Records from 1981 to 2026. Most recent: inspection, 4 June 2026.
Inspection history · 81
4 June 2026
Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8391366
21 May 2026
Deficiency Check · Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8347131
8 July 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7912591
6 June 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7929518
23 May 2023
Annual Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7676998
2 June 2022
Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7465892
2 May 2022
Deadweight Survey · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7442834
12 July 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7253849
29 July 2020
Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7012795
24 June 2020
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6985759
5 June 2019
Administrative Inspection · Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6702715
10 July 2018
Internal Structural Exam · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6475056
1 May 2018
Administrative Inspection · Annual Inspection · Internal Structural Exam · Plan Review "T" Boat
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6405347
13 June 2017
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6175219
17 May 2017
COI Inspection · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6146843
20 July 2016
Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5946499
4 April 2016
Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5847045
24 June 2014
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4901827
17 June 2014
Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4877776
18 June 2012
Drydock Exam · Deficiency Check · Plan Review "T" Boat · COI Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4348037
7 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4203853
27 January 2009
Administrative Inspection · Re-Inspection · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3411528
8 October 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3427070
19 August 2008
Damage Survey · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3325612
15 May 2008
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3207438
14 February 2007
Deficiency Check · COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2872008
20 June 2006
Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2686087
2 May 2006
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2646778
22 March 2006
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2607534
14 April 2005
Examination of Repairs · Hull Examination · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2334132
17 December 2004
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2261188
1 June 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2088358
3 September 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1899802
2 September 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1900079
20 June 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1848014
4 June 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1809787
8 April 2003
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1770134
7 November 2002
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1906402
13 September 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1677650
12 July 2002
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1653835
18 April 2002
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1606717
20 June 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472067
12 April 2001
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451678
23 June 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1365840
12 May 1999
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447942
8 May 1998
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 789893
27 April 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 22890
10 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 781645
16 July 1997
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425944
6 June 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450036
27 May 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1085489
24 May 1996
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1411311
29 August 1995
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355444
25 May 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385451
27 May 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392008
3 December 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 848106
4 November 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1151691
28 September 1993
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1428272
29 May 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1450773
20 January 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 829704
23 September 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 935887
3 August 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401633
4 October 1991
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 934288
18 April 1991
Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 912715
25 October 1990
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1218210
4 November 1989
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1224041
2 November 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1202949
9 November 1987
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1334418
22 September 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007429
23 October 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016461
14 January 1986
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1317983
6 August 1985
Credit Drydock · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300587
21 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292018
2 August 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1282584
4 August 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274705
10 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964991
11 February 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 965441
3 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277205
5 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275977
3 August 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272689
3 August 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281682
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 21 May 2026
Resolved
The following tests and inspections must be carried out weekly on a vessel:(a) Each survival craft, rescue boat, and launching appliance must be visually inspected to ensure its readiness for use. Weekly inspections of IBAs not conducted or logged. Conduct weekly inspection and establish log to satisfaction of attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2026
Resolved 26 May 2026
Resolution: Weekly inspection completed and logged
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 21 May 2026
Resolved
Each survival craft, rescue boat, and launching appliance on a vessel must be inspected monthly, using the manufacturer's instructions to make sure it is complete and in good order. Monthly inspections of IBAs not conducted or logged. Conduct monthly inspection and establish log to satisfaction of attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2026
Resolved 26 May 2026
Resolution: Monthly inspection completed and logged
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 21 May 2026
Resolved
Electrical equipment on a vessel must be installed and maintained to: (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead end wiring found behind breaker panel in galley. Remove wiring or cover dead ends to satisfaction of attending marine inspector.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2026
Resolved 26 May 2026
Resolution: Dead end wiring capped.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 May 2026
Resolved
Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Pressure gauge on starboard-side bilge pump (also may be used as fire pump) is inoperable. Replace gauge and demonstrate satisfactory operation to attending marine inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2026
Resolved 27 May 2026
Resolution: Gauge replaced.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 8 July 2024
Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Areas of major pitting discovered on the outside of the hull in the following locations: Stern lazarette, fwd rudder compartment above rudder, fwd rudder compartment aft of rudder. Submit a repair proposal for pitting to the satisfaction of Marine Inspector.
