MAURY USCG vessel records
← All vessels

SPEEDY'S DELIGHT

SPEEDY'S DELIGHT is a 1981 passenger vessel (inspected). The Coast Guard has recorded 1 inspection in 2016, along with 8 deficiencies — 8 with no resolution recorded —.

Records in 2016. Most recent: inspection, 14 March 2016.

Built
1981
Last inspected
14 March 2016
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 March 2016
…past their stated due date8
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2016)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

ZJL3889
Flag
VIRGIN ISLANDS, BRITISH
Maury page id
psix-53474

Documentation record

Tonnage as PSIX records it38 - Regulatory (Subpart C or D), Gross Ton
24 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 1

14 March 2016 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5832683

Deficiency record · 8

Construction/Loadline › Hull › Weld
Issued 15 March 2016 No resolution recorded
Make permanent repairs to cracked weld on STBD strut inboard strut doubler.
Action required: 705 - Other - as specified
Due 15 April 2016 — due date passed with no resolution recorded
Engineering › Bilge Water Management System › Strainer
Issued 15 March 2016 No resolution recorded
Provide proper sized bilge strainers on all bilge piping.
Action required: 705 - Other - as specified
Due 15 April 2016 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Piping
Issued 15 March 2016 No resolution recorded
Prove proper operation of emergency fuel shut-off valve.
Action required: 705 - Other - as specified
Due 15 April 2016 — due date passed with no resolution recorded
Engineering › Fuel Oil Service System › Vent Pipe
Issued 15 March 2016 No resolution recorded
Provide bonding wire for fuel vent piping.
Action required: 705 - Other - as specified
Due 15 April 2016 — due date passed with no resolution recorded
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 March 2016 No resolution recorded
Properly secure wire lumbe between wheel house and engine room.
Action required: 705 - Other - as specified
Due 15 April 2016 — due date passed with no resolution recorded
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 March 2016 No resolution recorded
Remove extra battery from space below the wheel house.
Action required: 705 - Other - as specified
Due 15 April 2016 — due date passed with no resolution recorded
Electrical › Electric Supply System (service) › Battery Installation
Issued 15 March 2016 No resolution recorded
Properly secure whell house battery and provide cover.
Action required: 705 - Other - as specified
Due 15 April 2016 — due date passed with no resolution recorded
Engineering › Sea-water System (primary cooling) › Valve
Issued 15 March 2016 No resolution recorded
Prove proper operation of prt engine sea valve and fire pump sea valve.
Action required: 705 - Other - as specified
Due 15 April 2016 — due date passed with no resolution recorded

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.