Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southwest District (CGD-SW) · Other hulls named ICON
ICON is a 1981 passenger vessel (inspected). The Coast Guard has recorded 101 inspections since 1981, most recently in March 2026, along with 113 deficiencies, 3 operational controls and 2 casualty investigations between 2015 and 2021.
Records from 1981 to 2026. Most recent: inspection, 23 March 2026.
- Built
- 1981
- Last inspected
- 23 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Inspections
- 101
- Deficiencies
- 113 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2015–2021
Identity
640204
WDK7426
53343
Flag
UNITED STATES
366740660, 368084360
Maury page id
psix-53343
Inspections, by type
…with no type recorded23
Years with a record
43 calendar years (1981–2026)
The 101 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)105.0 ft × 25.6 ft × 6.9 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)105.0 ft × 25.6 ft × 6.9 ft
ITC tonnageNot recorded
BuilderCAMCRAFT INC · JEAN LAFITTE, LA, UNITED STATES · built 1981
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEWPORT BEACH, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDK7426MMSI 368084360 · active · compulsorily equipped · granted 29 March 2019, expires 29 March 2029
WCX8339MMSI 366740660 · active · voluntarily equipped · granted 9 September 2017, expires 13 November 2027
WDA4286MMSI 366807750 · cancelled · voluntarily equipped · granted 13 April 2001, cancelled 7 May 2001
WDA4287MMSI 366807760 · cancelled · voluntarily equipped · granted 13 April 2001, cancelled 7 May 2001
WDA4288MMSI 366807770 · cancelled · voluntarily equipped · granted 13 April 2001, cancelled 7 May 2001
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 101
23 March 2026
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8254254
24 March 2025
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8077664
6 February 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7831398
7 April 2023
Hull Examination · Inclining Experiment · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7664225
30 December 2022
COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7602787
24 September 2022
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7557985
16 May 2022
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7452402
17 March 2022
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7413850
19 January 2022
Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7301371
15 August 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7290461
11 July 2021
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7251889
24 February 2021
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7144134
7 January 2020
Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6849922
18 October 2019
Deficiency Check · Annual Inspection · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6832247
25 March 2019
Internal Structural Exam · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6611962
10 April 2018
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6389139
9 January 2018
Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6318086
4 January 2018
COI Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6317937
7 February 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6059059
8 March 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5799680
7 January 2016
Internal Structural Exam · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5748909
15 December 2015
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5783855
17 January 2012
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4193231
17 January 2012
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4227233
2 December 2011
Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4200054
25 January 2011
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3935026
22 September 2010
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3856360
6 January 2010
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3659884
6 January 2010
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3659887
15 December 2009
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3651333
11 May 2009
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3488944
20 January 2009
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3361935
14 January 2009
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3361934
30 June 2008
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3252907
10 January 2008
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3125384
30 January 2007
Hull Examination · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2801773
9 January 2007
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2801780
31 March 2006
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2610568
7 February 2006
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2581199
13 January 2005
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2274493
7 January 2005
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2270821
4 January 2005
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2268544
10 February 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2001702
19 February 2003
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1744293
9 January 2003
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1727970
19 July 2002
Deficiency Check · Plan Review "T" Boat
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1650478
11 July 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1660922
28 March 2002
Construction Oversight · Plan Review "T" Boat
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1626220
26 March 2002
In-Service Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1598354
6 February 2002
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1484602
12 February 2001
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1373322
24 January 2001
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1373305
10 January 2001
Inclining Experiment
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1366122
27 October 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1055000
25 January 2000
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1369487
19 January 2000
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1369488
28 September 1999
Inclining Experiment
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1433554
27 April 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 791339
12 April 1999
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 787942
11 February 1999
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1467588
26 January 1999
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1123412
5 November 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1364918
24 September 1998
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 801407
26 May 1998
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1381250
5 February 1998
Hull Examination · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1446622