Action required: 705 - Other - as specified
Resolved 22 July 2024
Resolution: Finals weld repairs passed NDT to the satisfaction of attending marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 8 July 2024
Resolved
A vessel must comply with the structural design requirements of one of the standards listed. Areas of minor pitting discovered around vessel repair in accordance with discussed repair proposal.
Action required: 705 - Other - as specified
Resolved 15 July 2024
Resolution: Minor pitting ground and sealed to the satisfaction of marine inspector.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 6 June 2024
Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60
pounds per square inch (PSI) at the pump outlet. The pump outlet shall be fitted with a pressure gage. The fire pump outlet gage pressure reading was 40 psi. Prove fire pump outlet pressure of 60 psi by June 11, 2024, to the satisfaction of the attending Marine Inspector.
46 CFR 181.10-1(c)
Old T
Action required: 705 - Other - as specified
Due 11 June 2024
Resolved 18 June 2024
Resolution: Observed fire pump pressure at the outlet gauge of 80 psi with two hoses discharging; all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 6 June 2024
Resolved
Except as otherwise provided in this paragraph all unfired pressure vessels shall be Coast Guard approved and installed to the satisfaction of the Officer in Charge, Marine Inspection. The requirements for design, construction and original testing of such approved unfired pressure vessels are in applicable regulations in Sub-chapter F of this chapter. Stbd air compressor safety valve relieving at 100 psi prevent unfired pressure vessel safety relief valve test. Repair stbd air compressor to satisfactory conducted relief valve test as described by 46 CFR 61.10-5(i)(2) in the presence of the attending Marine Inspector.
46 CFR 182.10-5(d)
Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 13 June 2024
Resolution: Inspected new stbd air compressor and witnessed the stbd air receiver relief valve release at 150 psi and reseated unassisted; all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 June 2024
Resolved
A vessel must have one or more ring life buoys as follows: A vessel of more than 65 feet in length must carry a minimum of three life buoys of not less than 24 inches in diameter. All three ring life buoys plastic plugs are wasted. Replace ring life buoys to the satisfaction of the attending Marine Inspector.
46 CFR 180.70(a)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 13 June 2024
Resolution: Inspected the three new life ring buoys; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 June 2024
Resolved
A battery charger intended for connection to a commercial supply voltage shall employ a transformer of
the isolating type. An ammeter that is readily visible shall be included in the battery charger circuit. Port battery charger missing ammeter; 1) Install ammeter or 2) provide a battery charger with an integral ammeter. To the satisfaction of the attending Marine Inspector.
46 CFR 183.05-20(f)
Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 29 July 2024
Resolution: Vessel rep installed a new battery charger with an integral ammeter, correct UL 489 breaker, and AC breaker; all sat.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage comminuting and disinfecting system
Issued 6 June 2024
Resolved
A vessel with installed toilet facilities must have a marine sanitation device that complies with 33 CFR part 159. Type II MSD missing required placard as described by 33 CFR 159.59. Provide required placard tot he satisfaction of the attending Marine Inspector.
46 CFR 184.704
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 13 June 2024
Resolution: Required placarding posted at MSD; all sat.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 6 June 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. The fuel condition located on the port engine room bulkhead pump coupling is missing a protective guard and both steering pump couplings are missing protective guards. Install the required protective guards during the vessel's next dry dock in July 2024, to the satisfaction of the attending Marine Inspector.
