Registered dimensions (L × B × D)90.8 ft × 32.0 ft × 10.1 ft
Registered tonnagegross 232 / net 157
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMAIN IRON WORKS INC · HOUMA, LA, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 6 June 2026 · expires 31 July 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it232 - Regulatory (Subpart C or D), Gross Ton 157 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 38 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 10 other vessels inspected with it; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
The Coast Guard recorded this vessel and the following in the same
inspection activity — normally a tug and the barges in its tow. A recreational or
unclassed hull in the same activity is held and not published, so it does not appear
here: these lists are a floor, not a complete manifest.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 June 2025Resolved
Vessel reported engine shutdown at MM 101.5 while transiting to LMR MM 115.7. Vessel currently docked at MM 103.5; authorized one-time lightship transit with assist tow (M/V BUNKER KING, 953419) to John W. Stone Oil Distributor LLC (MM 96.5) for inspection. Vessel to rectify damage to satisfaction of the attending CG marine inspector prior to movement from John W. Stone Oil Distributor LLC (MM 96.5).
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 June 2025
Resolution: RCVD tech report and witness testing of MDE.ALL state to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 October 2022Resolved
Individual circuit breakers on switchboards and distribution panels must be labeled with a description of the loads they serve. Marine Inspector found breaker panels missing some labels on the circuit breakers and names for the load they serve.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2022
Resolved 27 October 2022
Resolution: Vessel personnel lebeled circuit breakers throughout the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 October 2022Resolved
Electrical systems and equipment must function properly and minimize system failures and fire and shock hazards. Marine Inspector found that generator #1 did not have a functioning amp meter, and generator #3 did not have an amp meter, voltage meter, and frequency meter. “Power Available” lights for generator #2 and #3 were not functioning.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2022
Resolved 27 October 2022
Resolution: A new meter was installed for #3 SSDG to provide APMS, Voltage and Hertz. Power available lights were fixed for all 3 SSDG's and all meters for #1 and #2 SSDG's were correctred to display proper readings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 October 2022Resolved
Essential systems or equipment must be regularly tested and examined. Tests and examinations must verify that the system or equipment functions as designed. If a component is found unsatisfactory, it must be repaired or replaced. Test and examination procedures must be in accordance with manufacturer's instructions or the Towing Safety Management System (TSMS) applicable to the vessel, if the vessel has a TSMS. Marine Inspector found that the relief valves for air compressors had not been tested or serviced as required by regulation. Valve lever for port air compressor was found broken.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2022
Resolved 27 October 2022
Resolution: Vessel company purchased and installed new relief valves.
The master must ensure that all hatches, doors, and other openings designed to be watertight or weathertight function properly. During the inspection the vessels crew was unable to fully secure the watertight door.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 October 2022
Resolved 27 October 2022
Resolution: Vessel crew installed new gaskets on all WTD doors. chalk tested doors with satisfactory results
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 October 2022Resolved
To stop the flow of fuel in the event of a fire or break in the fuel line, a remote fuel shutoff valve must be fitted on any fuel line that supplies fuel directly to a propulsion engine or generator prime mover.The remote fuel shut off valve for the aft STBD fuel tank was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 October 2022
Resolved 14 October 2022
Resolution: Crew made repairs and was operation prior to departure from exam.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 September 2021Resolved
(2) The system is installed, tested, and maintained in accordance with the manufacturer's design manual;
Smoke alarms in berthing areas expired. Were valid for 10 years starting in 2009.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 September 2021
Resolved 20 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 September 2021Resolved
(b) Installed electrical power source(s) must be capable of carrying the electrical load of the towing vessel under normal operating conditions.
Improper cable from battery to starter on generators.. Must have cable rated for electrical systems installed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2021
Resolved 5 October 2021
Resolution: Installed appropriate battery cables.