← All vessels
EMERALD
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named EMERALD
EMERALD is a 1981 passenger vessel (inspected). The Coast Guard has recorded 59 inspections since 1982, most recently in July 2026, along with 130 deficiencies, 2 operational controls and 4 casualty investigations between 2017 and 2024.
Records from 1982 to 2026. Most recent: inspection, 13 July 2026.
- Built
- 1981
- Last inspected
- 13 July 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 130 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 4 investigations · 2017–2024
Identity
643535
WDD3763
53367
Flag
UNITED STATES
367135920
Maury page id
psix-53367
Inspections, by type
…with no type recorded11
Years with a record
29 calendar years (1982–2026)
The 59 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)40.1 ft × 13.6 ft × 6.8 ft
Registered tonnagegross 19 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL BOAT WORKS · MEDLEY, FL, UNITED STATES · built 1981
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portJUPITER, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 12 August 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Simplified, Gross Ton
17 - Simplified, Net Ton
17 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDD3763MMSI 367135920 · active · compulsorily equipped · granted 9 June 2016, expires 22 August 2026
WCX2554MMSI not assigned · expired · compulsorily equipped · granted 5 February 1997, cancelled 7 April 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 59
13 July 2026
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8437319
6 June 2026
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 8401086
15 April 2026
Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8418565
25 September 2025
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8241272
13 November 2024
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8034842
16 October 2024
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8020178
1 May 2024
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7932055
4 February 2024
Administrative Inspection · DAPI Audit · Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7860367
2 February 2024
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7861205
8 November 2023
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7806702
7 December 2022
Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7605415
17 August 2022
Administrative Inspection · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7535969
10 August 2021
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7282252
5 November 2020
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7090326
20 August 2020
Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7037975
9 May 2020
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7062996
1 November 2019
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6863194
8 October 2019
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6830637
16 October 2018
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6562491
22 May 2018
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6420512
21 June 2017
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 6183494
14 June 2017
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6175893
27 March 2017
Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6112288
23 January 2017
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6075266
23 January 2017
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6119886
19 October 2016
Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6025431
28 June 2016
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5922661
6 October 2014
Drydock Exam · Administrative Inspection · In-Service Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4999669
17 June 2014
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4893012
25 June 2012
Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4356341
12 June 2012
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4342941
4 January 2012
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 4218443
8 July 2011
Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4077849
6 October 2010
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3864227
6 January 2009
Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 3389706
29 October 2008
Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3353822
29 February 2008
Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3155946
3 December 2007
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3108563
16 November 2004
Administrative Inspection · Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2241820
8 July 2004
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2126271
19 February 2004
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2005366
22 July 2003
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1825384
17 July 2002
Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1632495
26 April 2002
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1495523
12 September 2001
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1072430
9 May 2001
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1063826
24 August 2000
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1054105
27 July 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1052883
25 April 2000
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 818242
24 April 2000
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1427826
24 June 1999
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1434907
10 September 1998
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 800758
30 June 1998
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 792909
30 April 1998
COI Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1449066
17 September 1997
Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1110797
18 August 1997
Inclining Experiment
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 784276
17 July 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296347
18 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272876
14 March 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277705
Deficiency record · 130
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 25 September 2025
Resolved
Each life float must be fitted with a light. Light is inoperable.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 September 2025
Resolved
On a vessel of at least 26 feet, a visual and audible alarm must be provided at the operating station. Visual for E/R high water alarm is inoperable.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 September 2025
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. E/R bilge pump indicator is inoperable.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 25 September 2025
Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test. Provided proof on enrollment for crewmember in question.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 25 September 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions. Instructions are not up-to-date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 September 2025
Resolved
Remote fuel shutoff station must be marked in clear legible letters at least 1 inch high. Marking is only about 1/2 inch in hight.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 25 September 2025
Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Owner's medical certificate is expired. Cannot engage in a position that requires an MMC.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 13 November 2024
Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. Station License missing. Vessel restricted to not more than 1000 feet from shore.
