Records from 1981 to 2002. Most recent: inspection, 8 April 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 34
8 April 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1602157
6 February 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1484318
28 July 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 153884
25 May 2001
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1063610
12 April 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1062291
21 March 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379348
14 June 2000
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1053273
2 June 2000
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1053247
1 April 2000
Drydock Extension · Re-Inspection · Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1440288
4 November 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 801785
25 October 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 792563
25 October 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1127202
8 September 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1119205
3 September 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1118129
21 June 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 880945
25 March 1999
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1378649
3 August 1998
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1434765
20 April 1998
Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1364744
7 April 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1368153
30 May 1996
Hull Examination · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1383266
11 April 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1377709
11 December 1995
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422608
7 April 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1463885
21 October 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358571
5 June 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 860633
29 June 1993
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 846222
4 June 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1445995
7 April 1993
COI Inspection · MARPOL Annex II Examination · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451880
18 March 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1143824
21 July 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1024739
11 January 1986
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1307513
11 December 1985
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 990799
6 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1285599
30 November 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967737
Fire Fighting › Fire Main
Issued 6 February 2002
Resolved
PRIOR TO SAILING PROPERLY REPAIR FIREMAIN PIPING IWO PUMP LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 6 February 2002
Resolved 7 February 2002
Engineering › Bilge Water Management System
Issued 6 February 2002
Resolved
PRIOR TO SAILING REPAIR FOREPEAK REACHROD LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Due 6 February 2002
Resolved 7 February 2002
Construction/Loadline › Structures
Issued 6 February 2002
Resolved
PROVIDE AND INSTALL FLAME SCREENS FOR ALL LIQUID MUD TANKS PRIOR TO TRANSFERRING CARGO LEGACY COMPONENT DESC: Ventilators
Condition: Improper/Lack of Maintenance
Due 6 February 2002
Resolved 6 February 2002
Navigation › Piloting/Steering
Issued 6 February 2002
Resolved
PROPERLY ALIGN ALL RUDDER ANGLE INDICATORS TO SHOW ACCURATE RUDDER ANGLE LEGACY COMPONENT DESC: RUDDER ANGLE INDICATOR
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2002
Resolved 7 February 2002
Construction/Loadline › Structures
Issued 6 February 2002
Resolved
PROPERLY ADJUST ENGINE ROOM EMERGENCY ESCAPE SCUTTLE LEGACY COMPONENT DESC: Scuttle
Condition: Improper/Lack of Maintenance
Due 6 February 2002
Resolved 7 February 2002
Pollution Prevention/Response › Prevention Equipment
Issued 6 February 2002
Resolved
PRIOR TO FUEL TRANSFER REPAIR ALL ENGINE ROOM EMERGENCY F/O STOPS TO INCLUDE CENTRIFUGE LEGACY COMPONENT DESC: EMERGENCY STOPS
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2002
Resolved 7 February 2002
Engineering › Shafting/Propeller Arrangements
Issued 6 February 2002
Resolved
PROPERLY PACK AND SEAL STBD SIDE STERN TUBE PACKING LEGACY COMPONENT DESC: Stern Tube Lubrication/Sealing
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 February 2002
Resolved 7 February 2002
Electrical
Issued 21 March 2001
Resolved
INSTALL 02 ADDITIONAL EMERGENCY EGRESS LIGHTS IN THE ENGINE ROOM TO PROPERLY ILLIMUNATE THE PORT EMERGENCY ESCAPE AND THE ESCAPE ROUTE.
Condition: Unknown
Due 21 March 2001
Resolved 21 March 2001
Fire Fighting
Issued 21 March 2001
Resolved
MAKE PERMANENT REPAIRS TO THE FIREMAIN PIPING. REPAIRS TO CONSIST OF RENEWING SECTION OF PIPING ON THE OUTPUT SIDE OF THE FIRE PUMP.
Condition: Unknown
Due 21 March 2001
Resolved 21 March 2001
Construction/Loadline
Issued 21 March 2001
Resolved
INSTALL SEPARATE BILGE HIGH WATER LEVEL SENSORS AND ASSOC LIGHTS FOR THE ENGINE ROOM FWD PASSAGE WAY AND THE RUDDER COMPARTMENT ALLEYWAY. LIGHTS ANDALARMS TO BE INSTALLED AT THE ENGINE ROOM AND PILOT HOUSE ALARM PANELS.
Condition: Unknown
Due 21 March 2001
Resolved 21 March 2001
Navigation
Issued 21 March 2001
Resolved
REPAIR ENGINE ROOM SOUND POWERED PHONE VISUAL / AUDIBLE CALL INDICATOR TO ALLOW OPERATION UNDER EMERGENCY POWER. 46 CFR 113.30-25 (E).
Condition: Unknown
Due 21 March 2001
Resolved 21 March 2001
Engineering
Issued 1 April 2000
Resolved
PROVE PROPER OPERATION OF SHAFT TACHS ON BOTH SHAFTS.
Condition: Unknown
Due 1 April 2000
Resolved 1 April 2000
Engineering
Issued 1 April 2000
Resolved
PROVE PROPER OPERATION OF PORT SIDE PROPULSION SYSTEM.
