Sign in
← All vessels

HUNTER

HUNTER is a 1981 mobile offshore drilling unit. The Coast Guard has recorded 40 inspections since 1981, most recently in February 2000, along with 118 deficiencies.

Records from 1981 to 2000. Most recent: inspection, 4 February 2000.

Built
1981
Last inspected
4 February 2000
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAN8914
Flag
UNITED STATES
—
Maury page id
psix-53278

Inspections, by type

…with no type recorded18
Years with a record 15 calendar years (1981–2000)
The 40 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it3643 - Regulatory (Subpart C or D), Net Ton
8838 - Dead Weight, Ton
5829 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WAN8914MMSI not assigned · expired · compulsorily equipped · granted 23 June 1995, cancelled 7 January 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 40

4 February 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 11489
3 March 1996 Administrative
Administrative · Activities Far East · USCG Oceania District (CGD-O) · Activity 1078965
21 March 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · Activities Far East · USCG Oceania District (CGD-O) · Activity 1136706
24 October 1994 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 863438
7 July 1994 Hull Examination · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1354799
28 April 1994 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1420863
19 March 1994 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1466870
25 March 1993 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 838846
21 March 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 139643
10 July 1992 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 946650
4 May 1992 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1255281
20 February 1992 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1259605
19 August 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1309911
2 June 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1216073
1 March 1991 COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 902977
18 October 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 908689
30 April 1990 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 923668
31 January 1990 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1244685
18 May 1989 Deficiency Check · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1038894
27 February 1989 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1343459
28 October 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1350535
10 June 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 894068
14 April 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1032543
10 February 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1331100
13 January 1988 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1319236
25 November 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1030084
19 November 1986 Re-Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314576
8 May 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986902
27 February 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995322
31 January 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1305431
24 January 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294694
20 May 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 981310
19 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287922
15 February 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286524
10 January 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285996
31 August 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282203
29 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973943
14 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973939
7 January 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281707
27 December 1981 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1279356

Deficiency record · 118

Lifesaving
Issued 7 July 1994 Resolved
END FOR END THE NO.1,2,&3 LIFEBOAT DAVIT FALLS & NO.1-2 & NO.3-4 LIFERAFT DAVIT LAUNCH FALLS. WEIGHT TEST ALL FALLS PRIOR TO PLACING LIFEBOATS & LIFERAFTS BACK TO SERVICE. DOCUMENT THE RESULTS OF TEST IN THE VESSEL'S OFFICIAL LOGBOOK & SEND COPY WITH LETTER SIGNED BY OIM/BS TO [name withheld].
Condition: Unknown
Due 7 July 1994
Resolved 7 July 1994
Fire Fighting
Issued 19 March 1994 Resolved
PROVIDE [name withheld] WITH THE FOAM ANALYSIS REPORT OF THE SAMPLE TAKEN FROM THE VESSEL IN MARCH 1994.
Condition: Unknown
Due 19 March 1994
Resolved 19 March 1994
Fire Fighting
Issued 19 March 1994 Resolved
PROVIDE DOCUMENTATION THAT LEAKING VALVE TOP ON PAINT LOCKER HALON BOTTLE (167 lbs) HAS BEEN SERVICED AND IS BACK IN SERVICE. UNTIL COMPLIANCE HAS BEEN MADE, PROVIDE AN EQUAL AMOUNT OF FIRE PROTECTION AS A SUBSTITUTE.
Condition: Unknown
Due 19 March 1994
Resolved 19 March 1994
Construction/Loadline
Issued 19 March 1994 Resolved
AT THE NEXT RIG MOVE BUT NO LATER THAN 30 SEPTEMBER 1994, CONDUCT THE SPECIAL EXAMINATION IN LIEU OF DRYDOCKING.
Condition: Unknown
Due 19 March 1994
Resolved 19 March 1994
Engineering
Issued 19 March 1994 Resolved
AT THE NEXT RIG MOVE BUT NO LATER THAN 30 SEPTEMBER 1994, EXAMINE OR HYDRO ALL AIR RECEIVERS, BULK TANKS, AND TENSIONERS TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 19 March 1994
Resolved 19 March 1994
Documentation
Issued 1 March 1991 Resolved
PROVIDE TO THE OCMI IN HONOLULU A COPY OF THE APPROVED LIFESAVING EQUIPMENTPLAN REVISED TO INDICATE THE ADDITIONAL LIFEBOAT.