47 CFR 80.13
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 November 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot [name withheld] List, Tide tables, Current Tables. Extracts from the publications may be provided. Publications outdated or missing.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 November 2024
Resolved
A vessel must carry either a first-aid kit approved under 160.041 or a kit with equivalent content. Content expired or missing. Burn gel, ointment, ammonia inhalant etc.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2024
Resolved
The discharge ends of fuel tank vents must be fitted with removable flame screen or flame arresters. The screen must consist of a single corrosion resistant wire of at least 30x30 mesh. Screen missing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 November 2024
Resolved
On a vessel of at least 26', a visual and audible alarm must be provided at the operating station. E/R visual indicator inoperable.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 November 2024
Resolved
Monthly inspection required by NFPA 10 May be conducted by owner, operator, or person-in-charge. No evidence of monthly checks being conducted. Corrected on the spot
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 4 February 2024
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Marine employer failed to produce evidence of a satisfactory drug and alcohol program/policy, marine employer failed to direct required drug testing with in time requirements due to a SMI. Marine employer failed to produce a current roster of employees enrolled in the required alcohol and drug testing program. Vessel was found operating, with paying passengers onboard without a credentialed master onboard. Vessel is restricted from carrying passengers until;
1. Marine employer can produce satisfactory evidence of a satisfactory drug and alcohol program.
2. Marine employer can produce a current roster of employees enrolled in the drug testing program.
3. Vessel receives a satisfactory additional in-service inspection by an attending CG marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 November 2023
Resolved
A vessel on which a pre-engineered system is installed must have the following: A means to reset devices used to automatically shut down engines.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 November 2023
Resolved
The owner or a qualified servicing facility as applicable must conduct the following inspections and tests: Portable extinguishers must be inspected and maintained IAW NFPA 10. Extinguishers and fixed firefighting system have not been serviced in over a year.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 November 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts, U.S. Coast Guard Coast Pilot, Tides tables, and Currents tables. Pubs not up-to-date.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 November 2023
Resolved
A vessel must carry either a first-aid kit approved under 160.041 or a kit with equivalent contents. Vessel missing aspirin.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 7 December 2022
Resolved
EPIRB hydrostatic release unit is expired. Replace HRU. Operations restricted to no more than 3 miles from shore.
46 CFR 185.740
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 7 December 2022
Resolved
10-B:C portable fire extinguisher not provided. Provide and mount 10-B:C fire extinguisher at operating station.
46 CFR 185.510
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 7 December 2022
Resolved
Emergency instruction not posted. Post emergency instructions at operating station. 46 CFR 185.510
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 December 2022
Resolved
COI not posted. Post COI in an area to allow passengers to view. 46 CFR 176.302
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 December 2022
Resolved
Any vessel over 12 meters in length is required to have a masthead light. Vessel has an all around anchor light but not a separate masthead light as required. 46 CFR 183.420
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 October 2022
Resolved
Numerous voids found in the hull's laminate both port and starboard side. Marked areas to be repaired prior to credit dry-dock. 46 CFR 176.610
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 12 October 2022
Resolved
MSD disharge through hull valve doesn't completly close. Valve to be repaired/replaced prior to credit dry-dock.
46 CFR 179.360
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 12 October 2022
Resolved
Ladders into machinery space and into v-berth are loose. Secure ladders prior to credit dry-dock. 46 CFR 176.610
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2022
Resolved
Batteries are not secure and not protected from water splash. Batteries to be secured and covered prior to credit dry-dock. 46 CFR 183.350
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 8 September 2021
Resolved
EPIRB registration expired. Provide current registration for vessel's EPIRB. Route restricted to no more than 3 miles from shore. 46 CFR 185.728
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 September 2021
Resolved
Machinery space high level visual alarm inoperable. Repair alarm to the satisfaction of marine inspector.
46 CFR 182.530
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 September 2021
Resolved
Lazerette bilge high level visual alarm inoperable. Repair alarm to the satisfaction of marine inspector.
46 CFR 182.530
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 September 2021
Resolved
Fuel tank space automatic electrical submersible pump and alarm inoperable. Repair pump and alarm to the satisfaction of marine inspector. 46 CFR 182.530
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 19 November 2020
Resolved
Drug and alcohol program employee list is expired. Provide current employee list. 46 CFR 16.230
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 November 2020
Resolved
Life ring is in non-serviceable condition. Provide serviceable life ring. 46 CFR 180.70
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 November 2020
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 November 2020
Resolved
Radio-telephony Safety Certificate not on board.. Provide Safety Certificate. Passenger operations restricted to no more than 1000 feet from shore. 46 CFR 80.401
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 November 2020
Resolved
Lazerette bilge high water alarm assembly is in non-serviceable condition. Replace alarm assembly.
46 CFR 182.530
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 19 November 2020
Resolved
Alcohol testing strips expired. Provide current alcohol testing strips or equivalent. 46 CFR 4.06-3
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 November 2020
Resolved
Operating station fire extinguisher is located in a cabinet and not labeled. Label location of fire extinguisher.
