MAURY USCG vessel records Sign in
← All vessels

CAPT. JASON

CAPT. JASON is a 1981 passenger vessel (inspected). The Coast Guard has recorded 73 inspections since 1981, most recently in July 2022, along with 96 deficiencies, 2 operational controls and 2 casualty investigations between 2007 and 2010.

Records from 1981 to 2022. Most recent: inspection, 15 July 2022.

Built
1981
Last inspected
15 July 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD6340
Flag
UNITED STATES
367171590
Maury page id
psix-53397

Inspections, by type

…with no type recorded19
Years with a record 38 calendar years (1981–2022)
The 73 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD6340MMSI 367171590 · active · compulsorily equipped · granted 4 January 2017, expires 8 March 2027
WRA4700MMSI not assigned · expired · compulsorily equipped · granted 21 June 1996, cancelled 18 November 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

MR. MASON Passenger (Inspected) · MISLE 461238 · 21 February 1998 · activity 95301

Inspection history · 73

15 July 2022 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7507671
8 December 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7108402
29 January 2019 Examination of Repairs · Drydock Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6616687
12 August 2018 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6514867
31 August 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6251232
18 May 2016 Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5873725
18 February 2016 Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5802799
12 August 2015 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5219931
24 June 2014 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4898501
2 February 2012 Drydock Exam · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4234509
22 March 2010 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3810116
26 January 2010 Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3669383
10 April 2008 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3181467
31 March 2008 Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3174778
3 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3175991
28 September 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3068267
27 September 2007 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3068128
27 April 2007 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2917050
5 March 2007 Damage Survey · Examination of Repairs · Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2882359
5 March 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2889077
21 July 2006 Hull Examination · Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2720172
3 May 2006 COI Inspection · Ballast Water Examination · Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2639668
26 October 2005 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2521851
3 November 2004 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2230794
30 August 2004 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2180915
27 October 2003 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1937841
20 September 2002 COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1678082
12 October 2001 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1389495
18 February 2001 Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 1521651
28 September 2000 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1369852
26 June 2000 Type not recorded
No type recorded · Station Freeport · USCG Heartland District (CGD-H) · Activity 1516226
7 February 2000 Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1401179
4 November 1999 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 804678
14 October 1999 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1463525
16 October 1998 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465995
21 February 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 95301
12 December 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464071
17 October 1996 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 845098
15 October 1996 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1413061
21 May 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1085596
13 October 1995 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1363402
2 October 1995 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1439652
27 October 1994 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1396200
10 October 1994 COI Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1464543
21 October 1993 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 643509
18 October 1993 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1153357
16 October 1993 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 38274
16 October 1993 Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 837383
5 October 1993 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1419168
9 October 1992 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 939912
13 December 1991 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 948286
5 November 1991 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1248393
22 May 1991 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1214047
6 November 1990 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1221376
7 November 1989 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1239594
25 September 1989 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1209439
18 September 1989 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 891645
18 September 1989 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1350904
25 October 1988 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 889231
20 September 1988 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1194844
22 April 1988 Drydock Extension
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1044700
13 October 1987 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1018848
13 October 1986 COI Inspection · Credit Drydock
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1012023
2 June 1986 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1298283
22 April 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1297893
1 November 1985 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1297235
1 October 1985 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 994588
13 December 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 977196
4 October 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1282187
27 October 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1279047
22 April 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1278486
25 October 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1272610
26 October 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967071