8 August 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1443910
5 June 1997
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 774666
18 February 1997
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1400495
24 January 1997
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1400483
7 August 1996
Excursion Permit
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1091064
20 February 1996
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 882359
8 January 1996
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1411225
20 January 1995
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 871227
10 January 1995
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1356961
5 January 1995
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1471957
14 March 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 854518
11 March 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1164813
26 January 1994
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1458131
10 January 1994
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1161185
5 January 1994
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1377101
17 August 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 673007
17 August 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 673008
31 July 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 213578
31 July 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 229294
25 January 1993
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 835687
13 January 1993
Initial Certification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 829021
22 November 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 952677
2 August 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 926513
24 October 1989
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1303053
22 August 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1034134
23 August 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1346704
19 May 1988
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1044164
12 September 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315551
5 September 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1313018
30 July 1986
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293573
5 September 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300803
29 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1291292
7 September 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282537
1 September 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277228
31 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273948
10 September 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969447
Deficiency record · 113
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 24 March 2025
Resolved
A hatch in a cabin top must be weather tight. Galley hatch does not dog down correctly.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 15 August 2023
Resolved
The master shall determine that the vessel complies with all applicable stability requirements. Vessel is currently awaiting approval of stability test/incline experiment from MSC. Vessel is restricted to lakes, bays and sounds route until final approval is received from MSC.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 December 2022
Resolved
Each life jacket kept in a stowage container must be readily available. Numerous type 1 life jackets were found not ready for immediate use as the adjustment strap D rings were corroded and seized in place not allowing for adjustment by passengers. Repair/replace all corroded D ring adjustment straps and ensure all life jackets on board are ready for immediate use.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 December 2022
Resolved
Internal combustion engine exhausts, boiler and galley uptakes, and similar sources of ignition must be kept clear of and suitably insulated from combustible material. STBD generator turbo was not insulated/covered with lagging to prevent a possible ignition of fuel or other combustible material. Provide adequate lagging/insulation for turbo on STBD gen-set.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 30 December 2022
Resolved
To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date. EPIRB registration is required every 2 years with NOAA. Provide up-to-date NOAA registration for vessel EPIRB and adhere NOAA sticker to EPIRB body.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 30 December 2022
Resolved
Gauges to indicate cooling water discharge temperature and lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator. Port engine gauges were found to be inoperable and not providing correct information. Repair/replace gauges and demonstrate proper operation of port engine gauges.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 30 December 2022
Resolved
The floating water-light must be attached around the body of the life float by a 10 mm (3/8 inch) lanyard resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. Water-lights for 06 life floats were found with lanyards that were an estimated 6-7 feet. Provide lanyards that are at least 18 feet for each life float water-light and to the specifications mentioned above.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 February 2021
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment under all practical conditions. Vessel could not prove proper suction from bilge engine room space. Vessel to provide satisfactory evidence of bilge suction.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 24 February 2021
Resolved
At each subsequent inspection for certification, the marine inspector may require that an abandon ship drill/man overboard drill be held. Vessel was unable to get underway to perform drills. MI to witness satisfactory drills prior to endorsement of Annual Inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 24 February 2021
Resolved
Life floats must not be stowed in tiers more than 4 feet high. when stowed in tiers, the separate units must be kept apart by spacers. MI observed life floats stuck together due to not having adequate spacers. Vessel to provide proper spacers between life floats.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 24 February 2021
Resolved
When a flexible fill pipe section is necessary, the metallic sections of the fill pipe must be joined by a conductor for protection against generation of a static charge when filling with fuel. Vessel does not have a proper conductor joining the metallic portions of the port and starboard fill pipes. Vessel to provide a proper conductor on both the port and starboard fill pipes.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 21 February 2020
Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Vessel currently conducted temporary repairs to the sewage tank and bulkhead #10. Vessel to conduct permanent repairs to the sewage tank & main traverse bulkhead #10, as indicated.