46 CFR 181.520
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 November 2020
Resolved
Emergency fuel shut-off valve label is unreadable. Re-label emergency fuel shut-off valve location in a way that prevents the label from being easily removed. 46 CFR 185.608
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 November 2020
Resolved
Life jacket donning placard does not show the donning procedures for the same type of jacket provided onboard. Provide proper donning placard for type of life jacket onboard. 46 CFR 185.516
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 November 2020
Resolved
Navigation light configuration is not in accordance with navigation rules. Masthead light and stern light to be arranged as separate lights with proper arc of visibility. Current configuration has masthead and stern light as an all around white light. 46 CFR 183.420
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 October 2020
Resolved
Installed pre-engineered fire extinguishing system annual inspection is overdue. Provide report of satisfactory fire fighting equipment inspection/servicing prior to operating with passengers. 46 CFR 176.810(b)(1)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 October 2020
Resolved
Emergency fuel shut off valve at tank does not close properly. Installed valve is a 45 degree actuating valve but the valve turns past 45 degrees. Valve to be repaired or replaced to ensure valve closes as designed prior to credit dry-dock.
46 CFR 182.455(b)(4)
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 October 2020
Resolved
Numerous areas of hull have blisters or damage to the fiberglass. Make repairs to the satisfaction of marine inspector. 46 CFR 176.610
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2020
Resolved
Propeller found loose on shaft. Remove propeller to allow for a visual examination of the shaft, shaft key-way and shaft to propeller key prior to credit dry-dock.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 7 October 2020
Resolved
Forward bulkhead in machinery space is cracked and de-laminated. Make repairs prior to credit dry-dock.
46 CFR 176.610
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 7 October 2020
Resolved
Fiberglass tabs at corners of the forward compartment are de-laminated. Make repairs prior to credit dry-dock.
46 CFR 176.610
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 7 October 2020
Resolved
Overhead hand rails below operating station loose. Secure hand rails to topside deck prior to credit dry-dock.
46 CFR 177.900
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 7 October 2020
Resolved
Forward main deck found to be soft with water intrusion. Provide repair proposal to marine inspector.
46 CFR 176.610
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 7 October 2020
Resolved
Top deck/operating station deck found to be soft possibly requiring extra support. Provide repair proposal to marine inspector. 46 CFR 176.610
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 29 October 2019
Resolved
Repair/replace bilge high level alarms for engine room and mid-void space prior to carrying passengers. 46 CFR 182.530
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 October 2019
Resolved
Breaker panel has no box to cover the back of the breakers and wiring to breakers. Panel also has open spaces that need to be closed off. Panel to be made totally enclosed prior to carrying passengers. 46 CFR 183.330(b)
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 October 2019
Resolved
Navigation lights inoperative. Repair lights prior to operations. 46 CFR 420
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 October 2019
Resolved
4 adult life jackets non-serviceable. Total adult persons count reduced to 16. 46 CFR 180.71
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 29 October 2019
Resolved
Fuel tank space watertight hatch has broken hardware and does not fully close and seal. Repair hatch to make watertight.
46 CFR 179.360
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 October 2019
Resolved
Install metallic flame shield on secondary fuel filter bowl.
46 CFR 182.4558
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019
Resolved
Install permanent type connectors at battery cable to terminal connections. 46 CFR 183.350
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 October 2019
Resolved
Post life jacket donning placards for both type of life jackets onboard. 46 CFR 185.516
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 29 October 2019
Resolved
Move emergency instructions to make fully visible to passengers and crew. 46 CFR 185.510
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 29 October 2019
Resolved
8 distress signals to expire in 2 days. Replace 8 distress signals with current signals. 46 CFR 180.68
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 29 October 2019
Resolved
Post Certificate of Inspection and Stability letter.
46 CFR 176.302
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 22 May 2018
Resolved
Place name on both sides of the bow in 4 inch letters.
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 22 May 2018
Resolved
Submit repair plan for cracks in deck.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 June 2017
Resolved
Provide current COD.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 June 2017
Resolved
Prove proper operation of bilge alarm light for fwd compt.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 June 2017
Resolved
Update expired items in first aid kit.
Lifesaving › Lifebuoys › Serviceable
Issued 15 June 2017
Resolved
Renew line around ring buoy or replace ring buoy.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 June 2017
Resolved
Provide 3 more type I adult PFD's, vessel restricted to 17 adults until 3 more are added.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 15 June 2017
Resolved
Address all drug and alcohol program defs as discussed by the CGMI.
Fire Fighting › Structural Fire Protection - General › Fiber Reinforced Plastic
Issued 15 June 2017
Resolved
Make aft engine room bulkhead watertight.
