EMERALD

EMERALD is a 1981 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2016, most recently in July 2026, along with 86 deficiencies, 2 operational controls and 4 casualty investigations between 2017 and 2024.

Records from 2016 to 2026. Most recent: inspection, 13 July 2026.

Built
1981
Last inspected
13 July 2026
Documentation
Case Pending · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 July 2026
…with no type recorded7
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD3763
Flag
UNITED STATES
Maury page id
psix-53367

Documentation record

Registered dimensions (L × B × D)40.1 ft × 13.6 ft × 6.8 ft
Registered tonnagegross 19 / net 17
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCOMMERCIAL BOAT WORKS · MEDLEY, FL, UNITED STATES · built 1981
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeSail (Distinct Keel)
Hull configurationMonohull
Hailing portJUPITER, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationCase Pending · issued 17 September 2025 · expires 30 April 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Simplified, Gross Ton
17 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 27

13 July 2026 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8437319
6 June 2026 Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 8401086
15 April 2026 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8418565
25 September 2025 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8241272
13 November 2024 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8034842
16 October 2024 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8020178
1 May 2024 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7932055
4 February 2024 Administrative Inspection · DAPI Audit · Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7860367
2 February 2024 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7861205
8 November 2023 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7806702
7 December 2022 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7605415
17 August 2022 Administrative Inspection · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7535969
10 August 2021 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7282252
5 November 2020 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7090326
20 August 2020 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7037975
9 May 2020 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7062996
1 November 2019 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6863194
8 October 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6830637
16 October 2018 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6562491
22 May 2018 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6420512
21 June 2017 Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 6183494
14 June 2017 Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6175893
27 March 2017 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6112288
23 January 2017 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6075266
23 January 2017 Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6119886
19 October 2016 Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6025431
28 June 2016 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5922661

