MAURY USCG vessel records
← All vessels

NRC PATRIOT II

NRC PATRIOT II is a 1981 oil recovery. The Coast Guard has recorded 17 inspections since 2016, most recently in January 2025, along with 28 deficiencies and 1 casualty investigation in 2013.

Records from 2013 to 2025. Most recent: inspection, 28 January 2025.

Built
1981
Last inspected
28 January 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 28 January 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8978502
WDA8587
Flag
UNITED STATES
Maury page id
psix-53385

Documentation record

Registered dimensions (L × B × D)97.2 ft × 26.0 ft × 6.7 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)100.8 ft × 26.0 ft × 11.6 ft
ITC tonnagegross 200 / net 60
BuilderOFFSHORE TRAWLERS INC · BAYOU LA BATRE, AL, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 December 2025 · expires 31 December 2026
Service, as the file records itOil Recovery
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
200 - Convention (Subpart B), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
60 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

28 January 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8060063
5 November 2024 Cargo Tank Internal · Deficiency Check · Drydock Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8016178
2 April 2024 Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7888820
9 January 2024 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7846966
9 January 2023 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7613116
29 December 2022 Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7614172
13 October 2022 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7562474
29 March 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7396365
22 March 2021 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7141929
16 October 2020 Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7074252
21 January 2020 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6884551
31 January 2019 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6607508
18 January 2018 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6337326
11 October 2017 Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6280417
1 June 2017 Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6248779
16 March 2017 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6102178
11 February 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5799608

Deficiency record · 28

09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 January 2024 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. Resupply first-aid kit to meet 160.041 and provide proof to USCG inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 February 2024
Resolved 2 April 2024
Resolution: First-aid kit was replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Other (mooring)
Issued 9 January 2024 Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. The ground tackle and mooring lines provided must be satisfactory for the size of the vessel, the waters on which the vessel operates, subject to the approval of the cognizant [name withheld] midship mooring cross bit had severe corrosion and holes in aft horizontal cross. Vessel is restricted from using this cross portion of the bit until it is repaired to the satisfaction of the OCMI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2024
Resolved 7 November 2024
Resolution: MI witnessed correction during Al Larson drydock.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 9 January 2023 Resolved
The owner shall, prior to receiving a Certificate of Inspection, submit for approval to the cognizant OCMI, at least two copies of the following plans, manuals, analyses, and calculations that are applicable to the vessel as determined by the OCMI:(6) Fire protection equipment installation including, but not limited to: (iii) Fire detecting system and smoke detecting system plans. Examination of fixed fire detection system installation showed that the installed step-up DC-DC converter was not consistent with the one approved in accordance with MSC letter E2-2203604 of November 25, 2022. Specifically, a different make/model was installed with a different output amperage. Amend plans and resubmit to MSC for approval or install approved step-up DC-DC converter.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2023
Resolved 10 February 2023
Resolution: MSC approved resubmitted plans for installation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 January 2023 Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of § 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. Newly installed fire detection ssytem was found powered with a portable power strip. Remove power strip. if necessary submit plans to install permanent connections.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2023
Resolved 12 January 2023
Resolution: Vessel removed power strip and connected power to existing receptacles.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 January 2023 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Station license on board vessel was expired. Provide valid station license.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 February 2023
Resolved 11 January 2023
Resolution: Vessel located and provided valid station license.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 29 March 2022 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Each vessel must carry a certificate with a valid endorsement while subject to the Bridge-to-Bridge Act.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2022
Resolved 7 April 2022
Resolution: Vessel provided valid certificate.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 29 March 2022 Resolved
On a vessel of more than 19.8 meters (65 feet) in length, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and all other spaces normally manned by crew members. Public address system is not audible in the galley or accomodation spaces. Provide public address system audible in all required spaces.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 April 2022
Resolved 7 April 2022
Resolution: Vessel demonstrated operational PA system for all spaces.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 29 March 2022 Resolved
On a vessel of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each normally unmanned spaces. Bilge high level alarm in pilothouse not functioning. Repair and demonstrate operation.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2022
Resolved 7 April 2022
Resolution: Vessel demonstrated properly functioning bilge high level alarm.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 March 2021 Resolved
Replace plastic sight glass with real glass.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2021
Resolved 16 April 2021
Resolution: Sightglass replaced.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 22 March 2021 Resolved
Provide FCC Bridge to Bridge Certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2021
Resolved 16 April 2021
Resolution: Certificate provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 21 January 2020 Resolved
Demonstrate watertight integrity of line way from forecastle to forepeak. Gasket found cracked and dog frozen.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2020
Resolved 3 February 2020
Resolution: Vessel refurbished gasket and repaired dog.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 21 January 2020 Resolved
Demonstrate vapor tight closure of engine room ventilation closures. Port side studs need replacement and both need gaskets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2020
Resolved 3 February 2020
Resolution: Vessel replaced studs and demonstrated ability to close.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 21 January 2020 Resolved
Provide current coast pilot, light list, charts, and tides/currents on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2020
Resolved 3 February 2020
Resolution: Vessel provided publications.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 21 January 2020 Resolved
Re-stencil emergency escape hatches.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2020
Resolved 3 February 2020
Resolution: Vessel re-stenciled both escape hatches.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 21 January 2020 Resolved
Provide smoke detectors that meet UL 217.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 February 2020
Resolved 3 February 2020
Resolution: Vessel provided documentation demonstrating that existing detectors meet UL 217.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 January 2019 Resolved
Provide 01 additional adult lifejacket for a total of 18; vessel restricted to 17 persons until corrected.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: Lifejacket provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 31 January 2019 Resolved
Prove proper operation of mast head and anchor light; restricted to daylight ops only.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: Nav lights operating properly.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 31 January 2019 Resolved
Provide Pipeline consortium letter, employee list, and MIS report.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 8 February 2019
Resolution: Documents received.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 31 January 2019 Resolved
Make deck hatch to E/R watertight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 8 February 2019
Resolution: Hatch is watertight.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 31 January 2019 Resolved
Replace wing nuts with standard nuts on batteries.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 8 February 2019
Resolution: Standard nuts installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 31 January 2019 Resolved
Replace volt meter on #1 genset.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 20 February 2019
Resolution: Volt meter replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 31 January 2019 Resolved
Re-mount dryer outlet cord to bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2019
Resolved 8 February 2019
Resolution: Outlet mounted.
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 April 2017 Resolved
Hard wire NAVTEX to electrical panel and prove proper operation; vessel restricted to 100nm from shore.
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 10 May 2017
Resolution: NAVTEX hard wired to panel and tested sat.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 11 April 2017 Resolved
Re-pack port shaft log.
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 10 May 2017
Resolution: Port shaft log repacked.
Deck/Cargo › Holds/Tanks › Watertight Door
Issued 11 April 2017 Resolved
Adjust dogs on main deck WTD to E/R by next drydock.
Action required: 705 - Other - as specified
Due 31 October 2017
Resolved 31 October 2017
Fire Fighting › Means of Escape › Doorways
Issued 11 April 2017 Resolved
Adjust emergency escape hatch from E/R to be opened from both sides.
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 10 May 2017
Resolution: Escape hatch properly adjusted.
Fire Fighting › Fire Pumps › Power Source
Issued 11 April 2017 Resolved
Label power switch for fire pump.
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 10 May 2017
Resolution: Fire pump switch labeled.
Communications › Radio Communications › EPIRB
Issued 11 April 2017 Resolved
Re-register EPIRB with NOAA with correct beacon ID#.
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 10 May 2017
Resolution: EPIRB registered with NOAA.

Casualty record · 1

28 August 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4699938
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.