MAURY USCG vessel records Sign in
← All vessels

CATHLAMET

CATHLAMET is a 1981 passenger vessel (inspected). The Coast Guard has recorded 310 inspections since 1985, most recently in May 2026, along with 148 deficiencies and 42 casualty investigations between 2003 and 2026.

Records from 1985 to 2026. Most recent: inspection, 19 May 2026.

Built
1981
Last inspected
19 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7808138 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WYR7641
Flag
UNITED STATES
366773070
Maury page id
psix-53349

Inspections, by type

…with no type recorded88
Years with a record 41 calendar years (1985–2026)
The 310 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)301.4 ft × 78.7 ft × 23.4 ft
Registered tonnagegross 2,477 / net 1,772
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMARINE PWR & EQUIP CO INC · SEATTLE WA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSEATTLE, WA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 13 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2477 - Regulatory (Subpart C or D), Gross Ton
1772 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WYR7641MMSI 366773070 · active · compulsorily equipped · granted 21 August 2026, expires 13 November 2036
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 310

19 May 2026 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8401247
17 March 2026 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8327367
17 March 2026 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8341556
6 February 2026 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8307341
2 November 2025 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8262000
2 October 2025 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8219418
25 August 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8217988
25 August 2025 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8259407
29 July 2025 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8197011
16 July 2025 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8188341
23 April 2025 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8228012
16 April 2025 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8112990
27 January 2025 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8070567
26 January 2025 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8069963
7 November 2024 Deficiency Check · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8032215
2 October 2024 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8001664
3 June 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7942083
2 April 2024 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7901473
10 January 2024 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7847937
30 November 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7832011
18 November 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7826862
6 September 2023 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7775545
12 July 2023 Administrative Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7740972
3 April 2023 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7681301
2 April 2023 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7661480
16 March 2023 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7652074
31 August 2022 Administrative Inspection · Examination of Repairs · Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7557452
19 August 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7538283
28 July 2022 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7518624
26 May 2022 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7466840
6 April 2022 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7426124
22 December 2021 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7380653
29 November 2021 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7358756
29 November 2021 Re-Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7359603
26 October 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7340123
22 October 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7337991
1 October 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7325013
1 October 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7335682
31 August 2021 COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7300472
24 July 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7267125
24 July 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7269721
9 July 2021 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7272766
22 May 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7207082
22 May 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7213905
13 May 2021 Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7196101
18 February 2021 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7142644
9 February 2021 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7134947
17 November 2020 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7097892
24 June 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6986102
2 March 2020 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6912788
31 January 2020 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6915331
13 December 2019 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6873285
28 October 2019 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6844179
9 August 2019 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6777715
23 July 2019 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6761768
2 May 2019 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6659675
13 February 2019 Administrative Inspection · Deficiency Check · Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6625534
6 November 2018 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6576045
19 October 2018 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6564727
18 October 2018 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6564109
6 September 2018 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6534001
15 August 2018 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6533395
30 April 2018 MTSA Verification · Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6403538
29 March 2018 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6381129
7 February 2018 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6355984
31 October 2017 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6293504
10 August 2017 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6267390
20 July 2017 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6216348
27 April 2017 Security Breach, Potential
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6137047
19 April 2017 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6137961
16 April 2017 Security Breach, Potential
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6131529
16 February 2017 Security Breach, Potential
Type not classified · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6101103
20 January 2017 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6082797
17 January 2017 Underwater Inspection in lieu of Drydock · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6088899
12 January 2017 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6090002
20 October 2016 COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6024166
22 July 2016 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5953370
12 March 2016 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5833038
10 February 2016 MTSA Verification · Periodic Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5813100
29 November 2015 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5772867
19 November 2015 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5767731
4 November 2015 Deficiency Check · MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5757597
2 November 2015 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5756002
9 October 2015 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5739849
9 October 2015 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5752964
10 September 2015 Periodic Inspection · MTSA/ISPS Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5733571
15 August 2014 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4958690
15 August 2014 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4960782
5 March 2014 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4810372
26 July 2012 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4413871
27 June 2012 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4358223
27 June 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4358302
16 February 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4257097
31 January 2012 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4234462
23 January 2012 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4244954
20 January 2012 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4233271
29 December 2011 Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4228837
11 December 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4208892
5 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4201902
8 September 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4139363
3 August 2011 Damage Survey · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4104118
3 August 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4104298
8 July 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4074095
16 February 2011 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3946812
15 February 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3951676
25 January 2011 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3932880
24 November 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3900729
5 November 2010 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3891796
19 October 2010 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3877203
17 October 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3873745
28 September 2010 MTSA Verification · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3849221
23 March 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3704783
18 March 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3699227
2 March 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3697475
12 February 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3692748
28 January 2010 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3674811
27 January 2010 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3670699
24 December 2009 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3660604
30 April 2009 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3467212
7 April 2009 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3487876
27 March 2009 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3443856
13 January 2009 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3390478
15 December 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3384162
29 October 2008 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3353708
9 October 2008 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3341511
2 October 2008 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3337555
24 September 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3339545
15 July 2008 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3274643
5 July 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3262546
30 June 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3269712
16 April 2008 MTSA Verification · Re-Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3197516
11 March 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3163978
11 March 2008 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3185726
14 February 2008 Re-Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3151356
29 January 2008 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3138322
17 January 2008 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3135517
19 December 2007 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3126798
2 October 2007 COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3071632
5 July 2007 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2985529
4 July 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2989702
8 June 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3012025
6 June 2007 Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2958164
1 June 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2953608
3 May 2007 Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2921549
19 April 2007 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2911298
8 February 2007 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2869340
5 January 2007 Welding Related Inspections Qualification Testing
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2850939
2 October 2006 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2792256
22 September 2006 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2806397
26 July 2006 Examination of Repairs · Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2740074
14 July 2006 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2716867
29 June 2006 Re-Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2700087
29 June 2006 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2711545
7 April 2006 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2619633
9 March 2006 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2603149
3 February 2006 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2601838
26 January 2006 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2573796
6 October 2005 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2507844
20 July 2005 MTSA Verification · Re-Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2433714
29 April 2005 Re-Inspection · MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2345966
31 January 2005 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2284070
12 January 2005 Re-Inspection · MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2273838
23 November 2004 Spot Check · MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2246906
25 October 2004 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2226403
29 September 2004 Re-Inspection · MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2209039
15 September 2004 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2196389
20 June 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2105859
17 June 2004 Quarterly Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2101330
1 March 2004 Quarterly Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2015646
25 February 2004 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2013216
1 December 2003 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1955151
9 November 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1945172
9 November 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1949563
7 November 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1949515
30 September 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1924690
19 August 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1881294
16 August 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1879807
13 August 2003 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1876885
22 July 2003 Damage Survey · Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1854381
19 July 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1855306
17 July 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1860711
14 July 2003 Construction Oversight
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1846169
14 July 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1847253