Documentation › Certificates/Documents › FCC SSL
Issued 15 June 2017
Resolved
Provide copy of FCC SSL.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 23 January 2017
Resolved
Vessel was operating with 14 passengers and did not maintain proper manning, the Captain dove also just leaving the deckhand onboard. (the deckhand is a licensed Captain also).
Engineering › Reduction Gearing/Clutches › Oil Spray
Issued 23 January 2017
Resolved
Prove proper operation of the reduction gear.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 19 October 2016
Resolved
Replace hose on Shaft log.
Construction/Loadline › Hull › Weld
Issued 19 October 2016
Resolved
Repair cracked weld on dive boarding ladder.
Lifesaving › Lifefloat › Serviceable
Issued 28 June 2016
Resolved
Replace lifefloat.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 28 June 2016
Resolved
Provide 2 additional approved flares.
Communications › Radio Communications › VHF Radiotelephone
Issued 28 June 2016
Resolved
Prove proper operation of VHF-FM radio.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 28 June 2016
Resolved
Provide log book to document emergency drills and epirb checks more consistently.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 28 June 2016
Resolved
Provide CG light list.
Communications › Alarms/Indicators › High Water Alarm
Issued 28 June 2016
Resolved
Label hight water alarms.
Stability › Watertight Integrity › General
Issued 28 June 2016
Resolved
Prove proper operation of lazerette deck hatch.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 28 June 2016
Resolved
Seal penetration in fwd engine room bulkhead.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 June 2016
Resolved
Remove deadend wiring in engine room as dicussed with CGMI.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 28 June 2016
Resolved
Provide 7 more type I lifejackets.
Stability › Watertight Integrity › General
Issued 28 June 2016
Resolved
Install securing device on engine room deck hatch.
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 June 2012
Resolved
Bilge Alarm - Unknown Cause/Condition
Lifesaving › Lifebuoys › Approval
Issued 12 June 2012
Resolved
Properly install type II retro-reflective tape on life-ring.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 June 2012
Resolved
Provide approved first aid kit.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 12 June 2012
Resolved
Provide current charts and pubs.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 12 June 2012
Resolved
Show proof of current employee coverage list.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 12 June 2012
Resolved
Show proof of MIS submission for 2011
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 12 June 2012
Resolved
Provide EAP contact numbers for display.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 3 December 2007
Resolved
Provide Certificate of Documentation.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 December 2007
Resolved
Provide original Certificate of Inspection onboard the vessel.
Documentation › Certificates/Documents › Stability Letter
Issued 29 July 2004
Resolved
Post Stability letter IAW 46 CFR 176.306
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 8 July 2004
Resolved
Provide waterlight rope for life float.
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 July 2004
Resolved
Replace broken emergency fuel shutoff handle. IAW 182.455
Engineering › Steering Gear System › Rudder Bearing
Issued 8 July 2004
Resolved
Repair leaking rudder bearing.
Documentation › Certificates/Documents › FCC SSL
Issued 22 July 2003
Resolved
Provide current FCC Safety Certificate IAW 47 CFR 80.401. LEGACY COMPONENT DESC: FCC Safety Certificate
Personnel › Manning/Qualifications › First Aid Certified Personnel
Issued 22 July 2003
Resolved
Provide CPR/First Aid cards for 50 % of crew IAW NVIC 1-91. LEGACY COMPONENT DESC: CPR Certified Personnel
Stability › Weathertight Integrity › General
Issued 22 July 2003
Resolved
Repair and/or replace weathertight hatch on the bow.
Communications › Alarms/Indicators
Issued 22 July 2003
Resolved
Repair and/or replace high level bilge switch in the lazarrette. LEGACY COMPONENT DESC: Bilge Alarm
Engineering › Fuel Oil Service System
Issued 16 July 2002
Resolved
Repair/replace leaking fuel line at main diesel engine connection and conduct engine test. LEGACY COMPONENT DESC: Piping
Engineering › Bilge Water Management System
Issued 16 July 2002
Resolved
Repair all bilge alarms. LEGACY COMPONENT DESC: ALARMS
Construction/Loadline › Hull
Issued 24 April 2002
Resolved
Make repairs to stem area portside, IAW NVIC 8-87. Cracked gel coat. LEGACY COMPONENT DESC: Hull Plating
Construction/Loadline › Hull › Side Shell
Issued 24 April 2002
Resolved
Make repairs to FOSCLE in way of Anchor Housing. IAW NVIC 8-87.
Construction/Loadline › Penetrations › Gasket
Issued 24 April 2002
Resolved
Make repairs to BOMAR Hatch on stern leading to Fuel Tanks. Flanges leak.
