MAURY USCG vessel records Sign in
← All vessels

JULIENNE MARIE

JULIENNE MARIE is a 1981 passenger vessel (inspected). The Coast Guard has recorded 51 inspections since 1981, most recently in October 2017, along with 87 deficiencies — 1 with no resolution recorded —.

Records from 1981 to 2017. Most recent: inspection, 12 October 2017.

Built
1981
Last inspected
12 October 2017
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC5566
Flag
UNITED STATES
367043040 (licence lapsed)
Maury page id
psix-53500

Inspections, by type

…with no type recorded10
Years with a record 33 calendar years (1981–2017)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC5566MMSI 367043040 · expired · compulsorily equipped · granted 15 April 2015, cancelled 21 June 2025
WCY4340MMSI not assigned · expired · compulsorily equipped · granted 4 June 1998, cancelled 9 August 2008
WCX5647MMSI not assigned · expired · compulsorily equipped · granted 23 June 1997, cancelled 25 August 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

PAPOOSE Towing Vessel · MISLE 54658 · 14 January 1996 · activity 147275

Inspection history · 51

12 October 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6286259
13 November 2015 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5763134
11 June 2012 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4337368
2 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200513
15 July 2009 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3534583
28 August 2008 Examination of Repairs · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3311281
17 May 2007 Examination of Repairs · Hull Examination · Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2933254
21 June 2006 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2687417
11 May 2005 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2374813
27 April 2005 Re-Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2344461
5 August 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2156864
31 October 2003 In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1946477
6 May 2003 Internal Structural Exam · Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1787496
18 March 2003 In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1759020
9 May 2002 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1616263
17 May 2001 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452810
11 January 2001 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1056513
17 May 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469623
19 May 1999 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408302
13 May 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1378382
10 December 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1112926
28 May 1997 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1438585
6 June 1996 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1380534
27 May 1996 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1085490
14 January 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 147275
14 January 1996 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 874634
10 November 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 4265
26 May 1995 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1398257
11 August 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1440838
2 June 1994 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 70725
2 June 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 215745
22 October 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 849943
23 August 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401744
23 August 1993 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403662
23 September 1992 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 935126
20 March 1992 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 945850
7 November 1991 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1467814
7 November 1990 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1211366
13 December 1989 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 930476
3 November 1989 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1217770
8 June 1989 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205705
13 December 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1344878
4 November 1988 COI Inspection · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1207986
12 November 1987 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1331672
27 October 1986 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322926
19 October 1985 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989836
16 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1284790
13 October 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1274598
4 May 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963658
18 October 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970178
28 December 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970001

