Records from 1982 to 1986. Most recent: inspection, 30 June 1986.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Lifesaving
Issued 10 September 1985
Resolved
EQUIP EACH LIFEBOAT WITH ONE (1) ADDITIONAL SMOKE DISTRESS SIGNAL.
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985
Electrical
Issued 10 September 1985
Resolved
REPAIR OR REPLACE EMERGENCY LIGHT UNIT MOUNTED ON #2 LIFEBOAT STATION.
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985
Electrical
Issued 10 September 1985
Resolved
REPLACE MISSING BOLTS OF THREE (3) CONTROL BOXES ON DRILL FLOOR.
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985
Electrical
Issued 10 September 1985
Resolved
PROVIDE EYS FITTINGS ON P.A. HORN AND TELEPHONE, ELECTRICAL CONNECTIONS IN MUD PITS.
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985
Electrical
Issued 10 September 1985
Resolved
INSTALL TACHOMETER ON EMERGENCY GENERATOR AND TEST OVERSPEED TO ENSURE PROPER OPERATION.
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985
Documentation
Issued 10 September 1985
Resolved
RENEW CERTIFICATE OF FINANCIAL RESPONSIBILITY AND PLACE ABOARD RIG.
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985
Electrical
Issued 10 September 1985
Resolved
INSTALL INSULATED MATS OR GRATING BEHIND MAIN SWITCHBOARDS.
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985
Unknown
Issued 10 September 1985
Resolved
PROVIDE PROPER IDENTIFICATION FOR GENERAL ALARM BELL IN PORT P-TANK ROOM.
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985
Electrical
Issued 10 September 1985
Resolved
DRAIN BATTERY STORAGE BOX FOR GENERAL ALARM SYSTEM AND CLEAN ALL TERMINALS.
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985
Electrical
Issued 10 September 1985
Resolved
INSTALL EYS FITTING ON P.A. HORN LOCATED IN SHALE SHAKER AREA.
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985
Fire Fighting
Issued 10 September 1985
Resolved
RESERVICE OR REPLACE PORTABLE FIRE EXTINGUISHER IN #2 LIFEBOAT
Condition: Unknown
Due 10 September 1985
Resolved 10 September 1985
Construction/Loadline
Issued 10 August 1984
Resolved
MAKE MUD PIT DOORS SELF CLOSING AND REWORK ALL DOGS.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Lifesaving
Issued 10 August 1984
Resolved
PLACE THE FOLLOWING EQUIPMENT IN BOTH BOATS: FISHING KIT; TABLE OF LIFE- SAVING SIGNALS.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Lifesaving
Issued 10 August 1984
Resolved
REPLACE FUEL IN BOTH BOATS.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Lifesaving
Issued 10 August 1984
Resolved
CONDUCT A DRILL WITH THE LINE THROWING GUN AND PROPERLY LOG.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Fire Fighting
Issued 10 August 1984
Resolved
PROVIDE ONE ADDITIONAL OXYGEN METER FOR USE WITH THE FIREMAN'S OUTFIT.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Navigation
Issued 10 August 1984
Resolved
DEMONSTRATE PROPER OPERATION OF THE STERN LIGHT.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Electrical
Issued 10 August 1984
Resolved
LABEL ALL STOP/START SWITCHES.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Construction/Loadline
Issued 10 August 1984
Resolved
REPAIR SENSING DEVICES ON WATERTIGHT DOORS.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Accommodation/Occupational Safety
Issued 10 August 1984
Resolved
REPAIR MUD PIT VENTILATION LOSS ALARM.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Fire Fighting
Issued 10 August 1984
Resolved
CONDUCT A FIRE DRILL.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 10 August 1984
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE PONCA, DN649258
