Records from 1982 to 2000. Most recent: inspection, 7 July 2000.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 47
7 July 2000
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1051894
2 June 2000
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 821681
24 March 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1361397
5 February 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 174739
31 December 1998
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 809333
10 December 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 651303
9 December 1998
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 811433
9 December 1998
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438785
18 November 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1390866
8 September 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1398961
13 November 1997
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1439933
12 December 1996
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1097679
24 September 1996
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1452208
4 June 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1086116
23 January 1996
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1400277
10 November 1995
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 877220
18 October 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1178541
23 September 1994
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396191
17 February 1994
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1440790
8 December 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 851441
5 January 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 831321
11 October 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 944197
26 December 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 962520
16 October 1991
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1254202
21 March 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1242919
23 January 1991
Deficiency Check · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1227770
10 October 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 926439
19 January 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 928939
17 October 1989
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 890426
27 June 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1202064
8 March 1989
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 967567
20 January 1989
Deficiency Check · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1045001
10 October 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1204813
11 February 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1337421
1 October 1987
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1321700
28 August 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309361
6 May 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017319
31 March 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326864
6 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009734
23 October 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018526
24 January 1986
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294474
17 January 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991123
5 December 1985
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 990030
17 January 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290144
8 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281190
7 December 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279444
25 January 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 966465
Fire Fighting
Issued 24 March 2000
No resolution recorded
SUBMIT FOR APPROVAL UPDATED FIRE AND SAFETY PLAN AS VERIFIED THIS DATE. FIELD VERIFIED, SIGNED PLAN MUST BE SUBMITTED WITH NEW PLAN FOR APPROVAL. PROPERLY POST APPROVED PLAN WHEN ONBOARD.
Condition: Unknown
Due 24 May 2000 — due date passed with no resolution recorded
Engineering
Issued 24 March 2000
No resolution recorded
PROVIDE AND PROVE SENSORS FOR REDUCTION GEARS L/O TEMP AND PRESS.
Condition: Unknown
Due 24 August 2000 — due date passed with no resolution recorded
Engineering
Issued 24 March 2000
No resolution recorded
PROVIDE SHAFT TACHS IN PILOTHOUSE IAW NAVIC 1-78 WHICH MONITOR SPEED AND DIRECTION.
Condition: Unknown
Due 24 August 2000 — due date passed with no resolution recorded
Construction/Loadline
Issued 24 March 2000
No resolution recorded
PROVIDE BILGE ALARM FOR STEERING TUNNEL.
Condition: Unknown
Due 23 January 2001 — due date passed with no resolution recorded
Lifesaving
Issued 24 March 2000
Resolved
PROVIDE RESCUE BOAT AND DAVIT IAW D8 POLICY LTR DTD 12NOV98 AND ABS APPROVED PLAN AND LETTER. PROVE INSTALLATION WITH WEIGHT TEST AND DEMONSTRATE MAN OVERBOARD DRILL.
Condition: Unknown
Due 24 March 2000
Resolved 24 March 2000
Navigation
Issued 9 December 1998
Resolved
Prove proper operation of depth sounder._x001C_
Condition: Unknown
Due 21 December 1998
Resolved 21 December 1998
Fire Fighting
Issued 9 December 1998
Resolved
Submit fire/safety plan for corrections and have new copies provided to vessel. Copy onboard has hand corrections and is satisfactory until corrected copy(ies) arrive. NOTE: Use IMO symbols._x001C_
Condition: Unknown
Due 31 December 1998
Resolved 31 December 1998
Construction/Loadline
Issued 9 December 1998
Resolved
Re-adjust both engine room escape hatches, difficult to dog and Focsle deckWTD, difficult to dog._x001C_
Condition: Unknown
Due 21 December 1998
Resolved 21 December 1998
Documentation
Issued 9 December 1998
Resolved
Provide/obtain International Tonnage Certificate as require by the International Convention, Tonnage Measurement of Ships, effective 01 July 1994, for vessel's engaged in foreign voyage, NVIC 11-93. _x001C_
Condition: Unknown
Due 21 December 1998
Resolved 21 December 1998
Engineering
Issued 9 December 1998
Resolved
Calibrate port and starboard shaft tachometers between engine room and pilot house._x001C_
Condition: Unknown
Due 21 December 1998
Resolved 21 December 1998
Construction/Loadline
Issued 8 September 1998
Resolved
VESSEL IS TO PROVIDE AND REPORT TO [name withheld], LA. THE NAME OF ESCORTVESSEL TO ACCOMPANY THIS VESSEL UNTIL MOORED AT DRYDOCKING FACILITY. VESSEL IS NOT TO MOVE WITHOUT ESCORT VESSEL.