Deficiency record · 87

Lifesaving › Lifefloat › Serviceable
Issued 13 November 2015 No resolution recorded
Repair or replace 12 person life float. Reduced count of total persons allowed on board to 50 until completed to the satisfaction of the attending marine inspector prior to conducting commercial operations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Stability › Watertight Integrity › General
Issued 13 November 2015 Resolved
Repair watertight door leading from aft deck to accomadation space.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2015
Resolution: Vessel's crew repaired the watertight door.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 November 2015 Resolved
Repair or replace guards for rotating machinery on port and starboard main engines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2015
Resolution: Vessel's crew installed guards for both engines.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 13 November 2015 Resolved
Provide sufficent lighting for emergency escape from rudder room.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 December 2015
Resolution: Battle lantern battery was replaced and vessel's crew added another light that runs off of emergency power.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 11 June 2012 Resolved
Vsl had no compass deviation table on board.
Due 18 June 2012
Resolved 12 June 2012
Resolution: Vsl rep emailed a new compass deviation table for the vsl.
Engineering › Compressed Air System (control) › Valve
Issued 11 June 2012 Resolved
Vsl had old and painted pressure relief valves.
Condition: Improper/Lack of Maintenance
Due 18 June 2012
Resolved 12 June 2012
Resolution: Vsl rep installed new pressure relief valves for air receivers.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 11 June 2012 Resolved
SOLAS tape on lifebuoys need to be replaced.
Condition: Improper/Lack of Maintenance
Due 18 June 2012
Resolved 11 June 2012
Resolution: Vsl replaced SOLAS tape on lifebuoys that had worn tape.
Communications › Public Address System › Amplifier
Issued 15 July 2009 Resolved
Demonstrate proper operation of PA System
Due 21 August 2009
Resolved 21 July 2009
Resolution: PA system working properly
Communications › Audible Communications › Bell
Issued 15 July 2009 Resolved
Bell had no clapper. Install clapper on bell or replace bell.
Action required: 705 - Other - as specified
Resolved 21 July 2009
Resolution: Clapper replaced on bell.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 15 July 2009 Resolved
Provide proper Not Under Command lights prior to operation in restricted visibility
Action required: 705 - Other - as specified
Resolved 21 July 2009
Resolution: Proper Not Under Command lights on board
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 15 July 2009 Resolved
Replace missing and damaged lagging on all main diesel engines exhaust
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2009
Resolution: Lagging replaced
Engineering › Fuel Oil Service System › Ventilation
Issued 15 July 2009 Resolved
Replace flame screens in fuel vents
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2009
Resolution: Flame screens replaced
Engineering › Fuel Oil Service System › Filter
Issued 15 July 2009 Resolved
Place plugs in petcocks on fuel filters
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2009
Resolution: Plugs placed in petcocks
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 28 August 2008 Resolved
Washbasin inoperable
Action required: 705 - Other - as specified
Resolved 6 October 2008
Resolution: Removed from vessel
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 28 August 2008 Resolved
Smoke detectors did not work
Action required: 705 - Other - as specified
Resolved 6 October 2008
Lifesaving › Buoyant Apparatus › Float Free
Issued 28 August 2008 Resolved
Float free system not lined up correctly
Action required: 705 - Other - as specified
Resolved 6 October 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 August 2008 Resolved
Anchor light and starboard running light inoperable
Action required: 705 - Other - as specified
Resolved 6 October 2008
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 28 August 2008 Resolved
Lifebuoy mnissing retro reflective material
Action required: 705 - Other - as specified
Resolved 6 October 2008
Lifesaving › Buoyant Apparatus › Approval
Issued 28 August 2008 Resolved
Provide service report for buoyant apparatus addressing rippling of the float
Action required: 705 - Other - as specified
Resolved 6 October 2008
Resolution: Recieved report from Xtreme Pressue Services, Inc
Navigation › Piloting/Steering › Marine Charts
Issued 28 August 2008 Resolved
Vessel missing charts
Action required: 705 - Other - as specified
Resolved 6 October 2008
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 28 August 2008 Resolved
Overspeeds for both generators inop.
Action required: 705 - Other - as specified
Resolved 6 October 2008
