MAURY USCG vessel records Sign in
← All vessels

GOOD TIME DIVER II

GOOD TIME DIVER II is a 1981 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 1981, most recently in June 1997, along with 27 deficiencies.

Records from 1981 to 1997. Most recent: inspection, 11 June 1997.

Built
1981
Last inspected
11 June 1997
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WRA5298
Flag
UNITED STATES
—
Maury page id
psix-53506

Inspections, by type

…with no type recorded10
Years with a record 16 calendar years (1981–1997)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it28 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 34

11 June 1997 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1112098
26 March 1997 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1091721
10 March 1997 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1099757
7 June 1996 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1184610
20 February 1996 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1192352
2 June 1995 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1184709
18 October 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1183079
30 June 1994 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1175626
16 February 1994 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 854462
18 May 1993 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 841050
18 September 1992 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 938879
11 June 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 955179
3 June 1992 COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 946165
14 May 1992 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1268912
29 August 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1198992
18 June 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 891625
5 June 1991 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1251416
27 June 1990 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 925839
8 June 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1252845
11 May 1990 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1214160
21 June 1989 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1037361
22 December 1988 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1206935
11 May 1988 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1347391
10 March 1988 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1336488
15 June 1987 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1336452
7 May 1987 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1334477
28 April 1987 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1006351
16 December 1986 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1310365
2 July 1986 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1015747
22 April 1986 Credit Drydock · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1003234
16 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977968
19 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972900
25 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967787
21 December 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275230

Deficiency record · 27

Engineering
Issued 2 June 1995 Resolved
Provide proper guards over belts, FWD, STBD main engine.
Condition: Unknown
Due 2 July 1995
Resolved 30 June 1995
Lifesaving
Issued 2 June 1995 Resolved
Provide (1) addition adult PFD with light.
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Electrical
Issued 2 June 1995 Resolved
Remove old radar wiring on top of vessel house.
Condition: Unknown
Due 2 July 1995
Resolved 30 June 1995
Accommodation/Occupational Safety
Issued 2 June 1995 Resolved
Replace broken window STBD pilot house.
Condition: Unknown
Due 2 July 1995
Resolved 30 June 1995
Lifesaving
Issued 2 June 1995 Resolved
Provide an approved Ring Bouy with light & line.
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Engineering
Issued 2 June 1995 Resolved
Install proper (30 X 30 mesh) flame screen on fuel tank vents.
Condition: Unknown
Due 2 June 1995
Resolved 2 June 1995
Electrical
Issued 30 June 1994 Resolved
INSTALL MISSING GENERATOR GAUGES IN MACHINERY SPACE OR INSTALL COVER PLATESINWAY OF OPENING IN PANEL.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Lifesaving
Issued 30 June 1994 Resolved
PROVIDE SIX (6) ADDITIONAL ADULT LIFEJACKETS, VESSEL IS RESTRICTED TO A TOTAL OF 19 PERSONS ABOARD UNTIL COMPLIANCE.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Fire Fighting
Issued 30 June 1994 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, PLACE ONE ADDITIONAL BII FIRE EXTINGUISHER ABOARD FOR A TOTAL OF 3 BII.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Electrical
Issued 30 June 1994 Resolved
CLEAN UP DEADENDED CABLES AND REWIRE MAST.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Navigation
Issued 30 June 1994 Resolved
REBUSH STBD RUDDER QUADRANT.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Engineering
Issued 30 June 1994 Resolved
INSTALL PROPER FUEL TANK VENT HOSES AND FLAME SCREENS.
Condition: Unknown
Due 30 June 1994
Resolved 30 June 1994
Lifesaving
Issued 3 June 1992 Resolved
REPLACE 4 ADULT PFDS AND LIGHTS PLUS ADDITIONAL 6 PFD LIGHTS_x001C_ _x001C_ VESSEL LIMITED TO 15 TOTAL PERSONS UNTIL THIS ITEM IS CLEARED.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Navigation
Issued 3 June 1992 Resolved
REPAIR OR REPLACE MASTHEAD LIGHT
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Lifesaving
Issued 3 June 1992 Resolved
REPLACE ALL HAND HELD FLARES_x001C_
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Lifesaving
Issued 18 June 1991 Resolved
REFURBISH 12 PERSON LIFEFLOAT AS PER 46 CFR 160.027 AND 180.15
Condition: Unknown
Due 18 June 1991
Resolved 18 June 1991
Engineering
Issued 21 June 1989 Resolved
REMOVE LUBE OIL FROM ENGINE ROOM BILGE ACTUAL COMPLIANCE DATE: 28JUN89
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989
Lifesaving
Issued 21 June 1989 Resolved
PROVIDE WATERLIGHT FOR LIFE FLOAT ACTUAL COMPLIANCE DATE: 28JUN89
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989
Engineering
Issued 21 June 1989 Resolved
INSULATE EXHAUST LINE ON STARBOARD ENGINE ACTUAL COMPLIANCE DATE: 5JUL89
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989
Engineering
Issued 21 June 1989 Resolved
PLACE A GUARD OVER ROTATING BELTS ON STARBOARD ENGINE ACTUAL COMPLIANCE DATE: 5JUL89
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989
Navigation
Issued 21 June 1989 Resolved
PLACE ON BOARD ONE COPY OF THE INLAND NAVIGATION RULES AND SUBCHAPTER T REGULATIONS (46 CFR, PARTS 166-199) ACTUAL COMPLIANCE DATE: 5JUL89
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989
Construction/Loadline
Issued 21 June 1989 Resolved
PROVIDE CAPTIVE CHAIN FOR AFTER COMPARTMENT HATCH ACTUAL COMPLINACE DATE: 5JUL89
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989
Engineering
Issued 21 June 1989 Resolved
PLACE SECOND BILGE PUMP IN OPERATION IN ENGINE ROOM ACTUAL COMPLIANCE DATE: 5JUL89
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989
Engineering
Issued 21 June 1989 Resolved
PROVIDE POLLUTION PREVENTION PLACARD ON VESSEL ACTUAL COMPLIANCE DATE: 5JUL89
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989
Lifesaving
Issued 21 June 1989 Resolved
LABEL STORAGE LOCATION FOR CHILD SIZE PFD'S ACTUAL COMPLIANCE DATE: 5JUL89
Condition: Unknown
Due 21 June 1989
Resolved 21 June 1989
Accommodation/Occupational Safety
Issued 22 December 1988 Resolved
INSTALL A SUITABLE MARINE SANITATION DEVICE. TOILETS TO BE SECURED UNTIL THREE MILES FROM LAND UNTIL THIS ITEM COMPLETED.
Condition: Unknown
Due 22 December 1988
Resolved 22 December 1988
Electrical
Issued 15 June 1987 Resolved
REMOVE OR DEAD END ABANDONED ELECTRICAL CABLE IN ENGINE ROOM.
Condition: Unknown
Due 15 June 1987
Resolved 15 June 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.