Records from 1982 to 2005. Most recent: inspection, 16 May 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 73
16 May 2005
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2356762
7 February 2002
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1484912
28 November 2001
Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 772562
15 September 2000
Re-Inspection
Physical examination · Activities Europe · Activity 1362325
9 December 1999
COI Inspection · Hull Examination
Physical examination · Activities Europe · Activity 1418572
6 August 1998
Administrative
Administrative · Activities Europe · Activity 796260
23 July 1998
Deficiency Check
Physical examination · Activities Europe · Activity 795480
27 June 1998
Re-Inspection
Physical examination · Activities Europe · Activity 1462671
25 March 1998
Administrative
Administrative · Activities Europe · Activity 787179
3 October 1997
Plan Review "T" Boat
Administrative · Activities Europe · Activity 785372
13 August 1997
Administrative
Administrative · Activities Europe · Activity 1118565
25 July 1997
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1117719
10 July 1997
Administrative
Administrative · Activities Europe · Activity 779361
23 May 1997
Deadweight Survey · COI Inspection
Physical examination · Activities Europe · Activity 1368241
14 February 1997
Type not recorded
No type recorded · Activities Europe · Activity 1357893
11 September 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 954983
27 June 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1087409
28 May 1996
Deficiency Check · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1355835
22 March 1996
Deficiency Check · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1398431
26 January 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 879429
5 January 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1189086
27 October 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 877491
17 October 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1427129
19 June 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 878238
27 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1427047
22 March 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 960673
6 March 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 857040
18 November 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 869280
18 August 1994
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396164
7 January 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 851513
18 October 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1465763
22 April 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 833081
28 January 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 833629
16 December 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1139821
17 November 1992
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1132528
25 October 1992
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1472788
17 August 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1263554
15 May 1992
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 946998
7 March 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 948584
11 February 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1267216
14 November 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 938418
19 October 1991
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 935191
23 July 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 940361
10 May 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 908581
14 December 1990
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 927361
28 November 1990
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 901460
28 November 1990
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 922118
31 May 1990
Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239941
9 January 1990
Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 926696
26 December 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 901946
2 September 1989
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1209507
19 July 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1347903
26 May 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1347902
31 October 1988
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1201639
9 June 1988
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1200842
12 February 1988
Deficiency Check · Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1333191
25 August 1987
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1003500
30 December 1986
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013567
22 November 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1018270
22 November 1986
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1022913
7 August 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1011287
9 June 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303708
26 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290941
10 May 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1287744
12 April 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1286725
25 October 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1283564
11 April 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 974128
12 March 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 972865
17 May 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 971946
25 April 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 970309
20 April 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1273577
26 August 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 967272
7 March 1982
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 969703
Fire Fighting
Issued 15 September 2000
Resolved
Fire damper in the AC mechanical room in disrepair. Repair and prove proper operation.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Fire Fighting
Issued 15 September 2000
Resolved
Make all required fire dampers readily accessible
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 15 September 2000
Resolved
Verify accuracy of the fire control plan.
Condition: Unknown
Due 15 October 2000
Resolved 11 July 2005
Resolution: FCP verified.
Construction/Loadline
Issued 15 September 2000
Resolved
Properly secure the manhole cover in the dry stores.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Electrical
Issued 15 September 2000
Resolved
Replace missing covers for dry storeroom flourescent light fixtures.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Accommodation/Occupational Safety
Issued 15 September 2000
Resolved
Clean galley area under the deep fat fryer and area between deep fat fryer and oven.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Accommodation/Occupational Safety
Issued 15 September 2000
Resolved
REMOVE STORES FROM BERTHING COMPARTMENT 4A.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Accommodation/Occupational Safety
Issued 15 September 2000
Resolved
Provide light bulbs for open sockets and provide covers for open electric boxes room 8, and provide covers for open electric boxes room 7.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 15 September 2000
Resolved
Renew missing entry door handle for room 8 and repair loose entry door handle for room No. 9.
Condition: Unknown
Due 15 October 2000
Resolved 11 July 2005
Resolution: Handles for room 8 and 9 replaced.
Lifesaving › Lifeboat Equipment › Oar
Issued 15 September 2000
Resolved
Provide oars for life boats as required, provide hatchet, and life preservers._x001C_ _x001C_
Condition: Unknown
Due 15 October 2000
Resolved 11 July 2005
Resolution: Provided oars, hatchet and life preservers.
Fire Fighting
Issued 15 September 2000
Resolved
Broken and/or missing spanners at fire stations. Provide spanners at all fire stations.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Engineering
Issued 15 September 2000
Resolved
Test and stencil new oil transfer fuel hose in accordance with 33CFR 155.820
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Lifesaving
Issued 15 September 2000
Resolved
Restore line throwing gun storage container to watertight condition.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Fire Fighting › Fixed Gas Fire Extinguishing System › Control Valve
Issued 15 September 2000
Resolved
Properly label each cabinet or space that contains a valve, control or manifold of a fixed fire extinguishing system by one of the following: CARBON DIOXIDE FIRE APPARATUS", "FOAM FIRE APPARATUS" or WATER SPRAY APPARATUS fixed fire equipment IAW 46CFR 108.631.
Condition: Unknown
Due 15 October 2000
Resolved 11 July 2005
Resolution: Labeled spaces and cabinets.
Lifesaving
Issued 15 September 2000
Resolved
Renew all expired hospital medications.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Lifesaving
Issued 15 September 2000
Resolved
Water light past expiration date. Renew all expired water lights on life preservers with in date USCG approved lights
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Accommodation/Occupational Safety
Issued 15 September 2000
Resolved
Provide non-skid for helo deck IAW 46CFR 108.235.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 15 September 2000
Resolved
Vessel name changed. Properly label all lifesaving and fire fighting equipment etc. with the vessel's name as required.
Condition: Unknown
Due 15 October 2000
Resolved 11 July 2005
Resolution: Lifejackets and all other equipment labeled with rig name (THE 185).
Accommodation/Occupational Safety
Issued 15 September 2000
Resolved
Properly label all stateroom as to their service._x001C_
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Engineering › Generator (propulsion/auxiliary-electric) › Charger
Issued 15 September 2000
Resolved
Properly insulate emergency generator turbo charger IAW 46CFR 58.10-10.