Resolution: Witnessed operational test of new overspeeds
Construction/Loadline › Hull › Hull Plating
Issued 28 August 2008 Resolved
Crop and renew hull/watertight bulkhead port side in lazarette, due to unknown impact damage.
Action required: 705 - Other - as specified
Resolved 28 August 2008
Fire Fighting › Fire Pumps › Pressure
Issued 17 May 2007 Resolved
Fire pump pressue gauge reading between 50-55 psi. Minimum fire pump pressure required is 60 psi.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 June 2007
Resolution: Installed a new fire pump. Tested water pressure was 70 PSI.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 17 May 2007 Resolved
Install additional emergency light in engine room pointing towards egress.
Due 14 June 2007
Resolved 20 July 2007
Resolution: Installed sufficient emergency lighting in E/R.
Fire Fighting › Means of Escape › Emergency Lighting
Issued 17 May 2007 Resolved
Replace/repair emergency light in water closet.
Due 7 June 2007
Resolved 20 July 2007
Resolution: Renewed water closet emergency lighting.
Documentation › Certificates/Documents › FCC SSL
Issued 17 May 2007 Resolved
Provide proper FCC documentation w/ corrected call signs.
Due 30 June 2007
Resolved 20 July 2007
Resolution: Provided proper FCC documentation.
Documentation › Logs/Records › Logbook (official)
Issued 17 May 2007 Resolved
Provide proper fire/ abandon ship drill logs.
Due 14 June 2007
Resolved 20 July 2007
Resolution: Provide proper emergency drill logs.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 May 2007 Resolved
Provide Not Under Command lights.
Due 14 June 2007
Resolved 20 July 2007
Resolution: Provided Not Under Command Lights.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 17 May 2007 Resolved
Provide compass deviation table.
Due 21 June 2007
Resolved 20 July 2007
Resolution: Provided Compass Deviation Table.
Navigation › Piloting/Steering › Marine Charts
Issued 17 May 2007 Resolved
Provide updated charts per LNM.
Due 14 June 2007
Resolved 20 July 2007
Resolution: Updated charts as per LNM.
Stability › Watertight Integrity › General
Issued 17 May 2007 Resolved
Demonstrate proper operation of watertight door visual indicator.
Due 30 June 2007
Resolved 20 July 2007
Resolution: Watertight door indicator operable.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 17 May 2007 Resolved
Provide updated COLREGS/ Nav rules
Due 30 June 2007
Resolved 20 July 2007
Resolution: Provided COLREGS.
Engineering › Freshwater System (intermediary cooling) › Suction Strainer
Issued 17 May 2007 Resolved
Replace sea strainer on portside engine cooling system.
Due 30 June 2007
Resolved 20 July 2007
Resolution: Replaced sea strainer on portside E/R cooling system.
Operations/Management › Drills/Instruction › Fire
Issued 17 May 2007 Resolved
Perform fire, abandon ship drills in presence of attending marine inspector.
Due 30 June 2007
Resolved 20 July 2007
Resolution: Performed drills as per attending marine inspector instruction.
Electrical › Electric Generation Source (service) › Generator
Issued 10 August 2006 Resolved
Professionally clean stbd generator windings prior to sailing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2006
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 10 August 2006 Resolved
Provide FCC radio operator permits for master/mate.
Condition: Unknown
Due 10 September 2006
Resolved 21 July 2009
Resolution: Master on board had an FCC radio permit
Lifesaving › Rescue Boat › Boarding Ladder
Issued 10 August 2006 Resolved
Shorten rescue platform.
Condition: Improper Installation
Due 10 September 2006
Resolved 14 August 2006
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 10 August 2006 Resolved
Repair/replace inoperative lifefloat light.
Condition: Improper/Lack of Maintenance
Due 10 September 2006
Resolved 14 August 2006
Construction/Loadline › Structures › Door
Issued 10 August 2006 Resolved
Adjust dogs on fwd escape hatch.
Condition: Improper/Lack of Maintenance
Due 10 September 2006
Resolved 14 August 2006
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 August 2006 Resolved
Provide stanchions and chains for aft deck.
Condition: Improper/Lack of Maintenance
Due 10 September 2006
Resolved 14 August 2006
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 August 2006 Resolved
Provide guard for stbd main engine.
Condition: Improper Installation
Due 10 September 2006
Resolved 14 August 2006
Engineering › Fuel Oil Service System › Filter
Issued 10 August 2006 Resolved
Provide plugs for fuel filter petcocks.
Condition: Improper Installation
Due 10 September 2006
Resolved 14 August 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 August 2006 Resolved
Repair/replace leaking water valve above stbd generator.
Condition: Improper/Lack of Maintenance
Due 10 September 2006
Resolved 14 August 2006
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 10 August 2006 Resolved
Repair water leaks in port generator.
