JOLIE BLONDE

JOLIE BLONDE is a 1981 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2017, most recently in May 2025, along with 25 deficiencies.

Records from 2017 to 2025. Most recent: inspection, 27 May 2025.

Built
1981
Last inspected
27 May 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 May 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2017–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ5799
Flag
UNITED STATES
Maury page id
psix-53477

Documentation record

Registered dimensions (L × B × D)44.8 ft × 14.0 ft × 6.2 ft
Registered tonnagegross 26 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT INC · LOREAUVILLE LA, UNITED STATES · built 1981
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portEMPIRE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 September 2025 · expires 31 October 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 11

27 May 2025 Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8129609
13 June 2024 Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7923501
7 September 2023 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7768946
6 June 2023 Drydock Exam · Internal Structural Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7690861
9 June 2022 COI Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7438696
13 May 2021 Drydock Exam · Deficiency Check · Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7180803
7 May 2020 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6949636
14 June 2019 Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6713669
8 November 2018 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6579856
2 August 2018 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6492673
2 February 2017 Construction Oversight · In-Service Inspection · Simplified Stability Test · Administrative Inspection · Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6079697

Deficiency record · 25

02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 27 May 2025 Resolved
A drydock examination conducted in compliance with 176.100 must be conducted, while the vessel is hauled out of the water or placed in a drydock. MI observed wasted pilot house door hinges, holed exterior bulkhead forward of pilot house door, PORT aft and STBD Fwd E/R bulkhead penetrations need filled, decking in PAX cabin wasted. 46CFR176.610(a).
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2025
Resolved 4 June 2025
Resolution: All wastage had been examined and rectified during COI.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 13 June 2024 Resolved
The person in command of a document vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Vessel did not have on board the current COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2025
Resolution: Vessel COI was brought onboard prior to endoresement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 June 2024 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. MI found STBD main engine rotating belt was not covered.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2025
Resolution: All guards have been installed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 June 2024 Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. MI found vessel to only have two buckets. Vessel provided an additional one.
Action required: 10 - Deficiency Rectified
Resolved 13 June 2024
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 7 September 2023 Resolved
Each survival craft must be: Secured to the vessel by a painter wit a float-free link permanently attached to the vessel. MI discovered the painter line configured in a manner that would not allow the weak link to gain tension. 46 CFR 180.1309(a)(a)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 7 September 2023
Resolved 7 September 2023
Resolution: Master reconfigured the weak link correctly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 7 September 2023 Resolved
Gauges to indicate engine revolutions per minute (RPM) must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. MI found inoperable RPM gauges for both propulsion engines in the operating station. Repairs to be made for functioning gauges to the satisfaction of the attending MI. 46 CFR 182.410(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 28 September 2023
Resolution: Rep submitte objective evidence showing the required gauges operational.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 7 September 2023 Resolved
In systems and applications where flexible hoses are permitted to be clamped: Double hose clamping is required where practicable. MI discovered multiple flexible hoses secured by only one clamp. Hoses are to be double clamped and objective evidence submitted to the satisfaction of the MI. 46 CFR 182.410(d)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 18 September 2023
Resolution: Installed double clamps on all identified non-metallic hoses.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2023 Resolved
Each battery must be secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray. MI found both battery boxes with unsecured batteries, and water in the box. Water to be completely removed, boxes wiped dry, and source of leak found. Batteries to be secured from shifting to the satisfaction of the attending marine inspector. 46 CFR 183.350(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 18 September 2023
Resolution: Water was removed, batteries propely secured to prevent shifting.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect crew, and the vessel from electrical hazards. MI discovered multiple exposed wires in the machinery space. Make proper connection or remove exposed wires to the satisfaction of the attending marine inspector. 46 CFR 183.200(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 18 September 2023
Resolution: Proper connections were made to the open wires.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 September 2023 Resolved
Each lighting fixture, globe, lens, or diffuser must have a guard. MI found light bulbs under the steering console without guards. Place a proper guard to protect the bulb to the satisfaction of the MI. 46 CFR 183.410(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 28 September 2023
Resolution: Light fixture was removed entirely.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 7 September 2023 Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering system of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. MI discovered the steering ram pedestal secured by a single bolt with no securing nut, causing excessive play of the ram. Properly secure the ram to the satisfaction of the attending MI. 46 CFR 176.814
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 18 September 2023
Resolution: Steering Ram was secured using two nuts to avoid backing.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 September 2023 Resolved