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Documentation
Issued 1 March 1991 Resolved
PROVIDE TO THE OCMI IN HONOLULU A COPY OF THE APPROVED GENERAL ARRANGEMENT PLAN REVISED TO INDICATE THE CURRENT MODIFICATIONS.
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Documentation
Issued 1 March 1991 Resolved
PROVIDE TO THE OCMI IN HONOLULU A COPY OF THE PLANS FOR THE NEW TOP DRIVE STAMPED BY A REGISTERED PROFESSIONAL ENGINEER.
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Documentation
Issued 1 March 1991 Resolved
PROVIDE TO THE OCMI IN HONOLULU A COPY OF THE REVISED OPERATIONS MANUAL WHICH ACCOMMODATES THE TOP DRIVE AND ACCOMMODATIONS MODIFICATIONS AND_x001C_ PROVIDES UPDATED STABILITY INFORMATION.
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Documentation
Issued 1 March 1991 Resolved
PROVIDE TO THE OCMI IN HONOLULU A COPY OF THE COAST GUARD APPROVED PLANS FOR THE NEWLY INSTALLED FIRE DETECTION SYSTEM.
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Fire Fighting
Issued 1 March 1991 Resolved
INSTALL TYPE APPROVED NOZZLES AND TURRENTS ON THE HELIDECK FOAM SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Documentation
Issued 1 March 1991 Resolved
PROVIDE TO THE OCMI IN HONOLULU A COPY OF THE APPROVED PLANS FOR THE_x001C_ HELIDECK FOAM SYSTEM.
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Documentation
Issued 1 March 1991 Resolved
PROVIDE TO THE OCMI IN HONOLULU A COPY OF THE APPROVED PLANS FOR THE ACCOMMODATIONS MODIFICATIONS.
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Unknown
Issued 1 March 1991 Resolved
PLACE ON BOARD ALCOHOL TEST KITS AND URINALYSIS TEST KITS AS REQUIRED.
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Electrical
Issued 1 March 1991 Resolved
INSTALL GENERAL ALARMS IN THE FIRE AND BALLAST PUMPROOM, THE SACK ROOM, ANDTHE STOREROOM FORWARD OF THE SACK ROOM.
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Fire Fighting
Issued 1 March 1991 Resolved
RENEW HOSE RACKS AT BOTH HELIDECK FIRE STATIONS.
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Engineering
Issued 1 March 1991 Resolved
LABEL AND MAKE OPERABLE ALL ENGINE ROOM FUEL OIL REMOTE SHUTDOWN REACH RODS(4 TOTAL).
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Documentation
Issued 1 March 1991 Resolved
PROVIDE PROOF THAT APPLICATIONS OF REVISED LICENCES HAS BEEN SUBMITTED TO THE OCMI IN NEW ORLEANS FOR JAMES ALGOOD(BCO), DAN FREEMAN(BCO), AND JAMES F. JORDON (OIM).
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Electrical
Issued 1 March 1991 Resolved
INSTALL EMERGENCY LIGHTS IN THE SACK ROOM AND THE STOREROOM FORWARD OF THE SACK ROOM.
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Fire Fighting
Issued 1 March 1991 Resolved
REPAIR/REMOVE/MODIFY THE EMERGENCY FIRE PUMP SO THAT IT WILL DEVELOPE 50 PSI OF PRESSURE ON THE TWO FARTHEST HOSES (HELIDECK) AS REQUIRED. ALL PIPING REPAIRS MUST BE PROVED BY A HYDORSTATIC TEST AT 200 PSI.
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Documentation
Issued 1 March 1991 Resolved
PROVIDE AN UPDATED SAFETY PLAN TO THE OCMI IN HONOLULU FOR REVIEW AND APPROVAL.