Condition: Improper/Lack of Maintenance
Due 10 September 2006
Resolved 14 August 2006
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 21 June 2006 Resolved
Repair short in SSB, prove proper radio check with Sector New Orleans.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2006
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 29 April 2005 Resolved
Demonstrate porper operation of generator room power ventilation blower.
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 9 May 2005
Resolution: Blower repaired - sat.
Engineering › Fuel Oil Service System › Hose
Issued 29 April 2005 Resolved
Provide proper SAE J-1942 approved fuel hoses for the supply and return lines on the port and stbd generators.
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 9 May 2005
Resolution: Hoses renewed with J-1942 approved hoses - see copy of hose specs included in case.
Electrical › Electric Supply System (service) › Battery Charger
Issued 29 April 2005 Resolved
Demonstrate porper operation of the battery charger located behind/beside the port generator.
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 9 May 2005
Resolution: Battery charger renewed.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 29 April 2005 Resolved
Demonstrate proper operation of the fuel transfer pump.
Action required: 705 - Other - as specified
Due 6 May 2005
Resolved 9 May 2005
Resolution: Fuel transfer pump repaired by S&H Marine - sat.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 August 2004 Resolved
Only one VHF radio operates properly. Show proper operation of both radios.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2004
Resolution: Radio repairman fixed radio.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 August 2004 Resolved
Provide flywheel casing cover on center main engine.
Due 5 September 2004
Resolved 5 August 2004
Resolution: Case cover installed.
Engineering › Fuel Oil Service System › Filter
Issued 5 August 2004 Resolved
Provide metal plug or petcocks which will accept metal plugs on racor filters.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2004
Resolution: Metal plugs installed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 5 August 2004 Resolved
Provide emergency lighting in engine room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2004
Resolution: Emergency lighting units installed.
Construction/Loadline › Structures › Door
Issued 5 August 2004 Resolved
Provide 4th dog on forward emergency escape hatch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2004
Electrical › Electrical Distribution System (service) › Panelboard
Issued 5 August 2004 Resolved
Renew breaker panel board and blower control box at stbd engine room blower. Both had severe corrosion.
Due 5 September 2004
Resolved 11 August 2004
Resolution: Panels renewed.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 May 2003 Resolved
Provide additional emergency lighting for emergency escapes in the forward head and rudder room.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 June 2003
Resolved 12 May 2003
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 9 May 2003 Resolved
Make repairs to both generator overspeed devices.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 June 2003
Resolved 12 May 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 9 May 2003 Resolved
Provide machinery guards for center and port main engines. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 17 - Rectify deficiencies prior to departure
Due 9 June 2003
Resolved 12 May 2003
Documentation › Markings/Placards
Issued 9 May 2003 Resolved
Provide MARPOL placard. LEGACY COMPONENT DESC: Garbage Placard
Action required: 705 - Other - as specified
Due 9 June 2003
Resolved 12 May 2003
Engineering › Fuel Oil Service System › Filter
Issued 9 May 2003 Resolved
Provide metal plugs for all fuel filters on main engines.
Action required: 705 - Other - as specified
Due 9 June 2003
Resolved 12 May 2003
Accommodation/Occupational Safety › Potable Water System
Issued 9 May 2003 Resolved
Provide bug screen for forward potable water tank vent. LEGACY COMPONENT DESC: Ventilation
Action required: 705 - Other - as specified
Due 9 June 2003
Resolved 12 May 2003
Fire Fighting › Portable Foam Applicators
Issued 9 May 2003 Resolved
Provide required fir fighting equipment for marine portable tanks. LEGACY COMPONENT DESC: Additional Fire Fighting Equipment
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 June 2003
Resolved 12 May 2003
Stability › Watertight Integrity
Issued 9 May 2003 Resolved
Make repairs to main deck watertight door. LEGACY COMPONENT DESC: Watertight Doors
Action required: 17 - Rectify deficiencies prior to departure
Due 9 June 2003
Resolved 12 May 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 9 May 2003 Resolved
Provide flame screen for sewage tank vent.
Action required: 705 - Other - as specified
Due 9 June 2003
Resolved 12 May 2003
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 9 May 2003 Resolved
