WESTERN TRITON III

WESTERN TRITON III is a 1979 mobile offshore drilling unit. The Coast Guard has recorded 45 inspections since 1981, most recently in April 1993, along with 180 deficiencies.

Records from 1981 to 1993. Most recent: inspection, 2 April 1993.

Built
1979
Last inspected
2 April 1993
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-53380

Inspections, by type

…with no type recorded18
Years with a record 13 calendar years (1981–1993)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 33 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it3846 - Regulatory (Subpart C or D), Net Ton
3846 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 45

2 April 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 835368
22 December 1992 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1137462
17 November 1992 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1356171
24 January 1992 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 956588
7 November 1991 Deficiency Check · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 932356
23 October 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1254198
14 September 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1440617
20 July 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1248499
19 July 1991 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1251437
11 March 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 926805
23 January 1991 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 931798
27 November 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 900975
27 November 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 930999
26 March 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 911049
20 February 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1237614
5 February 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1226602
3 January 1990 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 922461
13 November 1989 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 924520
13 February 1989 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1035858
21 December 1988 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1341565
17 December 1988 Hull Examination · Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 887904
2 December 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1206016
29 October 1987 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1311644
2 October 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013196
10 July 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017216
1 April 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1022733
28 January 1987 Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1327312
24 June 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300869
12 February 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1293172
15 December 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990036
18 November 1985 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 988126
5 December 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 976656
14 November 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 975805
25 June 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 974205
17 April 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1281989
26 January 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1280161
27 October 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 972388
27 July 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1274017
26 April 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1277130
2 December 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963747
2 November 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966178
16 September 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276743
5 May 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969521
5 December 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965730
29 October 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963626

Deficiency record · 180

Fire Fighting
Issued 17 November 1992 Resolved
REPLACE FIREMANS BOOTS IN UPPER GEAR LOCKER.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Fire Fighting
Issued 17 November 1992 Resolved
TEST OXYGEN/COMBUSTABLE GAS METERS.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Lifesaving
Issued 17 November 1992 Resolved
REPAIR AIR SYSTEM IN BOTH LIFEBOATS.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Lifesaving
Issued 17 November 1992 Resolved
INSTALL 3-TON SHACKLE ON PORT LIFERAFT.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Electrical
Issued 17 November 1992 Resolved
REPLACE GENERAL ALARM BATTERIES.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Lifesaving
Issued 17 November 1992 Resolved
CLEAN/PAINT EXTERIOR OF BOTH LIFEBOATS.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Accommodation/Occupational Safety
Issued 17 November 1992 Resolved
REPAIR HANDRAIL HALFWAY UP DERRICK AS NECESSARY.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Electrical
Issued 17 November 1992 Resolved
REPLACE BROKEN RECEPTACLE AFT BLKHD. DRILL FLOOR.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Electrical
Issued 17 November 1992 Resolved
REMOVE/DEAD END WIRES IN FOLLOWING LOCATIONS: DOGHOUSE, BEHIND SWITCHBOX AFT BLKHD DRILL FLOOR, STBD. SIDE BENEATH DRILL FLOOR, WIRE BUNDLE HANGING FROM DRILL FLOOR (AFT), OVHD. IN SACK ROOM.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Electrical
Issued 17 November 1992 Resolved
PROPERLY SECURE ELECTRIC CABLE RUNNING UP DERRICK.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Electrical
Issued 17 November 1992 Resolved
MOUNT LIGHT FIXTURE POWER SUPPLY CABLE PORT SIDE BENEATH DRILL FLOOR.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Electrical
Issued 17 November 1992 Resolved
REMOVE PAINT FROM ALL EXPLOSION PROOF FIXTURES.
Condition: Unknown
Due 18 January 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 17 November 1992 Resolved
PROVE PROPER OPERATION OF ALL PURGE INDICATORS/ALARMS IN DRILLERS BOOTH.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Electrical
Issued 17 November 1992 Resolved
RETEST GENERAL ALARM BELLS: PORT AFT HOUSE, WELDERS SHACK (PLACARD), WHEEL HOUSE, SACK ROOM (PLACARD), STOREKEEPERS OFFICE, MUD PIT (PLACARD).