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Documentation
Issued 1 March 1991 Resolved
PROVIDE TO THE OCMI IN HONOLULU THE UPDATED WATCH, QUARTER AND STATION BILLWHICH ACCOMMODATES THE NEW MANNING OF THE VESSEL, I.E. BOTH THE CURRENT INCREASE AND THE NEW MANNING REQUIREMENTS.
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Documentation
Issued 1 March 1991 Resolved
PROVIDE A COPY OF THE VIDEO AND WRITTEN REPORT FOR THE UNDERWATER SURVEY TOTHE OCMI IN HONOLULU.
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Lifesaving
Issued 1 March 1991 Resolved
PROPERLY INSTALL THE DAVIT LAUNCHED LIFERAFTS FOR FLOAT FREE OPERATION.
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Fire Fighting
Issued 1 March 1991 Resolved
RENEW ABOVE DECK PIPING AT FIRE STATION 14, AND ELBOWS AT FIRE STATIONS 25 AND 26.
Condition: Unknown
Due 1 March 1991
Resolved 1 March 1991
Lifesaving
Issued 27 February 1989 Resolved
PROVIDE 12 HAND HELD RED DISTRESS FLARES FOR EACH LIFE CAPSULE; PRESENTLY STOWED FLARES ARE EXPIRED. REF: 46CFR94.20-15(GG)
Condition: Unknown
Due 27 February 1989
Resolved 27 February 1989
Deck/Cargo
Issued 27 February 1989 Resolved
PROVIDE EVIDENCE OF ANNUAL CRANE INSPECTIONS IN ACCORDANCE WITH 46CFR109.437, 109.521, AND 107.259.
Condition: Unknown
Due 27 February 1989
Resolved 27 February 1989
Electrical
Issued 27 February 1989 Resolved
REPAIR HELO-PORT PERIMETER LIGHTING IN ACCORDANCE WITH API RECOMMENDED PRACTICE FOR OFFSHORE HELIPORT FACILITIES.
Condition: Unknown
Due 27 February 1989
Resolved 27 February 1989
Engineering
Issued 14 April 1988 Resolved
PROVIDE RELIEF VALVE THAT DOES NOT EXCEED THE MAXIMUM ALLOWABLE WORKING PRESSURE OF THE DRILL FLOOR AIR RECIEVER. (46 CFR 61.10-5)
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Unknown
Issued 13 January 1988 Resolved
RECONNECT AND TEST THE REMOTE OPERATORS FOR THE FUEL OIL CUTOUT VALVES LOCATED IN THE PORT/STARBOARD CAISSONS.
Condition: Unknown
Due 13 January 1988
Resolved 13 January 1988
Documentation
Issued 13 January 1988 Resolved
PROVIDE DOCUMENTATION PROVING THAT THE AJAX PACKAGE BOILERS AND THE HELO FUELING STATION WILL BE MADE INOPERABLE AND WILL NOT BE USED UNTIL ALL TESTS AND INSPECTIONS ARE CONDUCTED.
Condition: Unknown
Due 13 January 1988
Resolved 13 January 1988
Unknown
Issued 13 January 1988 Resolved
TEST THE RELIEF VALVE FOR THE DRILL FLOOR AIR RECEIVER AND MAKE AVAILABLE FOR INTERNAL INSPECTION BY A U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 13 January 1988
Resolved 13 January 1988
Electrical
Issued 13 January 1988 Resolved
MAKE THE LOW LUBE OIL SHUTDOWNS ON THE RIG'S SERVICE GENERATOR PRIME MOVERSOPERABLE.
Condition: Unknown
Due 13 January 1988
Resolved 13 January 1988
Unknown
Issued 13 January 1988 Resolved
MAKE THE AIR RECEIVER LOCATED IN THE OVERHEAD INBOARD SIDE OF THE MACHINERYSPACE AVAILABLE FOR INTERNAL INSPECTION BY A U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 13 January 1988
Resolved 13 January 1988
Unknown
Issued 13 January 1988 Resolved
MAKE ALL BULK TANKS AVAILABLE FOR INTERNAL INSPECTION BY A U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 13 January 1988
Resolved 13 January 1988
Unknown
Issued 13 January 1988 Resolved
MAKE ALL MOTION COMPENSATING TENSIONER RECEIVERS AVAILABLE FOR INTERNAL INSPECTION BY A U. S. COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 13 January 1988
Resolved 13 January 1988
Electrical
Issued 13 January 1988 Resolved
MAKE THE AUDIBLE ALARM FOR LOSS OF PURGE AIR TO THE DRILLER'S CONSOLE OPERABLE.