Condition: Unknown
Due 15 October 2000
Resolved 11 July 2005
Resolution: Provided insulation for E. gen turbo charger.
Lifesaving
Issued 15 September 2000
Resolved
Provide proper seat belt for seat missing belt in the number one lifeboat.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Lifesaving
Issued 15 September 2000
Resolved
Mark the number of the lifeboat and name of the it on each life boat so that the markings are visible from above the boat.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Fire Fighting
Issued 15 September 2000
Resolved
Conduct fire and abandon ship drills prior to beginning operations. These drills are to be to the satisfaction of the attending USCG Marine Inspector.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Lifesaving
Issued 15 September 2000
Resolved
Recharge air bottles for lifeboats to required pressure._x001C_ _x001C_
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Lifesaving
Issued 15 September 2000
Resolved
Repair broken preventer for port lifeboat fall pulley located forward at deck level._x001C_ _x001C_
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Lifesaving
Issued 15 September 2000
Resolved
Renew all deteriorated retro-reflective tape on lifesaving equipment.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Lifesaving
Issued 15 September 2000
Resolved
Properly label life raft embarkation areas in accordance with 46CFR 108.647. The number of the raft and number of persons it is permitted to accommodate must be marked in a conspicuous place in the vicinity of the life raft.
Condition: Unknown
Due 15 September 2000
Resolved 15 September 2000
Lifesaving
Issued 9 December 1999
Resolved
END FOR END BOTH LIFERAFT DAVIT FALLS.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Deck/Cargo
Issued 9 December 1999
Resolved
RE-ALIGN/RENEW #3 PRELOAD DUMP VALVE SO THAT IT SEATS PROPERLY.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Lifesaving › Launching Appliances › Release Mechanism
Issued 9 December 1999
Resolved
Conduct onboard training in the use of davit launched liferafts including_x001C_ the inflation and lowering of the liferaft. Training to be completed priorto drilling operations and to the satisfaction of the attending USCG MarineInspector.
Condition: Unknown
Due 9 March 2000
Resolved 26 July 2006
Resolution: Cleared for admin. Rig reflagged.
Lifesaving
Issued 9 December 1999
Resolved
End to end port and starboard lifeboat falls and complete a 110% weight test of each davit prior to drilling operations and to the satisfaction of the attending USCG Marine Inspector.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Fire Fighting
Issued 9 December 1999
Resolved
DEMONSTRATE THE PROPER OPERATION OF THE VENTILATION SHUTDOWNS, TIME DELAYS,AND SIRENS FOR THE HALON FIXED FIRE EXTINGUISHING SYSTEMS PROTECTING THE MAIN GENERATOR ROOM AND EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Deck/Cargo
Issued 9 December 1999
Resolved
Complete quadrennial exam/testing of both cranes prior to drilling operations.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Construction/Loadline
Issued 9 December 1999
Resolved
Provide a copy of the underwater survey report including a copy of the video tape (NTSC format) and weld inspection report.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Fire Fighting
Issued 9 December 1999
Resolved
Make proper repairs to engineroom vent covers to provide a more effective seal prior to drilling operations and to the satisfaction of the attending USCG Marie Inspector.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Lifesaving
Issued 9 December 1999
Resolved
Conduct a fire and abandon ship drill prior to drilling operations and to the satisfaction of the attending USCG Marine Inspector.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Lifesaving
Issued 9 December 1999
Resolved
Complete full load weight test for port and starboard lifeboats including_x001C_ test of relieving gear prior to drilling operations and to the satisfactionof the attnding USCG Marine Inspector.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Lifesaving
Issued 9 December 1999
Resolved
Complete 110% weight test of port and starboard liferaft davits prior to drilling operations and to the satisfaction of the attending USCG Marine Inspector.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Fire Fighting
Issued 9 December 1999
Resolved
Prove proper operation of shutdowns, remote pulls, time delays, and sirens of the fixed halon systems prior to drilling operations and to the satisfaction of the attending USCG Marine Inspector.
Condition: Unknown
Due 9 December 1999
Resolved 9 December 1999
Lifesaving
Issued 9 December 1999
Resolved
COMPLY WITH 46 CFR 109.301 CONCERNING THE OPERATIONAL READINESS, MAINTENANCE, AND INSPECTION OF LIFESAVING EQUIPMENT.
Condition: Unknown
Due 31 December 1999
Resolved 14 December 1999
Lifesaving
Issued 9 December 1999
Resolved
LAUNCH/EXERCISE BOTH LIFEBOATS NO LESS THAN EVERY THREE MONTHS AND MAKE APPROPRIATE ENTRY INTO VESSEL'S LOG BOOK.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Lifesaving
Issued 9 December 1999
Resolved
CONDUCT ONBOARD TRAINING IN THE USE OF DAVIT LAUNCHED LIFERAFTS AT INTERVALS OF NOT MORE THAN FOUR MONTHS AND WHENEVER PRACTICABLE THIS MUST INCLUDE THE INFLATION AND LOWERING OF A LIFERAFT AND MAKE APPROPRIATE ENTRYINTO VESSEL'S LOG.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Lifesaving
Issued 9 December 1999
Resolved
CONDUCT A FIRE & ABANDON SHIP DRILL TO THE SATISFACTION OF THE ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Electrical
Issued 9 December 1999
Resolved
PROVIDE EMERGENCY COMMUNICATION IN REQUIRED LOCATIONS IN ACCORDANCE WITH 46CFR 113.30-3.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Documentation
Issued 9 December 1999
Resolved
PROVIDE VALID VESSEL DOCUMENTATION CERTIFICATE.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Construction/Loadline
Issued 9 December 1999
Resolved
PROVIDE UNDERWATER SURVEY PROPOSAL TO COGNIZANT OCMI FOR REVIEW.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Fire Fighting
Issued 9 December 1999
Resolved
PROVIDE VENT COVER FOR ENGINE ROOM VENTILATION DUCT LOCATED FORWARD OF THE HOUSE.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Fire Fighting
Issued 9 December 1999
Resolved
PROVIDE CO2 RELEASING MECHANISM FOR THE PAINT LOCKER.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Construction/Loadline
Issued 9 December 1999
Resolved
CONDUCT UNDERWATER SURVEY OF ALL SPUD CANS.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Construction/Loadline
Issued 9 December 1999
Resolved
PROVIDE FOR REVIEW HULL GAUGING REPORT.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Deck/Cargo
Issued 9 December 1999
Resolved
CLEAR/RENEW SUCTION VALVES & SOUNDING TUBES AS REQUIRED THROUGHOUT THE VESSEL. ENSURE STIKER PLATES ARE PROVIDED FOR ALL SOUNDING TUBES.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Deck/Cargo
Issued 9 December 1999
Resolved
RENEW THE DETERIORATED DRAIN PIPE LOCATED IN OVERHEAD OF EMERGENCY GENERATOR SPACE, ABOVE ELECTRICAL JUNCTION BOX (NUMEROUS PATCHES & SUSPECTED HOLES).