Deficiency record · 86

11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 25 September 2025 Resolved
Each life float must be fitted with a light. Light is inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2025
Resolution: Installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 September 2025 Resolved
On a vessel of at least 26 feet, a visual and audible alarm must be provided at the operating station. Visual for E/R high water alarm is inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2025
Resolution: Corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 25 September 2025 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. E/R bilge pump indicator is inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2025
Resolution: Corrected.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 25 September 2025 Resolved
No marine employer shall engage or employ any individual to serve as a crewmember unless the individual passes a chemical test. Provided proof on enrollment for crewmember in question.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 26 September 2025
Resolution: Provided.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 25 September 2025 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions. Instructions are not up-to-date.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2025
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 September 2025 Resolved
Remote fuel shutoff station must be marked in clear legible letters at least 1 inch high. Marking is only about 1/2 inch in hight.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2025
Resolution: Corrected.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 25 September 2025 Resolved
A person may not employ or engage an individual in a position required to hold an MMC unless that individual maintains a current medical certificate. Owner's medical certificate is expired. Cannot engage in a position that requires an MMC.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 1 March 2026
Resolution: Vessel was sold and previous owner no longer asscoaited with the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 13 November 2024 Resolved
Except as noted in paragraph (c) of this section, stations in the maritime service must be licensed by the FCC either individually or by fleet. Station License missing. Vessel restricted to not more than 1000 feet from shore. 47 CFR 80.13
Action required: 705 - Other - as specified
Resolved 14 November 2024
Resolution: Provided.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 13 November 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: U.S. Coast Pilot [name withheld] List, Tide tables, Current Tables. Extracts from the publications may be provided. Publications outdated or missing.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2024
Resolved 13 December 2024
Resolution: Provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 November 2024 Resolved
A vessel must carry either a first-aid kit approved under 160.041 or a kit with equivalent content. Content expired or missing. Burn gel, ointment, ammonia inhalant etc.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2024
Resolved 18 November 2024
Resolution: Provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 November 2024 Resolved
The discharge ends of fuel tank vents must be fitted with removable flame screen or flame arresters. The screen must consist of a single corrosion resistant wire of at least 30x30 mesh. Screen missing.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2024
Resolved 18 November 2024
Resolution: Installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 13 November 2024 Resolved
On a vessel of at least 26', a visual and audible alarm must be provided at the operating station. E/R visual indicator inoperable.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2024
Resolved 18 November 2024
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 November 2024 Resolved
Monthly inspection required by NFPA 10 May be conducted by owner, operator, or person-in-charge. No evidence of monthly checks being conducted. Corrected on the spot
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 14 November 2024
Resolved 13 November 2024
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 4 February 2024 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Marine employer failed to produce evidence of a satisfactory drug and alcohol program/policy, marine employer failed to direct required drug testing with in time requirements due to a SMI. Marine employer failed to produce a current roster of employees enrolled in the required alcohol and drug testing program. Vessel was found operating, with paying passengers onboard without a credentialed master onboard. Vessel is restricted from carrying passengers until; 1. Marine employer can produce satisfactory evidence of a satisfactory drug and alcohol program. 2. Marine employer can produce a current roster of employees enrolled in the drug testing program. 3. Vessel receives a satisfactory additional in-service inspection by an attending CG marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 February 2024
Resolution: Owner provided a satisfactory DAPI/EAP porogram adn vessel is operating in accordance with its COI.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 November 2023 Resolved
A vessel on which a pre-engineered system is installed must have the following: A means to reset devices used to automatically shut down engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2023
Resolution: Fireboy bezel replaced. System tested. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 November 2023 Resolved
The owner or a qualified servicing facility as applicable must conduct the following inspections and tests: Portable extinguishers must be inspected and maintained IAW NFPA 10. Extinguishers and fixed firefighting system have not been serviced in over a year.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 November 2023
Resolution: Report provided. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 November 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts, U.S. Coast Guard Coast Pilot, Tides tables, and Currents tables. Pubs not up-to-date.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2023
Resolved 16 November 2023
Resolution: Provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 8 November 2023 Resolved
A vessel must carry either a first-aid kit approved under 160.041 or a kit with equivalent contents. Vessel missing aspirin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 November 2023
