MAURY USCG vessel records
← All vessels

FIESTA

FIESTA is a 1981 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in March 2026, along with 37 deficiencies, 2 operational controls and 1 casualty investigation in 2021.

Records from 2016 to 2026. Most recent: inspection, 19 March 2026.

Built
1981
Last inspected
19 March 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 19 March 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH6381
Flag
UNITED STATES
Maury page id
psix-53413

Documentation record

Registered dimensions (L × B × D)60.0 ft × 18.6 ft × 4.0 ft
Registered tonnagegross 73 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderA-1 MARINE, INC · PANAMA CITY, FL, UNITED STATES · built 1981
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Regulatory (Subpart C or D), Gross Ton
49 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

19 March 2026 COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8319053
12 May 2025 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8133355
15 August 2024 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7981957
9 July 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7955248
27 April 2023 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7678512
15 August 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7540308
19 April 2022 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7433686
20 August 2021 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7302704
16 March 2021 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7156951
1 December 2020 Internal Structural Exam · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7104923
6 August 2020 Administrative Inspection · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7031722
11 June 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6710535
18 December 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6597117
20 November 2018 In-Service Inspection · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6583994
6 July 2018 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6469491
28 June 2017 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6189910
20 July 2016 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5946713
5 April 2016 COI Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5847465