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Deck/Cargo
Issued 9 December 1999
Resolved
RENEW THE 2.5 INCHE PIPING IN OVERHEAD OF MUD PUMP ROOM (LEAKAGE INDICATED BY RUST STAINS).
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Deck/Cargo
Issued 9 December 1999
Resolved
RENEW THE DRILL WATER PUMP FOUNDATIONS IN THE MUD PUMP ROOM.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Documentation
Issued 9 December 1999
Resolved
PROVIDE ALL UPDATED 46 & 33 CODE OF FEDERAL REGULATIONS APPLICABLE TO THE VESSEL.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Electrical
Issued 9 December 1999
Resolved
CONDUCT TWO HOUR LOAD TEST OF EMERGENCY GENERATOR EVERY MONTH AND MAKE APPROPRIATE ENTRY INTO VESSEL'S LOG.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Lifesaving
Issued 9 December 1999
Resolved
CONDUCT LINE THROWING GUN TRAINING EVERY THREE MONTHS AND MAKE AN APPROPRIATE ENTRY INTO VESSEL'S LOG BOOK.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Electrical
Issued 9 December 1999
Resolved
CONDUCT TWO HOUR EMERGENCY BATTERY LOAD TEST EVERY SIX MONTHS AND RECORD THE RESULTS IN VESSEL'S LOG BOOK.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Documentation
Issued 9 December 1999
Resolved
PROVIDE ADDITIONAL INFORMATION ON WEEKLY DRILLS, i.e. RESULTS AND LESSONS LEARNED IN THE VESSEL'S LOG BOOK.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Lifesaving
Issued 9 December 1999
Resolved
CONDUCT LIFEBOAT WEIGHT TESTS FOR PORT & STARBOARD LIFEBOATS.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Lifesaving
Issued 9 December 1999
Resolved
CONDUCT LIFERAFT DAVIT WEIGHT TESTS FOR PORT & STARBOARD LIFERAFT DAVITS.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Lifesaving
Issued 9 December 1999
Resolved
PROVIDE SEA SICKNESS KIT FOR PORT & STARBOARD LIFEBOATS.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Deck/Cargo
Issued 9 December 1999
Resolved
REPLACE BROKEN GLASS FOR THE CLOSE CIRCUIT MONITOR IN THE DRILLER'S SHACK.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Deck/Cargo
Issued 9 December 1999
Resolved
PROVIDE BRACES FOR THE HYDRAULIC LINES ATTACHED TO BOTH CRANES.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Engineering
Issued 9 December 1999
Resolved
RENEW FLAME SCREENS FOR ALL FUEL VENTS.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Deck/Cargo
Issued 9 December 1999
Resolved
RENEW FLAME SCREENS FOR VENTS AS NEEDED THROUGHOUT THE VESSEL.
Condition: Unknown
Due 14 December 1999
Resolved 14 December 1999
Electrical
Issued 27 June 1998
Resolved
Conduct test of total rig shutdown securing all generators and ventilation.F ax statement from OIM to above office upon completion.
Condition: Unknown
Due 27 June 1998
Resolved 27 June 1998
Accommodation/Occupational Safety
Issued 23 May 1997
Resolved
Provide documentation from the OIM of proper repair to the starboard main deck bulk tank (renew piping from the bulk tank).
Condition: Unknown
Due 31 May 1997
Resolved 31 May 1997
Electrical
Issued 23 May 1997
Resolved
Provide documentation from the OIM of proper operation of the Total Rig Shutdown.
Condition: Unknown
Due 31 May 1997
Resolved 31 May 1997
Documentation
Issued 28 May 1996
Resolved
SUBMIT PLANS AND LIST OF MATERIALS FOR JACKHOUSE/QUARTERS RENOVATION TO [name withheld].
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Documentation
Issued 28 May 1996
Resolved
SUBMIT PLANS/CALCULATIONS FOR A NEW DEAD WEIGHT SURVEY DUE TO ADDED TOPSIDE(03 LEVEL) WEIGHTS TO MSC AND [name withheld].
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Lifesaving
Issued 28 May 1996
Resolved
WEIGHT TEST D/L LIFERAFT DAVIT AND FOUNDATION UPON INSTALLATION, ALSO SUBMIT PLANS AND SITE OF DAVIT LOCATION TO [name withheld].
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Documentation
Issued 28 May 1996
Resolved
SUBMIT COPY OF ABS SURVEY AND RIG MASTERS, INC. PLATE SUMMARY TO [name withheld].
Condition: Unknown
Due 28 May 1996
Resolved 28 May 1996
Unknown
Issued 17 October 1995
Resolved
Replace PV relief valve on drill floor.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Lifesaving
Issued 17 October 1995
Resolved
Prove operation of both enclosed lifeboat sprinkler pumps/systems in the presence of a marine inspector when rig is moved to Lake Maracaibo, VE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Electrical
Issued 17 October 1995
Resolved
Prove operation of emergency generator low oil pressure shutdown._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Lifesaving
Issued 17 October 1995
Resolved
Prove operation of the Rig Shutdown System in the presence of a marine inspector._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 November 1995
Resolved 27 October 1995
Electrical
Issued 17 October 1995
Resolved
Replace defective emergency switchboard Kilo watt meter._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Accommodation/Occupational Safety
Issued 17 October 1995
Resolved
Post copies of Hazardous Location Plans in areas visited by crew.