Condition: Unknown
Due 13 January 1988
Resolved 13 January 1988
Fire Fighting
Issued 19 November 1986 Resolved
MAKE OPERABLE THE FOLLOWING GENERAL ALARM BELLS: SACK ROOM AND ABOVE WATERTIGHT DOOR LEADING INTO SACK ROOM FROM MOON POOL.
Condition: Unknown
Due 19 November 1986
Resolved 19 November 1986
Documentation
Issued 19 November 1986 Resolved
PROVIDE ONBOARD A COAST GUARD APPROVED STABILITY LETTER DATED 03 MAY 1982.
Condition: Unknown
Due 19 November 1986
Resolved 19 November 1986
Deck/Cargo
Issued 19 November 1986 Resolved
RECONNECT CHAIN TO SHACKLE IN CHAIN LOCKER FOR #3, #6, AND #7.
Condition: Unknown
Due 19 November 1986
Resolved 19 November 1986
Fire Fighting
Issued 19 November 1986 Resolved
HYDRO TEST SCBA BOTTLES FOR BOTH FIREMAN'S OUTFIT.
Condition: Unknown
Due 19 November 1986
Resolved 19 November 1986
Electrical
Issued 19 November 1986 Resolved
RESECURE ELECTRICAL CABLE IN WAY OF PORT AND STBD BOW COLUMNS (EXTERIOR).
Condition: Unknown
Due 19 November 1986
Resolved 19 November 1986
Electrical
Issued 19 November 1986 Resolved
SECURE ELECTRICAL CABLE FOR DECK LIGHT IN WAY OF FUEL OIL TRANSFER PORT.
Condition: Unknown
Due 19 November 1986
Resolved 19 November 1986
Electrical
Issued 19 November 1986 Resolved
SECURE ALL LOOSE WIRES IN WAY OF DRILL FLOOR.
Condition: Unknown
Due 19 November 1986
Resolved 19 November 1986
Navigation
Issued 19 November 1986 Resolved
MAKE HORN OPERABLE FOR TELEPHONE IN WAY OF STBD PUMP ROOM.
Condition: Unknown
Due 19 November 1986
Resolved 19 November 1986
Electrical
Issued 19 November 1986 Resolved
SECURE ELECTRICAL CABLE FOR FLOAT LEVEL'S IN WAY OF MUD TANKS.
Condition: Unknown
Due 19 November 1986
Resolved 19 November 1986
Accommodation/Occupational Safety
Issued 19 November 1986 Resolved
SECURE GALLEY EXHAUST VENT MOTOR CABLE TOPSIDE STBD.
Condition: Unknown
Due 19 November 1986
Resolved 19 November 1986
Electrical
Issued 19 November 1986 Resolved
SECURE ELECTRICAL CABLES TO REMOTE MUD PIT CONTROLLER AND ADJACENT PHONE LINES IN MUD PIT ROOM.
Condition: Unknown
Due 19 November 1986
Resolved 19 November 1986
Electrical
Issued 19 November 1986 Resolved
LABLE CIRCUITS ON BOTH EXPLOSION PROOF JUNCTION BOXES LOCATED AFT OF DRILL FLOOR.
Condition: Unknown
Due 19 November 1986
Resolved 19 November 1986
Electrical
Issued 19 November 1986 Resolved
SECURE ELECTRICAL CABLE IN WAY OF HELO FUELING STATION.
Condition: Unknown
Due 19 November 1986
Resolved 19 November 1986
Documentation
Issued 24 January 1986 Resolved
PROVIDE APPROVAL LETTER FOR THE FIRE CONTROL PLAN AND THE HAZARDOUS LOCATION PLAN.
Condition: Unknown
Due 24 January 1986
Resolved 24 January 1986
Lifesaving
Issued 24 January 1986 Resolved
CONDUCT WEIGHT TEST OF #2 LIFEBOAT. COMPLIANCE DATE IS 31JAN86.