Provide protective cover for Operating Station electrical panel.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 June 2003
Resolved 12 May 2003
Lifesaving › Buoyant Apparatus
Issued 9 May 2002 Resolved
Life Floats in poor condition. Renew drop down nets in all three floats. Renew exterior coating on one float. Patch hole in exterior coating of one float. LEGACY COMPONENT DESC: Life Floats
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2002
Resolved 10 May 2002
Resolution: Lifloats have all been serviced/reconditioned.
Communications › Audible Communications › Horn/Whistle
Issued 9 May 2002 Resolved
Install ships horn.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2002
Resolved 10 May 2002
Resolution: Installed a horn.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 9 May 2002 Resolved
Install 15 LB. CO2 extinguisher on paint locker. Locker is less than 200 cuft.
Action required: 705 - Other - as specified
Due 9 June 2002
Resolved 10 May 2002
Resolution: Installed portable CO2 on paint locker.
Engineering › Diesel Engine (propulsion-reduction gear) › Air-flex Clutch
Issued 9 May 2002 Resolved
Restore pilothouse control for main engines.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2002
Resolved 10 May 2002
Resolution: Repaired pilothouse control.
Construction/Loadline › Hull › Side Shell
Issued 9 May 2002 Resolved
Repair fractures in side shell in way of starboard generator exhaust.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2002
Resolved 10 May 2002
Resolution: Repaired with insert.
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 9 May 2002 Resolved
Adjust generator overspeed trips.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 June 2002
Resolved 10 May 2002
Resolution: Adjusted overspeed trips.
Electrical › Electrical Distribution System (service)
Issued 9 May 2002 Resolved
Remove all deadend wires in engine room. Properly suspend all other wires in engine room with metal ties. LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 10 May 2002
Electrical › Lighting (service)
Issued 9 May 2002 Resolved
Repair broken light fixtures in engine room and replace covers. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 10 June 2002
Electrical › Electrical Distribution System (service) › Panelboard
Issued 9 May 2002 Resolved
Repair door on electrical panel, starboard side aft in engine room.
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 10 May 2002
Stability › Watertight Integrity
Issued 9 May 2002 Resolved
Replace worn plastic balls in gooseneck vent and provide plugs for remaining vents. LEGACY COMPONENT DESC: Vents
Action required: 705 - Other - as specified
Due 7 June 2002
Resolved 10 May 2002
Construction/Loadline
Issued 17 May 2000 Resolved
INSTALL AND DEMONSTRATE BILGE ALARM PANEL IAW 46 CFR 182.530, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Navigation
Issued 17 May 2000 Resolved
PRIOR TO PROCEEDING MORE THAN 20NM OFFSHORE, AND PRIOR TO 16 JUNE 00 DEMONSTRATE PROPER OPERATION OF SSB RADIO, TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 17 May 2000
Resolved 24 May 2000
Navigation
Issued 17 May 2000 Resolved
INSTALL EXTERNAL RUDDER STOPS FOR THE PORT AND STBD RUDDERS AT THE NEXT DRYDOCKING.
Condition: Unknown
Due 17 May 2000
Resolved 17 May 2000
Lifesaving
Issued 17 May 2000 Resolved
DEMONSTRATE EMERGENCY DRILLS AND DOCUMENT FUTURE DRILLS TO THE SATISFACTIONOF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 17 May 2000
Resolved 24 May 2000
Engineering
Issued 17 May 2000 Resolved
REPAIR LEAK IN F/O TRANSFER PUMP SEAL, THE THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 17 May 2000
Resolved 24 May 2000
Lifesaving
Issued 7 November 1991 Resolved
Missing three lights on three pfd's._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Engineering
Issued 7 November 1991 Resolved
Noted tear in stbd rubber fuel line._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 November 1991
Resolved 7 November 1991
Documentation
Issued 13 December 1989 Resolved
OBTAIN & PLACE ON BOARD A COPY OF YOUR CURRENT STABILITY LETTER DTD 09JAN83.
Condition: Unknown
Due 13 December 1989
Resolved 13 December 1989
Engineering
Issued 4 November 1988 Resolved
MAKE PERMANENT REPAIRS TO TEMPORARY REPAIRS ON PORT M.D.E. EXHAUST PIPING.
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Engineering
Issued 4 November 1988 Resolved
PROVIDE ONE ELECTRIC BLOWER IN ENGINE ROOM TO REMOVE EXHAUST FROM THAT SPACE.
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Construction/Loadline
Issued 4 November 1988 Resolved
MARK EMERGENCY EXITS THROUGHOUT VESSEL.
Condition: Unknown
Due 4 November 1988
Resolved 4 November 1988
Accommodation/Occupational Safety
Issued 12 November 1987 Resolved
INSTALL A MARINE SANITATION DEVICE TYPE II OR TYPE III, THAT MEETS THE REQUIREMENTS OF 33 CFR PART 159.
Condition: Unknown
Due 12 November 1987
Resolved 12 November 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.