Condition: Unknown
Due 17 October 1995
Resolved 17 October 1995
Construction/Loadline
Issued 19 June 1995
Resolved
MAKE REPAIRS TO FRACTURES ON LEG TO CHORD CONNECTIONS AS NOTED IN TEXAS NDETECHNOLOGIES INSPECTION REPORT FROM UNDERWATER SURVEY OF 27APR95 AND CLIFFSDRILLING PROPOSAL DATED 22MAY95.
Condition: Unknown
Due 19 June 1995
Resolved 19 June 1995
Construction/Loadline
Issued 27 April 1995
Resolved
Submit proposal for repairs to [name withheld] for the repairs to chord and spud can connections. Proposal to include copy of ABS reccomendations,NDE report, video film of NDE, operational schedule, and any other pertinent data that may influence the OCMI's decision.
Condition: Unknown
Due 27 April 1995
Resolved 27 April 1995
Construction/Loadline
Issued 18 August 1994
Resolved
Submit repair proposal for inset in bow leg trunk. Damage is in chamfered slope at port aft corner of bottom plating in the forward leg trunk
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Engineering
Issued 18 August 1994
Resolved
Install method/fittings to adequately test low lube oil pressure shutdowns on all (4) main generators and (1) emergency generator.
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Construction/Loadline
Issued 18 August 1994
Resolved
Make permanent repairs to wastage of hull around overboard deck drain box stbd side outboard of leg. (Hull inserts must be 18" x 18" minimum, weldedboth sides._x001C_ _x001C_
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Accommodation/Occupational Safety
Issued 18 August 1994
Resolved
Submit detailed plans to OCMI for "new" drill floor air receiver that includes the information required by 46CFR54.01-5(d)(e).
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Construction/Loadline
Issued 18 August 1994
Resolved
Renew check valves in thru-hull drain lines in port and stbd #9 drill watertanks.
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Electrical
Issued 18 August 1994
Resolved
Make general repairs to electrical wiring/fixtures in shale shaker area including; cable trays, J-boxes, EYS and BICC fittings, motor controllers, etc.
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Lifesaving
Issued 18 August 1994
Resolved
Renew lifeboat davit falls for the port and starboard boats. (Last renewedon Aug87)
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Electrical
Issued 18 August 1994
Resolved
Prove proper operation of reverse power relay on #3 generator.
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Lifesaving
Issued 18 August 1994
Resolved
Make Mfg's authorized repairs to both lifeboats including: renew glass in windows, repair hatch seals and dogs, broken fiberglass at bow eye(#2 L/B) and various other repairs.
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Construction/Loadline
Issued 18 August 1994
Resolved
Complete underwater examination of Leg-to-Can welds, etc. of SEILODD (UWILD)
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Construction/Loadline
Issued 18 August 1994
Resolved
Submit repair proposal for renewal of wasted overhead deck longitudinals inthe artea over the mud pit room trough (ditch).
Condition: Unknown
Due 18 August 1994
Resolved 18 August 1994
Engineering
Issued 18 October 1993
Resolved
Install approved Pyrex sight glasses in sight tubes for S/S and Emergency Generator day tanks.
Condition: Unknown
Due 18 October 1993
Resolved 18 October 1993
Fire Fighting
Issued 25 October 1992
Resolved
RENEW PAINT LOCKER CO2 CYLINDER (BADLY WASTED), INSTALL OPERATING INSTRUCTIONS, PROVIDE EASILY ACCESSABLE QUICK ACTING VENT CLOSURES FOR SAME, LABLE AS CO2 SYSTEM VS HALON.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Fire Fighting
Issued 25 October 1992
Resolved
PROVIDE FOR BOTH FIREMAN'S SUITS; APPROVED 3-CELL FLASHLIGHTS WITH SPARE BATTERIES AND BULBS.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Engineering
Issued 25 October 1992
Resolved
PROVIDE DOCUMENTATION FROM CATERPILLAR MECHANICS SHOWING OVERSPEED, LOW LUBE OIL, AND HIGH WATER TEMPERATURE ALARMS/SHUTDOWNS ARE OPERATING PROPERLY AFTER OVERHAUL/MAINTENANCE.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Engineering
Issued 25 October 1992
Resolved
PROVIDE ASME APPROVED RELIEF VALVE FOR DRILL FLOOR AIR RECEIVER (MAWP 150 PSI).
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Documentation
Issued 25 October 1992
Resolved
PROVIDE ONBOARD PERSONNEL TO MEET REQUIRED MANNING AS SHOWN ON CERTIFICATE OF INSPECTION ( 2 ABs, 1 ORDINARY, 1 OFFSHORE INSTALLATION MANAGER, WHICH MUST INCLUDE 4 LIFEBOATMEN.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Lifesaving
Issued 25 October 1992
Resolved
PROVIDE THE FOLLOWING FOR LIFEBOAT #1: 13 LIFEBOAT RATIONS TO ALLOW 58 PERSONS; ONE POUND CONDENSED MILK OR SUBSTITUTE PROVISION (1400 CAL/PER) FOR EACH PERSON (58); FISHING KIT; THREE (3) 3-CELL FLASHLIGHTS WITH SPARE BATTERIES AND TWO SPARE BULBS FOR EACH; ONE JACKNIFE.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Documentation
Issued 25 October 1992
Resolved
PROVIDE COPY OF ABS LOADLINE CERTIFICATE CITING CURRENT STABILITY LETTER ISSUED FROM G-MSC LHI-00924 DTD 14DEC90.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Engineering
Issued 25 October 1992
Resolved
REPAIR OR REPLACE BULK AIR DRYER PRESSURE TANK.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Engineering
Issued 25 October 1992
Resolved
REPAIR OR PROVIDE DRIP PAN FOR OIL LEAK FROM DRAIN LINE ON EMERGENCY GENERATOR.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Electrical
Issued 25 October 1992
Resolved
PROVIDE BATTERY BOX FOR BATTERY AT COLD START ENGINE.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Fire Fighting
Issued 25 October 1992
Resolved
STRAIGHTEN INTAKE VENT LOUVER CHAIN LEVER FRONT OF CREW HOUSE (i.e. ENGINE ROOM SUPPLY.