19 December 2002 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1720583
12 December 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1726507
19 November 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1708968
18 November 2002 Quarterly Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1707252
13 September 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1679378
8 August 2002 Quarterly Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1660217
23 May 2002 Quarterly Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1627483
25 February 2002 COI Inspection · Hull Examination · MARPOL Annex I Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1489169
17 October 2001 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1074361
2 October 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1441908
16 August 2001 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1069048
12 July 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1445841
12 June 2001 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1066696
7 June 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1449478
26 April 2001 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1399607
29 March 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1412248
15 February 2001 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1058887
14 October 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 131186
10 October 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 215417
28 September 2000 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1412174
10 August 2000 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1053059
18 July 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 109746
10 May 2000 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1049884
28 March 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 81743
10 February 2000 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1391217
22 December 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 813732
26 October 1999 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1406593
23 October 1999 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1423278
1 August 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 123191
30 July 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 219255
27 July 1999 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1430716
14 July 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 49844
22 April 1999 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1391014
28 January 1999 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1423125
12 November 1998 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1413439
5 November 1998 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 804472
14 October 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1400858
20 July 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1457585
14 April 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 121286
7 April 1998 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1372201
16 January 1998 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1411593
8 December 1997 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1386140
18 November 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1107661
11 August 1997 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1409738
15 May 1997 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1404367
27 February 1997 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1445167
11 December 1996 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1383391
12 November 1996 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1363837
7 November 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 860391
6 August 1996 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1392509
2 May 1996 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1388013
30 January 1996 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1396436
19 October 1995 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1371195
18 July 1995 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1374340
28 April 1995 COI Inspection · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 867957
7 February 1995 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1394265
13 December 1994 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1385355
14 November 1994 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1174873
9 August 1994 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 862044
4 August 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1176095
19 July 1994 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1359867
6 May 1994 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1417645
30 March 1994 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1426885
22 March 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 83468
7 December 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 123737
25 August 1993 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 851185
18 August 1993 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1399903
3 August 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 63004
23 July 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 58739
28 June 1993 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 843799
24 May 1993 COI Inspection · Examination of Repairs · Deadweight Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1417511
20 July 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 187204
21 May 1992 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 953077
27 February 1992 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 957208
21 February 1992 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1269769
18 June 1991 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1199194
11 June 1991 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1011711
27 March 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 904085
15 March 1991 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 917876
10 January 1991 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 911917
28 November 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1229389
27 November 1990 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 912481
24 July 1990 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1230990
11 July 1990 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 932452
10 April 1990 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1225568
9 January 1990 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 914760
15 November 1989 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1213468
27 October 1989 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 996173
3 October 1989 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1011268
14 September 1989 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 898629
29 August 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1343352
25 August 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 889538
4 August 1989 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1205592
11 May 1989 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1203741
25 April 1989 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1347245
16 March 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1205104
27 February 1989 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1044075
10 November 1988 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 894037
14 July 1988 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1210186
29 April 1988 Deficiency Check · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1039718
5 January 1988 Deficiency Check · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1317114
14 October 1987 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1015240
31 July 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1025663
6 July 1987 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1016731
8 May 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1328455
7 April 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1020570
5 April 1987 Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1021662
6 March 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1009270
10 February 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1015136
9 February 1987 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1318346
6 February 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1318616
4 February 1987 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1313127
14 November 1986 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1323238
27 October 1986 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1012451
14 October 1986 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1007206
14 October 1986 Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1009628
3 October 1986 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1316293
26 September 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1003833
19 September 1986 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1310435
14 September 1986 Damage Survey · Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1000274
21 August 1986 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1294794
18 July 1986 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 991285
28 April 1986 Credit Drydock · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1308613
1 April 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 999193
23 August 1985 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 987916
13 August 1985 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1294740
14 May 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 983828

Deficiency record · 148

11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 17 March 2026 Resolved
Each passenger vessel of 500 tons gross tonnage and over must carry on each side of the vessel at least one rescue boat approved under approval series 160.156 that is equipped as specified in table 199.175 of this part. Vessel reported snapping throttle of rescue boat while conducting drills. Vessel is limited to half capacity until new rescue boat is installed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 17 March 2026
Resolution: recieved pictures of new rescue boat installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 2 November 2025 Resolved
Operating generators must provide a continuous and uninterrupted source of power for the ship's service load under normal operational conditions. While in route to Vashon, vessel experienced a marine casualty in the form of an unknown electrical ground which effected both SSDG. Vessel was able to safety moored at Vashon using the vital generator and the emergency generator. Vessel's Chief Engineer must provide a written statement attesting to the cause of the electrical ground and the corrective actions taken. The corrective actions must be to the satisfaction of the attending MI. 46 CFR 71.75-1 to 46 CFR 111.10-4(d)
Action required: 705 - Other - as specified
Due 2 November 2025
Resolved 2 November 2025
Resolution: See Narrative
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 25 August 2025 Resolved
Each passenger vessel of 500 tons gross tonnage and over must carry on each side of the vessel at least one rescue boat approved under series 160.156 that is equipped as specified in table 199.175 of this part. The #2 rescue boat on the port side #1 end is inoperable due to a failed throttle handle. Vessel shall reduce pax capacity by 50% until rescue boat is fully operational and tested.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 September 2025
Resolved 2 October 2025
Resolution: Verified repairs and operation of the throttle of the #2 rescue boat.
08 - Alarms › N/A - No Subsystem › Engineers' alarm
Issued 18 November 2023 Resolved
Electrical installations on vessels must ensure: Maintenance of services necessary for safety under normal and emergency conditions. Vessels 24 volt system alarm display is showing multiple alarm faults.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2023
Resolved 10 January 2024
Resolution: Confirmed proper operation of 24 volt panel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 September 2023 Resolved
Fitness of Service: In my opinion, this vessel at the time of inspection was in satisfactory condition for the route and service listed on the current COI. Vent dampers for the emergency generator space had significant gaps/did not close properly. Adjust for proper closure and eliminate gaps. *Witnessed correction on 07SEP23. 46CFR76.15-35
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 6 September 2023
Resolved 7 September 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 September 2023 Resolved
For each connected generator, each switchboard must have the following: (3) An indicator light connected between the generator and the circuit breaker. Indicator lights for #1 and #3 SSDGs do not indicate accurate status of the generators. Correct wiring for indicator lights within 30 days 46 CFR 111.30-25
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 October 2023
Resolved 23 October 2023
Resolution: WSF port engineer [name withheld] confirmed that the issue had been corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 July 2022 Resolved
Make permanent repairs to hull in way of port side number two end to the satisfaction of an attending Coast Guard Marine Inspector, crew to make periodic compartment checks during transit from Fauntleyroy to Eagle Harbor.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 December 2022
Resolved 28 March 2023
Resolution: Damage survey carried out activity 7557452.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 October 2021 Resolved
Vessel identified pin-hole leak on fire main at the pump. Soft patch installed and vessel permitted to continue operation. Hard patch to be installed at first available opportunity. Permanent repairs to be conducted at vessel's next scheduled drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 March 2022
Resolution: MI witnessed testing of fire main system while vessel was in drydock. all sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 October 2021 Resolved
Line shaft bearing located between reduction gear and propeller not functioning. Renew shaft bearing to full functionality prior to operating with passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 October 2021
Resolved 1 October 2021
Resolution: Line shaft bearing replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 February 2021 Resolved
Reduction gear on #2 end not functioning properly. Main propulsion machinery and auxiliary machinery directly connected to the engine must be at least equivalent to the standards established by ABS.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 March 2021
Resolved 4 May 2021
Resolution: Reduction gear rebuilt.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 June 2020 Resolved
Doors installed in class A fire boundaries, except those which are normally locked shall be of a self-closing type. Remove all hold-back devices and prove doors are self-closing. All doors shall remained closed "Not used" Re-qualify the explosion proof lights installed in the paint locker. Two globes do not properly seal and two protectors are broken/missing. Until re-qualified remove all material stored in the space posing a flammable hazard.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2020
Resolved 12 August 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2020 Resolved
Properly support the cable leading to the shore power cable box.