Vessel is restricted to only operating on a lakes, bays sounds route until permanent repairs have been made & satisfactory NDT has been conducted on sewage tank & main traverse bulkhead #10.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 18 October 2019
Resolved
Adequate overcurrent protection shall be provided for each conductor. Identify and properly label all overcurrent protection in 05 electrical panels and verify proper wire sizing to satisfaction of attending marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 October 2019
Resolved
All electrical installations shall be to the satisfaction of the officer in charge of marine inspections. Clean up exposed electrical wiring in engine room and under deck plates of passenger accommodation spaces.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 March 2019
Resolved
A VESSEL MUST COMPLY WITH THE APPLICABLE REQUIREMENTS FOR ANY RADIO INSTALLATIONS AS SET FORTH BY THE FCC IN 47 CFR PART 80. FCC CERTIFICATES ARE EXPIRED ON BOARD. PROVIDE CURRENT FCC STATION LICENCE, SAFETY CERT, AND BRIDGE TO BRIDGE CERT IAW 47 CFR PART 80.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 March 2019
Resolved
EPIRB MUST BE TESTED MONTHLY AND SHALL BE LOGGED OR OTHERWISE DOCUMENTED. VESSEL DOES NOT HAVE CURRENT EPIRB TESTING LOG. PROVIDE EPIRB TESTING LOG IAW CITE.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 March 2019
Resolved
THE MARINE EMPLOYER MUST AHVE A SUFFICIENT NUMBER OF ALCOHOL TESTING DEVICES READILY ACCESSIBLE ON BOARD. VESSEL HAD EXPIRED ALCOHOL TESTING DEVICES ON BOARD. PROVIDE CURRENT ALCOHOL TESTING STRIPS.
Engineering › Sea-water System (primary cooling) › Valve
Issued 9 January 2018
Resolved
Replace center main and starboard main sea suction valves.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 January 2018
Resolved
Relocate lifejackets to ensure that they are readily accessible to passengers in the event of an emergency.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 4 January 2018
Resolved
Replace or repair 30 lifejackets identified. The number of passengers and crew is reduced to 134 until completed to satisfaction of marine inspector.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 4 January 2018
Resolved
Provide latch or lock for oven to prevent opening while underway.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 February 2017
Resolved
Discovered dead end wire in the aft engine room.
Construction/Loadline › Hull › Hull Plating
Issued 8 March 2016
Resolved
Clad weld pit identified by inspector aft of Port Main Diesel Engine.
Construction/Loadline › Penetrations › Bottom Plug
Issued 8 March 2016
Resolved
Properly Cap unused through hull fittings (02) on Port side.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 2 December 2011
Resolved
Provide light cover for stateroom compartment forward baffle due to excessive electrical wiring.
Engineering › Bilge Water Management System › Piping
Issued 2 December 2011
Resolved
Label bilge manifold in engine room.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 2 December 2011
Resolved
Provide proper bracket for portable fire extinguisher on bridge.
Engineering › Fuel Oil Service System › Valve
Issued 2 December 2011
Resolved
Provide proper operation of port emergency fuel shut off valve.
Lifesaving › Lifefloat › Painter
Issued 25 January 2011
Resolved
Renew weather rotted painter lines to good line.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 25 January 2011
Resolved
Install smoke detector in forward cabin berthing.
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 January 2011
Resolved
Replace wasted starboard and port salt water supply lines.
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 25 January 2011
Resolved
Remove all chaffing conditions on lube oil hoses in engine room.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 January 2011
Resolved
Install protective cover (guard) over belt on starboard engine PTO.
Documentation › Markings/Placards › Lifejacket Placard
Issued 25 January 2011
Resolved
Mount life jacket location signs.
Documentation › Markings/Placards › Lifejacket Placard
Issued 25 January 2011
Resolved
Print and mount life jacket instruction placards.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 January 2011
Resolved
Replace missing lighting cover in generator room
Engineering › Fuel Oil Service System › Valve
Issued 25 January 2011
Resolved
Repair emergency fuel shutoff valve on starboard side. Valve found lose and unable to remain in open postion.
Engineering › Fuel Oil Service System › Piping
Issued 25 January 2011
Resolved
Replace fuel piping for port generator to meet requirements of J1942 standards. Generator was installed in 2000 and must meet new T requirements.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 January 2011
Resolved
Remove dead-end wiring from old generator.
Engineering › Lubricating Oil Service System › Gauge
Issued 25 January 2011
Resolved
Repair or replace oil p.s.i. gauge on main diesel engine in engine room.
Engineering › Lubricating Oil Service System › Gauge
Issued 25 January 2011
Resolved
Repair or replace exposed wiring on oil p.s.i. gauge sensor in way of fuel oil filters.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 25 January 2011
Resolved
Replace expired alcohol test strips.