Resolved 16 November 2023
Resolution: Provided.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 7 December 2022 Resolved
EPIRB hydrostatic release unit is expired. Replace HRU. Operations restricted to no more than 3 miles from shore. 46 CFR 185.740
Action required: 705 - Other - as specified
Resolved 12 December 2022
Resolution: HRU replaced.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 7 December 2022 Resolved
10-B:C portable fire extinguisher not provided. Provide and mount 10-B:C fire extinguisher at operating station. 46 CFR 185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2022
Resolved 15 December 2022
Resolution: Extinguisher installed.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 7 December 2022 Resolved
Emergency instruction not posted. Post emergency instructions at operating station. 46 CFR 185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2022
Resolved 12 December 2022
Resolution: Emergency instructions posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 December 2022 Resolved
COI not posted. Post COI in an area to allow passengers to view. 46 CFR 176.302
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2022
Resolved 12 December 2022
Resolution: COI posted.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 December 2022 Resolved
Any vessel over 12 meters in length is required to have a masthead light. Vessel has an all around anchor light but not a separate masthead light as required. 46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 December 2022
Resolved 15 December 2022
Resolution: Masthead light installed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 12 October 2022 Resolved
Numerous voids found in the hull's laminate both port and starboard side. Marked areas to be repaired prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 14 October 2022
Resolution: Repairs SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 12 October 2022 Resolved
MSD disharge through hull valve doesn't completly close. Valve to be repaired/replaced prior to credit dry-dock. 46 CFR 179.360
Action required: 705 - Other - as specified
Resolved 14 October 2022
Resolution: Valve replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 12 October 2022 Resolved
Ladders into machinery space and into v-berth are loose. Secure ladders prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 14 October 2022
Resolution: Ladders secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 October 2022 Resolved
Batteries are not secure and not protected from water splash. Batteries to be secured and covered prior to credit dry-dock. 46 CFR 183.350
Action required: 705 - Other - as specified
Resolved 14 October 2022
Resolution: Batteres secured in battery boxes.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 8 September 2021 Resolved
EPIRB registration expired. Provide current registration for vessel's EPIRB. Route restricted to no more than 3 miles from shore. 46 CFR 185.728
Action required: 705 - Other - as specified
Resolved 8 September 2021
Resolution: Current EPIRB registration provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 September 2021 Resolved
Machinery space high level visual alarm inoperable. Repair alarm to the satisfaction of marine inspector. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2021
Resolved 8 September 2021
Resolution: Alarm repaired.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 September 2021 Resolved
Lazerette bilge high level visual alarm inoperable. Repair alarm to the satisfaction of marine inspector. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2021
Resolved 21 September 2021
Resolution: Alarm operates SAT.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 September 2021 Resolved
Fuel tank space automatic electrical submersible pump and alarm inoperable. Repair pump and alarm to the satisfaction of marine inspector. 46 CFR 182.530
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 September 2021
Resolved 8 September 2021
Resolution: Alarm repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 19 November 2020 Resolved
Drug and alcohol program employee list is expired. Provide current employee list. 46 CFR 16.230
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 November 2020
Resolution: Current employee list provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 November 2020 Resolved
Life ring is in non-serviceable condition. Provide serviceable life ring. 46 CFR 180.70
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2020
Resolution: Life ring replaced.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 November 2020 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 19 November 2020
Resolution: Proof of current FCC Station License provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 19 November 2020 Resolved
Radio-telephony Safety Certificate not on board.. Provide Safety Certificate. Passenger operations restricted to no more than 1000 feet from shore. 46 CFR 80.401
Action required: 705 - Other - as specified
Resolved 21 November 2020
Resolution: Safety Certificate provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 19 November 2020 Resolved
Lazerette bilge high water alarm assembly is in non-serviceable condition. Replace alarm assembly. 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2020
Resolution: Assembly replaced; test SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 19 November 2020 Resolved
Alcohol testing strips expired. Provide current alcohol testing strips or equivalent. 46 CFR 4.06-3
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 December 2020
Resolution: Test strips provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 November 2020 Resolved
Operating station fire extinguisher is located in a cabinet and not labeled. Label location of fire extinguisher. 46 CFR 181.520
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2020
Resolved 20 November 2020
Resolution: Extinguisher mounted outside of cabinet.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 November 2020 Resolved
Emergency fuel shut-off valve label is unreadable. Re-label emergency fuel shut-off valve location in a way that prevents the label from being easily removed. 46 CFR 185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2020
Resolved 3 December 2020
Resolution: Fuel shut off valve location labeled with placard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 November 2020 Resolved