Condition: Unknown
Due 24 January 1986
Resolved 24 January 1986
Electrical
Issued 24 January 1986 Resolved
PROPERLY LABEL AND PROVE SATISFACTORY OPERATION OF EMERGENCY VENTILATION SHUTDOWN ON DRILL FLOOR, ALSO INSTALL HAMMER TO BREAK GLASS.
Condition: Unknown
Due 24 January 1986
Resolved 24 January 1986
Navigation
Issued 24 January 1986 Resolved
PAINT NAVIGATIONAL SIDE LIGHT SCREENS MATT BLACK IN COLOR PER ANNEX 1 COLREGS.
Condition: Unknown
Due 24 January 1986
Resolved 24 January 1986
Electrical
Issued 24 January 1986 Resolved
REPLACE CONTACT MAKER OR PROVIDE DOCUMENTATION THAT IT IS APPROVED FOR HAZARDOUS LOCATIONS LOCATED ON THE DRILL FLOOR.
Condition: Unknown
Due 24 January 1986
Resolved 24 January 1986
Accommodation/Occupational Safety
Issued 24 January 1986 Resolved
INSTALL MISSING SINK IN HEADS ON LOWER LEVEL, ACCUMMOCLATION SPACE.
Condition: Unknown
Due 24 January 1986
Resolved 24 January 1986
Deck/Cargo
Issued 24 January 1986 Resolved
SERVICE OR REPLACE PERSONNEL BASKET ("BILLY PUGH") CURRENTLY IN SERVICE.
Condition: Unknown
Due 24 January 1986
Resolved 24 January 1986
Deck/Cargo
Issued 24 January 1986 Resolved
PROVIDE INTERNAL INSPECTION #1-8 BULK TANKS AND PROVE SATISFACTORY OPERATION OF RELIEF VALVE.
Condition: Unknown
Due 24 January 1986
Resolved 24 January 1986
Deck/Cargo
Issued 24 January 1986 Resolved
PROVIDE FOR INTERNAL INSPECTION DRILL FLOOR AIR RECEIVER AND PROVE SATISFACTORY OPERATION OF RELIEF VALVE.
Condition: Unknown
Due 24 January 1986
Resolved 24 January 1986
Deck/Cargo
Issued 24 January 1986 Resolved
PROVIDE FOR INTERNAL INSPECTION TWENTY-THREE TENSIONER BOTTLES.
Condition: Unknown
Due 24 January 1986
Resolved 24 January 1986
Lifesaving
Issued 24 January 1986 Resolved
PROVE SATISFACTORY OPERATION OF THE BRAKE FOR THE DAVIT LAUNCH LIFE RAFT MOUNTED ON THE BOW WEIGHT TEST FALLS. COMPLIANCE DATE IS 31JAN86.
Condition: Unknown
Due 24 January 1986
Resolved 24 January 1986
Electrical
Issued 24 January 1986 Resolved
MAKE OPERATIONAL THE FOLLOWING GENERAL ALARM BELLS; INSIDE-OUTSIDE SACK ROOM, EMERGENCY GENERATOR ROOM, SHALE SHAKER AREA AND OUTSIDE SCR ROOM. COMPLIANCE DATE IS 07FEB86.
Condition: Unknown
Due 24 January 1986
Resolved 24 January 1986
Lifesaving
Issued 24 January 1986 Resolved
WEIGHT TEST THE QUICK RELEASE HOOKS FOR BOTH DAVIT LAUNCH LIFE RAFTS. COMPLIANCE DATE IS 31JAN86.
Condition: Unknown
Due 24 January 1986
Resolved 24 January 1986
Fire Fighting
Issued 24 January 1986 Resolved
PROVE SATISFACTORY OPERATION OF THE PURGE AIR ALARM ON THE DRILLERS CONSOLE
Condition: Unknown
Due 24 January 1986
Resolved 24 January 1986
Lifesaving
Issued 24 January 1986 Resolved
PROVIDE APPROVAL LETTER OR SUBMIT FOR APPROVAL THE USE OF JACOBS LADDER OF LIFEBOAT AND LIFERAFT STATIONS.