46 CFR 176.830(a)
Action required: 705 - Other - as specified
Due 31 July 2024
Resolved 2 July 2024
Resolution: Received email from vessel rep of the protective guard installed on both steering pump couplings and fuel condition pump coupling.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 June 2024
Resolved
The marine employer shall ensure that all individuals engaged or employed on board a vessel are fully indoctrinated in the requirements of this subpart, and that appropriate vessel personnel are trained as necessary in the practical applications of these requirements. The marine employer shall take all practicable steps to have each individual engaged or employed on board the vessel who is directly involved in the incident chemically tested for evidence of drug and alcohol use as required. Company alcohol testing policy/procedures to be conducted in the event of a SMI (2 hr alcohol testing) while underway is not in place. Provide company policy/procedure to the satisfaction of the attending Marine Inspector.
46 CFR 4.06-1(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2024
Resolved 13 June 2024
Resolution: Company provided policy/procedure to the satisfaction of the attending Marine Inspector; all sat.
05 - Radio Communications › N/A - No Subsystem › Radio log (diary)
Issued 6 June 2024
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel radiotelephone installation required to comply with the Bridge to Bridge Act IAW 47 CFR 80.1001. Vessel does not have a Vessel Bridge-To-Bridge Radiotelephony Certificate, therefore is required to keep a station log required by 47 CFR 80.409(f) IAW 47 CFR 80.1005. Vessel station log missing required entries required by 47 CFR 80.409(f) described by 47 CFR 80.409(e). Provide and maintain the required station log or obtain a Vessel Bridge-To-Bridge Radiotelephony Certificate to the satisfaction of the attending Marine Inspector.
46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 June 2024
Resolved 2 July 2024
Resolution: Marine radio log in lieu of the Bridge-to Bridge Radiotelephony Certificate; all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 23 May 2023
Resolved
A vessel must comply with the structural design requirements of one of the standards listed. The vessel has two cracked welds in the forward port and starboard compartments aft of the collision bulkhead. One fractured deck support frame in the port compartment. Renew frame and scarf and reweld fractures.
46 CFR 177.300
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 July 2023
Resolved 21 July 2023
Resolution: Received email from vessel rep Mike with photographs of the cracked welds identified during the annual inspection repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 May 2023
Resolved
Irrespective of build date a vessel to which this subchapter applies must meet 46 CFR 181.405, 181.450, 181.500, 185.364, and 185.420(b), if it is not a ferry, and if it — (1) Has overnight accommodations for passengers; or (2) Is operating on a Coastwise or Oceans route. Carriage of overnight passengers is not permitted and the vessels route is restricted to Limited Coastwise while carrying passengers until the following items are complied with: 181.405, 181.450, 185.364, 185.420(b) to the satisfaction of the attending MI.
46 CFR 175.110(c)
Action required: 705 - Other - as specified
Resolved 20 July 2023
Resolution: Attended vessel and confirmed the items noted above were complied with; all sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 May 2023
Resolved
Irrespective of build date, a vessel to which this subchapter applies must meet 46 CFR 177.115(c), 177.500(n), 185.410(b), 185.507, and 185.515, if it is not a ferry and has overnight accommodations for passengers.
Carriage of overnight passengers is not permitted until the following items are complied with: 185.410(b), 185.507, and 185.515 to the satisfaction of the attending MI.
46 CFR 175.110(d)
Action required: 705 - Other - as specified
Resolved 20 July 2023
Resolution: Attended vessel and confirmed the items noted above were complied with; all sat.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 May 2022
Resolved
Cable and wire for power and lighting circuits must: be listed by Underwriters Laboratories(UL), as UL Boat or UL Marine cable. Hardwire fuel recirculating pump cable and replace cable with Marine Grade wire to the satisfaction of the Marine Inspector.
46 CFR 183.340(d)(2)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 May 2022
Resolution: Provided picture verification that all electrical equipment is installed as required.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 May 2022
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels who occupy a position or perform the duties and functions of a position, required by the vessel's COI. Marine employers may form or otherwise use sponsoring organizations, or may use contractors to conduct the random chemical testing programs. Provide satisfactory evidence of a chemical testing program to the satisfaction of the attending Marine inspector.