Deficiency record · 96

Construction/Loadline › Hull › Weld
Issued 31 August 2017 Resolved
Repair port steering rudder stop.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 11 September 2017
Resolution: Recieved photographic documentation attesting to correction of deficiencies to satisfaction of Marine Inspector.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 31 August 2017 Resolved
2nd operator on board must provide marine operator's permit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 11 September 2017
Resolution: Recieved photographic documentation attesting to correction of deficiencies to satisfaction of Marine Inspector.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 31 August 2017 Resolved
Install B-II currently located in galley closet in a proper bracket in galley space outside closet.
Action required: 705 - Other - as specified
Due 14 September 2017
Resolved 11 September 2017
Resolution: Recieved photographic documentation attesting to correction of deficiencies to satisfaction of Marine Inspector.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 18 May 2016 Resolved
Watertight door indicator for gen room door not operaable.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2016
Resolved 18 May 2016
Resolution: Bulb was replaced and electrical connection repaired.
Engineering › Bilge Water Management System › Valve
Issued 18 May 2016 Resolved
Bilge pump could not take suction from forepeak
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2016
Resolved 18 May 2016
Resolution: check valve in forepeak line replaced and operational.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 12 August 2015 Resolved
Ventilation shutdown from the operating station did not work. Crew ordered new switch.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 August 2015
Resolved 13 August 2015
Resolution: New switch ordered, installled, and tested by crew sat.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 12 August 2015 Resolved
Paint locker did not contain a vent. Pipe leading out of the space was capped off.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 August 2015
Resolved 13 August 2015
Resolution: Vent installed.
Lifesaving › Lifefloat › Painter
Issued 12 August 2015 Resolved
Painter line in between each lifefloat was too short to allow each float to reach water without binding the next one on the cradle. Crew to lengthen line to allow ease of deployment.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2015
Resolution: Adequate length painter line installed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 September 2007 Resolved
Vessel Operator failed to make vessel available for inspection within 3 months before or after anniversary date of COI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 September 2007
Resolution: Vessel was made available for inspection 6 weeks after 90 day window.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 27 September 2007 Resolved
Provide emergency lighting in forward passenger area for escape hatch.
Action required: 705 - Other - as specified
Due 27 October 2007
Resolved 3 March 2008
Engineering › Fuel Oil Service System › Piping
Issued 27 September 2007 Resolved
Renew compression fittings on copper fuel lines
Action required: 705 - Other - as specified
Due 27 October 2007
Resolved 3 March 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 27 September 2007 Resolved
Provide fixed fire extinguisher system for paint locker
Action required: 705 - Other - as specified
Due 27 October 2007
Resolved 3 March 2008
Electrical › Lighting (service) › Outlet Box
Issued 27 September 2007 Resolved
Remove all electrical outlet expansion plugs on bridge and in galley.
Action required: 705 - Other - as specified
Due 27 October 2007
Resolved 3 March 2008
Lifesaving › Lifefloat › Serviceable
Issued 27 September 2007 Resolved
Renew two 12 person lifefloats on vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 September 2007
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 19 March 2007 Resolved
Vessel was underway without a licnesed mate as required by vessel's COI