Condition: Unknown
Due 24 January 1986
Resolved 24 January 1986
Navigation
Issued 10 January 1985 Resolved
REPAIR THE STEERING GEAR SO THAT BOTH PUMPS CAN BE USED IN ALL LOCAL AND REMOTE CONTROL MODES.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Unknown
Issued 10 January 1985 Resolved
REMOVE THE BATTERIES LOCATED IN THE STOREROOM ADJACENT TO STAIRWAY LEADING TO THE PORT PUMP ROOM AND PLACE THEM IN THE BATTERY STORAGE ROOM ON DECK. 46 CFR 111.15.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Unknown
Issued 10 January 1985 Resolved
PROVIDE A MEANS OF SECURING THE DIESEL AIR COMPRESSOR FUEL SUPPLY FROM THE DAY TANK FROM OUTSIDE THE SPACE OR REMOVE. 46 CFR 650-60.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Lifesaving
Issued 10 January 1985 Resolved
MAKE OPERATIONAL THE LIMIT SWITCH TO THE NUMBER ONE LIFEBOAT. 46 CFR 111.95-7.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Electrical
Issued 10 January 1985 Resolved
PROVIDE THE REQUIRED EMERGENCY LIGHTS FOR THE RAFT STATION NUMBERS THREE AND FOUR AS SPECIFIED IN 46 CFR 111.75-16.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Electrical
Issued 10 January 1985 Resolved
WIRE THE HALON DISCONNECT SWITCH LOCATED IN THE EMERGENCY ROOM 46 CFR 111.54-1.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Fire Fighting
Issued 10 January 1985 Resolved
PROVIDE A DOOR HANDLE TO THE HALON STORAGE ROOM. ALSO REPLACE THE GASKET TO THIS DOOR AND PERMANENTLY PLUG THE BULKHEAD PENETRATION ADJACENT TO THISDOOR. 46 CFR 108.665.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Fire Fighting
Issued 10 January 1985 Resolved
PROVIDE A HALON SYSTEM WARNING SIGN FOR THE BOILER ROOM. 46 CFR 108.458.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Fire Fighting
Issued 10 January 1985 Resolved
PROVIDE A HALON ALARM WARNING SIGNS FOR ALL HALON PROTECTED SPACES. 46 CFR 108.458.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Fire Fighting
Issued 10 January 1985 Resolved
PROVIDE A HANDLE FOR THE FOAM STATION ON THE HELICOPTER DECK. 46 CFR 108.487.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Unknown
Issued 10 January 1985 Resolved
MOVE THE WINDSOCK AWAY FROM THE PERIPHERY OF THE HELICOPTER DECK. 46 CFR 108. 241.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Construction/Loadline
Issued 10 January 1985 Resolved
PRIOR TO THE COMPLETION OF THE NEXT RIG MOVE REPAINT THE VESSEL'S DRAFT MARKS. 46 CFR 108.661.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Engineering
Issued 10 January 1985 Resolved
HAVE THE RIG'S RUDDER ANGLE INDICATORS CORRECTED TO REFLECT THE PROPER RUDDER SWING. 46 CFR 111.40
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Fire Fighting
Issued 10 January 1985 Resolved
PROVIDE GENERAL ALARM WARNING SIGNS IN THE LIVING QUARTERS AND DRILL FLOOR AREAS. 46 CFR 108.625.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Electrical
Issued 10 January 1985 Resolved
LABEL ALL EMERGENCY LIGHTS ON THE RIG WITH A RED "E" 46 CFR 108.639.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Deck/Cargo
Issued 10 January 1985 Resolved
REMOVE FROM THE RIG THE CRACKED AND WORN FUEL HOSE FROM THE STARBOARD SIDE AND REPLACE IT MUST BE WITH AN APPROVED HOSE. 33 CFR 156.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Deck/Cargo
Issued 10 January 1985 Resolved