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Electrical
Issued 17 November 1992 Resolved
RENEW CABLE TRAY, RE-MOUNT CABLE AS NECESSARY, STBD. SIDE CRANE PEDESTAL INSHALE SHAKER AREA.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Electrical
Issued 17 November 1992 Resolved
MOUNT/SECURE CABLE TO SHALE SHAKER.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Electrical
Issued 17 November 1992 Resolved
MOUNT J-BOX IN MUD PIT ROOM.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Electrical
Issued 17 November 1992 Resolved
MOUNT THREE J-BOXES, REMOVE CUT WIRES AND EXCESS WIRE COILS IN OVHD. CABLE TRAY IN MUD PUMP ROOM.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Electrical
Issued 17 November 1992 Resolved
PROPERLY INSTALL (SINGLE BANK) WIRE CABLE ABOVE MUD PUMP CONTROLLERS.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Electrical
Issued 17 November 1992 Resolved
REPAIR OVERHEAD CABLE TRAY IN SACK ROOM.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Construction/Loadline
Issued 17 November 1992 Resolved
PROPERLY INSTALL HANDWHEELS ON BILGE SUCTION VALVES IN AIR COMPRESSOR ROOM.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Construction/Loadline
Issued 17 November 1992 Resolved
INSTALL MISSING BILGE PUMP MOTOR.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Electrical
Issued 17 November 1992 Resolved
PROVE PROPER OPERATION OF MUD PIT VENTILATION SHUTDOWN AND ALARM.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Fire Fighting
Issued 17 November 1992 Resolved
REPAIR VALVE TO FIRE STATION NO. 3.
Condition: Unknown
Due 23 December 1992
Resolved 23 December 1992
Lifesaving
Issued 7 November 1991 Resolved
PROVIDE ONE JACKNIFE WITH OPENER FOR THE #2 LIFEBOAT.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Accommodation/Occupational Safety
Issued 7 November 1991 Resolved
PROVIDE AN ASME APPROVED TEMPERATURE AND PRESSURE RELIEF VALVE FOR THE #1 AND #3 HOT WATER HEATERS.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Lifesaving
Issued 7 November 1991 Resolved
REFILL AND PROVIDE HYDROSTATIC TEST FOR BOTH FIRE LOCKER SURVIVAIR AIR BOTTLES FOR THE SCBA's.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Documentation
Issued 7 November 1991 Resolved
PROVIDE ON BOARD A COAST GUARD APPROVED OPERATIONS MANUAL IN ACCORDANCE WITH 46 CFR 109.121.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Fire Fighting
Issued 7 November 1991 Resolved
PROVIDE ON BOARD SERVICED B-V SEMI-PORTABLE FIRE EXTINGUISHER FOR THE HELO DECK.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Lifesaving
Issued 7 November 1991 Resolved
PAINT THE BRAKE RELEASE LEVERS ON BOTH DAVITS ORANGE AND PROVIDE A YELLOW LINE MARK ON THE FALLS AND DAVIT AS PER OPERATING INSTRUCTIONS.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Accommodation/Occupational Safety
Issued 7 November 1991 Resolved
PROVIDE GAUGES ON ALL PURGE AIR SYSTEMS TO SHOW PRESSURE LESS THAN 3 PSI AND PROVIDE LOSS OF PURGE AIR AUDIBLE ALARM FOR THE GEOLOGRAPH UNIT.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Accommodation/Occupational Safety
Issued 7 November 1991 Resolved
PROVIDE ASME APPROVED RELIEF VALVES SET AT OR BELOW 100 PSI ON THE POTABLE WATER TANKS.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Lifesaving
Issued 7 November 1991 Resolved
PROVIDE APPROPRIATE OPERATING INSTRUCTIONS FOR THE DAVIT LAUNCHED INFLATABLE LIFERAFTS AND POST ON CONTAINERS.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Electrical
Issued 7 November 1991 Resolved
REPLACE THE BOW OBSTRUCTION LIGHT LENSE AND REPAIR OR REPLACE THE STBD OBSTRUCTION LIGHT BULB CHANGER.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Accommodation/Occupational Safety
Issued 7 November 1991 Resolved
PROVIDE ASME APPROVED RELIEF VALVE ON #3 AIR COMPRESSOR UNIT NOT TO EXCEED THE MAXIMUM ALLOWABLE WORKING PRESSURE.
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Lifesaving
Issued 14 September 1991 Resolved
RENEW RELIEF VALVE ON DRILL FLOOR AIR RECEIVER_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 September 1991
Resolved 14 September 1991
Lifesaving
Issued 14 September 1991 Resolved
REPAIR THE GOVERNOR BRAKE ON THE DAVIT WINCH FOR LIFERAFT TO LOWER LOAD AT NOT MORE THAN 120 FEET PER MINUTE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 24 October 1991
Resolved 24 October 1991
Electrical
Issued 20 July 1991 Resolved
PROPERLY HANG ALL WIRES LOCATED PORT SIDE UNDER DRILL FLOOR.
Condition: Unknown
Due 20 July 1991
Resolved 20 July 1991
Construction/Loadline
Issued 20 July 1991 Resolved
MAKE PROPER REPAIRS TO HOLED PIPE IN SALT WATER LINE ABOVE WATER MAKER.
