Records from 1982 to 2009. Most recent: inspection, 7 May 2009.
Inspection history · 39
7 May 2009
PII Safety Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3469861
29 August 2002
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1668147
11 October 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1074906
24 September 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1075238
27 August 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1072759
23 July 2001
Re-Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1413966
8 June 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1050575
13 August 1999
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1113022
26 August 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 798253
16 June 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 762496
14 June 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 193485
13 June 1998
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419959
4 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1119032
1 August 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1413225
4 June 1996
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448770
15 August 1995
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1446232
21 July 1995
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1371121
8 July 1995
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1193493
6 May 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 57766
6 May 1995
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1344905
7 June 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401882
7 June 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 828021
5 May 1993
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459004
11 April 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 159915
2 July 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1262076
12 May 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 950152
10 March 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 102217
12 April 1991
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1214408
9 July 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 920301
24 May 1990
COI Inspection · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 931746
8 May 1990
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1231758
18 April 1989
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1210206
26 October 1988
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 890761
2 September 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1349673
24 May 1988
Hull Examination · MARPOL Annex II Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1338328
18 May 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012188
18 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973372
28 July 1982
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 964877
29 April 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 966808
Engineering
Issued 27 August 2001
Resolved
PROVE PROPER OPERATION OF THE OILY WATER SEPARATOR PRIOR TO USE. INSTALLATION AND TESTING SHALL BE TO THE SATISFACTION OF THE ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 27 August 2001
Resolved 27 August 2001
Navigation
Issued 23 July 2001
Resolved
REPAIR RUDDER ANGLE INDICATOR LOCATED ON THE BRIDGE
Condition: Unknown
Due 23 July 2001
Resolved 14 August 2001
Lifesaving
Issued 23 July 2001
Resolved
COMPLETE THE INSTALLATION AND TESTING OF THE NEW SUITABLE WORK BOAT (RESCUEBOAT)
Condition: Unknown
Due 23 July 2001
Resolved 14 August 2001
Engineering
Issued 23 July 2001
Resolved
INSTALL MISSING EXHAUST LAGGING ON THE PORT AND STBD MAIN DIESEL ENGINES
Condition: Unknown
Due 23 July 2001
Resolved 14 August 2001
Lifesaving
Issued 23 July 2001
Resolved
INSTALL GUARDS ON ALL ROTATING MACHINERY LOCATED IN THE ENGINEROOM
Condition: Unknown
Due 23 July 2001
Resolved 14 August 2001
Electrical
Issued 23 July 2001
Resolved
INSTALL ELECTRICAL SAFETY MAT IN FRONT OF THE GENERATOR SWITCHBOARD
Condition: Unknown
Due 23 July 2001
Resolved 14 August 2001
Accommodation/Occupational Safety
Issued 23 July 2001
Resolved
COMPLETED REPAIRS TO THE GALLEY, MESS DECK AND ACCOMMODATION SPACES
Condition: Unknown
Due 23 July 2001
Resolved 14 August 2001
Engineering
Issued 23 July 2001
Resolved
COMPLETE TEST OF THE AIR OPERATED EMERGENCY FUEL SHUTDOWN VALVES
Condition: Unknown
Due 23 July 2001
Resolved 14 August 2001
Construction/Loadline
Issued 23 July 2001
Resolved
INSTALL MISSING GAGE GLASS ON THE PORT AND STBD LUBE OIL DAY TANKS
Condition: Unknown
Due 23 July 2001
Resolved 14 August 2001
Engineering
Issued 23 July 2001
Resolved
RENEW NR. 2 AIR COMPRESSOR
Condition: Unknown
Due 23 July 2001
Resolved 14 August 2001
Electrical
Issued 23 July 2001
Resolved
RENEW MISSING GLOBE AND GUARD ON THE LIGHT LOCATED ABOVE THE NR. 2 MAIN ENGINE
Condition: Unknown
Due 23 July 2001
Resolved 14 August 2001
Fire Fighting
Issued 23 July 2001
Resolved
COMPLETE HYDRO TEST OF FIRE MAIN SYSTEM
Condition: Unknown
Due 23 July 2001
Resolved 14 August 2001
Engineering
Issued 21 July 1995
Resolved
Clean above the starboard engine, the exhaust blanket of excess oil._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 July 1995
Resolved 21 July 1995
Deck/Cargo
Issued 21 July 1995
Resolved
Clean and make safe for entry for a USCG Marine Inspector, all of vessels dry bulk (P-tanks) tanks.