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2007
Resolved 21 March 2007
Operations/Management › Port and Waterways Safety › Notice of Hazardous Condition
Issued 19 March 2007 Resolved
Vessel was operating in a commercial setting without being in full compliance with the vessel COI in that the vessel had not corrected any of the 26 no-sail CG-835's issued by the marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2007
Construction/Loadline › Hull › Side Shell
Issued 15 March 2007 Resolved
C/R 18" X 18" insert in stbd rudder room
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Fire Fighting › Means of Escape › Emergency Lighting
Issued 15 March 2007 Resolved
Demonstrate proper emergency lighting for marine inspector
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Fire Fighting › Combustible Materials › Grounds
Issued 15 March 2007 Resolved
Remove fan & drop lighting from E/R
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 15 March 2007 Resolved
Remove flammable maintenence supplies from generator space
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 15 March 2007 Resolved
Clean all generator armatures
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 15 March 2007 Resolved
Double nut both shafts
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Lifesaving › Lifefloat › Painter
Issued 15 March 2007 Resolved
Resplice painter so lifefloats are not secured to the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Fire Fighting › Means of Escape › Escape Route Signs
Issued 15 March 2007 Resolved
Adjust and properly label fwd emergency escape hatch
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 March 2007 Resolved
Place machinery guard over sewage pump
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Stability › Watertight Integrity › General
Issued 15 March 2007 Resolved
Renew portside wire penetrations and ensure they are watertight and port generator space bulkhead
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 15 March 2007 Resolved
Lock sewage valve when in port.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 15 March 2007 Resolved
Install marine grade junction box in galley bilge area
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 15 March 2007 Resolved
Remount loose junction box and alarm box over port engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Engineering › Fuel Oil Service System › Piping
Issued 15 March 2007 Resolved
Repair leaking fuel return line on stbd engine and repair gate valve leak on same system.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Engineering › Fuel Oil Service System › Hose
Issued 15 March 2007 Resolved
Install marine grade fuel hose on fuel trap
Action required: 17 - Rectify deficiencies prior to departure
Due 21 March 2007
Resolved 21 March 2007
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 15 March 2007 Resolved
Adjust mounting for slop oil tank
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 15 March 2007 Resolved
Renew all flame screens on fuel tank vents
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 15 March 2007 Resolved
Label all electrical circuit breakers in vessel
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Stability › Weathertight Integrity › General
Issued 15 March 2007 Resolved
Repair leak on portside fwd cabin window.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 5 March 2007 Resolved
Remove all oil from bilge and provide receipt to marine inspector
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2007
Fire Fighting › Combustible Materials › Insulation
Issued 5 March 2007 Resolved
Remove all fire damaged equipment from E/R and renew to original
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 5 March 2007 Resolved
Recharge all fire fighting equipment used in fire.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 March 2007
Engineering › Bilge Water Management System › Piping
Issued 5 March 2007 Resolved
Verify gray water piping integrity and remove water from fwd bilge space. Also remove flammable liquids from space and stroe properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 5 March 2007 Resolved