Action required: 10 - Deficiency Rectified
Resolved 30 July 2020
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 24 June 2020 Resolved
Complete PSTP MPVT section by the vessel's next annual inspection.
Action required: 705 - Other - as specified
Due 1 October 2021
Resolved 28 November 2021
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 24 June 2020 Resolved
Provide an updated CO2 service report. Administrative inconsistencies were noted during the spot check to include errors in transcription of the stamped weight vs. documented weight as well as omissions in visual inspection of flexable hoses found in question.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2020
Resolved 5 August 2020
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 24 June 2020 Resolved
Update the fire control plan to reflect the removal of the deep fat fryer, galley hood fire extinguisher, engineering fire suits, and lifebuoy arrangements.
Action required: 705 - Other - as specified
Due 30 October 2020
Resolved 14 July 2023
Resolution: Updated fire control plan reflected removal of deep fat fryer, galley hood fire extinguisher, engineering fire suits in Eng locker room, and lifebouy arrangements on pickle forks. All SAT.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 24 June 2020 Resolved
Remove all dead ended cables from watertight and fire boundary cable penetrations by next drydock.
Action required: 705 - Other - as specified
Due 31 October 2021
Resolved 9 February 2021
Resolution: NO deadend cables were observed
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 24 June 2020 Resolved
Prove the proper operations of the automatic draft indicating system. The master shall ensure draft readings are taken prior to each departure until the system is qualified.
Action required: 705 - Other - as specified
Resolved 14 August 2020
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 13 February 2019 Resolved
VESSEL MISSING MANY IMO LIFESAVING PLACARDS ON ALL DECKS. CONTAINERS, BRACKETS, RACKS, AND OTHER SIMILAR STOWAGE LOCATIONS FOR LIFESAVING EQUIPMENT MUST BE MARKED WITH SYMBOLS IN ACCORDANCE WITH IMO RESOLUTION A.760(18) INDICATING THE DEVICE STOWED IN THAT LOCATION. YOU MUST PROPERLY MARK THE LOCATIONS OF ALL LIFESAVING EQUIPMENT STOWED ABOARD THE VESSEL TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2019
Resolved 22 April 2019
Resolution: Photos of new placards received.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 13 February 2019 Resolved
VESSEL GENERAL ALARM BELL LOCATED ON THE WEATHER DECK IN WAY OF THE EMERGENCY GENERATOR COMPARTMENT NOT FUNCTIONING AS DESIGNED (NOT RINGING PROPERLY). EACH GENERAL EMERGENCY ALARM SIGNAL MUST BE CAPABLE OF PRODUCING A SIGNAL OR TONE DISTINCT FROM ANY OTHER AUDIBLE SIGNAL ON THE VESSEL AND NOT LESS THAN 80 dB(A). OVERHAUL OR RENEW DEVICE AND DEMONSTRATE PROPER FUNCTION TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 February 2019
Resolved 15 February 2019
Resolution: Repaired by WSF staff. MI witnessed operation.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 13 February 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Resolved 13 February 2019
Resolution: See Def
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 February 2019 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 10 - Deficiency Rectified
Resolved 13 February 2019
Resolution: See def
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 30 April 2018 Resolved
Automatic Draft Indicator not properly operating on the NO 1 and NO 2 END bridge. Vessel will take manual draft readings while loading until permanent repairs to bridge equipment can be made.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2018
Resolved 30 May 2018
Resolution: Vessel takes manual draft readings at each loading until automatic draft reading indicator is operable.
Fire Fighting › Structural - A Class Divisions › Service Spaces
Issued 31 October 2017 Resolved
3 inch penetration found in number 1 and number 2 ends in fan spaces below each wheelhouse. Repair to "A" Class boundery specifications to the satisfaction of the MI. 46 CFR 72.05-10(c)(1)
Action required: 705 - Other - as specified
Due 3 November 2017
Resolved 2 November 2017
Resolution: Welded plate over topside of penetrations
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 October 2017 Resolved
Nav Light Panel on # 1 end did not give audio alarm for light failure. Repair to the satisfaction of the MI. 46 CFR 111.75-17(b)
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 2 November 2017
Resolution: Reparied navigation light panel
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 20 October 2016 Resolved
Emergency generator overspeed was inoperative at the time of inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2016
Resolution: Received notification from Washington State Ferry port engineer that the Emergency generator overspeed component has been replace and tested. All Sat.
Engineering › Shafting/Propeller Arrangements › Propeller (controllable pitch)
Issued 20 October 2016 Resolved
#2 end controllable pitch propeller pitch indicator was found to be .2 degrees out of calibration in the push position.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 October 2016
Resolution: Received notification from Washington State Ferry port engineer that the #2 end controllable pitch propeller pitch indicator has been calibrated and is no longer .2 degrees off in the push position. All sat.
Electrical › Electric Generation Source (emergency) › Generator
Issued 4 November 2015 Resolved
Emergency generator did not properly trip when overspeed function tested. The emergency generator shall demonstrate an overspeed trip >110% <115% of normal RPM IAW 46 CFR
Condition: Invalid
Due 5 November 2015
Resolved 5 November 2015
Resolution: Corrected on site; overspeed trip was manually reset, all sat.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 4 November 2015 Resolved
Indicator bulb for No. 5 WTD on No. 2 end pilothouse inoperable. Panel shall properly show visual indication (open/close) for all WTDs IAW 46 CFR 170.270, ASTM F-1197.
Condition: Invalid
Due 5 November 2015
Resolved 5 November 2015
Resolution: Corrected on site, bulb replaced, all sat.
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 4 November 2015 Resolved
Draft limit control on #1 boiler inoperable. Repair IAW 46 CFR 61.35-3(a)(7).
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 December 2015
Resolved 24 November 2015
Resolution: Tested loss of draft shutdown/alarm on #1 boiler; all sat; cleared CG-835.
Engineering › Steering Gear System › Power Unit
Issued 4 November 2015 Resolved
An audible alarm must activate in the pilothouse upon failure of electric power to control system, failure of power to the power unit, and low oil level in the hydraulic reservoir IAW 46 CFR 58.25-25(d)(1)(2)(3).
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 November 2015
Resolved 5 November 2015
Resolution: Corrected on site.
Engineering › Steering Gear System › Motor
Issued 4 November 2015 Resolved
Each motor for the main/auxiliary steering gear must have a "mototr running" indicatro light in the pilot house. Indicatro lights inoperable IAW 46 CFR 58.25-25(f).
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 November 2015
Resolved 5 November 2015
Resolution: Corrected on site.
Engineering › Lubricating Oil Service System › Hose
Issued 4 November 2015 Resolved
Non-fire rated hoses for lube oil system found on #1 and #2 main engines. Hoses must be fire rated or protected by fire sleeve IAW 46 CFR 56.60-25(b).
Condition: Improper Installation
Due 5 December 2015
Resolved 24 November 2015
Resolution: Two improper lube oil hoses on the #1 and #2 MDEs were replaced with fire rated Aeroquip hoses; cleared CG-835.
