Records from 2016 to 2026. Most recent: inspection, 24 February 2026.
07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 19 March 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must be installed in accordance with the manufacturer’s instructions. Override switch for Fire-boy in engine compartment is not a factory switch. Replace override switch in accordance with manufacture guidance and notify local OCMI once installed to conduct operational test of new part.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2025
Resolved 19 May 2025
Resolution: MI attended vessel to conduct test on new Fire-Boy components. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 March 2025
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Marking not provided on exterior of space where life jackets stowed. Provide proper marking on exterior of space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2025
Resolved 25 March 2025
Resolution: Marking provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 March 2025
Resolved
Portable extinguisher must be located so that they are clearly visible. Extinguisher stowed in cabinet and no marking provided. Provide marking on exterior of storage area to show that extinguisher is inside.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2025
Resolved 25 March 2025
Resolution: Extinguisher marking provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 March 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. One of the starters power cables was bent at a 90 degree angle and cause it to break and expose metal wires from the inside.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2025
Resolved 25 March 2025
Resolution: New starter cable provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 March 2025
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Bilge pump indicator at helm not installed. Provide visual indicator for bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2025
Resolved 25 March 2025
Resolution: Bilge pump visual indicator provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 March 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Dead end wires found in engine compartment. Remove dead end wiring and update electrical plans.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2025
Resolved 25 March 2025
Resolution: Dead end wiring removed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 March 2025
Resolved
A submersible electric bilge pump may be used as a power bilge pump required must have a positive shutoff valve is installed at the hull penetration. Pump was not permanently mounted. Permanently mount pump and notify local OCMI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 April 2025
Resolved 25 March 2025
Resolution: Pump mounted.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 April 2024
Resolved
Observed fire firefighting systems, engine shut downs and override start. Vessel is to make repairs by an authorized repair shop and have CG MI observe final testing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 April 2024
Resolution: observed testing of fireboy. All SAT
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 March 2024
Resolved
Observed the following sail rigging concerns:
The main mast turn buckle loose and a washer used as a spacer on the cranse iron. The main mast portside aft chain plate is loose. The Mizzen mast STBD forward chain plate is loose. Have a qualified third party surveyor to determine the operating conditions of all the vessel's sail rigging and components. Followed by a repair or replacement in kind proposal and USCG Marine Inspector attends vessel while underway on sails.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2024
Resolution: Observed repairs to chain plate, all SAT
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 28 March 2024
Resolved
Observed FWD and AFT bilge alarms not functioning as intended to. Repair or replace both bilge alarms.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2024
Resolution: Tested alarms, All SAT
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 28 March 2024
Resolved
Vessel did not have an updated crew roster and required testing kits for the drug and alcohol program. Update crew's list and have required testing kits on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 March 2024
Resolution: Vessel's POC provided images of crew list and alcohol swabs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 28 March 2024
Resolved
Observed dead-end wiring in the battery compartment and next to sewage overboard valve. Remove wiring if not in use or place in a terminal box.
46CFR183.10-20
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 April 2024
Resolution: Observed deadend wires in terminal
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 March 2024
Resolved
Vessel is missing a 40B:C portable extinguisher. Vessel is to have a 40B:C portable extinguisher adjacent to the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 April 2024
Resolution: Completed successful testing of fixed fire system.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 28 March 2024
Resolved
Portside NAV light does not turn on. Make repairs for the NAV light to function.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 April 2024
Resolution: Observed NAV lights, All SAT
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 March 2024
Resolved
Vessel did not have complete first aid kit, current kit has expired items. Vessel is to have an updated kit on board.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 April 2024
Resolution: observed first aid kit, all SAT
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 28 March 2024
Resolved
Vessel did not have a current Certificate of Documentation (COD). Vessel is to have a current copy of COD on board at all times.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 March 2024
Resolution: POC provided an image of current COD and will post.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 28 March 2024
Resolved
One of the vessel's life float EPIRB did not operate. Vessel is to have an operating EPIRB.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 April 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 27 February 2024
Resolved
Vessel's COI expired on 11MAR2024 while the vessel was hauled out for credit hull exam. Vessel is scheduled for a COI renewal on 28MAR24. Vessel is restricted from carrying passengers until it has received a valid COI from Sector San Diego. During COI renewal, preform an underway sea trial under sail to demonstrate all repairs made during dry dock.