Condition: Unknown
Due 9 October 1998
Resolved 8 October 1998
Construction/Loadline
Issued 8 September 1998
Resolved
VESSEL IS TO CLEAN, REMOVE CEMENT TANK COATINGS, AND PROVIDE GAS FREE CERTIFICATE FOR ALL TANKS, VOIDS AND COMPARTMENTS, AND MAKE VESSEL AVAILABLE FOR HULL AND INTERNAL STRUCTURAL EXAMINATIONS TO DETERMINE EXTENTOF WASTAGE.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Construction/Loadline
Issued 8 September 1998
Resolved
THIS VESSEL IS TO RE-SUBMIT INSPECTION FOR CERTIFICATION REQUEST. THIS CURRENT INSPECTION IS HEREBY TERMINATED.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Construction/Loadline
Issued 8 September 1998
Resolved
PRIOR TO EFFECTING ANY REPAIRS OF ALTERATIONS TO AREAS INSIDE THE WATERTIGHT ENVELOPE, INCLUDING MAIN DECK, SUBMIT REPAIR PROPOSAL
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Construction/Loadline
Issued 8 September 1998
Resolved
VSL IS TO PROCEED DIRECTLY TO EMERGENCY DRYDOCK. [name withheld] IS TO BE NOTIFIED WHEN VSL IS IN DRYDOCK. PRIOR TO ANY REPAIRS, A FULL ABS SURVEY OFTHE UNDERWATER PORTIONS OF THE VSL AND A COMPLETE INTERNAL STRUCTURAL EXAM SHALL BE COMPLETED, AND A REPORT SENT TO MSO NEW ORLEANS FOR REVIEW.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Construction/Loadline
Issued 8 September 1998
Resolved
VESSEL IS TO REPORT BOW THRUSTER CASUALTY IN ACCORDANCE WITH 46 CFR 126.110.
Condition: Unknown
Due 8 September 1998
Resolved 8 September 1998
Navigation
Issued 24 September 1996
Resolved
REPAIR RECORDING FATHOMETER TRACER AND PROVE PROPER OPERATION.
Condition: Unknown
Due 24 October 1996
Resolved 12 December 1996
Deck/Cargo
Issued 24 September 1996
Resolved
REPAIR AND PROVE OPERATION OF DRY BULK COMPRESSOR UNLOADER.
Condition: Unknown
Due 24 October 1996
Resolved 12 December 1996
Engineering
Issued 24 September 1996
Resolved
REPAIR AND TEST ALL ALARM SENSORS IN AIR OPERATED SYSTEM TO ALARM PANAL IN ENGINE ROOM. TO INCLUDE GENERATORS, MAIN ENGINES,START AND CONTROL AIR, BILGE ALARMS, PILOT HOUSE PANAL, ETC. VESSEL MUST MAINTAIN AN ENGINE ROOM WATCH AT ALL TIMES WHILE UNDERWAY.