Engineering › Steam Boiler (auxiliary/waste heat) › Piping
Issued 4 November 2015 Resolved
Non-metallic piping discovered on boiler #1, located between pumps and burner. All discharge piping from the fiel oil service pumps to burners must be metallic IAW 46 CFR 56.50-65.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 December 2015
Resolved 5 December 2015
Resolution: Hose located between boiler #1 pump and burner was replaced with schedule 80 piping.
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 4 November 2015 Resolved
Bolting on #2 boiler safety relief valve improperly bolted. Bolts and studs must extend completely through the nuts IAW 46 CFR 56.25-20(a)(2).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 December 2015
Resolved 24 November 2015
Resolution: The #2 Boiler relief valve was properly bolted; cleared CG-835.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 4 November 2015 Resolved
High jacket water temperature sensor on #1 Main Engine does not provide accurate temperature readings, thus preventing the high jacket water temperature alarm from sounding in the engine control room IAW 46 CFR 58.05-1.
Condition: Invalid
Action required: 705 - Other - as specified
Due 12 December 2015
Resolved 24 November 2015
Resolution: The jacket water sensor on the #1 MDE was replaced with a new sensor and tested for accuracy per the engineer's log entry dated 20 November 15; cleared CG-835.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 4 November 2015 Resolved
Fire dampers located at crew quarters supply #1 and #2 ends are inoperable. Repair IAW 46 CFR 78.47-33.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 December 2015
Resolved 24 November 2015
Resolution: The fire dampeners for the #1 and #2 crew's quarters supply ducts were tested sat; cleared CG-835.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 4 November 2015 Resolved
Numerous emergency lights were found with broken bulks or not properly labeled as an emergency light. Vessel shall conduct an inspection of all emergency lighting IAW 46 CFR 72.15-15.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 December 2015
Resolved 5 December 2015
Resolution: All emergency lighting is operational and properly labeled.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 9 October 2015 Resolved
Install proper insulation for A-60 boundary between the Engineer [name withheld] (EOS) overhead and the car deck.
Due 1 November 2016
Resolved 20 October 2016
Resolution: Port Engineer [name withheld] confirmed A-60 insulation was installed in EOS. Cleared def associated w/MISLE Activity #5752964 for A-60 boundary.
Fire Fighting › Structural - A Class Divisions › Control Stations
Issued 9 October 2015 Resolved
Install proper insulation for A-60 boundary between the Engineer [name withheld] (EOS) overhead and the car deck.
Due 1 November 2016
Resolved 20 October 2016
Resolution: A-60 insulation installed, inspected at COI.
Engineering › Generator (propulsion-electric) › Generator Excitation Circuitry
Issued 27 June 2012 Resolved
Vital generator's exciter was molten and shutdown the generator. Vessel is to ensure vital generator is properly functioning.
Action required: 705 - Other - as specified
Resolved 28 June 2012
Resolution: Vessel replaced alternator portion of vital generator. Vessel successfully tested and ran the generator online for 50 minutes with no problems.
Fire Fighting › Fire Hoses › Connections
Issued 31 January 2012 Resolved
Ensure hoses at firestations 19 and 21 are properly connected.
Due 1 February 2012
Resolved 1 February 2012
Resolution: Received call from Captain confirming that the hoses had been properly connected at the firestations.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 31 January 2012 Resolved
Paint fire damper lever red in galley.
Due 5 February 2012
Resolved 1 February 2012
Resolution: Received call from Captain confirming that the damper lever in the galley had been painted red.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 31 January 2012 Resolved
Ensure navigation lights are properly mounted on rescue boat #2.
Due 5 February 2012
Resolved 1 February 2012
Resolution: Received call from vessel Captain confirming that the navigation lights have been properly mounted on rescue boat #2.
Fire Fighting › Fire Main › Material
Issued 3 August 2011 Resolved
Ch. Engineer reported 1/4" hole on discharge side of #2 fire pump and a pin hold leak was found at FS #11. Make proper and permanent repairs to corroded/damaged sections of piping located on discharge side of FP and at FS#11.
Action required: 705 - Other - as specified
Due 30 September 2011
Resolved 5 October 2011
Resolution: Inspected three separate piping repairs on the fire main system and observed it maintaining pressure of 150 psi for over half an hour.
Fire Fighting › Fire Main › Condition
Issued 3 August 2011 Resolved
Provide test results of UT testing of full fire main system.
Action required: 705 - Other - as specified
Due 12 August 2011
Resolved 12 August 2011
Resolution: Gauging report provided to Sec. Puget Sound.
Fire Fighting › Fire Hydrants › Condition
Issued 3 August 2011 Resolved
Replace valve at F.S. #9
Due 6 August 2011
Resolved 7 August 2011
Resolution: Completed valve replacement.
Fire Fighting › Fire Main › Material
Issued 5 November 2010 Resolved
Replace fire pump discharge pipe on both pumps IAW 46CFR76.10.
Due 5 November 2010
Resolved 5 November 2010
Resolution: Inspected piping, ran pump, pressure held, no leaks. All sat.
Fire Fighting › Miscellaneous Items › B Class Division Penetrations
Issued 5 November 2010 Resolved
Replace fire dampers in all four deck locker spaces with appropriate marine-grade fire dampers IAW 46CFR76.15-35.
Due 5 February 2011
Resolved 28 January 2011
Resolution: New dampers properly installed in all four spaces.
Engineering › Steering Gear System › Interlock
Issued 20 October 2010 Resolved
Vessel's steering gear system not properly responding to the bridge control (possible bad potentiometer).
Action required: 705 - Other - as specified
Due 21 October 2010
Resolved 21 October 2010
Resolution: Found acknowledgement transfer button was in way of #2 end pilot house to be sticking and was short in travel (not properly latching). Corrected problem by disassembling the button, cleaned, reassembled and exercised. Operational test sat.
Fire Fighting › Water Fog Applicators › Condition
Issued 28 September 2010 Resolved
Various sprinkler heads on the vehicle deck were plugged, and not operating adequately.
Action required: 705 - Other - as specified
Due 28 September 2010
Resolved 28 September 2010
Resolution: All identified sprinkler heads were fixed on the spot.
Electrical › Lighting (service) › Lighting Feeder
Issued 28 September 2010 Resolved
Electrical wire for embarkation lighting had been pulled from adjacent junction box causing potential hazard.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 September 2010
Resolved 28 September 2010
Resolution: Vessel engineers fixed the deficiency on the spot.
Construction/Loadline › Penetrations › Weld
Issued 27 March 2009 Resolved
Replace the following spool pieces on #1 Engine room sea chest: 8 inch general service suction and 2 1/2 inch vent connection.
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 27 March 2009
Construction/Loadline › Penetrations › Weld
Issued 27 March 2009 Resolved
Replace the following spool piece on # 2 Engine room sea chest: 2 1/2 inch vent connection.
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 27 March 2009
Construction/Loadline › Hull › Bottom Plating
Issued 27 March 2009 Resolved
#2 Engine room, stbd side, crop & insert D strake, frame 9 to 14 1/2.
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 27 March 2009
Construction/Loadline › Hull › Bottom Plating
Issued 27 March 2009 Resolved
#1 Tank room, stbd side, crop & insert D strake, frame 43 to 47.