Condition: Unknown
Due 1 April 2000
Resolved 1 April 2000
Documentation
Issued 1 April 2000
Resolved
MAKE VESSEL AVAILABLE FOR DEF CHECK IN CONJUNCTION WITH THE COAST GUARD VISIT FOR THE M/V MARION TIDE.
Condition: Unknown
Due 1 April 2000
Resolved 1 April 2000
Engineering
Issued 1 April 2000
Resolved
PROVE REPAIRS TO EXCESS OIL LEAKS ON THE STBD MAIN AND THE #1 GENERATOR.
Condition: Unknown
Due 1 April 2000
Resolved 1 April 2000
Lifesaving
Issued 1 April 2000
Resolved
PROVIDE AND PROVE 42 PSI OR LESS POP-OFF VALVE FOR P-TANKS.
Condition: Unknown
Due 1 April 2000
Resolved 1 April 2000
Fire Fighting
Issued 1 April 2000
Resolved
CROP AND RENEW WASTED FIREMAIN LINE IN E/R. PROVE REPAIRS WITH HYDROSTATICTEST @ 150% OF MAX FIREMAIN PRESSURE.
Condition: Unknown
Due 19 April 2000
Resolved 19 April 2000
Construction/Loadline
Issued 1 April 2000
Resolved
VESSEL IS TO PROVIDE WRITTEN PROPOSAL TO EFFECT REPAIRS TO WASTED INBOARD BUKLKHEADS IN THE #3 PORT AND STBD TANKS. INCLUDE A STATEMENT AS TO WHETHER THE DRY DOCK WILL BE FOR CREDIT OR NON CREDIT.
Condition: Unknown
Due 1 April 2000
Resolved 19 April 2000
Construction/Loadline
Issued 1 April 2000
Resolved
UPON COMPLETION OF DRY DOCK REPAIRS, VESSEL IS TO SUBMIT A COPY OF ABS REPORT REGARDING SATISFACTORY PRESSURE TEST OF ALL WATERTIGHT BULKHEADS, PENETRATIONS, INSERTS AND PIPING SYSTEMS. SUBMIT REPORT BY FAX TO [phone withheld].
Condition: Unknown
Due 1 April 2000
Resolved 1 April 2000
Navigation
Issued 1 April 2000
Resolved
PROVIDE CURRENT COMPASS DEVIATION CARD.
Condition: Unknown
Due 1 April 2000
Resolved 1 April 2000
Engineering
Issued 1 April 2000
Resolved
PROVE PROPER OPERATION OF REMOTE SHUTDOWNS ON PORT AND STBD MAIN ENGINES.
Condition: Unknown
Due 1 April 2000
Resolved 1 April 2000
Lifesaving
Issued 1 April 2000
Resolved
CONDUCT MAN OVERBOARD DRILL IN THE PRESENCE OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 1 April 2000
Resolved 1 April 2000
Engineering
Issued 1 April 2000
Resolved
PROVIDE AND PROVE PROPER OPERATION OF RPM GUAGES FOR #1 AND #2 GENERATORS.
Condition: Unknown
Due 1 April 2000
Resolved 1 April 2000
Engineering
Issued 1 April 2000
Resolved
ADJUST AND PROVE PACKING ON STBD SHAFT.
Condition: Unknown
Due 1 April 2000
Resolved 1 April 2000
Documentation
Issued 25 March 1999
Resolved
PROVIDE UPDATED AND CORRECT FIRE AND SAFETY PLAN. PLAN IS TO BE SUBMITTED TO [name withheld] NEW CONSTRUCTION FOR VERIFICATION. THE HANDWRITTEN PLAN WHICH WAS VERIFIED BY THE ATTENDING MARINE INSPECTOR SHALL BE SUBMITTED WITH THE NEW PLAN FOR VERIFICATION OR NEW PLAN VERIFIED ONBOARD.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Lifesaving
Issued 25 March 1999
Resolved
VESSEL'S RESCUE BOAT HAS BEEN REPLACED - THEREFORE, VESSEL IS TO INSTALL THE DAVIT, CABLE, WINCH AND RELEASING HOOK REQUIRED BY COAST GUARD DISTRICTEIGHT POLICY LETTER #16613 DATED 12NOV98. COPY OF LETTER PROVIDED TO VESSEL.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Documentation
Issued 3 August 1998
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 August 1998
Resolved 10 August 1998
Electrical
Issued 20 April 1998
Resolved
INSTALL PROPER BREAKERS IN SWITCHBOARDS.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Electrical
Issued 20 April 1998
Resolved
PROVIDE CIRCUIT DIRECTORY FOR F/O SEPARATOR CONTROLLER.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Documentation
Issued 20 April 1998
Resolved
PROPERLY POST ALL REQUIRED
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Navigation
Issued 20 April 1998
Resolved
OBTAIN CURRENT COPY OF COAST PILOT FOR FOR GULF OF MEXICO AND LAKE MARACAIBO.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Fire Fighting
Issued 20 April 1998
Resolved
INSTALL APPROVED BRACKETS FOR CO2 EXTINGUISHERS THROUGHOUT VESSEL._x001C_
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Deck/Cargo
Issued 20 April 1998
Resolved
RENEW ANCHOR CHAINS PORT AND STARBOARD.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Engineering
Issued 20 April 1998
Resolved
REPLACE PORT TAILSHAFT
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Construction/Loadline
Issued 20 April 1998
Resolved
INSTALL SELF-CLOSING VALVE ON SOUNDING TUBE BESIDE AFT GENERATOR.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Construction/Loadline
Issued 20 April 1998
Resolved
INSTALL ALL BOLTS IN ALL MAN HOLE COVERS.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Construction/Loadline
Issued 30 May 1996
Resolved
SUBMIT REPAIR PROPOSAL TO [name withheld], LA. FOR, AND PROPERLY REPAIR HOLE IN #3P BALLAST TANK
Condition: Unknown
Due 30 May 1996
Resolved 30 May 1996
Deck/Cargo
Issued 7 April 1995
Resolved
MAKE DRY BULK CARGO P-TANKS AVAILABLE FOR INTERNAL EXAM AT NEXT SCHEDULED DRYDOCKING.