Condition: Unknown
Due 20 July 1991
Resolved 20 July 1991
Electrical
Issued 20 July 1991 Resolved
PROVIDE SEALED FITTING ON HORN IN CHOKE PANEL ON STBD SIDE OF DRILL FLOOR.
Condition: Unknown
Due 20 July 1991
Resolved 20 July 1991
Construction/Loadline
Issued 20 July 1991 Resolved
CONDUCT UNDERWATER HULL EXAM DURING NEXT RIG MOVE (NO LATER THAN 17 DEC 91)
Condition: Unknown
Due 20 July 1991
Resolved 20 July 1991
Electrical
Issued 20 July 1991 Resolved
PROPERLY MOUNT ALL TOTCO UNIT LOCATED BEHIND DRILLER'S CONSOLE.
Condition: Unknown
Due 20 July 1991
Resolved 20 July 1991
Electrical
Issued 20 July 1991 Resolved
PROVIDE SEALED FITTINGS AND PROPER WIRE FOR DIVISION I LOCATIONS TO EXPLOSION PROOF BOX ON WESTERN CEMENT UNIT OVERHEAD SHAKER ROOM.
Condition: Unknown
Due 20 July 1991
Resolved 20 July 1991
Electrical
Issued 20 July 1991 Resolved
PROPERLY MOUNT ALL JUNCTION BOXES LOCATED BEHIND DRILLER'S CONSOLE.
Condition: Unknown
Due 20 July 1991
Resolved 20 July 1991
Electrical
Issued 27 November 1990 Resolved
PROVIDE EXPLOSION PROOF BOX OR PURGE AIR TO SONAT TELCO TOOLFACE INDICATOR.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Lifesaving
Issued 27 November 1990 Resolved
SECURELY MOUNT BOTH FIRE EXTINGUISHERS IN #1 AND #2 LIFEBOATS.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Lifesaving
Issued 27 November 1990 Resolved
PROVIDE NEW TOOL KIT CONTAINER FOR #2 LIFEBOAT.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROPERLY LABEL AND MARK GENERAL ALARM BELL ON SHALE SHAKER FLOOR.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Construction/Loadline
Issued 27 November 1990 Resolved
REPAIR LEAKING PIPE JOINT ABOVE WATER MAKER.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Fire Fighting
Issued 27 November 1990 Resolved
REPAIR OR REPLACE ALL MULTI - PURPOSE FIRE NOZZLES.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
REMOUNT WIRE FOR LOUD SPEAKER AND FLOODLIGHT LOCATED ON THE TOP STARBOARD STERN OF QUARTERS.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE PURGE PURGE AIR AND LOSS OF PURGE ALARM TO EXLOG BOXES ON FORWARD PORT BULKHEAD OF DRILL FLOOR (TOTAL OF TWO).
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROPERLY MOUNT ALL JUNCTION BOXES FOR TOTCO BOXES BENEATH DRILL FLOOR ON PORT SIDE.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
REMOVE DEAD END CABLE FORWARD OF THE BRAKE COOLING UNIT.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
POUR EYS FITTING FOR MUD DITCH FLOW SENSOR BENEATH STARBOARD FORWARD RIG FLOOR.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE SEALED FITTING FOR FLOW SENSOR ON MUD DITCH UNDERNEATH STARBOARD FORWARD RIG FLOOR.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE SEALED FITTING FOR LEVEL INDICATORS IN TRIP TANK. (TOTAL OF TWO)
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
POUR EYS FITTING FOR JUNCTION BOX BENEATH PHONE AT TRIP TANK.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Navigation
Issued 27 November 1990 Resolved
PROPERLY MOUNT STERN LIGHT IN ACCORDANCE WITH 46 CFR 81 APPENDIX A.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE PURGE AIR AND LOSS OF PURGE ALARM TO TOTCO PEN RECORDERS.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE PURGE AIR AND LOSS OF PURGE ALARM TO TOTCO TOTAL GAS DETECTOR RE- MOTE DISPLAY UNIT ON DRILL FLOOR.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE PURGE AIR AND LOSS OF PURE ALARM TO GEOGRAPH UNIT.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
POUR EYS FITTING FOR TOTCO HORN CONTROL BOX.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
POUR EYS FITTING FOR PRESSURE SWITCH TO EXLOG MONITOR ON DRILL FLOOR.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
REMOUNT EXPLOSION PROOF JUNCTION BOX IN CHOKE PANEL ON STARBOARD SIDE OF THE DRILL FLOOR.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE PURGE AIR AND LOSS OF PURGE ALARM TO CHOKE PANEL ON THE STARBOARD SIDE OF THE RIG FLOOR.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
CLEAR PURGE LINES FROM PLENUM TO JUNCTION BOX FOR DRAW WORKS MOTORS AND PROVE PURGE (TOTAL OF TWO).