Action required: 705 - Other - as specified
Due 27 March 2009
Resolved 27 March 2009
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 9 October 2008 Resolved
Prove proper operation of all four car deck lifejacket drop bins. WSF CATHLAMET drop bin operational testing period of no less than 2 weeks will determine safe operation and necessary repairs to be made to correct deficiency.
Due 13 October 2009
Resolved 13 January 2009
Resolution: Conducted operational test of all four car deck lifejacket drop bins. All were satisfactory. Cleared outstanding CG-835.
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 2 October 2008 Resolved
Provide proper operation of vessels vehicle deck manual sprinkler system in zone B; three sprinkler heads were clogged, piping had to be replaced. In addition, several other sprinkler heads need to be cleaned or replaced throughout the main car deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 October 2008
Resolved 9 October 2008
Resolution: Tested sprinkler system, all sat.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 11 March 2008 Resolved
Noted chair with rollers was hitting circuit breakers/swithces of EOS electrical panel. Remove chair with rollers and/or install protection for the circuit breakers/switches for safety reason.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Electrical › Electrical Distribution System (service) › Switchboard
Issued 11 March 2008 Resolved
Install non conductive hand rail in way of electrical panel/switchboard.
Action required: 705 - Other - as specified
Resolved 16 April 2008
Fire Fighting › Ventilation Systems › Fans
Issued 11 March 2008 Resolved
Remove non approved fusible link installed on automatic fire damper of exhaust fan in way of # 1 & 2 Red Gear room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 16 April 2008
Construction/Loadline › Hull › Hull Plating
Issued 19 December 2007 Resolved
Noted pittings iwo of # 2 stbd Eng Rm bet Fr 6 to 14 of B strake and bet Fr 8 to 14 of C strake. Conduct U/T of area on next drydock period.
Action required: 705 - Other - as specified
Resolved 27 March 2009
Engineering › Bilge Water Management System › Strainer
Issued 19 December 2007 Resolved
Renew/replace bilge suction strainer iwo #1 end tank rm.
Action required: 705 - Other - as specified
Due 19 January 2008
Resolved 29 February 2008
Engineering › Bilge Water Management System › Strainer
Issued 19 December 2007 Resolved
Renew/replace bilge strainer iwo #2 MDE.
Action required: 705 - Other - as specified
Due 19 January 2008
Resolved 29 February 2008
Fire Fighting › Firemans Outfit › Axe
Issued 11 October 2007 Resolved
Axe on #1 end port side unlabeled. Axe on #2 end port side not there.
Due 11 November 2007
Resolved 29 January 2008
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 11 October 2007 Resolved
Muster lists on inside of car deck #1 end and 2 muster lists in engine room reflect galley members as part of the crew. Need replaced.
Due 11 November 2007
Resolved 29 January 2008
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 11 October 2007 Resolved
Fire Control Plan has errors; there is no fire door in pilot house. Need updated plan.
Due 11 October 2007
Resolved 29 January 2008
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 11 October 2007 Resolved
Smoke alarm #2 end in crew cabin inoperable.
Due 11 November 2007
Resolved 29 January 2008
Stability › Watertight Integrity › General
Issued 2 October 2007 Resolved
Crop out and renew sounding tube piping for #2 Void.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 October 2007
Resolved 15 October 2007
Resolution: Vessel engineer called and confirmed that sounding tube was cropped out and renewed.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 2 October 2007 Resolved
Vessel was missing 12 lifejackets.
Due 11 November 2007
Resolved 29 January 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 October 2007 Resolved
Vessel 'Not Under Command' light inoperable.
Due 11 October 2007
Resolved 29 January 2008
Fire Fighting › Ventilation Systems › Operating Controls
Issued 2 October 2006 Resolved
Fire dampeners unable to properly close.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 5 October 2006
Resolved 5 October 2006
Resolution: Witnessed satisfactory operation of fire dampener system.
Operations/Management › Drills/Instruction › Fire
Issued 29 June 2006 Resolved
Conduct another fire drill to the satisfaction of attending CG Marine Inspector
Action required: 705 - Other - as specified
Due 29 July 2006
Resolved 13 July 2006
Resolution: "B" watch crew conducted sat fire drill while on board KITTITAS.
Personnel › Training › Crisis Management/Human Behaviour
Issued 29 June 2006 Resolved
Conduct sat training of Engineering crew on vsl's ASP.
Action required: 705 - Other - as specified
Due 29 July 2006
Resolved 14 July 2006
Fire Fighting › Fire Main › Condition
Issued 29 June 2006 Resolved
Make permanent repair of a reported leak (temporarily repair with a soft patch iwo firemain pipe #2 end machinery space ladder.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 July 2006
Resolved 14 July 2006
Engineering › Steam Boiler (auxiliary/waste heat) › Automation Equipment
Issued 12 January 2005 Resolved
Auxiliary boilers blower motors #1 and #2, trips off line due to overload condition in breaker, when operating in high speed mode. Existing motors amperage draw is cause of the overload devices tripping. Replace motors to original specifications. Boilers will not be allowed to operate in high speed mode. Low speed mode is authorized to maintain service until proper repairs have been made.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 January 2005
Resolved 26 January 2005
Resolution: Replaced overload device in breaker from 1.3amp to 1.8amp. The 1.8 amp overload is still within the manufacturers specifications for the original breaker. Boiler operates in high and low.
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 25 October 2004 Resolved
Prove proper operation of the two installed AIS, both equipment failed to transmit signal for identification by other vessel.
Action required: 705 - Other - as specified
Due 25 November 2004
Resolved 12 January 2005
Resolution: AIS performed all functions properly.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System
Issued 13 August 2003 Resolved
Removed tapes on sprinkler heads found with tapes (installed to protect sprinkler heads for paint over spray). Conduct test of all zones of the sprinkler system. LEGACY COMPONENT DESC: Nozzles
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 15 August 2003
Resolution: Crew reported sat operational test of vessel''s sprinkler system.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 13 August 2003 Resolved
Properly display crew's licenses.
Action required: 705 - Other - as specified
Due 1 September 2004
Resolved 1 September 2004
Lifesaving › Lifejacket/PFD (General)
Issued 19 December 2002 Resolved
Vessel is to operate only with number of passengers as lifejackets are carried on board. LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 20 April 2003
Resolved 3 April 2003
Resolution: 835 requirement issued in error. Review of lifesaving requirements of COI yield adequate PFDs on board at time of COI inspection. 835 requirement is rescinded.
Lifesaving › Launching Appliances
Issued 19 November 2002 Resolved
When conversing will crewmembers, learned that the angle iron that holds the pulleys and shackles for the self-lowering cable on rescue boat #1 was bent and twisted on 18 Nov 02. It appears that cable tube locked, exerting excessive pressure on support bracket. Required crew to submit a CG-2692. LEGACY COMPONENT DESC: Davit
Action required: 705 - Other - as specified
Due 31 December 2002
Resolved 20 November 2002
Resolution: Received CG-2692.
Lifesaving › Launching Appliances
Issued 8 August 2002 Resolved
Renew releasing mechanism cable (falls) on #1 End Rescue Boat. LEGACY COMPONENT DESC: Release Mechanism
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 August 2002
Resolved 10 August 2002
Resolution: New cable installed
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 25 February 2002 Resolved
Rejected 8 adult lifejackets.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 February 2002
Resolved 25 February 2002
Resolution: replaced prior to completion of inspection.
