Records from 1982 to 1998. Most recent: inspection, 3 December 1998.
Inspection history · 47
3 December 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 805724
29 November 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 805438
1 September 1998
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 797459
14 July 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 793953
18 April 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 5079
18 February 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1113520
9 February 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 774652
31 October 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 782718
26 September 1997
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1431865
22 October 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419683
6 March 1996
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385654
5 December 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1432988
16 November 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 876322
26 September 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1374397
18 October 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1436917
5 April 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 665622
13 January 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 132776
5 October 1993
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373925
17 September 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 665619
3 September 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 16562
15 June 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 684838
23 March 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 96099
11 February 1993
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1414108
20 July 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 957313
13 July 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1261114
23 December 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1268565
1 February 1991
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 995464
19 March 1990
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1237527
3 January 1990
COI Inspection · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1244150
30 March 1989
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1201354
2 March 1989
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1197143
25 August 1988
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1348038
5 February 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1326839
25 January 1988
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1018408
17 February 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1014865
6 February 1987
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1329320
18 February 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 997861
24 January 1986
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294065
25 April 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1286652
19 March 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1287571
5 March 1985
Damage Survey
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1304320
19 January 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 971671
6 October 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1277921
18 April 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283263
24 January 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1277959
25 November 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1272314
20 January 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1274313
Electrical
Issued 1 September 1998
Resolved
MAINTAIN A CONSTANT FIRE WATTCH UNTIL MAIN ELECTRICAL BOARD IS REPAIRED.
Condition: Unknown
Due 6 September 1998
Resolved 4 September 1998
Electrical
Issued 1 September 1998
Resolved
SECURE MAIN ELECTRICAL BOARD UNTIL CLASS SOECITY HAS ATTESTED TO THE CG THAT PROPER REPAIRS HAVE BEEN MADE.
Condition: Unknown
Due 6 September 1998
Resolved 4 September 1998
Fire Fighting
Issued 26 September 1997
Resolved
REPLACE WODDEN DECKING ON COMPANION WAY WALKWAY WITH PROPER DECKING MATERIAL.
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Fire Fighting
Issued 26 September 1997
Resolved
RENEW TO ORIGINAL, POSITION LOCKING PLATE ON PORT UPPER FIRE MONITOR.
Condition: Unknown
Due 26 September 1997
Resolved 26 September 1997
Unknown
Issued 26 September 1995
Resolved
Submit to OCMI modifications to "engine room alarm system manual" to provide procedures for testing the sentinel low oil pressure and high watertemperature shutdown device.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Engineering
Issued 26 September 1995
Resolved
Prove proper operation of port pressure vessel relief valve.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Deck/Cargo
Issued 26 September 1995
Resolved
Make 1-4 dry bulk tanks available for CG inspection.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Navigation
Issued 3 January 1990
Resolved
PROVE PROPER OPERATION OF PORT AND STARBOARD SHAFT TACHOMETERS IN ACCORDANCE WITH REFERENCE NVIC 1-78.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Engineering
Issued 2 March 1989
Resolved
REPAIR CRACK IN STARBOARD MAIN JACKET WATER CASING.
Condition: Unknown
Due 2 March 1989
Resolved 2 March 1989
Navigation
Issued 2 March 1989
Resolved
REPAIR PORT RADAR.
Condition: Unknown
Due 2 March 1989
Resolved 2 March 1989
Lifesaving
Issued 25 January 1988
Resolved
RENEW BLOCKS TO RESCUE BOAT FALLS.
Condition: Unknown
Due 25 January 1988
Resolved 25 January 1988
Deck/Cargo
Issued 25 January 1988
Resolved
RENEW OIL TRANSFER PUMP HOSE AND FITTINGS.
Condition: Unknown
Due 25 January 1988
Resolved 25 January 1988
Navigation
Issued 24 January 1986
Resolved
MAKE REPAIRS TO RUDDER ANGLE INDICTOR IN WHEELHOUSE.
Condition: Unknown
Due 24 January 1986
Resolved 24 January 1986
Engineering
Issued 19 March 1985
Resolved
TEST THE REMOTE SHUTDOWN STARBOARD MAIN ENGINE.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Construction/Loadline
Issued 19 March 1985
Resolved
AT THE NEXT DRYDOCK AIR TEST THE PORT AND STARBOARD POTABLE WATER TANKS ANDCHECK ALL JOINTS FOR LEAKS. CHECK ALL BULKHEADS FOR EXCESSIVE DISTORTION DUE TO OVER PRESSURIZING.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Electrical
Issued 19 March 1985
Resolved
MAKE SUITALBE REPAIRS TO THE MAIN GENERATOR SWITCHBOARD DOOR FOR PROPER CLOSING AND SECURING OF DOOR.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Fire Fighting
Issued 19 March 1985
Resolved
PROPERLY LABEL THE ENGINE ROOM CO2 LOCAL AND REMOTE PULLS AND PROVIDE OPERATING DIRECTIONS FOR EACH.
Condition: Unknown
Due 19 March 1985
Resolved 19 March 1985
Unknown
Issued 19 January 1984
Resolved
MAKE ALL AIR RECEIVERS AVAILABLE FOR INTERNAL EXAMINATION OR CONDUCT A HYDROSTATIC TEST IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 19 January 1984
Resolved 19 January 1984
Unknown
Issued 19 January 1984
Resolved
THE FOLLOWING DEFICIENCY IS FOR THE GULF FLEET NO. 49, DN644168.
Condition: Unknown
Due 19 January 1984
Resolved 19 January 1984