RIP RUNNER

RIP RUNNER is a 1975 passenger vessel (inspected). The Coast Guard has recorded 45 inspections since 1981, most recently in October 2025, along with 23 deficiencies.

Records from 1981 to 2025. Most recent: inspection, 24 October 2025.

Built
1975
Last inspected
24 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC6592
Flag
UNITED STATES
367058250 (licence lapsed)
Maury page id
psix-53472

Inspections, by type

…with no type recorded8
Years with a record 33 calendar years (1981–2025)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.1 ft × 14.2 ft × 5.9 ft
Registered tonnagegross 20 / net 14
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE LA, UNITED STATES · built 1975
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBATON ROUGE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Regulatory (Subpart C or D), Gross Ton
14 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC6592MMSI 367058250 · cancelled · voluntarily equipped · granted 19 June 2025, cancelled 11 September 2025
WCP9774MMSI not assigned · expired · compulsorily equipped · granted 21 February 1995, cancelled 23 April 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

RIVERS FLEETS IV Passenger (Inspected) · MISLE 97060 · 26 May 1994 · activity 62414

Inspection history · 45

24 October 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8258129
10 January 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8047232
18 September 2023 Examination of Repairs · Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7790385
17 January 2023 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7617312
8 November 2021 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7340759
6 September 2021 Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7305645
10 November 2020 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7093282
6 November 2019 Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6850586
25 September 2018 Drydock Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6548735
28 June 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6458349
15 December 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6322886
10 November 2016 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6036558
16 October 2015 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5744240
30 December 2010 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3914751
23 February 2010 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3681809
11 February 2010 DAPI Audit · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3675045
29 September 2008 Annual Inspection · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3331760
13 December 2007 Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3107226
20 October 2006 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2804491
11 October 2005 Annual Inspection · MTSA Verification
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2512187
4 August 2004 Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2154323
17 June 2003 Annual Inspection · Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1819590
9 August 2002 Deficiency Check · Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1658851
3 August 2001 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1420552
10 January 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 59212
7 August 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1417101
29 July 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1384215
16 November 1998 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1451341
21 July 1998 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1470466
26 April 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 789418
25 February 1997 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 758671
24 February 1997 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 196734
20 May 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1456374
26 May 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 872227
21 April 1995 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1425576
26 May 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 62414
2 June 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 832632
2 April 1993 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1443367
7 November 1990 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1235177
25 October 1989 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 894807
26 April 1988 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1035199
24 June 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007402
2 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284244
26 May 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970050
10 November 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973748