All accessories installed in the fuel line must be independently supported. MI found the fuel filter on the generator prime mover loose and supported by an oil absorbing pad. 46 CFR 182.455(b)(7)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 September 2023
Resolved 21 September 2023
Resolution: Fuel filter was properly secured.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 7 September 2023 Resolved
Piping, including valves, pipe fitting and flanges, conveying vapors, gas, or liquid, temperature of which exceeds 65.5C (150 F), must be suitably insulated where necessary to prevent injuries. MI found several areas were dry exhaust was exposed.
Action required: 10 - Deficiency Rectified
Due 7 September 2023
Resolved 7 September 2023
Resolution: Crew placed proper insulation around exposed areas.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 June 2022 Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the FCC as set forth in 47 CFR part 80. Vessel's Safety Radiotelephony Certificate expired on 01 June, 2022.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 June 2022
Resolution: Provided FCC Cert
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 15 June 2021 Resolved
47CFR80.905(a)(5):Vessels must comply with the requirements for a navigation receiver or manual updating of position information contained in 47CFR80.1085(c). Vessel's DSC capable radio could not display position information.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 June 2021
Resolution: Owner provided pictures satisfying deficiency rectification
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 June 2021 Resolved
A generator or motor designed for 40 °C (104 °F) may be used in 50 °C (122 °F) ambient locations provided the generator or motor is derated to 80 percent of the full load rating, and the rating or setting of the overcurrent devices is reduced accordingly. Provide proof from manufacturer that generator is rated for 50 degrees, de-rate the generator to 80 % of the full rated load or replace generator with one rated for 50 degree ambient temperatures prior to operating generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 June 2021
Resolution: company rep provided pictures proving the generator was de-rated.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 June 2021 Resolved
A power-driven vessel underway shall exhibit: Sidelights. Inspector discovered starboard side light inoperable. Repair STBD side light prior to night time operations between sunset and sunrise.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 June 2021
Resolution: Owner provided pictures satisfying deficiency rectification
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 June 2021 Resolved
A vessel at anchor shall exhibit where it can best be seen: A vessel of less than 50 meters in length may exhibit an all-round white light where it can best be seen instead of the lights prescribed in paragraph (a) of this Rule. Inspector noted anchor light inoperable. Repair anchor light prior to anchoring at night between sunset and sunrise.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 June 2021
Resolution: Owner provided pictures satisfying deficiency rectification
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 15 June 2021 Resolved
Shutoff valves, installed so as to close against the fuel flow, the shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located. Fuel valve remote shut-off was found disconnected from valve.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 June 2021
Resolution: Owner provided pictures satisfying deficiency rectification
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 13 May 2021 Resolved
The number of persons capacity must be marked or painted in clearly legible letters and numbers on each life float. Life float was labeled with a 15 person capacity, however per the nameplate it was only rated for 12 persons. Re-label as 12 person capacity.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 15 June 2021
Resolution: Owner provided pictures satisfying deficiency rectification
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 May 2020 Resolved
The master shall conduct sufficient drills and give sufficient instructions to make sure that all crew members are familiar with their duties during emergencies that necessitate abandoning ship or the recovery of persons who have fallen overboard. MI observed lack of necessary equipment (ladder) on board to perform man over board drill as described in instructions. Problem must be recitifed to the satisfaction of the USCG within 7 days.
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 June 2020
Resolved 1 June 2020
Resolution: Vessel provided photographic evidence of def rectified.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 May 2020 Resolved
Electrical equipment on a vessel must be maintained to b) protect passagengers, crew, other persons, and the vessel from eletrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. MI observed loose, dead end electrical wires under console on bridge and in engine room. Problem must be rectified to the satisfaction of the USCG within 7 days.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 2 June 2020
Resolved 1 June 2020
Resolution: Vessel provided photographic evidence of def rectified.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 May 2020 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE-J-1942. Flexible hose runs must be visible, easily accessible, protected from mechanical damage. MI observed unapproved flexible nonmetallic hose on generator with chaffing on bottom-side. In addition, MI observed damage to fuel hose due to chaffing on port engine. Problem must be rectified to the satisfaction of the USCG within 7 days.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 2 June 2020
Resolved 1 June 2020
Resolution: Vessel provided photographic evidence of def rectified.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 8 August 2019 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present. Inpsectors found approx. 8" crack betwen machinery space and lazarette. Prior to carriage of passengers, repair to satisfaction of Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2019
Resolution: Received images of repairs and satisfactor dye penetrant test
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 August 2019 Resolved
Marine Inspectors observed two fuel leaks in lazarette space. Prior to carriage of passengers, correct to satisfaction of marine inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2019
Resolution: Received tech report and photos regarding tightening of tubing fitting and packing gland, resolving both fuel leaks.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.