Lifesaving
Issued 2 October 2001 Resolved
PROVIDE ANNUAL SERVICING FOR 3 45-PERSON VIKING LIFERAFTS AND THEIR HYDROSTATIC RELEASE UNITS.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Accommodation/Occupational Safety
Issued 2 October 2001 Resolved
ADJUST INBOARD PILOTHOUSE DOORS (FACING TOWARDS SMOKE STACKS, TEXAS DECK) TO ALLOW PROPER CLOSURE.
Condition: Unknown
Due 2 October 2001
Resolved 2 October 2001
Engineering
Issued 26 April 2001 Resolved
PRIOR TO PLACING VESSEL IN PASSENGER SERVICE TEST ALL REDUCTION GEAR ALARMSAND CONTROLS.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Engineering
Issued 26 April 2001 Resolved
PRIOR TO PLACING VESSEL IN PASSENGER SERVICE TEST ALL CPP SYSTEM ALARMS ANDCONTROLS.
Condition: Unknown
Due 12 June 2001
Resolved 12 June 2001
Engineering
Issued 28 September 2000 Resolved
VESSEL REQUESTED FIRESIDE/WATERSIDE EXAM AND HYDRO TEST OF ITS AUX BOILERS PAST ITS DUE DATE OF 28APR00. EXAM AND TEST WERE CONDUCTED BY ATTENDING CG INSPECTOR ON 28SEP00. EXAM AND TEST WERE SAT (SEE MINS OF THIS CASE).
Condition: Unknown
Due 5 October 2000
Resolved 20 October 2000
Lifesaving
Issued 22 April 1999 Resolved
FOUND FOUR LIFE RING BUOYS WHICH REQUIRED REPLACEMENT. EACH WAS SEVERLEY WEATHERED AND TORN.
Condition: Unknown
Due 22 April 1999
Resolved 11 May 1999
Fire Fighting
Issued 14 October 1998 Resolved
REPAIR AND PROVE PROPER OPERATION OF ROLL DOWN STEEL DOOR IN GALLEY SERVICELINE IN FRONT OF CASH REGISTER TO ENSURE CLASS "A" BOUNDARY IS EFFECTIVE AND DOOR CLOSES COMPLETELY.
Condition: Unknown
Due 14 October 1998
Resolved 14 October 1998
Accommodation/Occupational Safety
Issued 15 May 1997 Resolved
CLEAN/DEGREASE POPCORN POPPER IN GALLEY TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR NLT 23MAY97.
Condition: Unknown
Due 19 May 1997
Resolved 19 May 1997
Electrical
Issued 27 February 1997 Resolved
WIRES TO MISSING DEEP FAT FRYER NEED TO BE CLEANED OF GREASE AND THEN REMOVED OR PROPERLY TERMINATED INSIDE OF A BOX.
Condition: Unknown
Due 27 February 1997
Resolved 27 February 1997
Engineering
Issued 30 January 1996 Resolved
Replace plastic sightglass on main lube oil tank with glass sightglass.
Condition: Unknown
Due 30 January 1996
Resolved 30 January 1996
Electrical
Issued 30 January 1996 Resolved
Permanently repair junction box on stove receptacle & remove taped temporary repair
Condition: Unknown
Due 1 March 1996
Resolved 12 February 1996
Lifesaving
Issued 19 October 1995 Resolved
SECURE OIL DRUMS ON #1 END CAR DECK.
Condition: Unknown
Due 19 October 1995
Resolved 19 October 1995
Accommodation/Occupational Safety
Issued 19 October 1995 Resolved
CLEAN DUSTY AND DIRTY GALLEY VENTS.
Condition: Unknown
Due 19 October 1995
Resolved 19 October 1995
Fire Fighting
Issued 19 October 1995 Resolved
CONDUCTED ADDITIONAL TRAINING WITH FIRE CREW.
Condition: Unknown
Due 19 October 1995
Resolved 19 October 1995
Documentation
Issued 19 October 1995 Resolved
PROVIDE LICENSE FOR ELEVATOR.
Condition: Unknown
Due 19 October 1995
Resolved 19 October 1995
Navigation
Issued 18 July 1995 Resolved
REPLACE OR REPAIR FLUXGATE COMPASS.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Lifesaving
Issued 18 July 1995 Resolved
REMOVE ALL TYPE III LIFE JACKETS.
Condition: Unknown
Due 18 July 1995
Resolved 18 July 1995
Fire Fighting
Issued 7 February 1995 Resolved
HYDROSTATICALLY TEST ALL SCBA BOTTLES WHICH ARE CURRENTLY OVERDUE FOR FIVE YEAR REQUIRED TEST.
Condition: Unknown
Due 7 February 1995
Resolved 7 February 1995
Fire Fighting
Issued 7 February 1995 Resolved
REPLACE MISSING GENERAL ALARM PLACARD IN #1 END AT THE SOLARIUM WHICH SHOULD READ " WHEN BELL RINGS GO TO YOUR STATION".
Condition: Unknown
Due 7 February 1995
Resolved 7 February 1995
Electrical
Issued 7 February 1995 Resolved
REPLACE BURNED-OUT EMERGENCY LIGHTS AT BOTH PICKLE FORKS AND TEXAS DECK.
Condition: Unknown
Due 7 February 1995
Resolved 7 February 1995
Engineering
Issued 13 December 1994 Resolved
PROVIDE INDICATORS ON REMOTE F/O SHUTOFF VALVES FOR MACHINERY TO INDICATE POSITION.
Condition: Unknown
Due 13 December 1994
Resolved 13 December 1994
Fire Fighting
Issued 9 August 1994 Resolved
PROVIDE COPY OF ENG ROOM FIXED CO2 SYSTEM SERVICING REPORT TO INCLUDE CONDITION OF FLEX LOOPS AND IN PARTICULAR HOSES MARKED 9, 11, AND 18.
Condition: Unknown
Due 9 August 1994
Resolved 9 August 1994
Fire Fighting
Issued 19 July 1994 Resolved
Replace 2 rubber coated pressure hoses on Fixed CO2 system that are dry rotting and cracking. One hose is on a pilot bottle.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Navigation
Issued 19 July 1994 Resolved
Improper installation of radars in No. 1 and 2 ends IAW Subchapter H for Structural Fire Protection and Subchapter J for Electrical Installation requirements.
Condition: Unknown
Due 19 July 1994
Resolved 19 July 1994
Engineering
Issued 18 August 1993 Resolved
DEMONSTRATE PROPER OPERATION OF ALARMS AND SHUTDOWNS OF # 1 AND #2 AUX BOILERS.
Condition: Unknown
Due 18 August 1993
Resolved 18 August 1993
Documentation
Issued 24 May 1993 Resolved
PROVIDE STABILITY LETTER ISSUED BY G-MSC-1
Condition: Unknown
Due 24 May 1993
Resolved 24 May 1993
Electrical
Issued 11 June 1991 Resolved
MAKE PERMANENT REPAIRS TO WIRING OF REMOTE GOVENOR ACTUATOR ON NUMBER 2 SHIP SERVICE GENERATOR.