Engineering › Pressure Vessel › Shell Plate
Issued 22 September 2010
Resolved
Conduct hydrostatic tests of (2) pressure vessels in E/R, in presence of CG marine inspector.
Electrical › Electric Generation Source (service) › Generator
Issued 20 January 2009
Resolved
Failed to start port ship service generator. Provide satisfactory demonstration of port ship service generator.
Construction/Loadline › Hull › Bottom Plating
Issued 14 January 2009
Resolved
Crop and replace to good metal area ship's hull port and starboard side in the way of the ship's sewage tank. Vessel is restricted to a Lakes, Bays and Sounds route until repairs completed.
Construction/Loadline › Hull › Bottom Plating
Issued 14 January 2009
Resolved
Replace or renew ship's sewage tank.
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 January 2008
Resolved
Replace damaged electrical cable in engine room. Determine source of over current. Provide single line electrical diagram.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 10 January 2008
Resolved
Water pump electrical is restricted from use (110 volt only). Circuit breaker removed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 10 January 2008
Resolved
Provide proof of annual fire extinguisher service. 46CFR176.810
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 10 January 2008
Resolved
Provide outlet cover as discussed, main deck port side interior. 46CFR183.200
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 January 2008
Resolved
Repair/replace starboard navigation light element mount inside fixture. 46CFR183.420
Operations/Management › Drug and Alcohol Testing › Testing, Reasonable Cause
Issued 6 February 2007
Resolved
Vessel was found not to be in compliance with company drug/free policy and chemical testing program, evidence of drugs were found onboard during routine dry-dock examination. Vessel owner to conduct reasonable cause testing in accordance with 46 CFR 16.250 for the Master and crew.
Engineering › Pressure Vessel › Shell Plate
Issued 30 January 2007
Resolved
Pressure Vessels overdue for hydrostatic inpsection.
Documentation › Certificates/Documents › FCC SSL
Issued 9 January 2007
Resolved
Provide current FCC station license.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 3 March 2006
Resolved
Provide smoke detector in each accommodation space; Carriage of overnight passengers prohibited until installed.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 3 March 2006
Resolved
Label each side of emergency exit in overhead of berthing area; also label outside of door to indicate emergency exit is located in space; carriage of overnight passengers prohibited until completed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 February 2006
Resolved
Install non corrosive clip on lanyard for floating waterlight
Operations/Management › Equipment Service/Testing › EPIRB
Issued 7 February 2006
Resolved
Register EPIRB through NOAA. Route restricted to 3 NM.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 7 February 2006
Resolved
Provide new hydrostatic release of EPIRB installation. Route restricted to 3 NM.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 7 February 2006
Resolved
Fill empty slots in #3 switchboard in engine room with appropriate blanks.
Accommodation/Occupational Safety › Sleeping Accommodations › People Per Room
Issued 7 February 2006
Resolved
Provide written request on number of passengers desired to be carried on overnight voyages. No overnight passengers allowed.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 February 2006
Resolved
Provide valid FCC station license.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 7 February 2006
Resolved
Label emergency escape leading from lazerette.
Fire Fighting › Means of Escape › Blocked
Issued 13 January 2005
Resolved
Make engineroom emergency exit between port and center main engines, more accessible. (move stanchion, with the approval of a structural engineer/architect)
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 January 2005
Resolved
Install metal supports on wiring IAW 46 CFR 183.340
Lifesaving › Inflatable Liferafts › Float Free
Issued 6 January 2005
Resolved
Have liferaft attached to the vessel by a painter w/ a float free arrangement IAW 46 CFR 180.130
Operations/Management › Equipment Service/Testing › EPIRB
Issued 9 January 2003
Resolved
Replace expiring EPIRB battery.
Stability › Watertight Integrity
Issued 19 July 2002
Resolved
Provide a new stability letter from the Marine Safety Center. ICON is restricted to Newport Harbor until this item is corrected. The 2 forward engine room ex-fuel tanks, port and starboard, must be 100% filled with water ballast and the transom watertight door closed while operating with pax. LEGACY COMPONENT DESC: Watertight door in transom
Accommodation/Occupational Safety
Issued 26 March 2002
Resolved
Emergency escape hatch was not labeled. Corrected before inspector's departed.