Label stove disconnect at stove
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Construction/Loadline › Structures › Door
Issued 5 March 2007 Resolved
Adjust all E/R doors
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Operations/Management › Pollution › Retention of Oily Mixture
Issued 5 March 2007 Resolved
Remove all waste oil from generator space bilge
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Personnel › Certificates/Documents/Licenses › License, Master
Issued 3 May 2006 Resolved
Found vsl operating without proper licensed persons onboard. Issued NOV for Failure to have a licensed master on inspected small passenger vsl. Removed Vsl COI.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2006
Resolved 10 May 2006
Resolution: Returned COI
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 3 May 2006 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 17 May 2006
Resolved 10 May 2006
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 3 May 2006 Resolved
Vsl found with open sewage valves one of which was locked in the open position. Issued NOV: Failure to secure each type III MSD prior to operating vsl in an area where the discharge of untreated sewage is prohibited by EPA.
Due 3 May 2006
Resolved 3 May 2006
Resolution: Valves sucured.
Stability › Watertight Integrity › General
Issued 3 May 2006 Resolved
Below deck watertight doors lack maintenance, need adjusting, fittings are worn.
Action required: 705 - Other - as specified
Due 4 June 2006
Resolved 10 May 2006
Construction/Loadline › Structures › Scuttle
Issued 3 May 2006 Resolved
Passenger space emergency escape hatch will not open. Provide for proper operation.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2006
Resolved 10 May 2006
Navigation › Piloting/Steering › Marine Charts
Issued 3 May 2006 Resolved
Provide marine charts-updated for areas of operation and updated required publication.
Due 3 June 2006
Resolved 10 May 2006
Engineering › Steering Gear System › Pump
Issued 3 May 2006 Resolved
Provide proper operation of both steering pumps.
Due 3 June 2006
Resolved 10 May 2006
Engineering › Bilge Water Management System › Pump
Issued 3 May 2006 Resolved
Provide two working bilge pumps as required.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 May 2006
Resolved 10 May 2006
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 3 May 2006 Resolved
Provide Ballast water management plan as required.
Action required: 705 - Other - as specified
Due 3 June 2006
Resolved 25 July 2006
Resolution: The vessel has a ballast water management plan despite not needing one. The vessel does transit in between different COTP zones but does not take on ballast water.
Lifesaving › Lifefloat › Painter
Issued 3 November 2004 Resolved
Renew starboard side lifefloats seapainter.
Condition: Improper/Lack of Maintenance
Due 17 November 2004
Resolved 17 November 2004
Resolution: Seapainter replaced.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 3 November 2004 Resolved
Renew/replace corroded hinges on ER vent closures.
Condition: Improper/Lack of Maintenance
Due 17 November 2004
Resolved 10 November 2004
Resolution: Hinges replaced.
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 3 November 2004 Resolved
Repair low lube oil warning light on alarm panel on bridge for port MDE and prove proper operation.
Condition: Unknown
Due 17 November 2004
Resolved 10 November 2004
Resolution: Warning light repaired.
Fire Fighting › Fire Pumps › Gland Sealing
Issued 3 November 2004 Resolved
Renew seal on fire pump to stop excessive leakage.
Condition: Improper/Lack of Maintenance
Due 17 November 2004
Resolved 10 November 2004
Resolution: Pump replaced.
Electrical › Electric Supply System (service) › Battery Installation
Issued 3 November 2004 Resolved
Replace battery box in generator room due to being holed/damaged.
Condition: Damaged By Earlier Event
Due 17 November 2004
Resolved 10 November 2004
Resolution: Battery box replaced.
Lifesaving › Buoyant Apparatus
Issued 27 October 2003 Resolved