Deficiency record · 37

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 March 2026 Resolved
It is further intended that all machinery be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure and personnel injury. The starboard engine exhaust cooling hose is deteriorating and must be replaced. 46 CFR 182.01-5(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 April 2026
Resolved 3 April 2026
Resolution: Hose replaced, all sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 19 March 2026 Resolved
Each hatch cover must have securing devices and be attached to the hatch frame or coaming by hinges, captive chains, or to other devices to prevent its loss. Hatch covers on board do not have securing devices, degraded gasket and line was detached from the deck to prevent its loss. All watertight hatches require maintenance with securing devices. 46 CFR 171.124(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2026
Resolution: All three watertight hatches were replaced with securring mechanisms.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 19 March 2026 Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. The portside of the stern was degraded and requires fiberglass repair. 46CFR 177.01-5(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 March 2026
Resolution: The fiberglass of the portside of the stern was repaired.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 May 2025 Resolved
46 CFR 176.25-25 (a)(1) The fire pump shall be tested and the fire hose shall be subjected to the available fire pump pressure. The fire pump did not provide enough water pressure due to damaged impeller.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 May 2025
Resolved 13 May 2025
Resolution: Vessel submitted video evidence that impeller was fixed. Sufficient pressure was observed.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 12 May 2025 Resolved
46 CFR 182.25-5(d) The bilge pipe piercing the collision bulkhead shall be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from above the weather deck. The overboard discharge bilge pipe in forward void did not have a valve.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 22 May 2025
Resolution: Recieved photo evidence of a valve connected to the overboard discharge bilge pipe in forward void.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 May 2025 Resolved
46 CFR 181.20-20(d) All dead end lines must shall extend at least 2 inches beyond the last orifice and shall be closed with cap or plug. CO2 nozzles are missing 2” piping extension.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 June 2025
Resolved 23 June 2025
Resolution: Received picture evidence of extension line over 2 inches beyond the last orifice and closed with a cap.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 12 May 2025 Resolved
46 CFR 182.25-5(b) The bilge suctions shall be fitted with suitable strainers having an open area not less than three times the area of the bilge pipe. Electric bilge pump in the engine room was floating and not fixed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 22 May 2025
Resolution: Vessel rep provided video evidence of a fixed bilge pump in the engine room.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 12 May 2025 Resolved
46 CFR 182.455(b)(6) A suitable metal marine type strainer shall be fitted in the fuel supply line in the engine compartment... A drip pan fitted with flame screen shall be installed under the strainer. Flame bulb was not found under the fuel strainer for the port side engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 11 June 2025
Resolution: Recieved photo evidence of a flame bowl installed under the port side engine fuel strainer.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 May 2025 Resolved
46 CFR 185.604(f) The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Labeling for “adult” life preservers in stowage area was missing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 23 June 2025
Resolution: Vessel rep provided picture evidence of clearly legible letters and numbers on each container for adult life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 May 2025 Resolved
46 CFR 182.720-20(a) Rigid nonmetallic materials may be used only in non-vital systems. Plastic zip ties are holding up bilge pipe in #2 void and need to be replaced with metal strap instead.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 22 May 2025
Resolution: Recieved photo evidence of plastic zip ties replaced with a red, metal strap holding up bilge pipe in #2 void.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 May 2025 Resolved
46 CFR 185.604(b) Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Ring life buoy is missing letter “T” of vessel’s name.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 27 May 2025
Resolution: Vessel rep provided picture evidence of "FIESTA" printed on the ring lift buoy.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 May 2025 Resolved
46 CFR 16.230 (d) Marine employers may form or otherwise use sponsoring organizations to conduct random chemical testing program required by this part. Vessel missing 2024 MIS Report.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2025
Resolved 23 May 2025
Resolution: Received photo copy of vessel's 2024 MIS report.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 August 2022 Resolved
46 CFR 176.802: At each initial and subsequent inspection for certification of a vessel the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances. Multiple fiberglass cracks and pits were identified, clean surface for inspection and repair to the satisfaction of CG Marine Inspector. Hole in engineroom fwd bulkhead, repair to the satisfaction of CG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 August 2022
Resolved 25 August 2022
Resolution: Fiberglass repair complete, all sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 31 March 2021 Resolved
SYSTEM DESIGN AND INSTALLATION MUST BE IN ACCORDANCE WITH THE MARINE DESIGN, INSTALLATION, OPERATION, AND MAINTENANCE MANUAL APPROVED FOR THE SYSTEM BY THE COMMANDANT. ONE OF THE TWO CO2 BOTTLES PROTECTING THE MACHINERY SPACE WAS DISCONNECTED FROM THE SYSTEM. THE FLEX HOSE WAS NOT CONNECTED TO THE BOTTLE. 46CFR181.410(3)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2021
Resolved 22 April 2021
Resolution: Discharge hoses connected. System fully operational.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 31 March 2021 Resolved
EACH PENETRATION IS ACCOMPLISHED USING AN ACCEPTABLE METALLIC FITTING, WELDED OR OTHERWISE ATTACHED TO THE BULKHEAD OR DECK BY AN ACCEPTED METHOD. HYDRAULIC STEERING LINE PENETRATIONS ARE NOT USING METALLIC FITTING TO PENETRATE BULKHEADS. 46CFR182.40-1
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2021
Resolved 22 April 2021
Resolution: Metallic fittings installed at bulkhead penetratons.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 March 2021 Resolved