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE NEGATIVE PRESSURE TO MUD PIT ROOM. (PRESSURE TO BE MORE NEGATIVE THAN THAT IN MUD PUMP ROOM.) ALSO, PROVIDE LOSS OF VENTILATION ALARM (SEE REQUIREMENT #33).
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE SEALED FITTING FOR STARBOARD AFT LIGHT IN MUD PIT ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE SEALED FITTINGS FOR ALL MUD PIT FLOATS (6 IN ALL) IN MUD PIT ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
REPLACE MISSING BOLTS ON SWTICH BOX (EXPLOSION PROOF) FOR #2 AGITATOR IN MUD PIT ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROPERLY MOUNT EXPLOSION PROOF JUNCTION BOX TO #2 AGITATOR IN MUD PIT ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
POUR EYS FITTING FOR SWITCH TO #2 AGITATOR IN MUD PUMP ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE FIXED MOUNTED EXPLOSION PROOF BOX WITH SEALED FITTINGS ON EXLOG BOXIN MUD PIT ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
REPLACE MISSING BOLT ON SWITCH BOX TO #1 AGITATOR IN MUD PIT ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE PROPER BICC FITTING (FOR ARMORED CABLE) FOR GAS DETECTOR ABOVE #1 MUD PIT ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROPERLY MOUNT AND SUPPORT ALL WIRING RUNS IN MUD PIT ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE LOSS OF VENTILLATION ALARM ON EXHAUST FAN FOR MUD PIT ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Construction/Loadline
Issued 27 November 1990 Resolved
SUBMIT REPAIR PROPOSAL FOR LEAKING S/W PIPING IN OVERHEAD TO #1 DRILL WATERPUMP.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
POUR EYS FITTING FOR LIGHT IN PAINT LOCKER.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE SEALED FITTINGS FOR MUD PIT ROOM VENT FAN MOTORS.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE LEASHES FOR LIGHTS ABOVCE SHAKER PROCESSING PUMPS.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE AND INSTALL CLASS I DIVISION I UNIT FOR TOTCO CANARY UNIT ON SHAKERFLOOR. EXISTING UNIT ONLY ACCEPTABLE FOR CLASS I DIVISION II.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
REPLACE MISSING BOLTS ON PHONE BOX ON SHAKER FLOOR.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
REPLACE MISSING BOLTS ON EXPLOSION PROOF BOX BENEATH PHONE ON SHAKER FLOOR.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PERMANENTLY MOUNT HAS DETECTOR IN SHALE SHAKER AREA.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROPERLY MOUNT AND SUPPORT ALL OVERHEAD HORIZONAL RUNS OF CABEL IN SHALE SHAKER HOUSE AND ALONG MUD DITCH.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
MODIFY HAZARDOUS LOCATION DRAWING TO INCLUDE TWO NEWLY INSTALLED SHAKERS AND SUBMIT TO OFFICE ABOVE FOR APPROVAL. (DRAWING MAY BE MODIFIED TO FALL IN ACCORDANCE WITH 46 CFR SUBCHAPTERS I - A AND J
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
CHECK AND POUR ALL EYS FITTING IN SHALE SHAKER AREA.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE SEALED FITTING LEVEL INDICATOR OF STARBOARD FORWARD SHAKER.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE EXPLOSION PROOF UNITS FOR CLASS I DIVISION I FOR WESTERN CEMENT UNITS LOCATED FORWARD ON TOP OF THE SHAKER HOUSE.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
REMOVE SCOTT SPLICE FROM CABLE TO OUTLET CURRENTLY BEING USED BY TOTCO ABOVE SHAKER HOUSE BY STARBOARD CRANE PORT. INSTALLATION OF AN EXPLOSION PROOF JUNCTION BOX WITH SEALED FITTINGS WILL BE AN ACCEPTABLE REPAIR.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
POUR EYS FITTING FOR SWITCH TO #3 AGITATOR IN MUD PUMP ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
REPLACE MISSING BOLT FOR EXPLOSION PROOF SWITCH BOX TO #3 AGITATOR IN MUD PIT ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE LOSS OF PURGE COMING FROM ENCLOSURE FOR TOTCO RIG FLOOR MONITOR. (LOSS OF PURGE CURRENTLY SUPPLY LINE.)