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Electrical
Issued 10 August 1984
Resolved
DEMONSTRATE PROPER OPERATION OF PURGE ALARM LIGHT FOR DRAWWORKS MOTOR.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Lifesaving
Issued 10 August 1984
Resolved
INSTALL ADDITIONAL GRATING IN WAY OF LIFEBOATS SO AS TO PROVIDE FOR IN- CREASED SAFETY OF PERSONNEL WHILE BOARDING.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Fire Fighting
Issued 10 August 1984
Resolved
SUBMIT COPY OF FIREFIGHTING EQUIPMENT SERVICING REPORT TO THE [name withheld], TEXAS.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 10 August 1984
Resolved
REPLACE THE PORT CRANE FUEL HOSE.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Lifesaving
Issued 10 August 1984
Resolved
REPLACE ALL LIFE JACKET LIGHT BATTERIES.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Documentation
Issued 10 August 1984
Resolved
PROVIDE ON BOARD A COAST GUARD APPROVED HAZARDOUS LOCATION PLAN.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Documentation
Issued 10 August 1984
Resolved
PROVIDE ON BOARD A COAST GUARD APPROVED CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Electrical
Issued 10 August 1984
Resolved
INSTALL AND POUR AN EYS FITTING ON THE GAS DETECTOR AT THE SHALE SHAKER LEVEL.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Electrical
Issued 10 August 1984
Resolved
INSTALL AND POUR AN EYS FITTINGS ON THE PORT MID LEVEL INDICATOR IN MUD PITS.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Fire Fighting
Issued 10 August 1984
Resolved
REPAIR THE GENERAL ALARM BELL ON THE PORT JACK HOUSE.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Fire Fighting
Issued 10 August 1984
Resolved
RENEW HOSE RACK ON FIRE STATION #2.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Construction/Loadline
Issued 10 August 1984
Resolved
REMOVE LOCKING DEVICES ON WATERTIGHT DOORS.
Condition: Unknown
Due 10 August 1984
Resolved 10 August 1984
Unknown
Issued 8 September 1983
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE PONCA, DN649258.
Condition: Unknown
Due 8 September 1983
Resolved 8 September 1983
Unknown
Issued 8 September 1983
Resolved
PLACE THE APPROVED COPY OF THE INFORMATION AND OPERATING INSTRUCTION MANUALABOARD THE VESSEL.
Condition: Unknown
Due 8 September 1983
Resolved 8 September 1983
Unknown
Issued 8 September 1983
Resolved
REPLACE THE FOUR DETERIORATED RING LIFE BUOYS.
Condition: Unknown
Due 8 September 1983
Resolved 8 September 1983
Unknown
Issued 8 September 1983
Resolved
PLACE ONE ADDITIONAL PARACHUTE FLARE IN THE PORT LIFEBOAT.
Condition: Unknown
Due 8 September 1983
Resolved 8 September 1983
Unknown
Issued 8 September 1983
Resolved
PROVIDE ONE QUART OF ILLUMINATING OIL FOR THE LANTERN IN THE STARBOARD LIFEBOAT.
Condition: Unknown
Due 8 September 1983
Resolved 8 September 1983
Unknown
Issued 8 September 1983
Resolved
DEMONSTRATE THE PROPER OPERATION OF THE EMERGENCY GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 8 September 1983
Resolved 8 September 1983
Unknown
Issued 8 September 1983
Resolved
PROVIDE EVIDENCE THAT THE DRAW WORKS CONSOLE HAS BEEN APPROVED FOR HAZARDOUS LOCATIONS.
Condition: Unknown
Due 8 September 1983
Resolved 8 September 1983
Unknown
Issued 8 September 1983
Resolved
REPAIR THE INOPERATIVE GENERAL ALARM BELLS OUTSIDE THE STARBOARD DECKHOUSE,AT THE SHALE SHAKER, ON THE DRILL FLOOR AND IN THE MUD PIT ROOM.
Condition: Unknown
Due 8 September 1983
Resolved 8 September 1983
Documentation
Issued 6 August 1982
Resolved
PROVIDE ONBOARD THE UNIT AN APPROVED CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 6 August 1982
Resolved 6 August 1982