Condition: Unknown
Due 25 November 1992
Resolved 9 November 1992
Electrical
Issued 25 October 1992
Resolved
INSTALL PROPER WIRING FROM THIRD PARTY INSTALLATION AT SHAKER AREA AND DRILL FLOOR. NON-APPROVED WIRE FOR HAZARDOUS LOCATIONS. (SCHLUMBERGER UNIT)
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Lifesaving
Issued 25 October 1992
Resolved
INSTALL BALL ON EYEWASH NOZZLE AND PROVE PROPER OPERATION OF EYEWASH STATION.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Accommodation/Occupational Safety
Issued 25 October 1992
Resolved
INSTALL PROPERLY RATED RELIEF VALVES (NOT OVER 100 PSI AND 210 DEGREES F) FOR HOT WATER HEATERS.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Lifesaving
Issued 25 October 1992
Resolved
PROVIDE THE FOLLOWING FOR LIFEBOAT #2: THREE (3) 3-CELL FLASHLIGHTS WITH SPARE BATTERIES AND TWO BULBS FOR EACH; ONE POUND CONDENSED MILK OR SUBSTITUTE PROVISIONS (1400 CAL) FOR EACH PERSON (58); MAKE PERMANENT REPAIRS TO HOLE IN L/B CANOPY; MAKE PERMANENT REPAIRS TO L/B EXHAUST.
Condition: Unknown
Due 25 October 1992
Resolved 25 October 1992
Construction/Loadline
Issued 17 August 1992
Resolved
PROVIDE TO [name withheld] A REPAIR PROPOSAL FOR, AND PROPERLY REPAIR FRACTURE IN CHORD "B", BOW LEG.
Condition: Unknown
Due 17 August 1992
Resolved 17 August 1992
Construction/Loadline
Issued 15 May 1992
Resolved
PROVIDE A COPY OF THE GAUGING REPORT OF 13MAY92.
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Construction/Loadline
Issued 15 May 1992
Resolved
MAKE AVAILABLE FOR INSPECTION LEG TO CAN CONNECTION AND SPUD CAN INTERNALS.
Condition: Unknown
Due 15 May 1992
Resolved 15 May 1992
Electrical
Issued 19 October 1991
Resolved
PROVE PROPER OPERATION OF LOSS OF VENTILATION TO MUD PITS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Accommodation/Occupational Safety
Issued 19 October 1991
Resolved
MAKE OPERATIONAL GENERAL ALARM BELLS LOCATED AT TOP OF PORT HOUSE ON AFT SIDE, ON SIDE OF VENT UNDER PIPE RACK CANTILEVER, AND CHECK PORT BELL IN PASSAGEWAY ON 3RD LEVEL OF QUATERS._x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Lifesaving
Issued 19 October 1991
Resolved
REPLACE MISSING FLOAT SMOKE SIGNALS FOR QUICK RELEASE RING BOUYS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Documentation
Issued 19 October 1991
Resolved
PROVIDE COAST GUARD APPROVAL LETTER FOR HAZARDOUS LOCATION PLAN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Accommodation/Occupational Safety
Issued 19 October 1991
Resolved
PROVIDE RELIEF VALVES FOR POTABLE WATER AND HOT WATER HEATERS WITH VALVES SET AT OR BELOW 100 PSI (NOT GREATER THAN MAWP) AND NOT MORE THAN 210 DEGREES F FOR WATER HEATERS, OR MAKE AVAILABLE FOR AN INTERNAL EXAMINATION. _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Accommodation/Occupational Safety
Issued 19 October 1991
Resolved
PROVIDE ASME APPROVED RELIEF VALVES, NOT TO EXCEED MAWP ON FOLLOWING PRESSURE VESSELS: #4 AND #6 BULK TANKS (NOT TO EXCEED 45 PSI), LOW PRESSUREAIR STORAGE, AND DRYER AIR RECEIVER._x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Lifesaving
Issued 19 October 1991
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Lifesaving
Issued 19 October 1991
Resolved
MAKE REPAIRS TO OR REPLACE EYEWASH STATION IN SACKROOM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Electrical
Issued 19 October 1991
Resolved
REMARK ALL EMERGENCY LIGHTS ON MAIN DECK WITH "E"._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Navigation
Issued 19 October 1991
Resolved
PROVIDE FOGHORN WITH INTERNATIONAL SIGNAL AND MAKE MANUAL CONTROL OPERABLE. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Unknown
Issued 19 October 1991
Resolved
PROVIDE AUTOMATIC SHUTOFF NOZZLE FOR LOGGING UNIT FUELING HOSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Electrical
Issued 19 October 1991
Resolved
PROVIDE EYS FITTINGS ON ALL LIGHTING UNDER CANTILEVER DECK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Lifesaving
Issued 19 October 1991
Resolved
MAKE BOTH LIFEFBOATS AVAILABLE FOR WEIGHT TEST AND OPERATIONAL TEST OF BOATS IN WATER TO INCLUDE TEST OF SPRINKLER SYSTEMS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Fire Fighting
Issued 19 October 1991
Resolved
PROVIDE HYDROSTATIC TEST OF HALON BOTTLE #74098 LAST TESTED 1/80._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Electrical
Issued 19 October 1991
Resolved
MAKE REPAIRS TO EMERGENCY GENERATOR TO OPERATE AUTOMATICALLY UPON LOSS OF MAIN POWER SUPPLY._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Lifesaving
Issued 19 October 1991
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Lifesaving
Issued 19 October 1991
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Documentation
Issued 19 October 1991
Resolved
PROVIDE APPROVAL FOR CHANGE OF ROUTE FOR OPERATION OUTSIDE THE GULF OF MEXICO._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Documentation
Issued 19 October 1991
Resolved
PROVIDE ABS LOADLINE CERTIFICATE WITH CURRENT STABILITY INFORMATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Fire Fighting
Issued 19 October 1991
Resolved
PROVIDE ONE (1) SPARE TWENTY (20) POUND PORTABLE FIRE EXTINGUISHER ON BOARD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Electrical
Issued 31 May 1990
Resolved
PROVIDE EXPLOSION PROOF GENERAL ALARM DRIVER WITH SEALED FITTING (CLASS I DIVISION II AREA) FOR UNIT LOCATED BENEATH PIPE RACK DECK STBD SIDE FORWARD
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Accommodation/Occupational Safety
Issued 31 May 1990
Resolved
PROVIDE EMERGENCY VENTILATION SHUT DOWN FOR QUARTERS AREA.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Electrical
Issued 31 May 1990
Resolved
PROVIDE SEALED FITTING WITH EXPLOSION PROOF ELBOW FOR"FLO-SHO" INDICATOR ON MUD RETURN LINE STBD SIDE BENEATH RIG FLOOR.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Electrical
Issued 31 May 1990
Resolved
POUR EYS FITTINGS ON MOORE TRANSDUCERS LOCATED STBD SIDE RIG FLOOR.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Electrical
Issued 31 May 1990
Resolved
INSTALL "SWACO" UNIT JUNCKION/SWITCH BOX IN ACCORDANCE WITH LABELED FACTORYMUTUAL SYSTEMS INSTRUCTIONS FOR CLASS I DIVISION II AREAS.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Electrical
Issued 31 May 1990
Resolved
PROPERLY MOUNT WIRING REPLACE WIRING RUN WITH "SCOTCH" SPLICE IN AREA OF DESANDER PUMPS.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Electrical
Issued 31 May 1990
Resolved
PROVIDE EXPLOSION PROOF DRIVER FOR SPEAKER IN MUD PITS.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Electrical
Issued 31 May 1990
Resolved
REPLCE MISSING BOLTS AND WING NUTS ON EXPLOSION PROOF LIGHTS IN MUD PITS.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Electrical
Issued 31 May 1990
Resolved
PROVIDE VISUAL OR AUDIBLE ALARM WHICH CAN BE READILY SEEN OR HEARD FOR GAS DETECTOR PANEL LOCATED IN DOG HOUSE(ALARM SHALL BE INSTALLED IN ACCORDANCE WITH NFPA 496).