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Lifesaving
Issued 27 November 1990 Resolved
PROVIDE ONE BOAT HOOK FOR #1 LIFEBOAT FOR A TOTAL OF TWO BOAT HOOKS.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Lifesaving
Issued 27 November 1990 Resolved
REPLACE RING BUOY LOCATED ON THE STARBOARD STERN.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Accommodation/Occupational Safety
Issued 27 November 1990 Resolved
REPAIR OR REPLACE DOOR NOB ON THE PORT AFT MAIN DECK ENTRY DOOR TO CHANGE ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Lifesaving
Issued 27 November 1990 Resolved
ATTACH HYDRO RELEASE ON LIFERAFT #1.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Lifesaving
Issued 27 November 1990 Resolved
HAVE LIFERAFTS #2,#4, AND #5 SERVICED BY A CERTIFIED SERVICE COMPANY.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Lifesaving
Issued 27 November 1990 Resolved
PROVIDE ONE ADDITIONAL HATCHET FOR #1 LIFEBOAT.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
REMOUNT WIRE FOR HELO DECK LIGHTS IN SEVERAL PLACES AROUND HELO DECK.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Lifesaving
Issued 27 November 1990 Resolved
PROVIDE A 6 FOOT BOARDING LADDER FOR #1 AND #2 LIFEBOAT.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Lifesaving
Issued 27 November 1990 Resolved
PROVIDE DAVIT LAUCH LIFERAFTS IN ACCORDANCE WITH MVI DISTRICT LETTER 16711/19 DATED 05APR88.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Lifesaving
Issued 27 November 1990 Resolved
REPLACE RING BUOY LIGHT BRACKET ON PORT AMIDSHIP RING BUOY.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Lifesaving
Issued 27 November 1990 Resolved
PROVIDE EMERGENCY FLOODLIGHTS FOR EMBARKATION STATIONS FOR DAVIT LAUNCHED LIFERAFTS.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Lifesaving
Issued 27 November 1990 Resolved
REPLACE RING BUOY AND RING BUOY BRACKET LOCATED ON THE PORT STERN.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Lifesaving
Issued 27 November 1990 Resolved
REPLACE RING BUOY AND RING BUOY LIGHT BRACKET LOCATED AT STARBOARD AMID- SHIPS.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Lifesaving
Issued 27 November 1990 Resolved
PROVIDE SUFFICIENT LENGTH OF HOSE TO REACH OUTSIDE HULL FOR BILGE PUMP IN #2 LIFEBOAT.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Lifesaving
Issued 27 November 1990 Resolved
PROVIDE WEAK LINK FOR #1 LIFERAFT.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
POUR EYS FITTING FOR EXHAUST VENT SWITCH LOCATED ON FORWARD STARBOARD BULKHEAD OF MUD PUMP ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
REPLACE GENERAL ALARM CONTACTOR ON PORT AFT BULKHEAD OF MUD PUMP ROOM WITH EXPLOSION PROOF TYPE FITTED WITH SEALED FITTING.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE SEALED FITTINGS FOR PRESURE SWITCHES FOR BOTH MUD PUMPS (TOTAL OF TWO).
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE SEALED FITTINGS FOR BOTH MUD PUMP SWITCHES (TOTAL OF TWO).
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE SEALED FITTINGS FOR CHARGING PUMPS IN MUD PUMP ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE EXPLOSION PROOF SWITCH BOXES FOR ALL EZLOG STROKE COUNTERS IN MUD PUMP ROOM (TOTAL OF FOUR.)
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE EXPLOSION PROOF GENERAL ALARM LIGHT WITH SEALED FITTING TO GENERAL ALARM LIGHT IN MUD PUMP ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE SEALED FITTINGS FOR RECEPTICAL ON PORT BULKHEAD OF MUD PUMP ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE SEALED FITTINGS FOR BOTH MUD PUMP VENT FAN SWITCHES.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE PURGE AIR (FROM CLEAN ATMOSPHERE) FOR BOTH MUD PUMP MOTORS (TOTAL OF FOUR.)
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE LOSS OF VENTILATION ALARM FOR MUD PUMP ROOM EXHAUST FAN.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE NEGATIVE PRESSURE TO MUD PUMP ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
MAKE EXPLOSION PROOF OR RELOCATE (OUTSIDE OF HAZARDOUS LOCATION) BATTERY CHARGERS ON STARBOARD BULKHEAD OF MUD PUMP ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE EXPLOSION PROOF EMERGENCY LIGHT WITH SEALED FITTING FOR STARBOARD AFT OF MUD PUMP ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE EXPLOSION PROOF HORN / BELL FOR GENERAL ALARM IN MUD PUMP ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE EXPLOSION PROOF DRIVER WITH SEALED FITTING TO PA HORN IN MUD PUMP ROOM.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE PURGE AIR AND LOSS OF PURGE ALARM TO MUD PUMP ALARM PANEL.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
PROVIDE PURGE AIR AND LOSS OF PURGE ALARM TO MUD PUMP CONTROLLER PANEL.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Electrical
Issued 27 November 1990 Resolved
REPLACE PHONE IN MUD PUMP ROOM WITH EXPLOSION PROOF TYPE WITH FITTED WITH SEALED FITTINGS.