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991
Fire Fighting
Issued 28 November 1990 Resolved
AS PER 46CFR76.10-5(D), INSTALL A 125 PSI RELIEF VALVE ON THE DISCHARGE SIDE OF BOTH FIRE PUMPS. THIS REQUIREMENT IS BASED ON THE RESULTS OF A PITOT TUBE PRESSURE TEST CONDUCTED ON THE VESSEL KITTITAS.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVE COAST GUARD ACCEPTANCE OF NONARMORED OR [name withheld] IN PAINT LKR.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
INSTALL U.L. APPROVED EXPLOSION PROOF SEALING UNILET FOR DECK AND ENGINEERING PAINT LOCKER LIGHT FIXTURE. REF IEEE STD 45 43.4.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Deck/Cargo
Issued 10 April 1990 Resolved
MAKE REPAIRS AS REQUIRED, PROVE SATISFACTORY OPERATION, AND PROVIDE EVIDENCE OF A VALID ELEVATOR OPERATING CERTIFICATE.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Engineering
Issued 10 April 1990 Resolved
PROVIDE AND INSTALL REMOTE FUEL OIL SHUT OFF VALVE FOR #1 FUEL OIL SERVICE TANK.
Condition: Unknown
Due 10 April 1990
Resolved 10 April 1990
Fire Fighting
Issued 3 October 1989 Resolved
PROVIDE FUEL FOR FLAME SAFETY LAMP.
Condition: Unknown
Due 3 October 1989
Resolved 3 October 1989
Fire Fighting
Issued 3 October 1989 Resolved
PROVIDE PROOF OF SERVICING FOR SEMI-PORTABLE CO2 BOTTLE LOCATED IN ENGINE ROOM #1.
Condition: Unknown
Due 3 October 1989
Resolved 3 October 1989
Engineering
Issued 3 October 1989 Resolved
RE-INSTALL #1 BOILER SAFETY VALVE SPRING COVERS.
Condition: Unknown
Due 3 October 1989
Resolved 3 October 1989
Lifesaving
Issued 3 October 1989 Resolved
STENCIL EMERGENCY ESCAPE IN #1 SEWAGE TANK ROOM
Condition: Unknown
Due 3 October 1989
Resolved 3 October 1989
Lifesaving
Issued 4 August 1989 Resolved
PROVE PROPER OPERATION OF RESCUE BOAT EMBARKATION ARRANGEMENT FROM #1 & #2 RESCUE BOATS. THE ABOVE ITEMS TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR NO LATER THAN 11 AUG 89.
Condition: Unknown
Due 4 August 1989
Resolved 4 August 1989
Electrical
Issued 25 April 1989 Resolved
INSTALL CABLE SEAL FITTINGS IN ENGINEERS & DECK PAINT LOCKER TO MAKE EXPLOSION PROOF. REF:MSM VOL 4 3C2(8). REPAIRS SHALL BE MADE TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 25 April 1989
Resolved 25 April 1989
Engineering
Issued 16 March 1989 Resolved
HAVE THE VESSEL'S UNFIRED PRESSURE VESSEL OPEN AND READY FOR EXAMINATION AND TESTING TO THE SATISFACTION OF THE ATTENDING COGNIZANT [name withheld] THIS ITEM TO BE ACCOMPLISHED BY 30 APRIL 1989.
Condition: Unknown
Due 16 March 1989
Resolved 16 March 1989
Fire Fighting
Issued 29 April 1988 Resolved
INSTALL A RELIEF VALVE IN EACH FIRE PUMP DISCHARGE TO MEET THE REQUIREMENTSOF 46 CFR 76.10-5(C) & (D). THE ABOVE TO BE ACCOMPLISHED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 29 April 1988
Resolved 29 April 1988
Unknown
Issued 5 January 1988 Resolved
INSTALL KEYS AND BOXES TO PROVIDE EMERGENCY ACCESS TO THE EMERGENCY GENERATOR ROOM, (B & C) FAN ROOMS AND THE ELEVATOR SHAFT.
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Electrical
Issued 14 October 1987 Resolved
REPLACE LIGHT GLOBE GUARDS (2) IN DISTRIBUTION PANEL ROOM
Condition: Unknown
Due 14 October 1987
Resolved 14 October 1987
Fire Fighting
Issued 14 October 1987 Resolved
CLEAN AND MAINTAIN THE PATH TO THE FIRE DAMPERS IN THE DECK STORE ROOMS ON THE CAR DECK (FIRE DAMPERS FOR NO.1 & 2 RED GEAR ROOMS). ITEM TO BE ACCOMPLISHED PRIOR TO THE CARRIAGE OF PEOPLE FOR HIRE.
Condition: Unknown
Due 14 October 1987
Resolved 14 October 1987
Unknown
Issued 14 October 1987 Resolved
REPLACE MISSING KEYS ON MAIN DECK OUTSIDE DECK STOWAGE ROOMS( FIRE DAMPERS INSIDE) AND DISTRIBUTION PANEL ROOM
Condition: Unknown
Due 14 October 1987
Resolved 14 October 1987
Fire Fighting
Issued 14 October 1987 Resolved
CLEAN AND MAINTAIN PATH TO FIRE DAMPER IN ELECTRICAL DISTRIBUTION PANEL ROOM ON CAR DECK (CHAIRS IN ROOM WERE BLOCKING DOOR FROM OPENING AND PATH TO FIRE DAMPER). ITEM TO BE ACCOMPLISHED PRIOR TO THE CARRIAGE OF PEOPLE FOR HIRE.
Condition: Unknown
Due 14 October 1987
Resolved 14 October 1987
Lifesaving
Issued 5 April 1987 Resolved
CONDUCT EMERGENCY DRILLS WITH FULL CREW IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 5 April 1987
Resolved 5 April 1987
Fire Fighting
Issued 5 April 1987 Resolved
REPLACE EXISTING GLASS WITH WIRE-INSERTED GLASS ON FIRE DOORS LEADING TO RESCUE BOAT PLATFORMS PER 46 CFR 72.05-25(B).
Condition: Unknown
Due 5 April 1987
Resolved 5 April 1987
Construction/Loadline
Issued 5 April 1987 Resolved
REPAIR UNAPPROVED BULKHEAD PENETRATIONS IN ALL WATERTIGHT BULKHEADS EXCLUDING COLLISION BULKHEAD WITH APPROVED PENETRATIONS PER REGULATIONS. COLLISION BULKHEAD REPAIRED PRIOR TO ISSUANCE OF CERTIFICATE.
Condition: Unknown
Due 5 April 1987
Resolved 5 April 1987
Fire Fighting
Issued 5 April 1987 Resolved
REPAIR OR REPLACE ALL FIRE SCREEN DOORS ON PASSENGER DECK AND IN STAIRWAYS TO PASSENGER DECK REQUIRING INSTALLATION OF INSULATION IN UPPER 6" TO 8" OFDOOR TO MEET REQUIREMENTS FOR FIRE DOORS.
Condition: Unknown
Due 5 April 1987
Resolved 5 April 1987
Fire Fighting
Issued 5 April 1987 Resolved
INSULATE MVZ BULKHEADS AND ALL OTHER A-15 AND A-30 BULKHEADS ON PASSENGER DECK IN WAY OF GALLEY AREA TO AGREE WITH CG APPROVED DRWG.
Condition: Unknown
Due 5 April 1987
Resolved 5 April 1987
Lifesaving
Issued 4 February 1987 Resolved
PROVIDE BOAT HOOK FOR ALL RESCUE BOATS
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Lifesaving
Issued 4 February 1987 Resolved
PROVIDE HYDRO RELEASES THAT COMPLY WITH 46CFR 160.062-5 FOR ALL RAFTS.