Lifesaving › Buoyant Apparatus
Issued 6 February 2002
Resolved
Replace dead battery on starboard lifefloat light. LEGACY COMPONENT DESC: Lifefloat Light
Navigation › Electronic Positioning
Issued 6 February 2002
Resolved
Install hydrostatic release on EPIRB. LEGACY COMPONENT DESC: Epirb
Electrical › Lighting (service) › Switch
Issued 6 February 2002
Resolved
Install cover over light switch in space below galley.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 February 2002
Resolved
Remove all old unused loose wiring from space below galley.
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 February 2002
Resolved
Install metal wire ties on loose wires in space below galley.
Lifesaving
Issued 24 January 2001
Resolved
Unknown Component - Unknown Cause/Condition
Engineering
Issued 24 January 2001
Resolved
Relief valves on port and starboard pressure vessels failed to relieve properly.
Lifesaving
Issued 10 January 2001
Resolved
Vessel is restricted to a Lakes, Bays and Sounds route on protected waters and must keep at least 50% capacity in all fuel tanks when passengers are on board. This applies to both inspected and uninspected passenger operations until a new stability letter is provided.
Unknown
Issued 25 January 2000
Resolved
Provide a urine collection kit on board.
Lifesaving
Issued 25 January 2000
Resolved
Post placard with 2 inch letters stating location of lifejackets in both below deck storage spaces.
Lifesaving
Issued 25 January 2000
Resolved
Post lifejacket donning placards visible to crew and passengers.
Lifesaving
Issued 25 January 2000
Resolved
Provide 6 new red flares and 3 new orange smoke signals prior to operating with passengers.
Unknown
Issued 25 January 2000
Resolved
Enact an Employee Assistance Program (EAP) IAW 46 CFR 16.401.
Lifesaving
Issued 25 January 2000
Resolved
Post placard leading to upper deck that states max capacity IAW stability letter.
Construction/Loadline
Issued 5 November 1998
Resolved
PERMANENTLY REMOVE WATERTIGHT DOOR ON THE TRANSOM. MAKE PERMANENT REPLATING ON TRANSOM CONSISTENT WITH APPLICABLE REGULATIONS (SUBMIT PLANS FOR REVIEW PRIOR TO CONSTRUCTION).
Documentation
Issued 5 November 1998
Resolved
PROVIDE AN UPDATED STABILITY LETTER REFLECTING UPPER DECK STRUCTURAL MODIFICATIONS (DEAD WEIGHT SURVEY).
Construction/Loadline
Issued 5 November 1998
Resolved
RENDER PORT AND STARBOARD STABILIZERS INOPERATIVE PENDING PLAN REVIEW AND APPROVAL.
Navigation
Issued 5 February 1998
Resolved
Replace improper navigation light bulbs at starboard and stern running lights.
Deck/Cargo
Issued 5 February 1998
Resolved
Repair or replace apparent leaks in hydraulic piping for bow thruster, windlass units at all bilge areas. Prove system leak-free to attending USCGinspector.
Construction/Loadline
Issued 5 February 1998
Resolved
Crop and renew holed through-hull coupler at waterline, stbd side in way ofgalley bilge.
Engineering
Issued 5 February 1998
Resolved
Provide approval/shop stamp review for s/s air receivers.
Construction/Loadline
Issued 5 February 1998
Resolved
Repair/replace inoperative bilge high level alarms. Demonstrate operation to USCG inspector.
Unknown
Issued 5 February 1998
Resolved
Provide evidence of compliance with 46 CFR part 4 with regards to on-board alcohol & urine sample test kits / breathalyzer.
Documentation
Issued 5 February 1998
Resolved
Provide for review of stability letter with regards to integral fuel tank usage/notation as ballast tanks.
Construction/Loadline
Issued 5 February 1998
Resolved
Repair fracture at aft engine room insert where watertight door was removed. (E.R. side, port side top radius).
Electrical
Issued 5 February 1998
Resolved
Prove proper operation of generator/shore power instruments at lazarette panel.
