Records from 1982 to 1992. Most recent: inspection, 19 May 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
19 May 1992
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 947987
18 May 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 943620
18 May 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 948434
17 September 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 936980
29 August 1991
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1247305
27 June 1991
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1255486
10 August 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 915519
27 July 1989
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 898409
16 June 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1339347
12 June 1989
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1203446
22 March 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 898121
20 December 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1032514
3 September 1987
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318562
5 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013543
26 September 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986965
30 July 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283733
5 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974154
1 March 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281679
26 February 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276407
Lifesaving
Issued 27 June 1991
Resolved
PROVIDE ON BOARD PROPER CAPACITY LIFERAFTS, ONE (1)-12 MAN & ONE (1)-15 MANUNTIL SUCH TIME, TOTAL PERSONS ALLOWED ON BOARD IS RESTRICTED TO TWENTY (20) PERSONS. 46 CFR 94.10-1(c)
Condition: Unknown
Due 27 June 1991
Resolved 27 June 1991
Fire Fighting
Issued 27 June 1991
Resolved
PROVIDE TO [name withheld], LA. A FIRE SAFETY BPLAN FOR REVEIW/APPROVAL. 46 CFR 91.55-5 (d)
Condition: Unknown
Due 27 June 1991
Resolved 27 June 1991
Construction/Loadline
Issued 27 June 1991
Resolved
REPAIR RUB RAIL (STBD AFT CORNER WRAPPER) TO THE SATISFACTION OF THE ATTENDING COAST CUARD MARINE INSPECTOR. 46 CFR 27.5-(a)
Condition: Unknown
Due 27 June 1991
Resolved 27 June 1991
Fire Fighting
Issued 12 June 1989
Resolved
PROVIDE ON BOAR A SELF-CONTAINED BREATHING APPARATUS AND SPARE CHARGE AS PER 46 CFR 96.30-15. COMPLIANCE DATE IS: 19JUN89
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Fire Fighting
Issued 12 June 1989
Resolved
HOLD AND LOG FIRE DRILL AS PER 46 CFR 97.15-35. COMPLIANCE DATE IS: 19JUN89
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Engineering
Issued 12 June 1989
Resolved
PROVE PROPER OPERATION OF MAIN ENGINE INSTRUMENT PANEL IN WHEELHOUSE AS PER46 CFR 96.05-1. COMPLIANCE DATE IS: 19JUN89
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Lifesaving
Issued 12 June 1989
Resolved
PRIOR TO PLACING VESSEL IN SERVICE COMPLETE INSTALLATION OF RESCUE BOAT DAVIT AND PROVIDE AN APPROVED RESCUE BOAT ON BOARD AS PER 46 CFR 94.10-5(E) COMPLIANCE DATE IS: 19JUN89
Condition: Unknown
Due 12 June 1989
Resolved 12 June 1989
Engineering
Issued 26 September 1985
Resolved
INSTALL REACH RODS ON DISCHARGE VALVES TO PORT AND STBD FUEL TANKS.
Condition: Unknown
Due 26 September 1985
Resolved 26 September 1985
Construction/Loadline
Issued 26 September 1985
Resolved
PROVIDE ONE (1) FIRE PUMP AND TWO (2) BILGE BALLAST PUMPS OR TWO (2) PUMPS THAT ARE INTERCHANGEBLE.
Condition: Unknown
Due 26 September 1985
Resolved 26 September 1985
Electrical
Issued 26 September 1985
Resolved
PROVIDE A BELL FOR THE GENERAL ALARM IN THE ENGINEROOM IN LIEU OF THE EXISTING SIREN.
Condition: Unknown
Due 26 September 1985
Resolved 26 September 1985
Unknown
Issued 5 April 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE M/V NICKIE MARIE CANDIES, O.N. 517536.
Condition: Unknown
Due 5 April 1984
Resolved 5 April 1984
Navigation
Issued 5 April 1984
Resolved
REPAIR STEERING FAILURE ALARMS.
Condition: Unknown
Due 5 April 1984
Resolved 5 April 1984
Documentation
Issued 5 April 1984
Resolved
UPDATE FUEL OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 5 April 1984
Resolved 5 April 1984
Documentation
Issued 5 April 1984
Resolved
PROVIDE VESSEL DOCUMENT.
Condition: Unknown
Due 5 April 1984
Resolved 5 April 1984
Documentation
Issued 5 April 1984
Resolved
PROVIDE FCC STATION LICENSE.
Condition: Unknown
Due 5 April 1984
Resolved 5 April 1984
Fire Fighting
Issued 1 March 1982
Resolved
PROVIDE FIRE CONTROL PLAN THAN ACCURATLY REFLECTS THE VESSEL.
Condition: Unknown
Due 3 March 1982
Resolved 1 March 1982
Construction/Loadline
Issued 1 March 1982
Resolved
RAISE HANDRAIL/BULWORK SO AS TO BE 39" ABOVE PROPOSED WALKWAY OVER CABLES.
Condition: Unknown
Due 3 March 1982
Resolved 1 March 1982
Deck/Cargo
Issued 1 March 1982
Resolved
WITHIN 30 DAYS PROVIDE APPROVED DRAWINGS FOR THE FOUR POINT MOORING SYSTEM.
Condition: Unknown
Due 1 March 1982
Resolved 1 March 1982
Deck/Cargo
Issued 1 March 1982
Resolved
PROVIDE GUARDS OVER ACC CABLE RUNS ASSOCIATED WITH 4-POINT MOORING SYSTEM.
Condition: Unknown
Due 3 March 1982
Resolved 1 March 1982
Unknown
Issued 1 March 1982
Resolved
PROVIDE CG APPROVED AIR RECEIVERS ON WINCHES.
Condition: Unknown
Due 3 March 1982
Resolved 1 March 1982