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Electrical
Issued 31 May 1990
Resolved
PROVIDE PROPER INSTALLATION OF EXPLOSION PROOF BREAKER BOX LOCATED PORT SIDE AFT RIG FLOOR. AS PRESENTLY CONFIGURED INSTALLATION DOES NOT ALLOW FOR RESETTING UNLESS ENTIRE COVER IS REMOVED.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Construction/Loadline
Issued 2 September 1989
Resolved
PRESENT FOR COAST GUARD INSPECTION THE TOP & BOTTOM SURFACES OF THE BOW ANDSTBD SPUD CANS.
Condition: Unknown
Due 2 September 1989
Resolved 2 September 1989
Electrical
Issued 19 July 1989
Resolved
INSTALL A LOCK TO LOCK CLOSE THE SWITCH FOR THE GENERAL ALARM BATTERIES.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
INSTALL PLUGS IN THE OPEN CABLE HOLES ON THE JUNCTION BOXES ON THE DERRICK ABOVE THE WINDWALL PRIOR TO COMMENCING DRILLING.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
PROVE THAT THE APPLETON ELECTRICAL OUTLET BELOW THE SHALE SHAKER NEXT TO THE DOOR TO THE MACHINERY SPACES IN ACCEPTABLE FOR HAZARDOUS LOCATIONS. IF NOT, RENEW WITH AN OUTLET APPROVED FOR HAZARDOUS LOCATIONS PRIOR TO COMMENCING DRILLING.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
PROPERLY REPAIR SPLICED CABLE ON DRILLERS PHONE PRIOR TO COMMENCING DRILLING.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
REPAIR THE LOW LUBE OIL INDICATING LIGHT FOR THE #3 GENERATOR.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Deck/Cargo
Issued 19 July 1989
Resolved
INSTALL A BELT/PULLEY GUARD ON THE HYDRAULIC UNIT ON THE TOP OF THE LEG HOUSE ON THE STARBOARD AFT LEG.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
PROPERLY INSTALL THE ELECTRICAL CABLES ON THE JUNCTION BOX FOR #2 GENERATOR
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
INSTALL MISSING CAP ON GENERAL ALARM BATTERIES CELL AND WEDGE THE BATTERIESIN THE BOX.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Fire Fighting
Issued 19 July 1989
Resolved
PERFORM A SATISFACTORY FIRE DRILL IN THE PRESENCE OF A USCG MARINE INSP.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Fire Fighting
Issued 19 July 1989
Resolved
INSTALL RELIEF VALVES IN FIRE MAIN SYSTEM IAW 46CFR 108.417.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Unknown
Issued 19 July 1989
Resolved
CORRECT LOAD CELL ON STARBOARD CRANE.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Unknown
Issued 19 July 1989
Resolved
INSTALL BOOM ANGLE INDICATOR ON STARBOARD CRANE.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
INSTALL UL,FM OR CSA APPROVED LIGHT IN PAINT LOCKER GR C OR D ATMOSPHERE IAW NFC 500.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Documentation
Issued 19 July 1989
Resolved
POST INSTRUCTIONS FOR THE CO2 SYSTEM IN THE PAINT LOCKER (OPERATING INSTR.)
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Unknown
Issued 19 July 1989
Resolved
INSTALL REACH ROD OUTSIDE THE GENERATOR SPACE FOR THE DAYTANK.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Fire Fighting
Issued 19 July 1989
Resolved
REPLACE OR REPAIR FIRE STOP IN GENERATOR ROOM BULKHEAD TO BULK TANK ROOM.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Unknown
Issued 19 July 1989
Resolved
INSTALL HAND RAILS AROUND CATWALKS WHICH SURROUND THE GENERATOR PRIME MOVERS.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Unknown
Issued 19 July 1989
Resolved
INSTALL REMOTE REACH ROD OUTSIDE THE EMERGENCY GENERATOR ROOM TO SHUT THE FUEL OFF TO THE GENERATOR PRIME MOVER.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Lifesaving
Issued 19 July 1989
Resolved
REPLACE THE WINDOW (S) ON BOTH LIFE BOATS AROUND COXSWAIN FLAT. (WINDOWS THAT CAN'T BEE SEEN THROUGH).