46 CFR 16.230(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 May 2022
Resolution: Vessel provided documents for DAPI program via email.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 12 July 2021
Resolved
A vessel must comply with the structural design requirements of one of the standards listed. The vessel has an approximately two inch cracked weld connecting the longitudinal deck frame members in the engine compartment. Submit a repair proposal for approval IAW NVIC 7-68.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 17 August 2021
Resolution: Vessel repaired cracked weld according to accepted repair proposal.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 July 2021
Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit had expired aspirin, replace with new aspirin.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 July 2021
Resolved 26 July 2021
Resolution: Vessel purchased new aspirin for first aid kit.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 24 June 2020
Resolved
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter meeting the requirements of § 80.1101(c)(3) and capable of transmitting J3E emission and a receiver capable of reception of J3E emission within the band 1710 to 2850 kHz, in addition to the VHF-DSC radiotelephone installation required by paragraph (a)(1) of this section. VHF radio missing MMSI and LAT/LONG for DSC operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2020
Resolved 25 June 2020
Resolution: New radio installed with programmed MMSI and functional GPS.
Engineering › Pressure Vessel › Relief Valve
Issued 1 May 2018
Resolved
Install water heater relief valve rated at not more than 100psig and 250 degrees F.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 14 May 2018
Resolution: Verified installation of correct water heater relief valve.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 13 June 2017
Resolved
Provide electrical load analysis and line diagram for newly installed eletrical equipment to be locally approved to meet standards outlined IAW 46 CFR 183.
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 26 September 2017
Resolution: Electrical load analysis and line diagrams submitted and reviewed by Sector Hono OCMI.
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 May 2017
Resolved
Provide appropriate insulation on bare wire under conning station IAW 46 CFR 111.60
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: Provided appropriate insulation on bare wire under conning station
Electrical › Electrical Distribution System (service) › Wiring
Issued 17 May 2017
Resolved
Clean identified corrosion occuring on wiring under conning station IAW 46 CFR 183.210
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: Cleaned identified corrosion occuring on wiring under conning station
Electrical › Electrical Distribution System (emergency) › Fuse
Issued 17 May 2017
Resolved
Replace blade type fueses prior to emergency switches with cartridge type UL Listed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: Replaced blade type fueses prior to emergency switches with cartridge type UL Listed
Stability › Watertight Integrity › General
Issued 17 May 2017
Resolved
Replace gasket on watertight door located between engine room and lazarette.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: Replaced gasket on watertight door located between engine room and lazarette
Stability › Watertight Integrity › General
Issued 17 May 2017
Resolved
Repair knife edge in the top right corner of the watertight door located between the crew area and apassenger area to make a complete seal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: Repaired knife edge of the watertight door
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 17 May 2017
Resolved
Replace circuit breakers in main distribution panel with UL listed circuit breakers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: Replaced circuit breakers in main distribution panel with UL listed circuit breaker
Documentation › Certificates/Documents › Stability Letter
Issued 23 June 2012
Resolved
Vessel is limited to the carriage of 29 passengers and 12 long tons of deck cargo until provided with approved stability letter from MSC.
Action required: 705 - Other - as specified
Due 6 July 2012
Resolved 5 July 2012
Resolution: Received Stability Letter.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 June 2012
Resolved
Prove proper rail / courses for port and stbd gangways.
Action required: 705 - Other - as specified
Resolved 23 June 2012
Resolution: Inspected satisfactorily.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 21 June 2012
Resolved
Replace port aft cutlass bearing in strut.
Action required: 705 - Other - as specified
Resolved 23 June 2012
Resolution: Inspected satisfactorily.
Stability › Watertight Integrity › General
Issued 18 June 2012
Resolved
Make cable run penetrating portside engineroom watertight.
Action required: 705 - Other - as specified
Resolved 23 June 2012
Resolution: Inspected satisfactorily.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 18 June 2012
Resolved
Secure deck access hatches in the engineroom (trip / fall hazard)
Action required: 705 - Other - as specified
Resolved 23 June 2012
Resolution: Inspected satisfactorily.
Stability › Watertight Integrity › General
Issued 18 June 2012
Resolved
Prove proper operation of all watertight doors.
