Records from 1981 to 2007. Most recent: inspection, 1 October 2007.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 26
1 October 2007
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3072287
9 November 2006
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2817693
6 June 2006
Deficiency Check · Periodic Inspection · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2672313
21 June 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2398034
13 June 2005
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2389279
4 June 2004
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2393776
4 March 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2018145
28 February 2003
Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1750758
22 June 1993
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 666055
11 June 1993
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 666056
7 June 1993
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 98873
19 May 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 828833
1 May 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379690
11 June 1991
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 912791
20 April 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 913816
27 December 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 911506
17 May 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 921794
1 May 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1219019
15 February 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1195496
23 January 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 895275
23 January 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 898735
3 December 1987
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1314220
9 December 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316008
22 October 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293987
30 September 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967353
4 September 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273983
Operations/Management › Casualty Reporting/Post-Casualty Actions › Notice of Marine Casualty
Issued 1 October 2007
No resolution recorded
The vessel owner failed to make OCMI notification upon discovering defects in the hull of the barge resulting in a loss of watertight integrity.
Action required: 705 - Other - as specified
Operations/Management › Casualty Reporting/Post-Casualty Actions › Filing Written Report of Marine Casualty
Issued 1 October 2007
No resolution recorded
A CG-2692 was not completed within five days after discovering a reportable casualty (loss of watertight integrity).
Action required: 705 - Other - as specified
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 October 2007
No resolution recorded
The vessel owner failed to schedule a reinspection and was found four months past due.
Action required: 705 - Other - as specified
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 October 2007
No resolution recorded
An annual inspection was not conducted within the required inspection window of opporunity for 2007 resulting in the vessel being operated out of compliance with the COI.
Action required: 705 - Other - as specified
Construction/Loadline › Hull › Bottom Plating
Issued 1 October 2007
No resolution recorded
Extensive repairs were made to the forward rake of the barge without prior notification to the OCMI.
Action required: 705 - Other - as specified
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 1 October 2007
No resolution recorded
The vessel was taken into dry dock without making OCMI notification.
Action required: 705 - Other - as specified
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 6 June 2006
Resolved
Both life ring buoys needed to have the name re-stenciled
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2006
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 6 June 2006
Resolved
Battery was dead
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2006
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 6 June 2006
Resolved
Missing one adult PFD
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 June 2006
Resolved
Starboard nav light screen was wasted and not displayed at the correct angle.
Action required: 705 - Other - as specified
Resolved 12 July 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 June 2006
Resolved
All deck rails were missing
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 July 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 June 2006
Resolved
The aft section of the house and forward section of the work shed had loose sheet metal posing a hazard to personnel.
Action required: 705 - Other - as specified
Resolved 12 July 2006
Deck/Cargo › Mooring/Anchoring › Capstan
Issued 6 June 2006
Resolved
A cleat on the starboard side was wasted. Barge personnel do not use this. Requested it be repaired or removed.
Action required: 705 - Other - as specified
Resolved 12 July 2006
Construction/Loadline › Hull › Hull Plating
Issued 6 June 2006
Resolved
Deck insert needed at the stern as marked
Action required: 705 - Other - as specified
Resolved 12 July 2006
Construction/Loadline › Hull › Bracket
Issued 6 June 2006
Resolved
Brakets/straps around the base of each tank were wasted.
Action required: 705 - Other - as specified
Resolved 12 July 2006
Construction/Loadline › Hull › Girder
Issued 6 June 2006
Resolved
Center support for the aft tank was completed wasted away at the bottom 1.5 to 2 feet.
Action required: 705 - Other - as specified
Resolved 12 July 2006
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 6 June 2006
Resolved
Draft marks needed to be painted
Action required: 705 - Other - as specified
Resolved 12 July 2006
Construction/Loadline › Structures › Trunk
Issued 6 June 2006
Resolved
Replace wasted areas around the spuds as marked
Action required: 705 - Other - as specified
Resolved 12 July 2006
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 6 June 2006
Resolved
Coaming at the bow and stern needed repairs as marked
Action required: 705 - Other - as specified
Resolved 12 July 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 June 2006
Resolved
Lagging on the piping from the heater was loose.
Action required: 705 - Other - as specified
Resolved 12 July 2006
Deck/Cargo › Cargo Heating › General
Issued 28 February 2003
Resolved
Thermal Fluid Heater panel that controls the various methods of automatic shutdown is not installed. Currently there is a means to shutdown the heater but all of the approved methods to shutdown the heater are not in place. LEGACY COMPONENT DESC: Variable shutdown controls
Action required: 705 - Other - as specified
Due 5 April 2003
Resolved 17 June 2005
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 28 February 2003
Resolved
Coast Guard approval letter for vessel response plan was not in place. LEGACY COMPONENT DESC: Emergency Instructions
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 June 2003
Resolved 6 January 2006
Documentation
Issued 1 May 1992
Resolved
VESSEL NOT TO OPERATE (ON/OFFLOAD CARGO) UNTIL SUCH TIME AS OIL TRANSFER PROCEDURES ARE ON BOARD.
Condition: Unknown
Due 1 June 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 1 May 1992
Resolved
PROVIDE AND INSTALL PROPER NAVIGATIONAL LIGHTS TO THE SATISFACTION OF THE ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 1 June 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 1 May 1992
Resolved
PROVIDE PLUGS FOR DECK CONTAINMENT TO THE SATISFACTION OF THE ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 1 June 1992
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 1 May 1990
Resolved
PROVIDE TESTS OF INSTALLED HOT OIL HEATER AS PER APPROVED TEST PROCEDURE DATED 25OCT79.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Engineering
Issued 1 May 1990
Resolved
PROVIDE INSULATION FOR HOT OIL DIESEL ENGINE.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Engineering
Issued 1 May 1990
Resolved
REPLACE ALL RUBBER FUEL HOSES ON HOT OIL HEATER AND MOUNT F/O FILTERS. (FIRE RES. WIRE REINFORCEMENT AS REQ BY 46 CFR 56.60-25)
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Engineering
Issued 1 May 1990
Resolved
REPAIR ALL EXHAUST LEAKS ON HOT OIL HEATER.
Condition: Unknown
Due 1 May 1990
Resolved 1 May 1990
Accommodation/Occupational Safety
Issued 23 January 1989
Resolved
INSTALL SUITABLE MARINE SANITATION DEVICE IN ACCORDANCE WITH 33 CFR 159.7. DEVICE MAYBE EITHER A TYPE II OR III.
Condition: Unknown
Due 23 January 1989
Resolved 23 January 1989