Condition: Unknown
Due 24 October 1996
Resolved 12 December 1996
Documentation
Issued 24 September 1996
Resolved
DETERMINE WHY ABS LOADLINE REFERANCES A COAST GUARD STABILITY LETTER DATED 09FEB84 VICE 25JAN82. IF THE 1984 LTR IS DETERMINED TO BE CORRECT PROVIDE THE LETTER AND ANY REFERANCED REQUIRED BOOKLETS OR CURVES.
Condition: Unknown
Due 24 October 1996
Resolved 12 December 1996
Unknown
Issued 24 September 1996
Resolved
REPAIR PILOT HOUSE BOWTHRUSTER REMOTE STARTING SYSTEM AND PROVE OPERATION.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Engineering
Issued 24 September 1996
Resolved
REPAIR BOTH SHAFT RPM SENDING UNITS AND GAUGES IN PILOT HOUSE AND ENGINE ROOM.
Condition: Unknown
Due 24 October 1996
Resolved 12 December 1996
Construction/Loadline
Issued 23 January 1996
Resolved
CROP AND RENEW OUTBOARD BULKHEADS IN BOTH PORT/STARBOARD CHAIN LOCKERS.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Construction/Loadline
Issued 23 January 1996
Resolved
MAKE REPAIRS TO VESSEL AS PER ABS SURVEY REPORT DATED 19JAN96.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Construction/Loadline
Issued 23 January 1996
Resolved
CROP AND RENEW FORWARD BULKHEADS IN BOTH PORT/STARBOARD CHAIN LOCKERS.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Deck/Cargo
Issued 23 January 1996
Resolved
REPLACE WASTED PROTECTIVE SCREEN ON BLOWERS (MACHINERY SPACE EXHAUST) IN STARBOARD COMPRESSOR ROOM.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Construction/Loadline
Issued 23 January 1996
Resolved
UPON COMPLETION OF VESSEL PAINTING, REPAINT DRAFT MARKS AND RE-LABEL ALL VENTS.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Accommodation/Occupational Safety
Issued 23 January 1996
Resolved
REPLACE LADDER TO STARBOARD CHAIN LOCKER.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Construction/Loadline
Issued 23 January 1996
Resolved
CROP AND RENEW TO GOOD METAL THE DEEP WEBS IN THE ROPE LOCKER.
Condition: Unknown
Due 23 January 1996
Resolved 23 January 1996
Construction/Loadline
Issued 23 September 1994
Resolved
CROP AND RENEW WASTED LONGITUDINAL ON PORT RUDDER HOUSING,(FWD AND AFT OF HOUSING).
Condition: Unknown
Due 23 September 1994
Resolved 23 September 1994
Lifesaving
Issued 23 September 1994
Resolved
REMOVE OR REPAIR ALL ELECTRICAL AND/OR PNEUMATIC CONTROLS IN PUMP HOUSE (DOG HOUSE). (WATER PROOF ELECTRICAL JUNCTION BOXES, WIRING, ETC.)
Condition: Unknown
Due 23 September 1994
Resolved 23 September 1994
Documentation
Issued 23 September 1994
Resolved
SUBMIT CURRENT FIRE AND SAFETY PLAN TO [name withheld] FOR APPROVAL, (SUBMIT THREE COPIES).
Condition: Unknown
Due 23 September 1994
Resolved 23 September 1994
Documentation
Issued 23 September 1994
Resolved
PROVIDE COPY OF 33 CFR 01-199 AND LIFESAVING DISTRESS SIGNAL PLACARD FOR BRIDGE.
Condition: Unknown
Due 23 September 1994
Resolved 23 September 1994
Lifesaving
Issued 23 September 1994
Resolved
REPLACE WATER HEATER RELEIF VALVE WITH ASME PRESSURE/TEMP RELEIF RATED AT LESS THAN OR EQUAL TO 100 PSI AND 210 DEGREES (F).