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
INSTALL A BLANK IN THE 480 VOLT PANEL IN THE GALLEY.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
INSTALL ONE ADDITIONAL GENERAL ALARM BELL IN THE VICINITY OF THE AFT SIDE OF THE SHELL SHAKER TO COVER AFT AREAS ON RIG.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Construction/Loadline
Issued 19 July 1989
Resolved
REMOVE THE DOOR HOLD BACKS AND INSTALL POSITIVE DOOR CLOSURE DEVICES FOR THE MUDPIT DOORS PRIOR TO COMMENCING DRILLING.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
INSTALL AN APPROVED HAZARDOUS LOCATION JUNCTION BOX UNDER THE PORT SIDE AFTOF THE DRILL FLOOR (CATWALK) AND INSTALL WITH POURED EYS FITTINGS PRIOR TO COMMENCING DRILLING.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
RENEW THE ELECTRICAL CABLE AND REMOVE THE SMALLER ELECTRICAL CABLE FROM THEKICKPIPE PORTSIDE AFT OUTSIDE OF LIVING QUARTERS GOING THROUGH THE MAIN DECK.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
MAKE A PROPER END TO THE DEAD END CABLE COMING FROM THE JUNCTION BOX ON THEPORT SIDE OF THE MUDPIT AREA.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Fire Fighting
Issued 19 July 1989
Resolved
MAKE THE LARGE AND SMALL HALON DISCHARGE SIGNS AGREE WITH EACH OTHER AND BECORRECT WITH THE PROPER OPERATION OF THE SYSTEM BOTH GENERATOR AND EMERGENCY GENERATOR ROOM SYSTEM.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Deck/Cargo
Issued 19 July 1989
Resolved
REMOVE THE HANDS FREE CAPABILITY OF THE CRANE FUELING NOZZLES.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Lifesaving
Issued 19 July 1989
Resolved
REPAIR THE WATER LIGHT ON THE PORTSIDE AFTER RING BOUY AND RENEW THE RING BOUY.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
REPAIR THE EYS FITTING AND POUR IT FOR THE DRILL FLOOR BUG BLOWER CONTROLLER.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
INSTALL EYS FITTINGS AND POUR THEM FOR THE PUMP MOTOR IN THE BREEZE WAY BELOW THE SHALE SHAKER PRIOR TO THE COMMENCEMENT OF DRILLING OPERATIONS.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
SEPERATE THE WIRES AND POUR THE EYS FITTING FOR THE TANK LEVEL INDICATOR (MARTIN DECKER) ON TOP OF THE SHALE SHAKER HOUSE PRIOR TO COMMENCING DRILLING.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
INSTALL AND POUR EYS FITTING FOR THE P.A SPEAKER ABOVE THE SHALE SHAKERS. PRIOR TO COMMENCING DRILLING.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
INSTALL AND POUR EYS FITTINGS FOR THE HYDRAULIC PUMP UNIT ABOVE THE SHALE SHAKER AREA TO DF LEG HOUSE PRIOR TO COMMENCING DRILLING.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
REPAIR THE DEAD END CABLE ON THE DRILL FLOOR SWACO UNIT PRIOR TO COMMENCING DRILLING.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
INSTALL AND POUR EYS FITTING ON THE CAGED LIGHT ON THE PORT SIDE OF THE DRILL FLOOR PRIOR TO COMMENCING DRILLING.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
REPAIR MSA GAS DETECTOR PANEL ON DRILL FLOOR TO BE ABLE TO HOLD PURGE AND ALLOW FOR INDICATOR OF PURGE LOSS TO WORK PRIOR TO COMMENCING DRILLING OPERATIONS.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Electrical
Issued 19 July 1989
Resolved
INSTALL AN EYS FITTING ON THE STARBOARD SIDE OF THE WINDWALL AND POUR THE FITTING PRIOR TO COMMENCING DRILLING ON THE BUG BLOWER.
Condition: Unknown
Due 19 July 1989
Resolved 19 July 1989
Lifesaving
Issued 9 June 1988
Resolved
CONDUCT OPERATIONAL TEST OF PORT AND STARBOARD LIFEBOATS IN THE WATER.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Electrical
Issued 9 June 1988
Resolved
INSTALL EYS FITTINGS FOR GENERAL ALARM BELLS ON DRILL FLOOR AND IN MUD PIT ROOM.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Lifesaving
Issued 9 June 1988
Resolved
PROVIDE USCG, MESA OR MSHA APPROVED FIRST AID KIT FOR HOSPITAL SPACE.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Lifesaving
Issued 9 June 1988
Resolved
PROVIDE USCG APPROVED JACOBS LADDER.
Condition: Unknown
Due 9 June 1988
Resolved 9 June 1988
Unknown
Issued 12 February 1988
Resolved
ATTACH NAMEPLATE TO THE BULK AIR RECEIVER (24" DIAMETER, 2' 9" LONG, VER- TICAL TANK) THAT REFLECTS THE FOLLOWING INFORMATION; (1) MANUFACTURER'S NAME, (2) SERIAL NUMBER, (3) MAX. ALLOWABLE WORKING PRESSURE (600PSI @ 650 DEG F.), AND LEAVE SPACE FOR THE CG PROPELLER STAMP.
Condition: Unknown
Due 12 February 1988
Resolved 12 February 1988
Unknown
Issued 25 August 1987
Resolved
PROVIDE MANUFACTURER'S DATA PLATE INFORMATION ON THE BULK AIR RECEIVER.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Unknown
Issued 25 August 1987
Resolved
REMOVE OR REPAIR AND TEST THE FIRE DETECTION SYSTEM.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Unknown
Issued 25 August 1987
Resolved
PROPERLY STOW THE LINE FOR THE RING BUOY LOCATED BEHIND THE STBD JACK HOUSE
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Unknown
Issued 25 August 1987
Resolved
POUR THE EYS FITTINGS AND REPLACE THE BROKEN LIGHT GUARD ON THE DRILL FLOORPRIOR TO CONDUCTING DRILLING OPERATIONS.