Documentation
Issued 5 February 1998
Resolved
Establish and maintain logs per 46 CFR part 185.
Accommodation/Occupational Safety
Issued 8 January 1996
Resolved
Have all pressure vessels hydrotested as per 46 CFR 176.25-32.
Lifesaving
Issued 10 January 1995
Resolved
REDUCE PASSENGERS TO 150 UNTIL 1 ADDITIONAL CHILD PFD IS PURCHASED.
Lifesaving
Issued 10 January 1995
Resolved
PERFORM MAN OVERBOARD AND FIRE DRILLS.
Engineering
Issued 10 January 1995
Resolved
REMOUNT LUBE OIL LEVEL INDICATOR ON STARBOARD MDE.
Engineering
Issued 10 January 1994
Resolved
PROVE PROPER OPERATION OF RELIEF VALVES ON BOTH AIR RECEIVERS.
Accommodation/Occupational Safety
Issued 10 January 1994
Resolved
INSTALL LOCKING DEVICE TO REACH ROD ON MSD OVERBOARD DISCHARGE VALVE.
Electrical
Issued 10 January 1994
Resolved
BLANK OPENING IN CIRCUIT BREAKER PANEL NEAR THE FIRE PUMP.
Lifesaving
Issued 10 January 1994
Resolved
PRIOR TO THE CARRIAGE OF MORE THAN 135 PERSONS ON BOARD ON COASTWISE ROUTE,PROPERLY REPAIR THE STARBOARD/AFT 20 PERSON BUOYANT APPARATUS.
Accommodation/Occupational Safety
Issued 10 January 1994
Resolved
PROVIDE A COVER TO THE HOLE IN THE BULKHEAD NEAR THE GALLEY.
Electrical
Issued 10 January 1994
Resolved
PROVE PROPER OPERATION OF THE EMERGENCY LIGHTING.
Navigation
Issued 10 January 1994
Resolved
PROVIDE LOCKING NUT OR DOUBLE NUT ON AUTO PILOT STEERING GEAR CONNECTION
Electrical
Issued 10 January 1994
Resolved
PROVIDE PROPER BATTERY CONNECTION IN ACCORDANCE WITH GOOD MARINE PRACTICE ON BRIDGE AND GENERATOR ROOM BATTERIES.
Construction/Loadline
Issued 13 January 1993
Resolved
PROVIDE MEANS TO RAPIDLY OPEN EMERGENCY ESCAPE HATCH INSIDE THE ENGINEROOM.
Electrical
Issued 13 January 1993
Resolved
PROVIDE A SEPARATE CIRCUIT FOR EACH OF THE NAVIGATION LIGHTS CONNECTED _x001C_ TO AN INDICATOR PANEL._x001C_ _x001C_ _x001C_
Lifesaving
Issued 13 January 1993
Resolved
PROVIDE ONE(1) ADDITIONAL 10-PERSON BUOYANT APPARATUS. VESSEL IS LIMITED _x001C_TO 150 TOTAL PERSONS ON BOARD UNTIL REQUIREMENT IS COMPLETED. _x001C_ _x001C_
Documentation
Issued 13 January 1993
Resolved
PROVIDE PROOF OF DRUG TESTING PROGRAM FOR ALL CREW MEMBERS. PROVIDE A DESCRIPTION OF HOW THE RANDOM REQUIREMENT IS MET (TRULY RANDOM FOR EVEN THEOPERATOR) AND TEST RESULTS FROM A RANDOM TEST OF AT LEAST ONE CREW MEMBER.
Electrical
Issued 13 January 1993
Resolved
PROVIDE A REVISED ELECTRICAL SCHEMATIC DIAGRAM SHOWING NAVIGATION LIGHT'S _x001C_CIRCUIT, STEERING GEAR MOTORS' SEPARATE CIRCUIT BREAKER AND AIR COMPRESSOR_x001C_MOTORS' SEPARATE CIRCUIT BREAKER.
Casualty record · 2
15 December 2015Routine · role: Involved in a Marine Casualty · activity 5783855
15 August 2021Routine · role: Involved in a Marine Casualty · 1 injured · activity 7290461
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.