Condition: Unknown
Due 23 September 1994
Resolved 23 September 1994
Lifesaving
Issued 23 September 1994
Resolved
INSTALL PRESSURE REDUCING REGULATOR ON CONTROL AIR RECEIVER IN FWD TUNNEL. RECEIVER HAS MAWP OF 165#; AIR SUPPLY IS 180+ PSI. REINSTALL 165 PSI RELEIFAFTER INSTALLING REGULATOR.
Condition: Unknown
Due 23 September 1994
Resolved 23 September 1994
Lifesaving
Issued 8 December 1993
Resolved
REPLACE BATTERY IN EPIRB.
Condition: Unknown
Due 8 December 1993
Resolved 8 December 1993
Engineering
Issued 8 December 1993
Resolved
FREE-UP OR REPLACE UNIVERSAL JOINT ON REACH ROD TO BILGE PIPING IN BOWTHRUSTER COMPARTMENT.
Condition: Unknown
Due 8 December 1993
Resolved 8 December 1993
Accommodation/Occupational Safety
Issued 11 October 1992
Resolved
MAKE PERMANENT REPAIRS TO P-TRAP ON SINK LOCATED IN COMMON HEAD ON SECOND DECK.
Condition: Unknown
Due 11 October 1992
Resolved 11 October 1992
Navigation
Issued 11 October 1992
Resolved
PROVIDE UPDATED NAUTICAL PUBLICATIONS AND COPIES OF APPLICABLE CFRS (46 CFR97.05-5).
Condition: Unknown
Due 11 October 1992
Resolved 11 October 1992
Accommodation/Occupational Safety
Issued 11 October 1992
Resolved
MAKE PERMANENT REPAIRS TO DRYER EXHAUST DUCT TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 11 October 1992
Resolved 11 October 1992
Deck/Cargo
Issued 11 October 1992
Resolved
CLEAN AND GAS FREE ALL INTEGRAL CARGO TANKS FOR INTERNAL EXAM (P-TANKS) AS REQUIRED BY 46 CFR 61.10-5 (a) AND (b) NO LATER THAN NEXT DRYDOCK EXAM.
Condition: Unknown
Due 11 October 1992
Resolved 11 October 1992
Electrical
Issued 11 October 1992
Resolved
REPLACE WIRING ON EMERGENCY SHUTDOWN MAINDECK, STARBOARD SIDE.
Condition: Unknown
Due 11 October 1992
Resolved 11 October 1992
Engineering
Issued 11 October 1992
Resolved
PROVE PROPER OPERATION OF PORT MAIN ENGINE OVERSPEED.
Condition: Unknown
Due 11 October 1992
Resolved 11 October 1992
Engineering
Issued 11 October 1992
Resolved
REPAIR LOWER DAY TANK OUTLET (CLOSE NIPPLE). PORT LOWER DAY TANK.
Condition: Unknown
Due 11 October 1992
Resolved 11 October 1992
Engineering
Issued 11 October 1992
Resolved
ENSURE PROPER OPERATION OF PORT F/O (PNEUMATIC) SHUT-DOWN. DIRECTLY BELOW PORT DAY TANK OUTLET.
Condition: Unknown
Due 11 October 1992
Resolved 11 October 1992
Engineering
Issued 11 October 1992
Resolved
PROVE PROPER OPERATION OF HI LUBE OIL TEMPERATURE ALARMS ON FORWARD SHIPS SERVICE GENERATOR AND #2 MAIN ENGINE. ENSURE PROPER TEST MEDIUMS ARE AVAILABLE (GLYCOL MIXTURE).
Condition: Unknown
Due 11 October 1992
Resolved 11 October 1992
Documentation
Issued 11 October 1992
Resolved
LOCATE AND POST STABILITY LETTER DATED 25 JAN 82 (MOBMS) IN THE PILOT HOUSE46 CFR 97.11-1
Condition: Unknown
Due 11 October 1992
Resolved 11 October 1992
Engineering
Issued 16 October 1991
Resolved
REPAIR AND DEMONSTRATE OPERATION OF BOTH GENERATOR ALARM PANELS. UNTIL_x001C_ PANEL HAS BEEN REPAIRED, VSL TO PROVIDE A MANNED CONTINOUS WATCH._x001C_ VSL'S MASTER AND CH. ENGINEER TO WITNESS REPAIRS AND SYSTEM OPERATIONAL TEST, ENTER INTO LOG AND FORWARD STATEMENT TO [name withheld].