Condition: Unknown
Due 27 November 1990
Resolved 27 November 1990
Engineering
Issued 13 November 1989 Resolved
MAKE PERMANENT REPAIRS TO THE FILL VALVES FOR THE DIESEL FUEL DAY TANK.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Engineering
Issued 13 November 1989 Resolved
REPAIR/REPLACE THE SECONDARY BILGE PUMP.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Electrical
Issued 13 November 1989 Resolved
REPAIR THE GENERATOR ALARM PANELS FOR #2 & #3 SS DIESEL GENERATORS.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Fire Fighting
Issued 13 November 1989 Resolved
RENEW OR REPLACE THE RUBBER EXPANSION JOINT IN THE FIREPUMP AND TEST THE NEW RELIEF VALVE.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Engineering
Issued 13 November 1989 Resolved
TEST LUBE OIL TRIPS ON #1-3 SSDG AND EMERGENCY GENERATOR.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Engineering
Issued 13 November 1989 Resolved
TEST HIGH JACKET WATER ALARMS ON ALL DIESEL GENERATOR SET.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Engineering
Issued 13 November 1989 Resolved
MAKE REPAIRS TO #1 SS DIESEL GENERATOR STARTING SOLENOID & TEST OVERSPEED TRIP.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Accommodation/Occupational Safety
Issued 13 November 1989 Resolved
REWIRE AND TEST THE REMOTE VENT. SHUTDOWN STATION LOCATED ON THE MAIN DECK.
Condition: Unknown
Due 13 November 1989
Resolved 13 November 1989
Fire Fighting
Issued 17 December 1988 Resolved
REPAIR OR REPLACE ONE INOPERATIVE O2/EXPLOSION METER FOR FIREMAN'S OUTFIT.
Condition: Unknown
Due 17 December 1988
Resolved 17 December 1988
Electrical
Issued 17 December 1988 Resolved
RENEW ALL DETERIORATED ARMORED ELECTRICAL CABLE AND PROVIDE PROPER EXPLOSION PROOF FITTINGS FOR LAGGING UNIT JUNCTION BOX IN SHALE SHAKER AREAMAIN DECK LEVEL.
Condition: Unknown
Due 17 December 1988
Resolved 17 December 1988
Fire Fighting
Issued 17 December 1988 Resolved
PROVIDE NEW FACE SHIELDS FOR BOTH FIREMAN'S OUTFITS PROXIMITY SUITS.
Condition: Unknown
Due 17 December 1988
Resolved 17 December 1988
Electrical
Issued 29 October 1987 Resolved
RENEW ALL DETIORATED ELECTRICAL ARMORED CABLE IN THE SHALE SHAKER AREA.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Lifesaving
Issued 29 October 1987 Resolved
PROVIDE FOLLOWING FOR #2 LIFEBOAT ; NINE ROCKET PARACHUTE FLARES, ONE SIXTYFOOT HEAVING LINE, 150 QUARTS WATER (3 QTRS./MAN X 50 MEN)
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Fire Fighting
Issued 29 October 1987 Resolved
PROVIDE THREE 100 FT. LENGTHS OF 1.5" FIREHOSE.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Lifesaving
Issued 29 October 1987 Resolved
PROVIDE 12 ADDITIONAL PFD'S.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Lifesaving
Issued 29 October 1987 Resolved
PROVIDE FOLLOWING FOR #1 LIFEBOAT; NINE ROCKET PARACHUTE FLARES, SEVEN HANDFLARES(RED), FIRST AID KIT, TWO 60 FT. HEAVING LINES, 150 QUARTS WATER (3 QTS/MAN X 50 MEN), NEW BATTERIES FOR FLASHLIGHT AND NEW SPARES.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Lifesaving
Issued 29 October 1987 Resolved
COMPLETE ALL ITEMS 1 THRU 23 ON C.G. THIS DATE.
Condition: Unknown
Due 29 October 1987
Resolved 29 October 1987
Lifesaving
Issued 1 April 1987 Resolved
TEST FIRE (AND LOG THE SAME) LINE THROWING APPLIANCE. ALSO PROVIDE 2 ADDITIONAL SERVICE LINES. COMPLIANCE DATE IS 01MAY87.
Condition: Unknown
Due 1 April 1987
Resolved 1 April 1987
Deck/Cargo
Issued 1 April 1987 Resolved
PROVIDE AUDIBLE ALARM ON FORK LIFT FOR ITS REVERSE OPERATION. COMPLIANCE DATE IS 01MAY87.
Condition: Unknown
Due 1 April 1987
Resolved 1 April 1987
Navigation
Issued 1 April 1987 Resolved
REPAIR INSTALLATION AND MAKE OPERABLE THE PORT ND STBD NAVIGATION RUNNING LIGHTS. COMPLIANCE DATE IS 01MAY87.
