MAURY USCG vessel records Sign in
← All vessels

INTREPID TIDE

INTREPID TIDE is a 1981 offshore supply vessel. The Coast Guard has recorded 30 inspections since 1981, most recently in January 1999, along with 46 deficiencies.

Records from 1981 to 1999. Most recent: inspection, 15 January 1999.

Built
1981
Last inspected
15 January 1999
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8115849 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WUU4837
Flag
UNITED STATES
—
Maury page id
psix-53511

Inspections, by type

…with no type recorded6
Years with a record 15 calendar years (1981–1999)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 27 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it296 - Regulatory (Subpart C or D), Gross Ton
713 - Convention (Subpart B), Gross Ton
201 - Regulatory (Subpart C or D), Net Ton
213 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WUU4837MMSI not assigned · cancelled · compulsorily equipped · granted 20 August 1998, cancelled 16 September 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 30

15 January 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 809564
28 June 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 176830
22 January 1998 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1467529
5 February 1997 Re-Inspection
Physical examination · Activities Europe · Activity 1359363
31 January 1997 Administrative
Administrative · Activities Europe · Activity 1103415
11 March 1996 Administrative
Administrative · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 884716
26 January 1996 COI Inspection · Hull Examination
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1363488
14 December 1995 Type not recorded
No type recorded · Activities Europe · Activity 112389
10 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 880385
13 July 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 861747
6 May 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1172795
21 January 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 852641
7 January 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 851168
6 November 1993 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1161565
18 August 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1158841
23 March 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 646342
1 March 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 838969
17 February 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1146835
6 December 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 950577
2 August 1991 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 942336
4 December 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1236355
24 November 1989 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 900780
4 December 1988 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 897441
4 December 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1209055
10 November 1988 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1208062
21 July 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1335940
22 October 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1010473
4 December 1985 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1304196
6 March 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1287258
18 December 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968033