Condition: Unknown
Due 21 July 1995
Resolved 21 July 1995
Navigation
Issued 21 July 1995
Resolved
Renew or repair ESPCO radar/anntena. Resolution is starting to deteriorate.
Condition: Unknown
Due 21 July 1995
Resolved 21 July 1995
Construction/Loadline
Issued 21 July 1995
Resolved
Renew bottom longitudinals as needed, located in port and starboard side ofsteering compartment.
Condition: Unknown
Due 21 July 1995
Resolved 21 July 1995
Electrical
Issued 21 July 1995
Resolved
Repair starboard bridge battery box to corrosion and no longer weather tight.
Condition: Unknown
Due 21 July 1995
Resolved 21 July 1995
Lifesaving
Issued 5 May 1993
Resolved
PROVIDE SUITABLE RESCUE BOAT FOR OCEANS ROUTE, TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993
Engineering
Issued 12 May 1992
Resolved
DEMONSTRATE PROPER OPERATION OF PORT MAIN ENGINE OVERSPEED TRIP.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Electrical
Issued 12 May 1992
Resolved
INSTALL ADDITIONAL BATTERY OPERATED EMERGENCY LIGHT IN FWD PORTION OF ENGINE ROOM. INSTALL LIGHT AS TO ILLUMINATE FWD DOOR IN ENGINE ROOM.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Deck/Cargo
Issued 12 May 1992
Resolved
MAKE ALL DRY BULK TANKS AVAILABLE FOR INTERNAL INSPECTION TO SATISFACTION OF ATTENDING USCG INSPECTOR AT NEXT VESSEL DRYDOCKING.
Condition: Unknown
Due 12 May 1992
Resolved 12 May 1992
Unknown
Issued 24 May 1990
Resolved
SUBMIT INFORMATION REGARDING "BACK-DOWN WINCH" TO USCG MARINE SAFETY CENTERFOR POSSIBLE RECALCULATION OF STABILITY.
Condition: Unknown
Due 24 May 1990
Resolved 24 May 1990
Unknown
Issued 2 September 1988
Resolved
PROVIDE ADDITIONAL PORTABLE FIRE EXTINGUISHERS TO COMPLY WITH THE COI AND 46 CFR 95.50-10(A) FOR A TOTAL OF SEVEN (7) B-II, TWO (2) A-II AND ONE (1) C-II.
Condition: Unknown
Due 2 September 1988
Resolved 2 September 1988
Unknown
Issued 18 May 1984
Resolved
INSTALL ON BOARD AN APPROVED FIRST AID KIT.
Condition: Unknown
Due 18 May 1984
Resolved 18 May 1984
Lifesaving
Issued 18 May 1984
Resolved
SERVICE BOTH LIFERAFTS PRIOR TO AUGUST 1984.
Condition: Unknown
Due 18 May 1984
Resolved 18 May 1984
Unknown
Issued 18 May 1984
Resolved
REPAIR THE EMERGENCY REMOTE FUEL OIL VALVE.
Condition: Unknown
Due 18 May 1984
Resolved 18 May 1984
Unknown
Issued 18 May 1984
Resolved
INSTALL APPROVED RELIEF VALVES ON THE CLUTCH AIR TANK, THE MSD COMPRESSION TANKS AND THE BULK DRY MUD CONTROLS AIR TANKS
Condition: Unknown
Due 18 May 1984
Resolved 18 May 1984
Unknown
Issued 18 May 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE M/V PBR/357, O.N. 643475.
Condition: Unknown
Due 18 May 1984
Resolved 18 May 1984