MAKE PERMANENT REPAIRS TO (2) PUNCTURED BUOYANT APPPARATUS.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 December 2003
Electrical
Issued 12 October 2001 Resolved
REMOVE UNUSED BARE ENDED ELECTRICAL WIRING FROM PORT SIDE OF CREW QUARTERS PASSAGE WAY BILGE.
Condition: Unknown
Due 12 October 2001
Resolved 5 December 2001
Construction/Loadline
Issued 12 October 2001 Resolved
REWELD MARKED FRACTURES: 6 WELDS IN FWD PASSAGE WAY BILGE COMPARTMENT, 3 INAIR HANDLER BILGE COMPARTMENT, 6 IN LAZERETTE.
Condition: Unknown
Due 12 October 2001
Resolved 5 December 2001
Lifesaving
Issued 12 October 2001 Resolved
PROVIDE COPY OF EPIRB REGISTRATION.
Condition: Unknown
Due 12 October 2001
Resolved 5 December 2001
Fire Fighting
Issued 12 October 2001 Resolved
REWORK STARBOARD MAIN DECK ENGINE ROOM FIRE DAMPERS - PROVE SATISFACTORY FIT UP.
Condition: Unknown
Due 12 October 2001
Resolved 5 December 2001
Lifesaving
Issued 12 October 2001 Resolved
RENEW EXPIRED COMPONENTS OF 1ST AID KIT - ASPIRINAND STERILE EYEWASH SOLUTION.
Condition: Unknown
Due 12 October 2001
Resolved 5 December 2001
Navigation
Issued 14 October 1999 Resolved
Provide new/updated tide tables, current tables, and charts of area transited. Pubs used on board were 97 issue.
Condition: Unknown
Due 14 October 1999
Resolved 14 October 1999
Navigation
Issued 14 October 1999 Resolved
Provide and post updated compass deviation table.
Condition: Unknown
Due 14 October 1999
Resolved 14 October 1999
Construction/Loadline
Issued 14 October 1999 Resolved
Repair crack in weld in way of 2nd bulkhead frame, located starboard side aft.
Condition: Unknown
Due 14 October 1999
Resolved 14 October 1999
Lifesaving
Issued 14 October 1999 Resolved
Renew/Replace batteries in life jacket lights for all 60 life jackets. Batteries expire 11/99.
Condition: Unknown
Due 14 October 1999
Resolved 14 October 1999
Construction/Loadline
Issued 12 December 1997 Resolved
1. REAPAIR FRACTURED WELD IN THE SIDESHELL AT BASE OF #1 SSDG EXHAUST _x001C_ PIPE.
Condition: Unknown
Due 12 December 1997
Resolved 18 December 1997
Construction/Loadline
Issued 2 October 1995 Resolved
MAKE PERMANT REPAIR TO VENT FLAPS. (NATURAL VENTLATION FOR ENGINE AND GENERATOR ROOMS VENT CLOSURES HAVE A FEW PIN HOLES )
Condition: Unknown
Due 1 November 1995
Resolved 26 October 1995
Documentation
Issued 2 October 1995 Resolved
FILL OUT AND RETURN FORM B OF THE CHEMICAL TESTING PROGRAM AUDIT.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Engineering
Issued 2 October 1995 Resolved
MAKE PERMANT REPAIR TO SALT WATER DISCHARGE PIPE ON THE STARBOARD INBOARD ENGINE. (TEMP. REPAIR TO PIN HOLES IN PIPE DONE)
Condition: Unknown
Due 1 November 1995
Resolved 26 October 1995
Electrical
Issued 10 October 1994 Resolved
PROVE PROPER OPERATION OF REMOTE SWITCH FOR ENGINE ROOM FANS. _x001C_
Condition: Unknown
Due 1 November 1994
Resolved 14 November 1994
Engineering
Issued 10 October 1994 Resolved
PROVE PROPER OPERATION OF STARBOARD INBOARD MAIN ENGINE CONTROLS ENSURE PROPER OPERATIONPRIOR TO VESSEL GETTING UNDERWAY. (NEW ENGINE BRACKETS FORCONTROLS BEING MADE).
Condition: Unknown
Due 1 November 1994
Resolved 14 November 1994
Construction/Loadline
Issued 16 October 1993 Resolved
Make permanent repair to 2" hole in sideshell plating in way of the diesel fuel tank, prior to commercial operations and prior to bunkering operations.
Condition: Unknown
Due 16 October 1993
Resolved 16 October 1993
Unknown
Issued 5 November 1991 Resolved
Replace plastic sight glasses on lube oil tank and waste oil tank with pyrex sight glasses.
Condition: Unknown
Due 13 December 1991
Resolved 13 December 1991
Unknown
Issued 6 November 1990 Resolved
PROVIDE ON BOARD THE WASTE MANAGEMENT PLAN AND PLACARD REQUIRED BY 33 CFR PART 151.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Unknown
Issued 6 November 1990 Resolved
MAKE PERMANENT REPAIRS TO FRACTURED WELDS AT UPPER STARBOARD END OF TRANSVERSE FRAME IN STEERING COMPARTMENT.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Unknown
Issued 6 November 1990 Resolved
INSTALL PRESSURE GAUGE ON DISCHARGE SIDE OF FUEL OIL TRANSFER PUMP.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Unknown