Condition: Unknown
Due 7 April 1995
Resolved 7 April 1995
Fire Fighting
Issued 5 June 1994
Resolved
PROVIDE ONE (1) FIRE HOSE TO MEET REQUIREMENT FOR FIVE 50' FIRE HOSES ON BOARD VESSEL.
Condition: Unknown
Due 5 June 1994
Resolved 5 June 1994
Electrical
Issued 5 June 1994
Resolved
REPLACE SIX GLOBES AND GUARDS ON LIGHTS WHERE MISSING.
Condition: Unknown
Due 5 June 1994
Resolved 5 June 1994
Lifesaving
Issued 5 June 1994
Resolved
PROVIDE TWO (2) RING BUOYS TO MEET REQUIREMENT FOR SIX RING BUOYS.
Condition: Unknown
Due 5 June 1994
Resolved 5 June 1994
Fire Fighting
Issued 4 June 1993
Resolved
Repair or replace the fire pump motor starter unit prior to departure from Port O'Connor, Texas._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 June 1993
Resolved 8 June 1993
Electrical
Issued 4 June 1993
Resolved
Remove the dead-ended 440 volt wiring from the shore power and engine room fan no.1 circuits on the main switchboard._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 June 1993
Resolved 8 June 1993
Engineering
Issued 4 June 1993
Resolved
Remove insulation from the starboard main diesel engine exhaust system in the starboard main deck locker, check for fractures and/or leaks, and make repairs as necessary._x001C_ _x001C_
Condition: Unknown
Due 4 June 1993
Resolved 4 June 1993
Electrical
Issued 4 June 1993
Resolved
Make permanent repairs to the 110 volt wiring bundle located in the starboard main deck locker (lighting & receptacles)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 June 1993
Resolved 8 June 1993
Construction/Loadline
Issued 11 December 1985
Resolved
AFT PEAK, STBD, SWASH PLATE, FRAME JUST AFT, AND DECK BRAKET ARE BUCKLED. CROP AND RENEW.
Condition: Unknown
Due 11 December 1985
Resolved 11 December 1985
Engineering
Issued 11 December 1985
Resolved
PROVIDE FOR HYDRO OF SHIP'S SERVICE AIR RECEIVERS IN LIEU OF INTERNAL EXAM.
Condition: Unknown
Due 11 December 1985
Resolved 11 December 1985
Construction/Loadline
Issued 11 December 1985
Resolved
T-PIPE FOR SUCTION SIDE OF BILGE AND BALLAST SYSTEM: VERTICAL PIPE IS HOLED; HORIZONTAL PIPE IS PITCH WELDED. CROP AND RENEW.
Condition: Unknown
Due 11 December 1985
Resolved 11 December 1985
Engineering
Issued 11 December 1985
Resolved
FORWARD AND AFT PASSAGEWAY SENSORS INOPERABLE. PROVIDE, INSTALL AND MAINTAIN LIVE WATCH UNTIL REPAIRED. [name withheld] IS TO BE NOTIFIED IN WRITING.
Condition: Unknown
Due 11 December 1985
Resolved 11 December 1985
Navigation
Issued 11 December 1985
Resolved
PROVIDE AND INSTALL RUDDER ANGLE INDICATOR FOR STEERING STATION IN ENGINE ROOM.
Condition: Unknown
Due 11 December 1985
Resolved 11 December 1985
Electrical
Issued 6 March 1985
Resolved
PROVIDE TEN (10) DRYCELL BATTERIES FOR EMERGENCY LIGHTING.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Lifesaving
Issued 6 March 1985
Resolved
SERVICE PORT INFLATABLE LIFEREAFT (SWITLIK USCG APPROVAL # 160.051/56/0 SER# SPCMM 17 10 PERSON OCEAN) AT A U.S. COAST GUARD APPROVED FACILITY.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Construction/Loadline
Issued 6 March 1985
Resolved
REPAIR PORT AND STBD ENGINE ROOM ESCAPE HATCHWAY TO BE A WATERTIGHT DOOR.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985