ALL ELECTRICAL INSTALLATIONS SHALL BE TO THE SATISFACTION OF THE OFFICER IN CHARGE, MARINE INSPECTION. FORWARD HOLD HAD CABLE HANDGING FROM LIGHT FIXTURE. 46CFR183.01-15(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2021
Resolved 22 April 2021
Resolution: Light fixture and wiring removed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 31 March 2021 Resolved
ALL ELECTRICAL INSTALLATIONS SHALL BE TO THE SATISFACTION OF THE OFFICER IN CHARGE, MARINE INSPECTION. BOTH MAIN ENGINE STARTER CABLES NEED TO BE PROPERTLY SECURELY MOUNTED. 46CFR183.01-15(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2021
Resolved 22 April 2021
Resolution: Cables properly mounted and supported.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 16 March 2021 Resolved
IT IS FURTHER INTENDED THAT ALL MACHINERY BE INSTALLED AND MAINTAINED IN SUCH A MANNER AS TO AFFORD ADEQUATE PROTECTION AGAINST FIRE, EXPLOSION, MACHINERY FAILURE AND PERSONNEL INJURY. PORT MAIN ENGINE ALTERNATOR HAS EXCESSIVE OIL ON THE HOUSING AND EXPOSED WINDINGS. 46CFR182.01-5
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2021
Resolved 22 April 2021
Resolution: Oil and dust cleaned off of alternator.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2021 Resolved
FUEL SUPPLY PIPING. FLEXIBLE HOSE... SHALL NOT PENETRATE WATERTIGHT BULKHEADS. FUEL SUPPLY FLEX HOSES PENETRATE 2 WATERTIGHT BULKHEADS NOT USING APPROPRIATE METALLIC FITTINGS ATTACHED TO THE BULKHEAD. 46CFR182.20-40(a)(2)(i)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2021
Resolved 22 April 2021
Resolution: Metallic fittings installed at bulkhead penetrations.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 16 March 2021 Resolved
THE MARINE EMPLOYER MUST HAVE A SUFFICIENT NUMBER OF ALCOHOL TESTING DEVICES READILY ACCESIBLE ON BOARD THE VESSEL. VESSEL HAD EXPIRED ALCOHOL SWAPS ONBOARD. 46CFR4.06-15(a)(1)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2021
Resolved 22 April 2021
Resolution: Alcohol test strips present during inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 March 2021 Resolved
INSTALLATION OF DIESEL ENGINE EXHAUST PIPING SHALL BE IAW 46 CFR 182.20-22. PORT EXHAUST PIPING NEEDS TO BE REPAIRED TO ORIGINAL. TEMPORARY REPAIRS NEED TO BE REMOVED. 46CFR182.20-22
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 April 2021
Resolved 22 April 2021
Resolution: Exhaust cooling piping replaced on both main engines.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 1 December 2020 Resolved
A periodic examination shall include the underwater hull and appendages, propellers, shafting, stern bearings, rudders, through hull fittings, sea valves and strainers, and shall be of sufficient scope to determine that these items are in a satisfactory condition for the service intended. - Wood around hatch for fwd hold is rotten and needs replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 December 2020
Resolved 11 March 2021
Resolution: All wasted area in vicinity of fwd hatch cropped and renewed. Hatch functionality sat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Control of discharge
Issued 6 August 2020 Resolved
Remove oily bilge water collected under bilge suction cup.
Action required: 10 - Deficiency Rectified
Due 6 August 2020
Resolved 6 August 2020
Resolution: Cleared on the spot
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 13 July 2017 Resolved
PROVIDE FCC RADIO TELEPHONY CERTIFICATE.
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 13 July 2017
Resolution: PROVIDED FCC RADIO TELEPHONY CERTIFICATE.
Electrical › Lighting (service) › Lighting Fixture
Issued 29 June 2017 Resolved
CAP OR REMOVE DEAD END WIRES IN OPERATING STATION, ENGINE ROOM AND AFT DECK.
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 13 July 2017
Resolution: REMOVED DEAD END WIRES IN OPERATING STATION, ENGINE ROOM, AND AFT DECK.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 29 June 2017 Resolved
RE-CONFIGURE ANCHOR AND ANCHOR LINE CONNECTION.
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 13 July 2017
Resolution: RE-CONFIGURED ANCHOR AND ANCHOR LINE CONNECTION.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 June 2017 Resolved
PROVIDE 60' LINE FOR RING BUOY.
Action required: 705 - Other - as specified
Due 13 July 2017
Resolved 13 July 2017
Resolution: PROVIDED 60' LINE FOR RING BUOY.
Stability › Watertight Integrity › General
Issued 21 July 2016 Resolved
provide repair proposal for starboard forward fore peak rotted wood and improper repair. For approval by [name withheld] to be conducted upon approval, not later than 21AUG16.
Condition: Invalid
Action required: 705 - Other - as specified
Due 21 August 2016
Resolved 1 September 2016
Stability › Watertight Integrity › General
Issued 21 July 2016 Resolved
Repair as original forward starboard fore peak rotted wood at deck level. Due not later than 21AUG16.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 August 2016
Resolved 1 September 2016
Resolution: Vessel repaired as original forward starboard fore peak rotted wood at deck level.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 21 July 2016 Resolved
Replace both, port and starboard, cutlass and strut bearings due to 50% wear. Prior to credit dry dock and carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 July 2016
Resolved 22 July 2016
Resolution: Vessel replaced both port and starboard cutlass and strut bearings.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 7 April 2016 Resolved
Provide 01 lifejacket
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 21 April 2016
Resolution: Vessel provided 01 lifejacket
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 7 April 2016 Resolved
Provide FCC Operations Permit
Action required: 705 - Other - as specified
Resolved 7 April 2016
Lifesaving › Lifebuoys › Serviceable
Issued 7 April 2016 Resolved
Provide renewed Ring Buoy
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 21 April 2016
Resolution: Vessel provided renewed Ring Buoy.
Fire Fighting › Combustible Materials › Insulation
Issued 7 April 2016 Resolved
Renew Engine Space insulation.
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 21 April 2016
Resolution: Engine Space insulation was renewed.
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 7 April 2016 Resolved
Provide Waste Management Plan
Action required: 705 - Other - as specified
Resolved 7 April 2016
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 7 April 2016 Resolved
Provide Emergency Instructions
Action required: 705 - Other - as specified
Resolved 7 April 2016
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 April 2016 Resolved
Remove Seating or provide fixed seating
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 21 April 2016
Resolution: Provided fixed seating on main exterior deck. Fabricated new benches in the same design/layout as what was previously there.

Casualty record · 1

20 August 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 2 injured · activity 7302704
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.