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Fire Fighting
Issued 16 October 1991
Resolved
SERVICE AND HYDROSTATICALLY TEST BOTH SCBA CYLINDERS, HYDRO DATES CURRENTLYEXCEED FIVE (5) YEAR INTERVAL._x001C_ PROVIDE A COPY OF THE SERVICING REPORT TO [name withheld].
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Lifesaving
Issued 16 October 1991
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF ENGINEROOM SPACE GENERAL ALARM STATION CONTACTOR.
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Electrical
Issued 16 October 1991
Resolved
REPAIR, TEST & DEMONSTRATE PROPER OPERATION OF BOTH (#1) ELECTRICAL GENERATORS OVERSPEED DEVICE TRIPS._x001C_ VSL'S MASTER & CH. ENGINEER TO WITNESS OPERATION, MAKE AN OFFICAL LOG ENTRYIN VSL'S LOG AND FORWARD STATEMENT TO [name withheld]._x001C_
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Electrical
Issued 16 October 1991
Resolved
REPAIR OIL LEAKS (OIL SEALS) ON THE #2 GENERATOR CONTROL GOVERNOR._x001C_ VSL'S MASTER AND CH. ENGINEER TO WITNESS REPAIRS AND LOG RESULTS IN VSL'S OFFICAL LOG, AND FORWARD A STATEMENT TO THE [name withheld].
Condition: Unknown
Due 16 October 1991
Resolved 16 October 1991
Documentation
Issued 23 January 1991
Resolved
PROVIDE A COPY OF THE ABS SURVEY REPORT (INCLUDING GUAGING REPORT) AND NEW LOADLINE CERTIFICATE TO MARINE SAFETY OFFICE NEW ORLEANS, LA., ATTENTION INSPECTION DEPARTMENT._x001C_ _x001C_
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Documentation
Issued 23 January 1991
Resolved
SUBMIT STABILITY INFORMATION BOOKLET WHICH CONTAINS INFORMATION ON DISPERSANT TANK INSTALLED ON STBD SIDE OF DECK HOUSE, FOR REVIEW AND APPROVAL._x001C_ _x001C_
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Construction/Loadline
Issued 23 January 1991
Resolved
REPAIR OR REPLACE PORT ENGINEROOM ESCAPE HATCH COVER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Deck/Cargo
Issued 10 October 1990
Resolved
CLEAN AND GAS FREE , 4 P-TANKS, FOR INTERNAL INSPECTION. ID'S 25823, 25824,25825, 25826. TO BE COMPLETED AT THE NEXT DRYDOCK OF VESSEL BUT NOT LATER THAN 31JAN91.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Electrical
Issued 17 October 1989
Resolved
INSTALL AND TEST OVERSPEEDS ON BOTH, FORWARD AND AFT, GENERATORS. LETTER SIGNED BY MASTER AND [name withheld] TO SATISFACTORY TEST REQUIREDTO CLEAR THIS ITEM.