Deficiency record · 23

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 November 2021 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a).
Action required: 60 - Rectify deficiencies prior to movement
Resolved 22 November 2021
Resolution: Vessel conducted operational test of the bilge systems to the satisfaction of the attending marine inspector. All Sat.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 8 November 2021 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its COI. 46 CFR 177.100. Discovered a cracked stitch weld on a vertical stiffener in the steering flat.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2021
Resolved 22 November 2021
Resolution: Cracked welds were repaired to the satisfaction of the attending marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 November 2021 Resolved
Accessories, such as switches, fuses, and sockets, shall be National Electrical Code types for the loads to be carrid and shall be of types listed by or types equal to those listed by Underwriter's Laboratories, Inc., or other recognized testing laboratory. 46 CFR 183.05-35(a). The installed fuses in serving the wheelhouse control panel were not types listed by or types equal to those listed by Underwriter's Laboratories, Inc.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2021
Resolved 22 November 2021
Resolution: Vessel replaced fuses with UL approved type. All Sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 November 2021 Resolved
Accessories, such as switches, fuses, and sockets, shall be National Electrical Code types for the loads to be carrid and shall be of types listed by or types equal to those listed by Underwriter's Laboratories, Inc., or other recognized testing laboratory. 46 CFR 183.05-35(a). The installed fuses in serving the engine room control panel were not types listed by or types equal to those listed by Underwriter's Laboratories, Inc.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 December 2021
Resolved 22 November 2021
Resolution: Vessel replaced fuses with UL approved type. All Sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 6 September 2021 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. 46CFR177.100
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 September 2021
Resolution: Report revealed no damage
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 4 October 2018 Resolved
Discovered port and stbd engine room intake covers missing. Provide vent covers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2018
Resolution: Received photographic documentation attesting to correction of deficiency.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 30 December 2010 Resolved
Gen-set was recently removed from vessel with all service piping and wires remaining in place. Fuel and water have been properly terminated. Electrical system has several components that need to be removed and properly dead ended.
Due 12 January 2011
Resolved 6 January 2011
Resolution: Electrical components have been removed and properly dead ended.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 30 December 2010 Resolved
Provide proper brackets for fire extinguishers.
Due 12 January 2011
Resolved 30 December 2010
Resolution: While departing company aquired two brackets and began replacing.
Engineering › Steering Gear System › Hydraulic Hose
Issued 23 February 2010 Resolved
Five hoses on hydraulic system in steering gear compartment were found to be wrong type. Ensure all hydraulic non-metallic flexible hoses comply with SAE J-1942.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 March 2010
Resolved 25 March 2010
Electrical › Lighting (service) › Lighting Fixture
Issued 11 February 2010 Resolved
Reposition mast head light as to be visible from front of vessel. Light is obscured by Foruno pod.
Action required: 705 - Other - as specified
Due 11 March 2010
Resolved 23 February 2010
Resolution: Remounted and rewired mast head light to ensure proper visibility.
Engineering › Lubricating Oil Service System › Hose
Issued 11 February 2010 Resolved
Ensure all fuel and lube oil non-metallic flexible hoses comply with SAE J-1942. Two hoses on port engine were found to be wrong type.
Action required: 705 - Other - as specified
Due 11 March 2010
Resolved 23 February 2010
Resolution: Replaced hoses on port engine with hose that meets SAE J-1942.
Engineering › Steering Gear System › Bracket/Clamp
Issued 11 February 2010 Resolved
Ensure steering stops are properly located so as to stop rudders before reaching mechanical limits of steering system.
Action required: 705 - Other - as specified
Due 11 March 2010
Resolved 23 February 2010
Resolution: Welded steering stops to prevent the rudder from reaching limits of the steering system.
Construction/Loadline › Hull
Issued 11 August 2003 Resolved
Side shell and bulkhead fractured on port side between engine room and passenger compartment. LEGACY COMPONENT DESC: Side Shell
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2003
Resolution: Repairs completed, witnessed sat hose test of repairs.
Construction/Loadline › Hull
Issued 8 August 2003 Resolved
03 Fractured welds in aft steering compartment and 04 engineroom to be repaired.
Due 8 September 2003
Resolved 29 August 2003
Resolution: All Fractured welds have been repaired.
Lifesaving › Lifebuoys
Issued 17 June 2003 Resolved
Line to Rng Buoy improperly stowed causing line to be tangled. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 August 2003
Construction/Loadline › Hull
Issued 17 June 2003 Resolved
Make Permanemnt repairs to port side shell and blkhd between engine room and cabin, prior to carrying passengers. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Due 11 September 2003
Resolved 29 August 2003
Resolution: Repairs completed.
Engineering › Freshwater System (jacketwater cooling)
Issued 17 June 2003 Resolved
Make repairs to port side keel cooler at hull welds, prior to carrying passengers. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Due 11 September 2003
Resolved 29 August 2003
Resolution: Repairs completed, witnessed sat test.
Electrical › Electrical Distribution System (service)
Issued 17 June 2003 Resolved
Properly label bilge alarm panel on main operating station. LEGACY COMPONENT DESC: Panelboard
Condition: Improper Installation
Due 8 September 2003
Resolved 29 August 2003
Resolution: Bilge alarm panel re-labeled.
Construction/Loadline
Issued 3 August 2001 Resolved
A positive shutoff valve not installed in the discharge line of submersibleelectric pump at the hull penatration as required by 46 CFR 182.520(E)(7)._x001C__x001C_ See 46CFR182.115(B) for applicability to exsisting vessel.
Condition: Unknown
Due 3 September 2001
Resolved 26 August 2002
Construction/Loadline
Issued 3 August 2001 Resolved
Make permanent repairs to bilge piping at aft engine room bulkhead.
Condition: Unknown
Due 3 September 2001
Resolved 26 August 2002
Construction/Loadline
Issued 3 August 2001 Resolved
Bilge piping not fitted with check valves at manifold or other accessible point as required by 46 CFR 182.25-5(C).
Condition: Unknown
Due 3 September 2001
Resolved 26 August 2002
Documentation
Issued 21 July 1998 Resolved
VESSEL WAS OPERATING WITH AN EXPIRED COI.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Electrical
Issued 2 April 1993 Resolved
PROVE PROPER OPERATION OF THE VESSELS SERVICE GENERATOR (A/C ONLY).
Condition: Unknown
Due 2 April 1993
Resolved 2 April 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.