HYDROSTATICALLY TEST THE FUEL HOSE ON THE PORT SIDE IN ACCORDANCE WITH 33 CFR 156.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Electrical
Issued 10 January 1985 Resolved
MAKE OPERATIONAL THE GENERAL ALARM BELLS IN THE SACK ROOM AND THE MUD PUMP ROOM. 46 CFR 108.419.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Construction/Loadline
Issued 10 January 1985 Resolved
PROVIDE NEW GASKETS FOR THE WATERTIGHT DOORS/CADING TO THE PORT AND STARBOARD STEERING ROOM COMPARTMENTS. 46 CFR 108.113.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Electrical
Issued 10 January 1985 Resolved
REPAIR THE REMOTE VENTILATION SHUTDOWN. 46 CFR 61.20-3.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Electrical
Issued 10 January 1985 Resolved
REPAIR THE PURGE AIR SUPPLY TO THE DRILLERS CONSOLE. 46 CFR 111.92.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Electrical
Issued 10 January 1985 Resolved
MAKE THE EMERGENCY ENGINE SHUTDOWN ON THE DRILL FLOOR FOR A DIVISION I HAZARDOUS LOCATION WITH APPROVED EQUIPMENT.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Electrical
Issued 10 January 1985 Resolved
PROVIDE AN OIL SEPARATOR MOTOR CONTROL IN THE MUD PIT AREA THAT IS APPROVEDFOR HAZARDOUS LOCATIONS. 46 CFR 111.92.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Unknown
Issued 10 January 1985 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL, DIAMOND M. HUNTER DN642738.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Unknown
Issued 10 January 1985 Resolved
HAVE BOTH CRANES INSPECTED IN ACCORDANCE WITH API RP 2D 46 CFR 109.437.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Unknown
Issued 10 January 1985 Resolved
PROVIDE A CURRENT DOCUMENTATION STICKER FOR THE CERTIFICATE OF DOCU- MENTATION 46 CFR 107.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Lifesaving
Issued 10 January 1985 Resolved
REINSTALL THE NUMBER 3 DAVIT LAUNCHED LIFERAFT AND SEND TO THE [name withheld] OF THE ANNUAL SERVICING REPORT. 46 CFR 107.231 (B)
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Deck/Cargo
Issued 10 January 1985 Resolved
FIX THE EXPOSED WIRING TO THE SPEAKER IN THE PORT CRANE WHERE TEM- PORARILY SPLICED. 46 CFR 111.60.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Deck/Cargo
Issued 10 January 1985 Resolved
PROVIDE A 20" X 20" WIRE MESH FLAME SCREEN FOR THE PORT AFT CRANE FUEL VENT. 46 CFR 56.50-85.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Deck/Cargo
Issued 10 January 1985 Resolved
REPLACE THE SPLICED ARMORED CABLE IN THE PORT CRANE STORAGE ROOM. 46 CFR 111.60.
Condition: Unknown
Due 10 January 1985
Resolved 10 January 1985
Fire Fighting
Issued 7 January 1984 Resolved
REPLACE BROKEN HALON DIFFUSSER IN AUXILIARY MACHINERY SPACE.
Condition: Unknown
Due 7 March 1984
Resolved 7 January 1984
Lifesaving
Issued 7 January 1984 Resolved
PROVIDE AND INSTALL PROPER MANIFOLD FOR AIR BOTTLES IN BOTH LIFEBOATS.
Condition: Unknown
Due 7 February 1984
Resolved 7 January 1984
Deck/Cargo
Issued 7 January 1984 Resolved
SUBMIT FOR APPROVAL DETAILS OF NEW PAINT LOCKER ARRANGEMENT.
Condition: Unknown
Due 7 April 1984
Resolved 7 January 1984
Electrical
Issued 7 January 1984 Resolved
PROVIDE AS NECESSARY IN ALL HAZARDOUS AREAS, EQUIPMENT APPROVED FOR THE LOCATION INCLUDING CABLE SEALS AND REMOVAL OF NON APPROVED EQUIPMENT.
Condition: Unknown
Due 7 February 1984
Resolved 7 January 1984
Electrical
Issued 7 January 1984 Resolved
MARK ALL EMERGENCY LIGHTS AS NECESSARY.