Deficiency record · 46

Engineering
Issued 22 January 1998 Resolved
INSTALL MISSING BLANKING PLUG IN VALVE ON THE GEAR OIL TANK ON STBD SIDE OFENGINE ROOM.
Condition: Unknown
Due 23 January 1998
Resolved 2 February 1998
Construction/Loadline
Issued 22 January 1998 Resolved
COMPLETE WELD ON ENGINE ROOM SIDE OF PREVIOUS REPAIR TO DECK IN WAY OF PORTSIDE ENGINE ROOM ESCAPE HATCH.
Condition: Unknown
Due 23 January 1998
Resolved 2 February 1998
Navigation
Issued 22 January 1998 Resolved
REINSTALL MISSING COTTER PINS IN NUTS ON RUDDER CONTROL ARMS.
Condition: Unknown
Due 23 January 1998
Resolved 2 February 1998
Construction/Loadline
Issued 22 January 1998 Resolved
RENEW DECK PLATE WITH CUT OUT IN IT IN WAY OF STARBOARD PRELUBE PUMP.
Condition: Unknown
Due 23 January 1998
Resolved 2 February 1998
Lifesaving
Issued 22 January 1998 Resolved
REMOVE SPARE BATTERY STORED IN ENGINE ROOM IN WAY OF STARBOARD MDE.
Condition: Unknown
Due 23 February 1998
Resolved 2 February 1998
Engineering
Issued 22 January 1998 Resolved
EXTEND GUARD ON STARTER ON PORT MDE TO COVER ROTATING PINION GEAR.
Condition: Unknown
Due 23 January 1998
Resolved 2 February 1998
Accommodation/Occupational Safety
Issued 22 January 1998 Resolved
CLEAN AND SECURE LOSSE VENT SCREEN IN OVERHEAD IN ENGINE ROOM IN WAY OF FWDWATERTIGHT DOOR.
Condition: Unknown
Due 23 January 1998
Resolved 2 February 1998
Deck/Cargo
Issued 22 January 1998 Resolved
MAKE PERMANENT REPAIRS TO HOLE IN MUDLINE IN OVERHEAD IN WAY OF MUD PUMP INENGINE ROOM.
Condition: Unknown
Due 23 January 1998
Resolved 2 February 1998
Engineering
Issued 22 January 1998 Resolved
INSTALL MACHINERY GUARDS ON PROTRUDING AND ROTATING SHAFTS ON THE AIR CONTROLLERS FOR THE REDUCTION GEARS ON THE PORT AND STARBOARD MDE'S.
Condition: Unknown
Due 23 January 1998
Resolved 2 February 1998
Construction/Loadline
Issued 22 January 1998 Resolved
REMOVE EXCESSIVE OIL FROM BILGES IN BOW THRUSTER ROOM AND ENGINE ROOM.
Condition: Unknown
Due 23 January 1998
Resolved 2 February 1998
Construction/Loadline
Issued 5 February 1997 Resolved
RENEW AS NEEDED THE SPURLING PIPE IN THE STARBOARD CHAIN LOCKER.
Condition: Unknown
Due 30 November 1998
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 5 February 1997 Resolved
MAKE PERMANENT REPAIRS TO DAMAGED SWASH BULKHEADS (FIRST & SECOND BULKHEAD AFT) AND FORWARD WATERTIGHT BULKHEAD IN WAY OF SIDE SHELL ATTACHMENT.
Condition: Unknown
Due 30 November 1998
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 6 May 1994 Resolved
PROVIDE PROOF OF PURCHASE OF THREE LIFE JACKET LIGHTS.
Condition: Unknown
Due 6 May 1994
Resolved 6 May 1994
Lifesaving
Issued 6 May 1994 Resolved
PROVIDE PROOF OF PURCHASE OF TEN USCG APPROVED LIFE JACKETS.
Condition: Unknown
Due 6 May 1994
Resolved 6 May 1994
Deck/Cargo
Issued 6 November 1993 Resolved
REPLACE SHOTS #3,7,9, & 10 OF THE PORT ANCHOR CHAIN DUE TO MORE THAN 12 PERCENT WASTAGE.
Condition: Unknown
Due 6 November 1993
Resolved 6 November 1993
Deck/Cargo
Issued 6 November 1993 Resolved
REPLACE SHOTS #13 & 14 OF THE STBD ANCHORAGE CHAIN DUE TO MORE THAN 12 PERCENT WASTAGE.
Condition: Unknown
Due 6 November 1993
Resolved 6 November 1993
Navigation
Issued 17 February 1993 Resolved
INSTALL AND PROVE PROPER OPERATION OF STERN ANCHOR LIGHT.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Engineering
Issued 17 February 1993 Resolved
INSTALL ENGINEROOM VENTILATION SCREENS.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Fire Fighting
Issued 17 February 1993 Resolved
PROVIDE COAST GUARD APPROVED FIRE EXTINGUISHERS ON BOARD FOR ALL NON-COAST GUARD APPROVED FIRE EXTINGUISHERS.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Navigation
Issued 17 February 1993 Resolved
PROVIDE UP TO DATE NOTICE TO MARINERS TIDE AND CURRENT TABLES; 46 LFR 90- 139 AND 41-69; LIGHT LIST; CHARTS FOR OPERATING AREA; AND LOAD LINE REGULATIONS.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Electrical
Issued 17 February 1993 Resolved
REPAIR AFT TOW LIGHT IN PILOT HOUSE NAVIGATION PANEL. THE ABOVE ITEMS 1 THRU 12 ARE TO BE COMPLETED. FAX RESULTS TO [name withheld] FAX # [phone withheld].
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Lifesaving
Issued 17 February 1993 Resolved
REPLACE PORT LIFE RAFT WITH COAST GUARD SERVICED LIFERAFT AND INSTALL SERVICED HYDROSTATIC RELEASE. THE TOTAL PERSONS ALLOWED IN VESSEL WHILE UNDERWAY SHALL NOT EXCEED 10 UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Fire Fighting
Issued 17 February 1993 Resolved