Action required: 705 - Other - as specified
Resolved 23 June 2012
Resolution: Inspected satisfactorily.
Stability › Weathertight Integrity › General
Issued 18 June 2012
Resolved
Prove proper operation of all weathertight openings.
Action required: 705 - Other - as specified
Resolved 23 June 2012
Resolution: Inspected satisfactorily.
Engineering › Fuel Oil Service System › Valve
Issued 18 June 2012
Resolved
Prove proper operation of emergency fuel shut-off for stbd tank.
Action required: 705 - Other - as specified
Resolved 23 June 2012
Resolution: Inspected satisfactorily.
Engineering › Fuel Oil Service System › Filter
Issued 18 June 2012
Resolved
Attach additional supports for portside main engine fuel filter.
Action required: 705 - Other - as specified
Resolved 23 June 2012
Resolution: Inspected satisfactorily.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 June 2012
Resolved
Properly label all emergency lighting fixtures.
Action required: 705 - Other - as specified
Resolved 23 June 2012
Resolution: Inspected satisfactorily.
Electrical › Lighting (service) › Switch
Issued 18 June 2012
Resolved
Properly repair switch to engineroom lighting.
Action required: 705 - Other - as specified
Resolved 23 June 2012
Resolution: Inspected satisfactorily.
Electrical › Electrical Distribution System (service) › Cable
Issued 18 June 2012
Resolved
Remove dead-end cables in engineroom.
Action required: 705 - Other - as specified
Resolved 23 June 2012
Resolution: Inspected satisfactorily.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 18 June 2012
Resolved
Repair / replace stbd fan guard in generator space.
Action required: 705 - Other - as specified
Resolved 23 June 2012
Resolution: Inspected satisfactorily.
Engineering › Fuel Oil Service System › Piping
Issued 18 June 2012
Resolved
Repair fuel leaks on main engine primer pumps and main engine fuel supply lines.
Action required: 705 - Other - as specified
Resolved 23 June 2012
Resolution: Inspected satisfactorily.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 18 June 2012
Resolved
Provide gangway and ladder system to be visually inspected by CG Inspector.
Action required: 705 - Other - as specified
Resolved 21 June 2012
Resolution: Inspected satisfactorily. Issued additional worklist item for rail / course requirements.
Operations/Management › Drills/Instruction › Fire
Issued 18 June 2012
Resolved
Update emergency procedures.
Action required: 705 - Other - as specified
Resolved 23 June 2012
Resolution: Inspected satisfactorily.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 18 June 2012
Resolved
Prove proper operation of port and center shaft assemblies.
Action required: 705 - Other - as specified
Resolved 23 June 2012
Resolution: Inspected satisfactorily.
Operations/Management › Drills/Instruction › Safety Orientation
Issued 18 June 2012
Resolved
Re-word passenger brief to state passengers not allowed on deck while underway.
Action required: 705 - Other - as specified
Resolved 23 June 2012
Resolution: Inspected satisfactorily.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 18 June 2012
Resolved
Prove proper operation of stbd shaft log.
Action required: 705 - Other - as specified
Resolved 23 June 2012
Resolution: Inspected satisfactorily.
Stability › Incline Test › General
Issued 7 December 2011
Resolved
Vessel has failed to comply with the new stability standard for passenger weight that went into effect on 01DEC11, which changed the passenger weight from 160lbs to 185lbs. Vessel restricted to the carriage of 40 passengers.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 23 June 2012
Resolution: New Incline Stability Test conducted, awaiting stability letter from MSC.
Electrical › Lighting (service) › Lighting Fixture
Issued 15 May 2008
Resolved
Hard wire existing light.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2008
Resolution: Electrician rewired fixed lighting.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 15 May 2008
Resolved
Soft patch for enginroom leaking. Remove deck board and seal soft patch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2008
Resolution: Crew sealed soft patch over engineroom. Inspectors witnessed water test to ensure tightness.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 15 May 2008
Resolved
Replace foam gasket in WTD from engine room to rudder room with rubber gasket.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2008
Resolution: Appropriate gasket material placed on hatch.