Action required: 705 - Other - as specified
Due 28 March 2024
Resolved 28 March 2024
Resolution: Issued COI
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 27 February 2024
Resolved
Vessel received 2 year credit hull exam in March 2024. Rotted wood was identified on three silicon bronze floor fames where metal contacted the frames. Two frames just forward of the fuel tank in the galley bilge were properly corrected and all rotted areas were fully replaced. The rotted frames identified directly below the compass stand in the helm bilge were only partially repaired. In order to fully access the lower section of frames (that are sandwiched between the silicon bronze floors and hull planking) requires removal of the aft deck and deck support beams. At the 2026 hull exam the lower section of frames are required to be excavated and renewed for the vessel to receive 2 year hull credit.
Action required: 705 - Other - as specified
Due 28 February 2026
Resolved 24 February 2026
Resolution: Inspected previous areas identified and determined areas of concern did not necessitate repair. Added as special note for future inspections
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 21 February 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 23 February 2023
Resolution: replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 11 March 2022
Resolved
The strength of the float-free link must be determined by the combined capacity of the group of life floats. Replace Float-free link with correct size and correctly attach painter to link and life float.
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2022
Resolved 22 March 2022
Resolution: POC installed weak link IAW manufacturers instruction.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 March 2022
Resolved
A life jacket shall be provided for each person on board. Replace wasted of missing life jackets. passenger count reduced to 15 adults and 6 children (4 required by COI and 2 extras you have on board).
Action required: 705 - Other - as specified
Due 11 April 2022
Resolved 22 March 2022
Resolution: POC replaced wasted lifejackets with new.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 11 March 2022
Resolved
GPS not wired to VHF radio to allow digital selective calling function (DSC) to provide vessel's LAT and Long and MMSI.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2022
Resolved 22 March 2022
Resolution: POC programmed radio with MMSI and GPS information.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 March 2022
Resolved
Found dead end wires throughout vessel and loose ground wire near potable water tank. Wire should be removed or connected to appropriate component.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2022
Resolved 19 March 2025
Resolution: Attended vessel, ALL SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 11 March 2022
Resolved
Flares where expired, provide 12 red flares or 6 red and 6 orange to maintain a limited coast wise route. Currently hold 8 red flares which will limit route to Lakes Bays and Sounds until rectified.
Action required: 705 - Other - as specified
Due 11 April 2022
Resolved 22 March 2022
Resolution: Replaced flares with appropriate amount of new.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 18 February 2022
Resolved
forward sections on the port/starboard side of vessel separating wood planks and the iron keel needs to be excavated down to good wood and resealed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 March 2022
Resolved 3 March 2022
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 February 2021
Resolved
A pre-engineered fixed gas fire extinguishing system must automatically shut down all power ventilation systems and all engines that draw intake air from within the protected space. During manual activation by crew engine kept running.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2021
Resolution: Witnessed successful shutdown/override test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 February 2021
Resolved
Fuel Shutoff valves, installed so as to close against the fuel flow. During remote activation by crew valve failed to its fully closed position.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 February 2021
Resolution: USCG MI Witnessed satisfactory operation of Remote fuel shut-off valve
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 February 2021
Resolved
During test throttle control handle had separated and broke from its morse control.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 February 2021
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 February 2021
Resolved
Vessel not equip with fire pump must have at least (3) 2.5 gallon buckets with attached lanyards and labeled "FIRE BUCKETS".