UPDATE FIRE/SAFETY PLANS.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Fire Fighting
Issued 17 February 1993 Resolved
PROVIDE SPARE COAST GUARD APPROVED AIR CYLINDER FOR BREATHING APPARATUS.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Engineering
Issued 17 February 1993 Resolved
INSTALL EXHAUST BLANKETS FOR PORT AND STARBOARD MAIN DIESEL ENGINES.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Deck/Cargo
Issued 17 February 1993 Resolved
INSTALL AIR RELIEF HANDLES FOR STARBOARD AFT AND PORT AFT BULK TANK SAFETY RELIEF VALVES.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Documentation
Issued 17 February 1993 Resolved
PROVIDE OIL RECORD BOOK
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Deck/Cargo
Issued 17 February 1993 Resolved
REPLACE OIL SEAL ON ANCHOR WINDLASS.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Engineering
Issued 17 February 1993 Resolved
REPLACE INOPERATIVE BULBS IN THE PILOT HOUSE AND ENGINE ROOM AUTOMATION ALARM PANEL. ITEMS 1 THRU 15 ARE TO BE COMPLETED. FAX RESULTS TO [name withheld] FAX # [phone withheld].
Condition: Unknown
Due 1 December 1993
Resolved 1 December 1993
Fire Fighting
Issued 17 February 1993 Resolved
REPLACE ALL NON-COAST GUARD APPROVE FIRE EXTINGUISHERS ON B0ARD VESSEL WITHSERVICED CG APPROVED FIRE EXTINGUISHERS.
Condition: Unknown
Due 2 August 1993
Resolved 2 August 1993
Navigation
Issued 17 February 1993 Resolved
PROVIDE CURRENT CHARTS FOR OPERATING AREA; NOTICE TO MARINERS; LAW GOVERNING MARINE INSPECTION; 46 CFR 40 THRU 69 AND 90 THRU 139; LIGHT LIST;CURRENT TABLES; RULES OF THE ROAD AND MANEUVERING INFORMATION.
Condition: Unknown
Due 25 August 1993
Resolved 25 August 1993
Accommodation/Occupational Safety
Issued 10 November 1988 Resolved
RE-NEW DECK WINCH AIR RECEIVER 1/4", 250 PSI SET PRESSURE RELIEF VALVE.
Condition: Unknown
Due 10 November 1988
Resolved 10 November 1988
Unknown
Issued 10 November 1988 Resolved
PROVIDE [name withheld], NEW YORK WITH A COPY OF MIO SHIP BELT GUAGE REPORT TAKEN 11 NOVEMBER 1988.
Condition: Unknown
Due 10 November 1988
Resolved 10 November 1988
Documentation
Issued 10 November 1988 Resolved
PROVIDE AND PLACE ON BOARD SUITABLE FUEL OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 10 November 1988
Resolved 10 November 1988
Electrical
Issued 4 December 1985 Resolved
PROVE PROPER OPERATION OF THE #1 GENERATOR LOW LUBE OIL ALARM.
Condition: Unknown
Due 4 December 1985
Resolved 4 December 1985
Fire Fighting
Issued 4 December 1985 Resolved
PROVE PROPER OPERATION OF THE MAIN FIRE PUMP CONTACT SWITCH.
Condition: Unknown
Due 4 December 1985
Resolved 4 December 1985
Electrical
Issued 4 December 1985 Resolved
PROVE PROPER OPERATION OF THE #2 GENERATOR HIGH JACKET WATER TEMPERATURE ALARM SENSOR.
Condition: Unknown
Due 4 December 1985
Resolved 4 December 1985
Lifesaving
Issued 4 December 1985 Resolved
PROVIDE 12 COAST GUARD APPROVED HAND HELD FLARES (6 ORANGE SMOKE AND 6 RED NIGHT) CURRENTLY DATED.
Condition: Unknown
Due 4 December 1985
Resolved 4 December 1985
Electrical
Issued 4 December 1985 Resolved
PROVE PROPER OPERATION OF THE #1 GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 4 December 1985
Resolved 4 December 1985
Lifesaving
Issued 4 December 1985 Resolved
PROVIDE 2 COAST GUARD APPROVED SELF ACTIVATING BRIDGE SMOKE SIGNALS CURRENTLY DATED.
Condition: Unknown
Due 4 December 1985
Resolved 4 December 1985
Lifesaving
Issued 4 December 1985 Resolved
PROVIDE 12 COAST GUARD APPROVED RED ROCKET PARACHUTE FLARES CURRENTLY DATED.
Condition: Unknown
Due 4 December 1985
Resolved 4 December 1985
Navigation
Issued 6 March 1985 Resolved
PROVIDE NOTICE TO MARINERS AS APPROPRIATE TO ENABLE CHARTS AND PUBLICATIONSTO BE PROPERLY UPDATED.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Deck/Cargo
Issued 6 March 1985 Resolved
HYDROSTATICALLY TEST TO 1 1/4 MAWP VESSEL'S DIESEL WINCH STARTING AIR TANK-NATIONAL BOARD #347867.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Fire Fighting
Issued 6 March 1985 Resolved
PROVIDE 1 APPROVED COMBINATION FIRE HOSE NOZZLE FOR FIRE STATION #1, WHERE PRESENTLY MISSING.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Navigation
Issued 6 March 1985 Resolved
PROVIDE ONBOARD, A CURRENT COPY OF THE FOLLOWING: (A) 46 CFR 90-139 (B) 46 CFR 41-69 (C) 46 CFR 156-165.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Lifesaving
Issued 6 March 1985 Resolved
PROVIDE 6 C.G. APPROVED RING BUOYS TO REPLACE EXISTING RING BUOYS IN A STATE OF DISREPAIR.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985

Ownership record