Condition: Unknown
Due 25 August 1987
Resolved 25 August 1987
Documentation
Issued 9 June 1986
Resolved
PROVIDE A VALID CERTIFICATE OF DOCUMENTATION ON THE RIG. COMPLIANCE DATE IS09JUL86.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Documentation
Issued 9 June 1986
Resolved
PROVIDE A COAST GUARD APPROVED FIRE CONTROL PLAN ON THE RIG. COMPLIANCE DATE IS 09JUL86.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Construction/Loadline
Issued 9 June 1986
Resolved
PROVIDE EVIDENCE OF COAST GUARD APPROVAL FOR THE CONSTRUCTION PORTFOLIO. COMPLIANCE DATE IS 09JUL86.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Construction/Loadline
Issued 9 June 1986
Resolved
REPAIR ALL INOPERABLE OR MISSING DOGS ON WATERTIGHT CLOSURES TO PRELOAD AND VOID TANKS. COMPLIANCE DATE IS 09JUL86.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Navigation
Issued 9 June 1986
Resolved
REMOVE THE ALL-ROUND WHITE LIGHT LOCATED NEAR THE STERN LIGHT. COMPLIANCE DATE IS 09JUL86.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Electrical
Issued 9 June 1986
Resolved
REMOVE THE DEAD ENDED CABLE, PORTSIDE BULKHEAD AFT, DRILL FLOOR AND REPAIR OR REMOVE THE WATER COOLER. COMPLIANCE DATE IS 09JUL86.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Accommodation/Occupational Safety
Issued 9 June 1986
Resolved
PROVIDE CLOSURE DEVICES FOR THE VENTS TO THE PAINT LOCKER. COMPLIANCE DATEIS 09JUL86.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Lifesaving
Issued 9 June 1986
Resolved
PROVIDE OPERABLE LIGHTS AND WHISTLES ON LIFE PRESERVERS AS REQUIRED. LIGHTSTO BE SECURED TO FRONT SHOULDER AREA. COMPLIANCE DATE IS 09JUL86.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Deck/Cargo
Issued 9 June 1986
Resolved
CLEAN UP CAB AREAS AND STANDING OIL IN VICINITY OF THE PORT AND STBD CRANESCOMPLIANCE DATE IS 09JUL86.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Fire Fighting
Issued 9 June 1986
Resolved
PROVIDE APPROVAL AND LABELLING FOR, OR REMOVE THE TWO CO2 EXTINGUISHERS SERVICING THE HELO DECK. COMPLIANCE DATE IS 09JUL86.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Navigation
Issued 9 June 1986
Resolved
CLEAN ALL NAVIGATION AND OBSTRUCTION LIGHT LENSES. COMPLIANCE DATE IS 09JUL86.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Electrical
Issued 9 June 1986
Resolved
PROVIDE REMOTE SHUTDOWN CONTROL FOR THE FUEL OIL TRANSFER PUMP. DEMONSTRATEIN PRESENCE OF COAST GUARD. COMPLIANCE DATE IS 09JUL86.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Navigation
Issued 9 June 1986
Resolved
MAKE OPERABLE THE UPPERMOST RED MASTHEAD LIGHT. COMPLIANCE DATE IS 09JUL86.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Electrical
Issued 9 June 1986
Resolved
MAKE OPERABLE THE AUTOMATIC BUS TRANSFER AND DEMONSTRATE IN PRESENCE OF COAST GUARD. COMPLIANCE DATE IS 09JUL86
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Electrical
Issued 9 June 1986
Resolved
INSTALL EMERGENCY LIGHTING IN THE MUD PIT ROOM. COMPLIANCE DATE IS 09JUL86
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Construction/Loadline
Issued 9 June 1986
Resolved
REPAINT THE VESSEL NAME AND HAILING PORT ON THE STERN. COMPLIANCE DATE IS 09JUL86.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Navigation
Issued 9 June 1986
Resolved
PROVIDE ONE ADDITIONAL BLACK BALL DAY SHAPE. COMPLIANCE DATE IS 09JUL86.
Condition: Unknown
Due 9 June 1986
Resolved 9 June 1986
Lifesaving
Issued 12 April 1985
Resolved
PROVIDE 500 FEET OF AUXILIARY LINE FOR THE LINE THROWING GUN.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Lifesaving
Issued 12 April 1985
Resolved
SUPPLY THE PORT SIDE AFTER RING BUOY WITH A SERVICEABLE SMOKE SIGNAL.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Fire Fighting
Issued 12 April 1985
Resolved
REPLACE THE NOZZLE ON THE STARBOARD HELIPORT CO2 FIRE EXTINGUISHER.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Deck/Cargo
Issued 12 April 1985
Resolved
REPAIR THE DISTORTED CROSS MEMBERS ON THE STARBOARD CRANE BOOM AT THE TWENTY FOOT LEVEL PRIOR TO USING AND CONDUCT WEIGHT TESTS ON THE REPAIRED BOOM.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Fire Fighting
Issued 12 April 1985
Resolved
SERVICE THE OXYGEN METER FOR THE FIREMAN'S OUTFIT WHICH IS STORED IN THE P-TANK ROOM.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Deck/Cargo
Issued 12 April 1985
Resolved
INSTALL THE NEW BOOM LIGHTS ON BOTH CRANES.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Accommodation/Occupational Safety
Issued 12 April 1985
Resolved
INSTALL A RELIEF VALVE ON THE AIR DRYER (PRESSURE VESSEL) IN THE HALLIBURTON ROOM TO RELIEVE AT 125 PSIG OR BELOW.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Accommodation/Occupational Safety
Issued 12 April 1985
Resolved
REPLACE OR REPAIR ALL SIX P-TANK RELIEF VALVES AND TEST IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Accommodation/Occupational Safety
Issued 12 April 1985
Resolved
PROVIDE DOCUMENTATION THAT THE BULK AIR COMPRESSOR AIR RECIEVER IS ASME APPROVED AND SHOW THAT THE MAXIMUM ALLOWABLE WORKING PRESSURE (MAWP) IS NOT LESS THAN 90 PSIG.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Documentation
Issued 12 April 1985
Resolved
SUBMIT THE CONSTRUCTION PORTFOLIO TO [name withheld] EIGHT (MMT), ROOM 845, F. EDWARD HEBERT BUILDING, 600 S. MAESTRI ST., NEW ORLEANS, LOUISIANA, FOR APPROVAL OR SHOW THAT THE VESSEL HAS A COAST GUARD APPROVED PORTFOLIO.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Lifesaving
Issued 12 April 1985
Resolved
CONDUCT A FIRE AND AN ABANDON RIG DRILL PRIOR TO DRILLING.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Lifesaving
Issued 12 April 1985
Resolved
CONDUCT OPERATIONAL TESTS OF BOTH LIFEBOATS AND DAVITS.
Condition: Unknown
Due 12 April 1985
Resolved 12 April 1985
Lifesaving
Issued 12 March 1984
Resolved
CONDUCT WEIGHT TEST ON (2) TWO LIFE CAPSULES.
Condition: Unknown
Due 12 March 1984
Resolved 12 March 1984