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 February 2021
Resolution: vessel equip with 3 fire buckets; holes were drilled into existing 5 gallon buckets at the 2.5 gallon water mark to suffice.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 February 2021
Resolved
Replace bilge alarm light indicator cover, and provide labeling to light indicator.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 22 March 2021
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 February 2021
Resolved
Install SOLAS reflective tape on back side of life ring and repair grab line around ring.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 22 March 2021
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 22 February 2021
Resolved
Renew /replace SOLAS reflective tape on both Life floats.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 22 March 2021
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 February 2021
Resolved
PORT side near Bowsprit forward stanchion; bolt is missing retaining nut.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 23 March 2021
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 February 2021
Resolved
STBD side near Bowsprit: Bottom stanchion at deck 2 of the 3 deck screws are loose.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 22 March 2021
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 February 2021
Resolved
STBD side near Bowsprit: middle cable railing: bolt is missing retaining nut.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 23 March 2021
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 February 2021
Resolved
Bowsprit metal top plate PORT side missing hardware.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 22 March 2021
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 February 2021
Resolved
STBD Side Aft mast shroud deck plate separated/ lifted from deck.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 22 March 2021
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 February 2021
Resolved
STBD quarter at stern stanchion at deck missing bolt.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 22 March 2021
Resolution: Corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 28 April 2020
Resolved
Replace floating water light battery, replace floating water light line. Due 28May2020.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 May 2020
Resolved 1 May 2020
Resolution: Replaced.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 28 April 2020
Resolved
Prove proper operation of fixed system alarm, shutdown, override prior to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2020
Resolution: Replaced system, tested in all modes.
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 April 2018
Resolved
Cap dead end wiring under port cockpit seat.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018
Resolved 17 May 2018
Resolution: Wires capped.
Construction/Loadline › Penetrations › Bottom Plug
Issued 26 April 2018
Resolved
Cap thru hull starboard side engine room. Currently loose hose with no cap.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018
Resolved 17 May 2018
Resolution: Through hull capped.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 26 April 2018
Resolved
Provide crew proof of enrollment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018
Resolved 17 May 2018
Resolution: Crew drug enrollment provided.
Sail Rigging › Chainplates › Materials
Issued 26 April 2018
Resolved
Provide rig report stating purpose of cracked plate forward attached to bow sprit. Either replace if needed for rig or remove if not needed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018
Resolved 17 May 2018
Resolution: Rig report provided. Plate will remain onboard. Notified owner to continue to monitor crack.
Navigation › Piloting/Steering › Marine Charts
Issued 26 April 2018
Resolved
Provide current chart.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018
Resolved 17 May 2018
Resolution: Chart provided.
Lifesaving › Lifefloat › Float Free
Issued 26 April 2018
Resolved
Provide weak link for life floats.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018
Resolved 17 May 2018
Resolution: Float free link provided.
Communications › Radio Communications › EPIRB
Issued 26 April 2018
Resolved
Provide new hydro release unit and mount EPIRB properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018
Resolved 17 May 2018
Resolution: New hydro release provided and EPIRB mounted.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 25 April 2016
Resolved
Label lifejacket stowage locations
Due 25 May 2016
Resolved 29 April 2016
Resolution: Lifejacket stowage marked.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 April 2016
Resolved
Attach waterlights to lifefloat
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: Waterlights are properly attached.
Lifesaving › Lifefloat › Float-free Link
Issued 25 April 2016
Resolved
Properly install lifefloats (weak link and daisy chain)
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: Lifefloats properly installed
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 April 2016
Resolved
Provide all publications reqd by 46CFR184.420
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 6 May 2016
Resolution: Recieved email proving all pubs are current and onboard.
Engineering › Fuel Oil Service System › Valve
Issued 25 April 2016
Resolved
Mark emergency fuel shutoff
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 29 April 2016
Resolution: Emergency fuel shutoffs properly labeled.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 April 2016
Resolved
Provide serviceable first aid kit
Action required: 705 - Other - as specified
Due 29 April 2016
Resolved 29 April 2016
Resolution: Serviceable first aid kit onboard.