Condition: Unknown
Due 1 April 1987
Resolved 1 April 1987
Deck/Cargo
Issued 1 April 1987 Resolved
REPAIR OF REPLACE CLOGGED UP OR TORN FLAME SCREENS ON FUEL OIL TANK VENTS LOCATED BETWEEN NO. 3 AND NO. 4 BULD TANKS, MAIN DECK, STBD SIDE. COMPLIANCE DATE IS 01MAY87.
Condition: Unknown
Due 1 April 1987
Resolved 1 April 1987
Fire Fighting
Issued 1 April 1987 Resolved
SUBMIT COPY OF FOAM ANALYSIS REPORT. COMPLIANCE DATE IS 01MAY87.
Condition: Unknown
Due 1 April 1987
Resolved 1 April 1987
Accommodation/Occupational Safety
Issued 1 April 1987 Resolved
REPAIR TOILET IN 3RD DECK CHANGE ROOM. COMPLIANE DATE IS 01MAY87.
Condition: Unknown
Due 1 April 1987
Resolved 1 April 1987
Lifesaving
Issued 1 April 1987 Resolved
REPAIR ESCAPE LADDER ON BOW LEG (AFT AREA OF LEG) LADDER IS TORN UP AND DISCONTINUOUS AT APPROXIMATELY 80 FOOT LEVEL. COMPLIANCE DATE IS 01MAY87.
Condition: Unknown
Due 1 April 1987
Resolved 1 April 1987
Construction/Loadline
Issued 1 April 1987 Resolved
REMOVE ALL WATER IN THE VOID SPACES BENEATH THE MUD PITS. VOID SPACES TO BE CHECKED AFTER WATER IS REMOVED WHILE RIG IS JACKED OUT TO THE WATER AND NEXT TIME RIG IS FLOATING TO IDENTIFY WHERE WATER IS COMMING FROM. USCG TO BE NOTIFIED BY LETTER OF MONITORING OBSERVATIONS. COMPLY DATE IS 01MAY87
Condition: Unknown
Due 1 April 1987
Resolved 1 April 1987
Lifesaving
Issued 1 April 1987 Resolved
SUBMIT FOR APROVAL THE INSTALLATION OF THE 3 JACOB LADDERS ON RIG. COMPLIANCE DATE IS 01MAY87.
Condition: Unknown
Due 1 April 1987
Resolved 1 April 1987
Lifesaving
Issued 1 April 1987 Resolved
PROVIDE ONBOARD RIG FOLLOWING ADDITIONAL FIRST AID SUPPLIES: 15 TRIANGULAR BANDAGES, 3-4 INCH BANDAGE COMPRESSES, 2-2 INCH COMPRESSORS, BAND-AIDS, 1 RUBBER BLANKET OR EQUAL. COMPLIANCE DATE IS 01MAY87.
Condition: Unknown
Due 1 April 1987
Resolved 1 April 1987
Fire Fighting
Issued 1 April 1987 Resolved
REPAIR ROTATING ALARM LIGHT FOR THE LOSS OF MUD PIT VENTILATION LOCATED ON RIG FLOOR. COMPLIANCE DATE IS 01MAY87.
Condition: Unknown
Due 1 April 1987
Resolved 1 April 1987
Unknown
Issued 15 December 1985 Resolved
REPAIR/REPLACE 3 (40 PSI) RELIEF VALVES FOR P-TANKS AND 2 (125 PSI) RELIEF VALVES FOR AIR RECEIVERS. 46 CFR 54.15-10.
Condition: Unknown
Due 15 December 1985
Resolved 15 December 1985
Fire Fighting
Issued 15 December 1985 Resolved
HYDROSTATICALLY TEST OR REPLACE SURVIVAIR SCBA CYLINDERS IN FIREMEN'S OUT- FIT.
Condition: Unknown
Due 15 December 1985
Resolved 15 December 1985
Fire Fighting
Issued 15 December 1985 Resolved
PROVIDE DOCUMENTATION TO INDICATE THAT HELO DECK FOAM SYSTEM IS UL APPROVED.
Condition: Unknown
Due 15 December 1985
Resolved 15 December 1985
Fire Fighting
Issued 18 November 1985 Resolved
PROVIDE DOCUMENTATION TO INDICATE THAT THE HELO DECK FOAM SYSTEM HOSE IS ULAPPROVED.
Condition: Unknown
Due 18 November 1985
Resolved 18 November 1985
Fire Fighting
Issued 18 November 1985 Resolved
HYDROSTATICALLY TEST OR REPLACE SURVIVAIR SCBA CYLINDERS IN FIREMAN'S OUTFITS.