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Documentation
Issued 4 February 1987 Resolved
PROVIDE CURRENT ELEVATOR CERTIFICATE PRIOR TO USING ELEVATOR
Condition: Unknown
Due 4 February 1987
Resolved 4 February 1987
Engineering
Issued 26 September 1986 Resolved
1. FOR THE PERIOD 26SEP86 TO 06OCT86 OPERATE IN ENGINEROOM CONTROL TO MAKEALL LANDINGS/DEPARTURES. MAKE REPORT OF ALL PITCH CONTROL OPERATION DISCREPENCIES TO [name withheld] NOT LATER THAN 06OCT86.
Condition: Unknown
Due 26 September 1986
Resolved 26 September 1986
Engineering
Issued 14 September 1986 Resolved
2. MAKE REPORT OF ALL PITCH CONTROL OPERATION DISCREPENCIES TO [name withheld] NOT LATER THAN 22SEP86.
Condition: Unknown
Due 14 September 1986
Resolved 14 September 1986
Engineering
Issued 14 September 1986 Resolved
1. FOR THE PERIOD 14SEP86 TO 22SEP86 OPERATE IN ENGINE ROOM CONTROL TO MAKE ALL LANDINGS/DEPARTURES.
Condition: Unknown
Due 14 September 1986
Resolved 14 September 1986
Lifesaving
Issued 18 July 1986 Resolved
REPAIR GATE HINGE AT LIFERAFT STATION #1 AND PROPERLY SECURE CABLE TO EMBARCATION LIGHT.
Condition: Unknown
Due 18 July 1986
Resolved 18 July 1986
Accommodation/Occupational Safety
Issued 18 July 1986 Resolved
SECURE ALL LOOSE VIDEO GAMES (03) AND LARGE NEWSPAPER MACHINES ON PASSENGERDECK.
Condition: Unknown
Due 18 July 1986
Resolved 18 July 1986
Accommodation/Occupational Safety
Issued 18 July 1986 Resolved
INSTALL SECURING DEVICES FOR SIX FOOD DRAWERS UNDER GALLEY STOVE.
Condition: Unknown
Due 18 July 1986
Resolved 18 July 1986
Lifesaving
Issued 28 April 1986 Resolved
CONDUCT A FIRE AND BOAT DRILL WITH THE VESSEL'S REGULAR CREW AS PER 46CFR78.17-50. THIS IS TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR NO LATER THAN 9MAY86.(835 ISSUED BY [name withheld])
Condition: Unknown
Due 28 April 1986
Resolved 28 April 1986
Electrical
Issued 13 August 1985 Resolved
VESSEL'S PA SYSTEM INOPERATIVE THROUGHOUT THE SHIP. THIS DEFICIENCY WAS TO HAVE BEEN CORRECTED BY 16 AUGUST 1985.
Condition: Unknown
Due 13 August 1985
Resolved 13 August 1985
Accommodation/Occupational Safety
Issued 13 August 1985 Resolved
DEMONSTRATE PROPER OPERATION OF MARINE SANITATION DEVICE.
Condition: Unknown
Due 13 August 1985
Resolved 13 August 1985
Electrical
Issued 13 August 1985 Resolved
DEMONSTRATE OVERSPEED OPERATION OF #1 S/S GENERATOR.
Condition: Unknown
Due 13 August 1985
Resolved 13 August 1985
Lifesaving
Issued 14 May 1985 Resolved
CONDUCT BOAT DRILL. THIS ITEM WAS TO HAVE BEEN COMPLETED BY 22 MAY 1985.
Condition: Unknown
Due 14 May 1985
Resolved 14 May 1985
Accommodation/Occupational Safety
Issued 14 May 1985 Resolved
DEMONSTRATE PROPER OPERATION OF TYPE II MARINE SANITATION DEVICE. THIS ITEM WAS TO HAVE BEEN COMPLETED BY 1 JULY 1985.
Condition: Unknown
Due 14 May 1985
Resolved 14 May 1985
Fire Fighting
Issued 14 May 1985 Resolved
CONDUCT FIRE DRILL. THIS ITEM WAS TO HAVE BEEN COMPLETED BY 22 MAY 1985.
Condition: Unknown
Due 14 May 1985
Resolved 14 May 1985

Casualty record · 42

9 November 2003Routine · role: Involved in a Marine Casualty · activity 1949563
20 June 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2105859
9 March 2006Routine · role: Involved in a Marine Casualty · activity 2603149
29 June 2006Routine · role: Involved in a Marine Casualty · activity 2711545
22 September 2006Routine · role: Involved in a Marine Casualty · activity 2806397
1 June 2007Major Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 2953608
8 June 2007Routine · role: Involved in a Marine Casualty · activity 3012025
4 July 2007Routine · role: Involved in a Marine Casualty · activity 2989702
17 January 2008Routine · role: Involved in a Marine Casualty · activity 3135517
30 June 2008Routine · role: Involved in a Marine Casualty · 1 injured · activity 3269712
5 July 2008Routine · role: Involved in a Marine Casualty · activity 3262546
24 September 2008Routine · role: Involved in a Marine Casualty · activity 3339545
15 December 2008Routine · role: Involved in a Marine Casualty · activity 3384162
30 April 2009Routine · role: Involved in a Marine Casualty · activity 3467212
4 June 2009Routine · role: Involved in a Marine Casualty · activity 3512748
24 December 2009Routine · role: Involved in a Marine Casualty · activity 3660604
23 March 2010Routine · role: Involved in a Marine Casualty · activity 3704783
29 July 2010Routine · role: Involved in a Marine Casualty · activity 3810563
25 August 2010Routine · role: Involved in a Marine Casualty · activity 3838031
24 November 2010Routine · role: Involved in a Marine Casualty · activity 3900729
15 February 2011Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3951676
3 August 2011Routine · role: Involved in a Marine Casualty · activity 4104298
8 September 2011Routine · role: Involved in a Marine Casualty · activity 4139363
19 October 2011Routine · role: Involved in a Marine Casualty · activity 4172336
20 January 2012Routine · role: Involved in a Marine Casualty · activity 4233271
5 March 2012Routine · role: Involved in a Marine Casualty · activity 4286237
27 June 2012Routine · role: Involved in a Marine Casualty · activity 4358302
27 August 2012Routine · role: Involved in a Marine Casualty · activity 4434116
23 October 2012Routine · role: Involved in a Marine Casualty · activity 4471347
3 May 2013Routine · role: Involved in a Marine Casualty · activity 4584789
7 August 2013Routine · role: Involved in a Marine Casualty · activity 4686861
18 December 2013Routine · role: Involved in a Marine Casualty · activity 4771238
13 January 2014Routine · role: Involved in a Marine Casualty · activity 4784476
21 May 2015Routine · role: Involved in a Marine Casualty · activity 5131147
15 August 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6533395
9 July 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7272766
24 July 2021Routine · role: Involved in a Marine Casualty · activity 7267125
1 October 2021Routine · role: Involved in a Marine Casualty · activity 7335682
3 April 2023Routine · role: Involved in a Marine Casualty · activity 7681301
25 August 2025Routine · role: Involved in a Marine Casualty · activity 8259407
17 March 2026Routine · role: Involved in a Marine Casualty · activity 8341556
19 May 2026Routine · role: Involved in a Marine Casualty · activity 8401247
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.