Documentation › Safety Management System › Critical Equipment/Systems ID Procedures
Issued 15 May 2008
Resolved
Provide proof of lifesaving equiptment maintenance.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2008
Resolution: Vessel master initiated record book for lifesaving maintenance.
Communications › Radio Communications › VHF Radiotelephone
Issued 15 May 2008
Resolved
1st Mate needs radio operators certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2008
Resolution: First mate showed proof of completion for radio operators certificate.
Electrical › Electric Supply System (service) › Cable
Issued 14 February 2007
Resolved
Renew electrical cabling in passenger void areas. Junction box needs waterproof top due to mop water on deck.
Due 5 March 2007
Resolved 26 February 2007
Resolution: Renewed electical cabling and placed waterproof cover on junction box.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 14 February 2007
Resolved
Provide current copy of Navigation Rules for vessel.
Due 5 March 2007
Resolved 26 February 2007
Resolution: Provided copy of Navigation Rules for vessel.
Engineering › Pressure Vessel › Pressure Gauge
Issued 14 February 2007
Resolved
Renew Pressure gauges.
Due 5 March 2007
Resolved 26 February 2007
Resolution: Renewed pressure gauges.
Accommodation/Occupational Safety › Potable Water System › General
Issued 2 May 2006
Resolved
All potable water as used onboard drains directly into bilges. Remove water from machanery room and passenger space bilges and repair piping.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 20 June 2006
Resolution: Bilge area had some residual water which did not get pumped out. Observed new piping to the compartment that drains from the water closet/shower.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 2 May 2006
Resolved
Make watertight all watertight doors. Doors are warn and in need of repair/renewing.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 20 June 2006
Resolution: All watertight doors were sat.
Accommodation/Occupational Safety › Ventilation › General
Issued 2 May 2006
Resolved
Provide working generator space exhaust fan and provide guard for same.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 20 June 2006
Resolution: Observed a newly installed fan with guard.
Engineering › Sea-water System (primary cooling) › Piping
Issued 2 May 2006
Resolved
Properly run MDE raw water piping provide short section of flex hose only, as indicated.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 20 June 2006
Resolution: Piping/hoses were sat.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 May 2006
Resolved
Provide proper emergency lighting throughout vsl.
Action required: 705 - Other - as specified
Due 2 June 2006
Resolved 20 June 2006
Resolution: Emergency lights were operational with the exception of one blown bulb.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 26 April 2005
Resolved
Hydrostatically test Air Recievers prior to sailing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 April 2005
Resolved 26 April 2005
Resolution: Tested Air Receivers with sat results.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 1 June 2004
Resolved
Provide 3/4 full indicator for sewage tank at next drydock.
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 27 April 2005
Resolution: Level indicator installed, unable to test due to tank being closed. Special note for next Hull inspection will be to test float.
Electrical › Electrical Distribution System (service)
Issued 1 June 2004
Resolved
Panel board door does not properly close and breaker panel cover does not cover breakers properly. LEGACY COMPONENT DESC: Panelboard
Action required: 17 - Rectify deficiencies prior to departure
Due 4 June 2004
Resolved 3 June 2004
Resolution: Provided proper closure/door and renewed breaker cover.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 1 June 2004
Resolved
Engine exhaust hangers missing bolts. LEGACY COMPONENT DESC: Exhaust
Condition: Improper Installation
Due 4 June 2004
Resolved 3 June 2004
Resolution: Provided
Lifesaving › Buoyant Apparatus
Issued 1 June 2004
Resolved
Life float lifeline parted, provide service. LEGACY COMPONENT DESC: Lifeline
Condition: Damaged By Earlier Event
Due 4 June 2004
Resolved 3 June 2004
Resolution: Renewed life float.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 June 2004
Resolved
Navlights covered with paint spray and dirty.