Life jacket donning placard does not show the donning procedures for the same type of jacket provided onboard. Provide proper donning placard for type of life jacket onboard. 46 CFR 185.516
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2020
Resolved 3 December 2020
Resolution: Appropriate donning placard posted.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 19 November 2020 Resolved
Navigation light configuration is not in accordance with navigation rules. Masthead light and stern light to be arranged as separate lights with proper arc of visibility. Current configuration has masthead and stern light as an all around white light. 46 CFR 183.420
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 December 2020
Resolved 3 December 2020
Resolution: Nav light configuration SAT.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 October 2020 Resolved
Installed pre-engineered fire extinguishing system annual inspection is overdue. Provide report of satisfactory fire fighting equipment inspection/servicing prior to operating with passengers. 46 CFR 176.810(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 October 2020
Resolution: Service report provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 October 2020 Resolved
Emergency fuel shut off valve at tank does not close properly. Installed valve is a 45 degree actuating valve but the valve turns past 45 degrees. Valve to be repaired or replaced to ensure valve closes as designed prior to credit dry-dock. 46 CFR 182.455(b)(4)
Action required: 705 - Other - as specified
Resolved 23 October 2020
Resolution: Valve operates properly.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 7 October 2020 Resolved
Numerous areas of hull have blisters or damage to the fiberglass. Make repairs to the satisfaction of marine inspector. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 12 October 2020
Resolution: Repairs made SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2020 Resolved
Propeller found loose on shaft. Remove propeller to allow for a visual examination of the shaft, shaft key-way and shaft to propeller key prior to credit dry-dock.
Action required: 705 - Other - as specified
Resolved 15 October 2020
Resolution: Prop installed SAT.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 7 October 2020 Resolved
Forward bulkhead in machinery space is cracked and de-laminated. Make repairs prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 30 October 2020
Resolution: Repairs made SAT.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 7 October 2020 Resolved
Fiberglass tabs at corners of the forward compartment are de-laminated. Make repairs prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 30 October 2020
Resolution: Repairs made SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 7 October 2020 Resolved
Overhead hand rails below operating station loose. Secure hand rails to topside deck prior to credit dry-dock. 46 CFR 177.900
Action required: 705 - Other - as specified
Resolved 30 October 2020
Resolution: Rails secured.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 7 October 2020 Resolved
Forward main deck found to be soft with water intrusion. Provide repair proposal to marine inspector. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 30 October 2020
Resolution: Repairs made SAT.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 7 October 2020 Resolved
Top deck/operating station deck found to be soft possibly requiring extra support. Provide repair proposal to marine inspector. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 30 October 2020
Resolution: Repairs made SAT.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 29 October 2019 Resolved
Repair/replace bilge high level alarms for engine room and mid-void space prior to carrying passengers. 46 CFR 182.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2019
Resolution: Alarms repaired and work properly.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 29 October 2019 Resolved
Breaker panel has no box to cover the back of the breakers and wiring to breakers. Panel also has open spaces that need to be closed off. Panel to be made totally enclosed prior to carrying passengers. 46 CFR 183.330(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2019
Resolution: Back of panel covered.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 October 2019 Resolved
Navigation lights inoperative. Repair lights prior to operations. 46 CFR 420
Action required: 60 - Rectify deficiencies prior to movement
Resolved 31 October 2019
Resolution: Nav lights working properly.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 October 2019 Resolved
4 adult life jackets non-serviceable. Total adult persons count reduced to 16. 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 15 November 2019
Resolution: 4 life jackets replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 29 October 2019 Resolved
Fuel tank space watertight hatch has broken hardware and does not fully close and seal. Repair hatch to make watertight. 46 CFR 179.360
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2019
Resolved 15 November 2019
Resolution: Hatch repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 29 October 2019 Resolved
Install metallic flame shield on secondary fuel filter bowl. 46 CFR 182.4558
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2019
Resolved 15 November 2019
Resolution: Flame shield installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 October 2019 Resolved
Install permanent type connectors at battery cable to terminal connections. 46 CFR 183.350
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 15 November 2019
Resolution: Lock nuts installed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 October 2019 Resolved
Post life jacket donning placards for both type of life jackets onboard. 46 CFR 185.516
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2019
Resolved 15 November 2019
Resolution: Donning placard posted.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 29 October 2019 Resolved
Move emergency instructions to make fully visible to passengers and crew. 46 CFR 185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2019
Resolved 15 November 2019
Resolution: Emergency instructions made visible.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 29 October 2019 Resolved
8 distress signals to expire in 2 days. Replace 8 distress signals with current signals. 46 CFR 180.68
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2019
Resolved 15 November 2019