Engineering › Fuel Oil Storage/Transfer System
Issued 24 April 2002
Resolved
Repair replace fuel line connections on top of fuel tank. LEGACY COMPONENT DESC: Piping
Construction/Loadline › Hull
Issued 24 April 2002
Resolved
Tighten Bow Railing. Rails are loose. LEGACY COMPONENT DESC: Railings
Electrical › Electric Supply System (service) › Cable
Issued 24 April 2002
Resolved
Replace electrical outlet in fuel tank space.
Navigation
Issued 9 May 2001
Resolved
PROVIDE UP TO DATE CHARTS AND PUBLICATION AS REQUIRED BY 46 CFR 184.420
Lifesaving
Issued 9 May 2001
Resolved
PROVIDE PUBLIC ADDRESS SYSTEM AS REQUIRED BY 46 CFR 184.610
Accommodation/Occupational Safety
Issued 9 May 2001
Resolved
PROVIDE RAIL COURSES FOR BOW PULPIT AS REQUIRED BY 46 CFR 177.900
Documentation
Issued 9 May 2001
Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION AS REQUIRED BY 46 CFR 67.315._x001C_ CORRECT PRIOR TO OPERATING VESSEL
Lifesaving
Issued 9 May 2001
Resolved
PROVIDE EMERGENCY RESPONSE TRAINING AS REQUIRED BY 46 CFR 185.420
Lifesaving
Issued 27 July 2000
Resolved
PROVIDE PROPER FIRST AID KIT AS REQUIRED BY 46 CFR 184.710
Electrical
Issued 27 July 2000
Resolved
REMOVE DEAD ENDED WIRES IN STEERING & SHAFT COMPARTMENTS AS REQUIRED BY 46 CFR 183.340
Construction/Loadline
Issued 27 July 2000
Resolved
REPAIR BILGE HIGH LEVEL ALARM IN STEERING COMPARTMENT AS REQUIRED BY 46 CFR182.530
Accommodation/Occupational Safety
Issued 27 July 2000
Resolved
REPLACE OR REPAIR SMOKE DETECTOR IN V BERTHING AS REQUIRED BY 46 CFR 176.810(a)(7)
Engineering
Issued 27 July 2000
Resolved
PROVIDE FLASH SHIELD DRIP PAN ON RACOR FUEL FILTER AS REQUIRED BY 46 CFR 182.455(b)(6)
Lifesaving
Issued 27 July 2000
Resolved
PROVIDE UP TO DATE TRAINING LOGS AS REQUIRED BY 46 CFR 185.420
Engineering
Issued 27 July 2000
Resolved
TIGHTEN SHAFT PACKING AS REQUIRED BY 46 CFR 176.802(c)
Construction/Loadline
Issued 24 April 2000
Resolved
PROVIDE AND INSTALL PROPER BILGE CONNECTIONS ON THE OVERBOARD DISCHARGE VALVES FOR BILGE SYSTEM PRIOR TO CARRYING PASSENGERS AS REQUIRED BY 46 CFR 182.510.
Engineering
Issued 24 April 2000
Resolved
RENEW VALVE HANDLE FOR EMERGENCY FUEL SHUTOFF PRIOR TO CARRYING PASSENGERS AS REQUIRED BY 46 CFR 182.455.
Lifesaving
Issued 24 April 2000
Resolved
RENEW HYDROSTATIC RELEASE AS REQUIRED BY 46 CFR 185.740 PRIOR TO CARRYING PASSENGERS.
Construction/Loadline
Issued 30 April 1998
Resolved
PROPERLY SEAL OPENINGS IN FORWARD ENGINE ROOM BULKHEAD. 46 CFR 176.802.
Electrical
Issued 30 April 1998
Resolved
PROVIDE AND POST MANUFACTURERES DATA PLATE ON GENERATOR. 46 CFR 183.05-5
Electrical
Issued 30 April 1998
Resolved
PROVIDE A MEANS TO DERATE THE GENERATOR TO 80% OF THE RATED LOAD. 46 CFR 183.10-5(f)(2).
Electrical
Issued 30 April 1998
Resolved
PROVE PROPER OPERATION OF THE AMP METER. 46 CFR 183.10-5(g).
Casualty record · 4
27 March 2017Routine · role: Involved in a Marine Casualty · activity 6112288
1 November 2019Routine · role: Involved in a Marine Casualty · activity 6863194
9 May 2020Routine · role: Involved in a Marine Investigation (non-casualty) · 1 injured · activity 7062996
2 February 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 7861205
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.