Inspection history · 21
14 July 2026
DAPI Audit
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8438654
27 August 2025
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8217460
26 September 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8014541
26 July 2024
COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7965806
20 June 2024
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7939026
31 August 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7780988
18 October 2022
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7571520
19 August 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7542193
12 July 2022
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7504865
19 August 2021
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7290135
10 December 2020
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7108857
20 July 2020
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 7011126
26 June 2020
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7007162
10 October 2019
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6832012
17 September 2019
In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6813000
23 July 2019
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6733084
9 August 2018
Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6513671
30 July 2018
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6474487
25 August 2017
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6247063
12 July 2016
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5938154
22 June 2016
Simplified Stability Test · Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5917575
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 July 2026
Resolved
EAP program - Supervisors did not have 60 minutes of training ISAW 46CFR16.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 August 2026
Resolved 16 July 2026
Resolution: DER provided EAP 60 minutes supervisor training certificate to MSU IO.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 July 2026
Resolved
Employee was hired withouht completing a Pre-employment Chemical test IAW 46CFR16.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 July 2026
Resolved 14 July 2026
Resolution: Past event that can not be fixed at a later date. DER was educated and will follow regulations moving forward.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 July 2026
Resolved
New hire working in a safety sensitive position with no return to duty letter from the SAP after known positive chemical test.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 July 2026
Resolved 14 July 2026
Resolution: Educated DER on regulations after known postive chemical test result.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 August 2025
Resolved
Noted an exhaust leak in engine room. Required leak to be located and repaired
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2025
Resolved 10 September 2025
Resolution: Exhaust was repaired, O/O to provide reciept.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 18 October 2022
Resolved
The vessels fire pump was inoperable. Issued requirement to show proper operation.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 17 November 2022
Resolved 2 November 2022
Resolution: Fixed.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 October 2022
Resolved
02 smoke detectors were inoperable. Crew replaced batteries while on board.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2022
Resolved 18 October 2022
Resolution: Fixed on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 October 2022
Resolved
The bilge pumping system is controlled by the fire pump. Therefore as the fire pump was inop, so was the bilge system. Issued requirement to show proper operation prior to movement.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 17 November 2022
Resolved 2 November 2022
Resolution: Fixed.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 18 October 2022
Resolved
The EPIRB hydrostatic release was expired. Issued requirement to install a new one and provide proof. Vessel restricted to within 3nm.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2022
Resolved 2 November 2022
Resolution: Replaced
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 October 2022
Resolved
The vessel had just come from the yards and the inspection ports for the forepeak were removed. As such, the emergency escape ladder from the overnight berthing was removed. Issued requirement to show proper operation of emergency escape prior to the carriage of overnight pax.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 November 2022
Resolved 2 November 2022
Resolution: Proved.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 18 October 2022
Resolved
Vessel was missing ammonia inhalants from first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2022
Resolved 2 November 2022
Resolution: Replaced.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 18 October 2022
Resolved
Drills (MOB/Fire/Abandon Ship) had not been documented on board since August 2021. Issued requirement to conduct drills prior to the carriage of pax/crew.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 November 2022
Resolved 2 November 2022
Resolution: Conducted and logged.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 19 August 2021
Resolved
Repair cracked weld on port rudder stop.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2021
Resolved 24 August 2021
Resolution: MI attended vessel and noted repair was made.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 August 2021
Resolved
Place loose wiring into existing stuffing tubes on battery charger in engineroom.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2021
Resolved 24 August 2021
Resolution: MI attended vessel and noted wires had been placed into stuffing tubes.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 August 2021
Resolved
Secure battery cover in engineroom.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2021
Resolved 24 August 2021
Resolution: MI attended vessel and noted cover was secured.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 19 August 2021
Resolved
Properly fix IBA painter line to hydrostatic release.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 19 August 2021
Resolved 19 August 2021
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 September 2019
Resolved
46CFR176.810: Minor leaks were observed on the discharge side of the common bilge/fire main within the machinery space, discharge volume was not affected. O/O removing fire main from service and replacing in kind, vessel has secondary fire pump system.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 17 September 2019
Resolved 19 September 2019
Resolution: O/O replaced in kind, demonstrated operational readiness to sat. of attending MI
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 17 September 2019
Resolved
46 CFR 177.15-1: Means of escape; re-route air conditioning duct that obstructs egress from below deck hatchway
Condition: Design Flaw
Action required: 60 - Rectify deficiencies prior to movement
Due 17 September 2019
Resolved 27 September 2019
Resolution: O/O re-reouted AC ducts
09 - Working and Living Conditions › 091 - Living Conditions › Access/structure
Issued 17 September 2019
Resolved
46 CFR 185.606: Escape hatches and emergency exits; properly label with EMERGENCY EXIT, KEEP CLEAR
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 17 September 2019
Resolved 27 September 2019
Resolution: O/O properly labeled Escape access
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 17 September 2019
Resolved
60: Flammability rating for mattresses; O/O could not provide proof of meeting either allowable standard
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 18 September 2019
Resolved 20 November 2019
Resolution: Installed approved mattresses.