Condition: Unknown
Due 18 November 1985
Resolved 18 November 1985
Accommodation/Occupational Safety
Issued 18 November 1985 Resolved
INTERNALLY EXAMINE ALL PRESSURE VESSELS AND TEST RELIEF VALVES
Condition: Unknown
Due 18 November 1985
Resolved 18 November 1985
Accommodation/Occupational Safety
Issued 18 November 1985 Resolved
TEST BLOW OUT PREVENTER RELIEF VALVE.
Condition: Unknown
Due 18 November 1985
Resolved 18 November 1985
Fire Fighting
Issued 5 December 1984 Resolved
HYDROSTATICALLY TEST ALL CO2 BOTTLES 17 TOTAL WITHIN SEVEN (7) DAYS.
Condition: Unknown
Due 5 December 1984
Resolved 5 December 1984
Lifesaving
Issued 5 December 1984 Resolved
LAUNCH BOTH CAPSULES AND PERFORM OPERATIONAL TESTS IAW 46 CFR 109.217 AND PROVIDE PROOF OF SAME WITHIN THIRTY (30) DAYS.
Condition: Unknown
Due 5 December 1984
Resolved 5 December 1984
Documentation
Issued 5 December 1984 Resolved
RENEW CERTIFICATE OF DOCUMENTATION STICKER WITHIN THIRTY (30) DAYS.
Condition: Unknown
Due 5 December 1984
Resolved 5 December 1984
Fire Fighting
Issued 5 December 1984 Resolved
REPAIR OR REPLACE FIREMANS HOOD TO OUTFIT ON MAIN DECK WITHIN FOURTEEN (14)DAYS.
Condition: Unknown
Due 5 December 1984
Resolved 5 December 1984
Electrical
Issued 5 December 1984 Resolved
PROVIDE ADEQUATE HAZARD LOCATION PROTECTION FOR TELEPHONE LOCATED IN DOG HOUSE ADJACENT TO DRILLERS CONSOLE OR REMOVE FROM SERVICE WITHIN FOURTEEN (14) DAYS.
Condition: Unknown
Due 5 December 1984
Resolved 5 December 1984
Documentation
Issued 5 December 1984 Resolved
PROVIDE MASTER LOG AND MAINTAIN IAW 46 CFR 109.433 WITHIN FOURTEEN (14) DAYS.
Condition: Unknown
Due 5 December 1984
Resolved 5 December 1984
Fire Fighting
Issued 27 October 1983 Resolved
REPACK AND ADJUST PACKING GLAND ON FOAM STATION PUMP, RENEW OR REPAIR.
Condition: Unknown
Due 27 October 1983
Resolved 27 October 1983
Electrical
Issued 27 October 1983 Resolved
MAKE MAIN GENERATORS AVAILABLE FOR REVERSE POWER RELAY TEST.
Condition: Unknown
Due 27 October 1983
Resolved 27 October 1983
Fire Fighting
Issued 27 October 1983 Resolved
PROVIDE SAFETY CHAIN FOR ALL FIRE NOZZLES.
Condition: Unknown
Due 27 October 1983
Resolved 27 October 1983
Lifesaving
Issued 27 October 1983 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 27 October 1983
Resolved 27 October 1983
Lifesaving
Issued 27 October 1983 Resolved
NLT 31DEC83 HAVE ALL HIGH PRESSURE AIR BOTTLES HYDRO TESTED AND RECHARGE ON#1 AN #2 RESCUE CAPSULE.
Condition: Unknown
Due 27 October 1983
Resolved 27 October 1983
Lifesaving
Issued 27 October 1983 Resolved
#1 AND #2 RESCUE CAPSULES PROVIDE 100 CANS OF WATER, 100 CANS OF CONDENSED MILK.
Condition: Unknown
Due 27 October 1983
Resolved 27 October 1983
Fire Fighting
Issued 16 September 1982 Resolved
PROVIDE FIRE STATION EQUIPMENT FOR FRESH WATER STATION ON DRILL FLOOR TO PROVIDE TWO STATION COVERAGE.
Condition: Unknown
Due 16 September 1982
Resolved 16 September 1982
Engineering
Issued 16 September 1982 Resolved
MAKE AUXILIARY PROPULSION THRUSTERS AVAILABLE FOR CG-EXAM UPON COMPLETING REPAIRS TO EQUIPMENT.
Condition: Unknown
Due 16 September 1982
Resolved 16 September 1982
Documentation
Issued 16 September 1982 Resolved
PROVIDE APPROVED COPY OF HAZARDOUS LOCATION DRAWING.
Condition: Unknown
Due 16 September 1982
Resolved 16 September 1982
Unknown
Issued 5 May 1982 Resolved
SUBMIT PERMANENT REPAIR PROCEDURE FOR CRACKS IN CONNECTION PLATE FROM LEG TO CAN AT A & B CONNECTIONS.
Condition: Unknown
Due 5 May 1982
Resolved 5 May 1982

Ownership record