Issued 6 November 1990 Resolved
RENEW DETERIORATED BALL FLOATS IN ALL ON DECK GOOSENECK VENTS.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Unknown
Issued 6 November 1990 Resolved
PROVIDE [name withheld], TEXAS WITH PROOF OF A FEDERAL COMMUNICATIONS COMMISION EXEMPTION FOR SERVICE MORE THAN 100 MILES FROM LAND.
Condition: Unknown
Due 6 November 1990
Resolved 6 November 1990
Electrical
Issued 18 September 1989 Resolved
REPAIR SHORT IN VESSEL'S ANCHOR LIGHT.
Condition: Unknown
Due 18 September 1989
Resolved 18 September 1989
Lifesaving
Issued 18 September 1989 Resolved
PROVIDE AN ADDITIONAL ORANGE SMOKE DISTRESS SIGNAL (VESSEL HAS 5 ON BOARD).
Condition: Unknown
Due 18 September 1989
Resolved 18 September 1989
Documentation
Issued 18 September 1989 Resolved
SHOW PROPER DOCUMENTATION FOR FCC OPERATOR'S LICENSE.
Condition: Unknown
Due 18 September 1989
Resolved 18 September 1989
Lifesaving
Issued 18 September 1989 Resolved
REPLACE FLOAT FREE LINKS TO LIFE FLOATS. VESSEL HAS FIVE LIFE FLOATS GROUPED IN 2 STACKS (2 AND 3 FLOATS). FLOAT FREE LINK TO BE ATTACHED TO STBD STACK OF 2, AND TWO FLOAT FREE LINKS TO BE ATTACHED TO PORT STACK OF THREE (TWO ARE TO BE LINKED TOGETHER).
Condition: Unknown
Due 18 September 1989
Resolved 18 September 1989
Lifesaving
Issued 18 September 1989 Resolved
PROPERLY SECURE STBD LIFE FLOATS (2) TOGETHER AND PROPERLY SECURE PORT LIFEFLOATS TOGETHER (2). LIFE FLOATS ARE IN TWO STACKS WITH THREE FLOAT FREE LINKS.
Condition: Unknown
Due 18 September 1989
Resolved 18 September 1989
Lifesaving
Issued 18 September 1989 Resolved
REPLACE FLOAT FREE LINKS TO LIFE FLOATS. VESSEL HAS FIVE LIFE FLOATS GROUPED IN 2 STACKS (2 AND 3 FLOATS). FLOAT FREE LINK TO BE ATTACHED TO STARBOARD STACK OF 2, AND TWO FLOAT FREE LINKS TO BE ATTACHED TO PORT STACKOF THREE (TWO ARE TO BE LINKED TOGETHER).
Condition: Unknown
Due 18 September 1989
Resolved 18 September 1989
Lifesaving
Issued 18 September 1989 Resolved
PROPERLY SECURE STBD LIFE FLOATS (2) TOGETHER AND PROPERLY SECURE PORT LIFE FLOATS TOGETHER (2). LIFE FLOATS ARE IN TWO STACKS WITH THREE FLOAT FREE LINKS.
Condition: Unknown
Due 18 September 1989
Resolved 18 September 1989
Documentation
Issued 18 September 1989 Resolved
SHOW PROPER DOCUMENTATION FOR FCC VESSEL OPERATOR'S LICENSE.
Condition: Unknown
Due 18 September 1989
Resolved 18 September 1989
Electrical
Issued 18 September 1989 Resolved
REPAIR SHORT IN VESSEL'S ANCHOR LIGHT.
Condition: Unknown
Due 18 September 1989
Resolved 18 September 1989
Lifesaving
Issued 18 September 1989 Resolved
PROVIDE AN ADDITIONAL ORANGE SMOKE DISTRESS SIGNAL (VESSEL HAS 5 ON BOARD).
Condition: Unknown
Due 18 September 1989
Resolved 18 September 1989
Deck/Cargo
Issued 20 September 1988 Resolved
MAKE PERMANENT REPAIRS TO DECK WINCH.
Condition: Unknown
Due 20 September 1988
Resolved 20 September 1988
Construction/Loadline
Issued 22 April 1986 Resolved
CROP AND RENEW CORNER BRACKETS IN STEERING COMPARTMENT ON STBD SIDE. REWELDFRACTURES AT BOTH CORNERS OF SAME COMPT.
Condition: Unknown
Due 22 April 1986
Resolved 22 April 1986
Electrical
Issued 1 October 1985 Resolved
MAKE PERMANANT REPAIRS TO CONSTAVOLT VOLT GAUGE.
Condition: Unknown
Due 1 October 1985
Resolved 1 October 1985
Navigation
Issued 1 October 1985 Resolved
MADE PERMANANT REPAIRS TO LOWER NOT UNDER COMMAND LIGHT.
Condition: Unknown
Due 1 October 1985
Resolved 1 October 1985
Electrical
Issued 1 October 1985 Resolved
MAKE PERMANANT REPAIRS TO GENERATER #1 CIRCUIT BREAKER.
Condition: Unknown
Due 1 October 1985
Resolved 1 October 1985
Navigation
Issued 1 October 1985 Resolved
PROCURE CURRENT EDITION OF LIGHT LIST VOLUME II.
Condition: Unknown
Due 1 October 1985
Resolved 1 October 1985
Electrical
Issued 4 October 1984 Resolved
PLACE PROTECTIVE COVER ON EMERGENCY LIGHT SWITCH TAPED IN THE POSITION UNTIL REQUIREMENT IS MET.
Condition: Unknown
Due 4 October 1984
Resolved 4 October 1984

Casualty record · 2

5 March 2007Routine · role: Involved in a Marine Casualty · activity 2889077
22 March 2010Routine · role: Involved in a Marine Casualty · activity 3810116
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.