Condition: Unknown
Due 17 October 1989
Resolved 17 October 1989
Electrical
Issued 10 October 1988
Resolved
RENEW SHUT DOWN SWITCH FOR STBD BLOWER SHUT-DOWN LOCATED ON 02 LEVEL.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Engineering
Issued 10 October 1988
Resolved
REPAIR AS NECESSARY LOW LUBE OIL ALARM ON BOTH MAIN ENGINES.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Navigation
Issued 10 October 1988
Resolved
REPAIR/REPLACE ALARM FOR LOSS OF STEERING CURRENT.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Fire Fighting
Issued 10 October 1988
Resolved
HYDRO TEST & SERVICE ALL CO2 FIRE EXTINGUISHERS AS NEEDED.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Construction/Loadline
Issued 10 October 1988
Resolved
RENEW SCREENS ON BALLAST TANK VENTS AS NEEDED.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Navigation
Issued 10 October 1988
Resolved
REPAIR AUTO PILOT
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Navigation
Issued 10 October 1988
Resolved
REPAIR STBD RADAR.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Lifesaving
Issued 10 October 1988
Resolved
RENEW AS REQUIRED ALL LIFEJACKET LITES.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Construction/Loadline
Issued 10 October 1988
Resolved
PAINT LOADLINE ON HULL PS REQUIRED.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Deck/Cargo
Issued 10 October 1988
Resolved
RENEW HYDRALIC HOSE ON ANCHOR WINCH.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Construction/Loadline
Issued 10 October 1988
Resolved
PLACE "CHAIN/GUARD" ON PORT/STBD FORWARD BIB.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Deck/Cargo
Issued 10 October 1988
Resolved
INSTALL SECURING BOLTS ON ALL LIQUID MUD MAN HOLE COVERS.
Condition: Unknown
Due 10 October 1988
Resolved 10 October 1988
Fire Fighting
Issued 1 October 1987
Resolved
PROVIDE TWO (2) FIREMAN'S OUTFITS FOR VESSEL.
Condition: Unknown
Due 1 October 1987
Resolved 1 October 1987
Lifesaving
Issued 1 October 1987
Resolved
PERFORM ANNUAL SERVICING OF LIFERAFTS, TO BE COMPLETED BY 15 NOVEMBER 1987.
Condition: Unknown
Due 1 October 1987
Resolved 1 October 1987
Unknown
Issued 31 March 1987
Resolved
PROVIDE UL LISTED STOVE & REFRIGERATOR FOR THE UPPER GALLEY.
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Unknown
Issued 31 March 1987
Resolved
PRIOR TO PLACING THE UPPER GALLEY IN SERVICE, PROVIDE APPROVED PLANS FOR THE INSTALLATION.
Condition: Unknown
Due 31 March 1987
Resolved 31 March 1987
Electrical
Issued 23 October 1986
Resolved
PROVIDE UL LISTED STOVE & REFRIGERATOR FOR THE UPPER GALLEY.
Condition: Unknown
Due 23 October 1986
Resolved 23 October 1986
Documentation
Issued 23 October 1986
Resolved
PRIOR TO PLACING THE UPPER GALLEY IN SERVICE, PROVIDE APPROVED PLANS FOR THE INSTALLATION.
Condition: Unknown
Due 23 October 1986
Resolved 23 October 1986
Unknown
Issued 5 December 1985
Resolved
PROVIDE ONBOARD THE VESSEL A STANDARD DISCHARGE CONNECTION AS REQUIRED BY 33CFR155.430.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Unknown
Issued 5 December 1985
Resolved
MAKE AVAILABLE FOR INTERNAL EXAMINATION THE PORT AND STARBOARD AFT DRY BULKPRESSURE TANKS.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Documentation
Issued 5 December 1985
Resolved
PLACE ON BOARD THE VESSEL THE USCG APPROVED TRIM AND STABILITY BOOK DATED 09FEB84.
Condition: Unknown
Due 5 December 1985
Resolved 5 December 1985
Electrical
Issued 17 January 1985
Resolved
PROVIDE EMERGENCY LIGHTS IN THE FOLLOWING LOCATIONS PORT AND STARBOARD ENGINE ROOM ESCAPE TRUNKS STAIRWAY FROM MAIN DECK TO SECOND DECK.
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985
Unknown
Issued 17 January 1985
Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL, HAMILTON TIDE, DN644526
Condition: Unknown
Due 17 January 1985
Resolved 17 January 1985