Resolution: Distress signals SAT.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 29 October 2019 Resolved
Post Certificate of Inspection and Stability letter. 46 CFR 176.302
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 November 2019
Resolved 22 November 2019
Resolution: COI and Stab. posted.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 22 May 2018 Resolved
Place name on both sides of the bow in 4 inch letters.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2018
Resolved 11 July 2018
Resolution: owner has placed 4 inch lettering on the bow
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 22 May 2018 Resolved
Submit repair plan for cracks in deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2018
Resolved 11 July 2018
Resolution: Owner has plan to complete more extensive repairs to deck in upcoming drydock.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 15 June 2017 Resolved
Provide current COD.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2017
Resolution: Provided current COD.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 June 2017 Resolved
Prove proper operation of bilge alarm light for fwd compt.
Due 30 June 2017
Resolved 25 July 2017
Resolution: Proved proper operation of bilge alarm light.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 June 2017 Resolved
Update expired items in first aid kit.
Due 30 June 2017
Resolved 28 June 2017
Resolution: Updated first aid kit.
Lifesaving › Lifebuoys › Serviceable
Issued 15 June 2017 Resolved
Renew line around ring buoy or replace ring buoy.
Due 30 June 2017
Resolved 28 June 2017
Resolution: renewed line around life ring.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 June 2017 Resolved
Provide 3 more type I adult PFD's, vessel restricted to 17 adults until 3 more are added.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 28 June 2017
Resolution: Added all required lifejackets.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 15 June 2017 Resolved
Address all drug and alcohol program defs as discussed by the CGMI.
Action required: 705 - Other - as specified
Resolved 25 July 2017
Resolution: Corrected all defs with the DAPI program.
Fire Fighting › Structural Fire Protection - General › Fiber Reinforced Plastic
Issued 15 June 2017 Resolved
Make aft engine room bulkhead watertight.
Due 15 June 2017
Resolved 15 June 2017
Resolution: Made aft engine room bulkhead watertight.
Documentation › Certificates/Documents › FCC SSL
Issued 15 June 2017 Resolved
Provide copy of FCC SSL.
Due 30 June 2017
Resolved 25 July 2017
Resolution: Provided FCC SSL.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 23 January 2017 Resolved
Vessel was operating with 14 passengers and did not maintain proper manning, the Captain dove also just leaving the deckhand onboard. (the deckhand is a licensed Captain also).
Due 23 January 2017
Resolved 15 March 2017
Resolution: Vessel owner rcvd LOW and has deemed to properly man vessel.
Engineering › Reduction Gearing/Clutches › Oil Spray
Issued 23 January 2017 Resolved
Prove proper operation of the reduction gear.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 January 2017
Resolution: Proved proper operation of the reduction gear.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 19 October 2016 Resolved
Replace hose on Shaft log.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2016
Resolution: Owner has replaced the shaft log hose.
Construction/Loadline › Hull › Weld
Issued 19 October 2016 Resolved
Repair cracked weld on dive boarding ladder.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2016
Resolution: Owner has rewelded cracked ladder.
Lifesaving › Lifefloat › Serviceable
Issued 28 June 2016 Resolved
Replace lifefloat.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2016
Resolution: Owner has replaced the lifefloat with a IBA.
Lifesaving › Visual Distress Signals (General) › Quantity
Issued 28 June 2016 Resolved
Provide 2 additional approved flares.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2016
Resolution: Owner provided the correct amount of approved flares.
Communications › Radio Communications › VHF Radiotelephone
Issued 28 June 2016 Resolved
Prove proper operation of VHF-FM radio.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2016
Resolution: Owner proved proper operation of VHF-FM radio.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 28 June 2016 Resolved
Provide log book to document emergency drills and epirb checks more consistently.
Due 29 June 2016
Resolved 29 June 2016
Resolution: Provided book to document drills.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 28 June 2016 Resolved
Provide CG light list.
Due 29 July 2016
Resolved 19 July 2016
Resolution: Provided CG light list.
Communications › Alarms/Indicators › High Water Alarm
Issued 28 June 2016 Resolved
Label hight water alarms.
Due 29 July 2016
Resolved 19 July 2016
Resolution: Owner labeled high water alarms.
Stability › Watertight Integrity › General
Issued 28 June 2016 Resolved
Prove proper operation of lazerette deck hatch.
Due 29 July 2016
Resolved 19 July 2016
Resolution: Proved proper operation of deck hatch.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 28 June 2016 Resolved
Seal penetration in fwd engine room bulkhead.
Due 29 June 2016
Resolved 29 June 2016
Resolution: Owner sealed penetration in fwd e/r bulkhead.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 June 2016 Resolved
Remove deadend wiring in engine room as dicussed with CGMI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 June 2016
Resolution: Owner has removed deadend wire in the engine room.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 28 June 2016 Resolved
Provide 7 more type I lifejackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 July 2016
Resolved 29 June 2016
Resolution: Owner placed the proper number of lifejackets onboard.
Stability › Watertight Integrity › General
Issued 28 June 2016 Resolved
Install securing device on engine room deck hatch.
Due 29 July 2016
Resolved 19 July 2016
Resolution: Securing devices installed on engine room deck hatch.

Casualty record · 4

27 March 2017Routine · role: Involved in a Marine Casualty · activity 6112288
1 November 2019Routine · role: Involved in a Marine Casualty · activity 6863194
9 May 2020Routine · role: Involved in a Marine Investigation (non-casualty) · 1 injured · activity 7062996
2 February 2024Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 7861205
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.