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 17 September 2019
Resolved
60: O/O installed new bulkhead materials iwo cooking area; request clarification from O/O to flame spread rating
Action required: 60 - Rectify deficiencies prior to movement
Due 17 September 2019
Resolved 17 October 2019
Resolution: Witnessed installed bulkhead materials iwo cooking area rated to prevent flame spread.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 September 2019
Resolved
46 CFR 176.500/46 CFR176.806: If no proof of approval can be provided for updated bridge nav. safety installations then provide line drawing to OCMI
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2019
Resolved 17 October 2019
Resolution: Conducted review of electrical installation that has been redone under console for bridge electronics. All wiring and associated circuit protection have been made to the approved type.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 17 September 2019
Resolved
46 CFR 185.520-524/46 CFR 185.420: Provide records for crew training (Abandon ship, MOB, Fire Fighting, Rough Weather, EPIRB testing etc...)
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 October 2019
Resolved 17 October 2019
Resolution: Witnessed vessel training and logs.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 September 2019
Resolved
33 CFR 155.1055/33 CFR 155.1060: Provide records of training and exercises for Vessels Non-Tank Vessel Response Plan
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019
Resolved 17 October 2019
Resolution: Witnessed use of NTVRP.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 17 September 2019
Resolved
33 CFR 155.700: Update PIC list for Vessel Transfer Proceduresg
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2019
Resolved 17 October 2019
Resolution: Witnessed updated transfer procedures and PIC.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 July 2019
Resolved
Renew retro reflective material on starboard life ring.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 31 July 2019
Resolution: Renewed retro reflective material on starboard life ring.
04 - Emergency Systems › N/A - No Subsystem › Low level lighting in corridors
Issued 23 July 2019
Resolved
Repair/ replace lighting fixture on stairway to berthing.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 31 July 2019
Resolution: Repaired lighting fixture on stairway to berthing.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 23 July 2019
Resolved
Renew expired medications in first aid kit.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2019
Resolved 31 July 2019
Resolution: Renewed expired medications in first aid kit.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 12 August 2016
Resolved
Provide smoke detector for master's state room.
Due 12 September 2016
Resolved 15 August 2016
Resolution: Smake detector installed.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 12 August 2016
Resolved
Remove excessive oil containers from engine room.
Due 12 September 2016
Resolved 15 August 2016
Resolution: Excessive oil containers removed.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 August 2016
Resolved
Repair light fixture in steering space.
Due 12 September 2016
Resolved 15 August 2016
Resolution: Fixture repaired.
Engineering › Fuel Oil Service System › Valve, Control
Issued 12 August 2016
Resolved
Label emergency fuel shut offs.
Due 12 September 2016
Resolved 15 August 2016
Resolution: Fuel shut offs labeled.
Engineering › Bilge Water Management System › Strainer
Issued 12 August 2016
Resolved
Provide strainer for steering compartment bilge suction.
Due 12 September 2016
Resolved 15 August 2016
Resolution: Strainer installed.
Communications › Alarms/Indicators › Bilge Alarm
Issued 12 August 2016
Resolved
Lower engine room bilge high water alarm float switch.
Due 12 September 2016
Resolved 15 August 2016
Resolution: Float switch lowered.
Communications › Public Address System › Loudspeaker
Issued 12 August 2016
Resolved
Repair mess deck P/A speaker.
Due 12 September 2016
Resolved 15 August 2016
Resolution: Speaker repaired.