Due 4 June 2004
Resolved 3 June 2004
Resolution: Renewed
Construction/Loadline › Hull
Issued 1 June 2004
Resolved
Overhead main beam leaking seawater iwo generator/rudder room. LEGACY COMPONENT DESC: Main Beam
Condition: Unknown
Due 4 June 2004
Resolved 3 June 2004
Resolution: Removed deck boards found fracture and gouged and welded.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 1 June 2004
Resolved
Engine room and mach space not properly lighted during loss of power.
Due 4 June 2004
Resolved 3 June 2004
Resolution: Provided proper emergency lighting.
Fire Fighting › Portable Foam Applicators
Issued 8 April 2003
Resolved
Provide fire fighting equipment required for Marine Portable Tank endorsement prior to transporting marine portable tanks. LEGACY COMPONENT DESC: Marine Portable Tanks
Due 16 May 2003
Resolved 1 June 2004
Resolution: Provided.
Fire Fighting › Ventilation Systems
Issued 8 April 2003
Resolved
Provide flame screen for sewage vent. LEGACY COMPONENT DESC: Flame Screen
Due 16 May 2003
Resolved 17 May 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 18 April 2002
Resolved
NO FLAME SCREEN ON LUBE OIL TANK VENT.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2002
Resolved 18 April 2002
Engineering › Fuel Oil Service System › Piping
Issued 18 April 2002
Resolved
FUEL OIL PIPING ON STARBOARD MAIN ENGINE LEAKING FUEL OIL.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 April 2002
Resolved 18 April 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 April 2002
Resolved
WIRING CONNECTIONS ON PORT AIR COMPRESSOR LOOSE.
Due 18 April 2002
Resolved 18 April 2002
Navigation › Piloting/Steering
Issued 18 April 2002
Resolved
RETAINING PIN ON PORT RUDDER MISSING. LEGACY COMPONENT DESC: RUDDER
Action required: 17 - Rectify deficiencies prior to departure
Due 18 April 2002
Resolved 18 April 2002
Lifesaving
Issued 20 June 2001
Resolved
INSTALL PUBLIC ADDRESS SYSTEM TO BE AUDIBLE IN DURING NORMAL OPERATING CONDITIONS THROUGHOUT THE ACCOMMODATION SPACES AND ALL OTHER SPACES NORMALLY MANNED BY CREW MEMBERS TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 20 July 2001
Resolved 29 June 2001
Navigation
Issued 2 August 1984
Resolved
PROVIDE SUITABLE CHARTS AND PUBLICATIONS IN ACCORDANCE WITH CURRENT DIRECTIVES AND REGULATIONS.
Condition: Unknown
Due 2 August 1984
Resolved 2 August 1984
Lifesaving
Issued 2 August 1984
Resolved
PROVIDE LIFEJACKET DONNING INSTRUCTIONS ON UPPER AND LOWER PASSENGER SEAT- ING AREAS.
Condition: Unknown
Due 2 August 1984
Resolved 2 August 1984
Fire Fighting
Issued 2 August 1984
Resolved
INSTALL GUARD AT FIRE PUMP TO MOTOR COUPLING.
Condition: Unknown
Due 2 August 1984
Resolved 2 August 1984
Electrical
Issued 2 August 1984
Resolved
RENEW WIRING TO AIR CONDITIONER COMPRESSOR IN ACCORDANCE WITH CURRENT REGULATIONS.
Condition: Unknown
Due 2 August 1984
Resolved 2 August 1984
Electrical
Issued 2 August 1984
Resolved
INSTALL RAIN TIGHT CONTROL BOX TO SEWAGE.
Condition: Unknown
Due 2 August 1984
Resolved 2 August 1984
Construction/Loadline
Issued 11 February 1983
Resolved
EFFECT PERMANENT REPAIRS TO THE FRACTURED STIFFNER ON THE STERN SIDESHELL IN WAY OF THE LUBE OIL TANK.
Condition: Unknown
Due 11 February 1983
Resolved 11 February 1983