Condition: Unknown
Due 7 March 1984
Resolved 7 January 1984
Electrical
Issued 7 January 1984 Resolved
INSTALL BLANKS IN ALL PANEL BOARDS AS NECESSARY.
Condition: Unknown
Due 7 March 1984
Resolved 7 January 1984
Lifesaving
Issued 7 January 1984 Resolved
WEIGHT TEST IN PRESENCE OF USCG INSPECTOR, BOTH LIFERAFT DAVITS INCLUDING RELEASING GEAR.
Condition: Unknown
Due 7 February 1984
Resolved 7 January 1984
Fire Fighting
Issued 7 January 1984 Resolved
PROVIDE AN APPROVED O2/ EXPLOSION METER FOR EACH FIREMAN'S OUTFIT.
Condition: Unknown
Due 7 January 1984
Resolved 7 January 1984
Deck/Cargo
Issued 7 January 1984 Resolved
MAKE TENSIONER VOLUME BOTTLES AVAILABLE FOR INSPECTION BY A USCG MARINE INSPECTIOR.
Condition: Unknown
Due 14 February 1984
Resolved 7 January 1984
Lifesaving
Issued 7 January 1984 Resolved
CONTINUE SERVICING OF DAVIT LAUNCHED LIFERAFTS.
Condition: Unknown
Due 7 February 1984
Resolved 7 January 1984
Lifesaving
Issued 7 January 1984 Resolved
PROVIDE CHART OF LIFESAVING SIGNALS FOR BOTH LIFEBOATS.
Condition: Unknown
Due 7 February 1984
Resolved 7 January 1984
Fire Fighting
Issued 7 January 1984 Resolved
PROVIDE FOAM SAMPLE ANALYSIS.
Condition: Unknown
Due 7 March 1984
Resolved 7 January 1984
Deck/Cargo
Issued 7 January 1984 Resolved
TEST MUD PUMP RELIEF VALVES IN PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 7 March 1984
Resolved 7 January 1984
Electrical
Issued 7 January 1984 Resolved
REPLACE LID ON SOLENOID BOX IN PORT PROPULSION SPACE AND MAKE WATERTIGHT.
Condition: Unknown
Due 7 March 1984
Resolved 7 January 1984
Electrical
Issued 7 January 1984 Resolved
MAKE PROPULSION JUNCITON BOX IN PROPULSION SPACES WATERTIGHT.
Condition: Unknown
Due 7 March 1984
Resolved 7 January 1984
Unknown
Issued 7 January 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU DIAMOND M HUNTER DN642738.
Condition: Unknown
Due 7 January 1984
Resolved 7 January 1984
Electrical
Issued 7 January 1984 Resolved
SUPPORT PROPULSION MOTOR CABLES OUT OF BILGES.
Condition: Unknown
Due 7 March 1984
Resolved 7 January 1984
Construction/Loadline
Issued 7 January 1984 Resolved
REPAIR REACH ROD IN PORT PROPULSION SPACE.
Condition: Unknown
Due 7 March 1984
Resolved 7 January 1984
Deck/Cargo
Issued 7 January 1984 Resolved
PROVIDE MOTION ALARM AND FIRE EXTINGUISHER FORKLIFT.
Condition: Unknown
Due 7 March 1984
Resolved 7 January 1984
Electrical
Issued 7 January 1984 Resolved
REPAIR ALARM LIGHT ON #1 GENERATOR ENGINE.
Condition: Unknown
Due 7 March 1984
Resolved 7 January 1984
Electrical
Issued 7 January 1984 Resolved
REMOVE ALUMINUM LUGS FROM ALL PANEL BOARDS AND REPLACE WITH COPPER LOGS.
Condition: Unknown
Due 7 March 1984
Resolved 7 January 1984
Engineering
Issued 7 January 1984 Resolved
PROVIDE PROTECTION FOR LUBE OIL SIGHT GLASS IN GENERATOR SPACE.
Condition: Unknown
Due 7 March 1984
Resolved 7 January 1984
Engineering
Issued 7 January 1984 Resolved
PROVIDE METAL FLAME GUARDS FOR ALL RACOR FUEL FILTERS.
Condition: Unknown
Due 7 March 1984
Resolved 7 January 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.