RANGER

RANGER is a 1981 school ship. The Coast Guard has recorded 26 inspections since 2016, most recently in February 2026, along with 13 deficiencies and 1 casualty investigation in 2011.

Records from 2011 to 2026. Most recent: inspection, 17 February 2026.

Built
1981
Last inspected
17 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the School Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 February 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WSJ4628
Flag
UNITED STATES
Maury page id
psix-53554

Documentation record

Registered dimensions (L × B × D)71.3 ft × 24.0 ft × 10.5 ft
Registered tonnagegross 108 / net 74
ITC dimensions (L × B × D)71.3 ft × 24.0 ft × 10.5 ft
ITC tonnageNot recorded
BuilderBAYOU LA BATRE ALABAMA · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBUZZARDS BAY, MA
Trade endorsementsRecreational
DocumentationValid · issued 5 August 2025 · expires 30 September 2026
Service, as the file records itSchool Ship
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it108 - Regulatory (Subpart C or D), Gross Ton
74 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

26 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 26

17 February 2026 COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8309719
9 July 2025 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8180401
1 July 2025 Administrative Inspection · Excursion Permit
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8172253
3 March 2025 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8086410
19 April 2024 Drydock Exam · Internal Structural Exam · Examination of Repairs · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7895318
4 April 2024 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7888152
23 February 2023 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7629158
9 September 2022 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7554887
14 July 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7491369
28 February 2022 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7402923
22 March 2021 COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7160878
21 December 2020 In-Service Inspection · Examination of Repairs
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7115116
7 July 2020 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6999189
13 March 2020 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7092167
8 March 2019 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6638792
27 February 2019 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6631619
14 January 2019 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6610050
24 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6521834
6 March 2018 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6366760
26 February 2018 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6356417
1 December 2017 In-Service Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6316214
20 September 2017 Excursion Permit
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6271000
15 August 2017 Excursion Permit
Administrative · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6248175
14 June 2017 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit New Bedford · USCG Northeast District (CGD-NE) · Activity 6175751
8 March 2017 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6101340
5 July 2016 Excursion Permit
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5930538

Deficiency record · 13

07 - Fire Safety › N/A - No Subsystem › Personal equipment for fire safety
Issued 9 March 2026 Resolved
Each nautical-school ship must be equipped with the following devices: (a) Two pressure-demand, open circuit, self-contained breathing apparatus ...The vessel is currently training and operating with two fireman's outfits that are 30 years old. The condition and wear of the outfits in unsatisfactory. Vessel to renew ensembles in order to meet current firefighting procedures. Provide to the satisfaction of the attending USCG MI within 30 days. 46CFR 167.45-60
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2026
Resolved 13 July 2026
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 3 March 2025 Resolved
Every crewmember must participate in at least one abandon-ship drill and one fire drill every month. The drills of the crew must take place within 24 hours of the vessel leaving a port if more than 25 percent of the crew have not participated in abandon-ship and fire drills on board that particular vessel in the previous month. Vessel was unable to provide proof of timely fire drills. Fire drill conducted and logged. 46CFR 199.180.c.2
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 3 March 2025
Resolved 3 March 2025
Resolution: Drill conducted, log created.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 March 2025 Resolved
If your vessel's Certificate of Inspection is renewed less often than annually, the marine inspector must check the settings of the safety or relief valves on all pressure vessels, except cargo tanks, twice every 5 years. No more than 3 years may elapse between any check and its immediate predecessor. Vessel was unable to provide last test results/date for the pressure relief devices on both engine room air receivers. Corrected on the spot with newly installed devices. 46CFR 31.10-5.1.2
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 3 March 2025
Resolved 3 March 2025
Resolution: devices renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 4 April 2024 Resolved
etallic band strapping used for cable support should be steel and corrosion treated if not a corrosion-resistant material. Cable retention devices should be installed not less than every 610 mm on vertical runs and not less than every 2.5 m on horizontal runs. Vertical wire runs in the machinery space noted for plastic zip-tie type fasteners. Provide metallic IAW with regulation. 46CFR 167.40-1
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2024
Resolved 29 April 2024
Resolution: Corrected installation.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 4 April 2024 Resolved
ent outlets from all tanks which may emit flammable or combustible vapors, such as bilge slop tanks and contaminated drain tanks, must be fitted with a single screen of corrosion-resistant wire of at least 30 by 30 mesh ...The FWD STBD Dirty Oil tank vent has an open goose-neck. Provide flame screen IAW regulation. 46CFR 56.50-85
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2024
Resolved 29 April 2024
Resolution: Screen installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 July 2022 Resolved
THE INSPECTION OF BOILERS SHALL BE IN ACCORDANCE WITH SUBCHATPER F; Installed small pkg fire tube boiler is requiered to be hydro tested, lift safety valve, and test all installed safeties e.g. flame out, low water cut off, high temp cutoff/alarm. In the presence of CG MI.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 July 2022
Resolved 8 November 2022
Resolution: BOILER HYDRO, FIRESIDE INSP, WATERSIDE INSP, AND ALL SAFETIES TESTED. REFRACTORY REPAIRED.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 27 February 2019 Resolved
The watertight door located on the main deck aft daylight can be seen on the bottom part of the hatch. Provide a new gasket and make watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2019
Resolved 13 March 2019
Resolution: Vessel provided a new gasket for the hatch.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 27 February 2019 Resolved
Vessel's emergency escape hatch located forward daylight can been seen. Repair or replace watertight gasket and make watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2019
Resolved 13 March 2019
Resolution: Vessel provided a new gasket.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 27 February 2019 Resolved
The emergency "E" light located above the port main engine needs to be remounted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2019
Resolved 13 March 2019
Resolution: Vessel repaired the light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 February 2019 Resolved
Vessel's heating boiler is overdue for its fire/waterside visual inspection. Make available for inspection or provide a servicing report.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 March 2019
Resolved 8 March 2019
Resolution: Vessel provided documentation that the boiler was inspected and a tech report was provided.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 24 August 2018 Resolved
Vsl is broadcasting: NAME with Vsl type precursor (NAME must not include Vsl type precursors, e.g. F/V, M/V).
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 September 2018
Resolved 14 January 2019
Resolution: Vessel corrected AIS broadcast information.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 26 February 2018 Resolved
Batteries have expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2018
Resolved 6 March 2018
Resolution: Batteries were replaced with new ones and marked with the installation date.
Engineering › Diesel Engine (auxiliary) › Governor
Issued 26 February 2018 Resolved
Overspeed is not working as designed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 March 2018
Resolved 6 March 2018
Resolution: Vessel was able to correct the issue and provide of evidence of it operating as designed.

Casualty record · 1

5 May 2011Routine · role: Involved in a Marine Casualty · activity 4003473
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.